Authorized Panduit Distributor
Panduit E42G06LTAA - TAA EL2P MSPO PDU, 20/16 AMP, (21)C13/C15, (21)C13/C15/C19/C21, IEC 60309 3P+N+E 6h 20A/16A (IP44)-3M, BLACK

Panduit E42G06LTAA TAA EL2P MSPO PDU, 20/16 AMP, (21)C13/C15, (21)C13/C15/C19/C21, IEC 60309 3P+N+E 6h…

UPC: 613056915916


Documents & Media
BrochureTechnical BulletinTechnical DrawingFull Engineering DrawingInstallation InstructionsSpecification SheetUser ManualOwners Manual

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The Panduit TAA EL2P MSPO PDU (SKU: E42G06LTAA) is a robust power distribution unit designed for reliable power delivery in industrial and data center environments. This unit features a versatile configuration with a total of 42 outlets, comprising 21 outlets rated for C13/C15 connectors and an additional 21 outlets supporting C13/C15/C19/C21 connectors, providing flexibility for a wide range of equipment. The PDU operates with a dual current rating of 20/16 Amps, accommodating varying power demands. Power input is supplied via an IEC 60309 3P+N+E 6h connector, rated for 20A/16A, ensuring compatibility with standard industrial power infrastructure. The PDU is finished in a standard black color for easy identification and integration into existing racks and cabinets. Engineered for demanding applications, the TAA EL2P MSPO PDU ensures consistent and safe power distribution for critical IT and industrial equipment. The 3-meter cable length provides ample reach for installation flexibility. This Panduit unit is compliant with TAA regulations, making it suitable for government and certain commercial applications requiring adherence to Trade Agreements Act standards. Its modular design and comprehensive outlet configuration make it an efficient solution for managing power in complex setups. The PDU's specifications are: Current Rating: 20/16 A, Color: Black, IP Rating: IP44, Poles: 3P+N+E, Connection Type: IEC 60309 3P+N+E, Series: TAA EL2P MSPO. This unit is manufactured by Panduit.
  • Dual current rating of 20/16 Amps for versatile power delivery.
  • Total of 42 outlets: 21x C13/C15 and 21x C13/C15/C19/C21 for broad equipment compatibility.
  • IEC 60309 3P+N+E 6h 20A/16A input connector for industrial power integration.
  • IP44 rated for protection against solid objects and splashing water.
  • TAA compliant for government and specific commercial applications.

Specifications

Frequency Rating, Maximum
240 V
Frequency Rating, Minimum
240 V
Material
Metal
Mounting
Vertical
Phase
3
Standard
UL 62368-1, CAN CSA-C22.2 No. 62368-1 EMC: FCC 47 CFR Part 15, Class A, Subpart B. ICES-003 Issue 7
Type
PDU
Width
2 in
Width
50.8 mm
Package Dimensions (L x W x H)
70.08 IN x 3 IN x 3 IN
Package Dimensions (L x W x H)
178.0032 cm x 7.62 cm x 7.62 cm
Package Weight (Imperial)
18.0700 L
Package Weight (Metric)
8.1966 kg
This Panduit G5 Basic PDU features (12) 5-20R outlets. It is a 20 amp, 120 V, single phase PDU with a NEMA 5-20P input plug and a 10 foot (3m) power cord. The PDU is black.

P12B19M

This Panduit G5 Basic PDU features (12) 5-20R outlets. It is a 20 amp, 120 V, single phase PDU with a NEMA 5-20P input plug and a 10 foot (3m) power cord. The PDU is black.
MI 208V 30A 42CX

EN1851

MI 208V 30A 42CX
19-inch Rack Mount Outlet Strip, 20A, 8 Switches & 8 Outlets, 15 ft cord, Black

1589W8G1BKRR

19-inch Rack Mount Outlet Strip, 20A, 8 Switches & 8 Outlets, 15 ft cord, Black
TAA EL2P MI PDU, 30 AMP, (21)C13/C15, (21)C13/C15/C19/C21, NEMA L22-30P-3M, BLACK

E42D07LTAA

TAA EL2P MI PDU, 30 AMP, (21)C13/C15, (21)C13/C15/C19/C21, NEMA L22-30P-3M, BLACK
TAA EL2P MS PDU, 30 AMP, (24)C13/C15, (24)C13/C15/C19/C21, NEMA L21-30P-3M, BLACK

E48E21LTAA

TAA EL2P MS PDU, 30 AMP, (24)C13/C15, (24)C13/C15/C19/C21, NEMA L21-30P-3M, BLACK
TAA EL2P MSPO PDU, 30/32 AMP, (24)C13/C15, (24)C13/C15/C19/C21, IEC 60309 3P+N+E 6h 30A/32A (IP44)-3M, BLACK

E48G30LTAA

TAA EL2P MSPO PDU, 30/32 AMP, (24)C13/C15, (24)C13/C15/C19/C21, IEC 60309 3P+N+E 6h 30A/32A (IP44)-3M, BLACK
TAA EL2P MSPO PDU, 30/32 AMP, (21)C13/C15, (21)C13/C15/C19/C21, IEC 60309 2P+E 6h 30A/32A (IP44)-3M, BLACK

E42G03LTAA

TAA EL2P MSPO PDU, 30/32 AMP, (21)C13/C15, (21)C13/C15/C19/C21, IEC 60309 2P+E 6h 30A/32A (IP44)-3M, BLACK
TAA EL2P MS PDU, 30/32 AMP, (24)C13/C15, (24)C13/C15/C19/C21, IEC 60309 3P+N+E 6h 30A/32A (IP44)-3M, BLACK

E48E20LTAA

TAA EL2P MS PDU, 30/32 AMP, (24)C13/C15, (24)C13/C15/C19/C21, IEC 60309 3P+N+E 6h 30A/32A (IP44)-3M, BLACK

Frequently Asked Questions

What is the maximum operating temperature for Panduit PDUs?

Panduit PDUs are built with premium components to withstand 140°F (60°C) at full load. Some ES2P models have a max operating temperature of 55°C.

What is the warranty period for Panduit PDUs?

Panduit PDUs come with a 3-year standard warranty, with options for a 2-year or 5-year extended warranty depending on the PDU series.

Are Panduit intelligent PDUs compatible with Cisco systems?

Yes, Panduit's intelligent PDUs seamlessly integrate with Cisco Nexus Dashboard software to enhance energy savings and sustainability insights.

What is the power scaling capability of the Universal PDU?

The Universal PDU supports power requirements from 3.3kW to 27.6kW, allowing power scaling by simply swapping the input cord.

What outlet types are available on Panduit PDUs?

Panduit PDUs offer various outlet types, including C13, C15, C19, C21, and NEMA 5-20R, with some models featuring combination outlets.

Which PDU series are compatible with SiteCommand Utility software?

The SiteCommand Utility software is compatible with Panduit's ES2P and EL2P series intelligent PDUs for bulk configuration and firmware updates.

What is the maximum daisy chain capacity for Panduit PDUs?

The maximum daisy chain capacity varies by series, with ES2P supporting 16, G6 supporting 32, and EL2P supporting up to 64 PDUs.

What is the metering accuracy of Panduit PDUs?

Metering accuracy is ±2% for ES2P and G6 series PDUs, while the EL2P series offers a higher accuracy of ±0.5%.

What network connectivity options are available for Panduit PDUs?

Panduit PDUs offer single or dual Gigabit Ethernet and serial connectivity. Some EL2P models also support Wi-Fi and Bluetooth via CNT06.

How are Panduit vertical PDUs mounted in a rack?

Vertical PDUs feature tool-less mounting buttons for quick and secure setup, enabling effortless attachment to rack keyhole slots.

How to Install a Panduit Rack Power Distribution Unit (PDU)

This guide provides step-by-step instructions for qualified personnel to safely install a Panduit Rack Power Distribution Unit (PDU) into a datacenter rack or cabinet, covering mounting, grounding, and connecting to a power source.

Estimated time: 45m

Tools needed:

#2 Phillips screwdriver, T10 Torx screwdriver, 2.5mm hex key Allen wrench

Supplies needed:

Cage nuts (for horizontal mounting), Ground bonding cable (if required by local codes), Star washer (for ground bonding), Blanking panels (for unused rack spaces)

  1. Review Safety Information and Prepare Installation Area

    Before beginning, thoroughly read all safety information in the installation manual, especially regarding high leakage current, electrical shock, and hazardous energy levels. Ensure the installation area is a temperature and humidity-controlled indoor environment, free of conductive contaminants. Maintain a minimum clearance of 2 to 3 inches between the PDU chassis and cabinet frame to ensure effective heat dissipation. Seal any unused rack spaces with blanking panels to promote proper airflow. Ensure all circuit breakers are in the off position before connecting input power.

  2. Mount the PDU in the Rack

    For vertical (0U) PDUs, insert the pre-installed mounting buttons into the keyhole slots on the PDU mounting bracket in the rack. Secure with a #2 Phillips screwdriver to a recommended torque of 3.0Nm. For horizontal (1U/2U) PDUs, install cage nuts at the desired U location(s) on both front and rear equipment rails. Screw the mounting bracket ears into the RETMA rail surface where the cage nuts were installed. For high-power horizontal PDUs, also screw the mounting brackets on the front into the PDU chassis using a 2.5mm hex key Allen wrench. Ensure the PDU is firmly attached.

  3. Ground the PDU Chassis

    Ensure a reliable grounded (earthed) connection is established before connecting AC power. Locate the external ground bonding point and screw on the PDU chassis, typically on the surface with the outlets. Use a ground bonding cable and star washer to connect this point to a known earthed reference terminal in the building or to the rack metalwork, adhering to National or Local Electrical Codes for conductor sizing. This provides supplementary Earth bonding.

  4. Adjust Network Controller Orientation (Optional)

    If a specific physical orientation for the network controller ports is desired, use a T10 Torx screwdriver to remove the two retaining screws. Carefully disconnect the ribbon cable to prevent damage. Rotate the controller to the preferred orientation, then carefully reconnect the ribbon cable, ensuring no crimping or pinching. Reinstall and torque the two screws to 2.2–3.1 lbf-in [0.25–0.35 N-M]. Avoid overtightening.

  5. Connect the PDU to a Power Source

    Verify that all circuit breakers on the PDU are set to the "On" position. Connect the PDU's input power cord to an appropriately rated, grounded (earthed) branch circuit that adheres to all local and national electrical codes. Ensure the power cord has sufficient length to reach the power source. Refer to the compliance label on the PDU for input ratings. After connecting, turn the feed circuit breaker "On" and wait for the operating system to load and the Main Menu to display on the screen.

  6. Perform Initial Configuration for Dual Rated PDUs

    If installing a dual-rated PDU, perform an additional Command Line Interface (CLI) configuration step to enable the Web interface to report the correct power capacity. Refer to the PDU User Manual for specific CLI commands and details on this procedure.

Frequently Asked Questions about Panduit

What environmental ratings do Panduit products have?

Panduit products feature comprehensive environmental ratings across multiple standards, including UL 508A Type 1, 2, 3, 4, 4X, 12, and 13; CSA Type 1, 2, 3, 4, 4X, 12, and 13; and NEMA Type 1, 2, 3, 4, 4X, 12, and 13. They meet IEC 60529 IP66 rating, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments, with operating temperatures ranging from -40°C to 130°C.

What certifications and standards do Panduit products comply with?

Panduit products are certified to multiple critical industry standards, including UL (Underwriters Laboratories) in the USA and Canada, CSA (Canadian Standard Association), EN IEC 61386, LVD 2006/G5/EC, and ARRA standards. Our products meet rigorous certifications for electrical safety, environmental compliance (WEEE and RoHS), and are designed to perform in extreme temperatures ranging from -55°C to 105°C, making them suitable for demanding industrial environments.

What industries and applications are Panduit products used for?

Panduit products are engineered for critical applications across multiple industries, including commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety-critical environments. Their solutions span electrical infrastructure, wire management, cable ties, power connectors, and safety systems designed to withstand extreme conditions like high vibration, temperature variations, UV exposure, and corrosive agents. Key industries include solar and wind energy, aerospace, heavy trucking, military, commercial transportation, and industrial manufacturing.

What are the main product lines offered by Panduit?

Panduit offers a comprehensive range of electrical infrastructure products including power connectors, cable ties, grounding connectors, identification products, safety solutions, terminals, cable cleats, wiring duct, and cable tie accessories. These products are engineered for industrial environments across multiple sectors like commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety applications.

What are the key features of Panduit products?

Panduit products are engineered for robust performance in heavy-duty industrial environments, featuring a comprehensive range of solutions including cable ties, power connectors, terminals, and identification products. Key features include proven quality performance, subject matter expertise, and customer-driven innovation across multiple industrial sectors such as commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety applications. The product line is designed to maximize productivity, reliability, and safety while meeting stringent industry standards.

What is Panduit's warranty policy?

Panduit provides a comprehensive Limited Product Warranty that can be fully reviewed on their official website at www.panduit.com/warranty. All Panduit products are subject to the terms, conditions, and limitations of this current warranty. Customers are advised to review the specific warranty details for their particular product, as Panduit requires buyers to determine product suitability for their intended use and assumes all associated risks.

What technical support does Panduit offer?

Panduit offers comprehensive technical support through their dedicated customer service team, accessible via phone at 1-800-777-3300. They provide expert assistance for their full range of industrial infrastructure products, including cable ties, power connectors, terminals, and identification solutions. Customers can also access additional technical resources and product information through their website at www.panduit.com.

What accessories are available for Panduit products?

Panduit offers a wide range of accessories across multiple product lines, including cable ties, cable tie accessories, cable tie tools, identification products, cable cleats, grounding connectors, and VeriSafe accessories like the VeriSafe Network Module and Insulation Piercing Connectors. For a comprehensive view of all available accessories, customers are recommended to visit www.panduit.com for the full product catalog.

How are Panduit products typically installed?

Panduit products are engineered for comprehensive installation across industrial environments, utilizing specialized tools and techniques for precise mounting. Installation methods vary by product line - from cable ties and power connectors to terminals and identification solutions - but all are designed for robust performance in heavy-duty settings. Technicians typically use Panduit's dedicated installation tools and follow manufacturer guidelines available at www.panduit.com to ensure proper fitting and maximum infrastructure reliability.