Panduit E42G04LTAA - TAA EL2P MSPO PDU, 30 AMP, (21)C13/C15, (21)C13/C15/C19/C21, NEMA L15-30P-3M, BLACK

Panduit E42G04LTAA TAA EL2P MSPO PDU, 30 AMP, (21)C13/C15, (21)C13/C15/C19/C21, NEMA L15-30P-3M, BLACK

UPC: 613056916005


Documents & Media
BrochureTechnical BulletinTechnical DrawingFull Engineering DrawingInstallation InstructionsSpecification SheetUser ManualOwners Manual

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The Panduit E42G04LTAA TAA EL2P MSPO PDU delivers 30-amp power distribution with (21) C13/C15 outlets on the primary side and (21) C13/C15/C19/C21 outlets on the secondary side, supporting mixed device loads in a single unit. This PDU features a NEMA L15-30P plug with a 3-meter cord, ensuring compatibility with standard 30-amp, 125/250V power sources. The black housing provides a professional appearance while maintaining durability for industrial and commercial environments. Designed for flexibility, the E42G04LTAA accommodates both legacy and modern IT equipment with its combination of C13, C15, C19, and C21 outlets. The primary side supports up to 21 devices with C13/C15 plugs, while the secondary side expands compatibility to include C19/C21 high-power devices. This configuration is ideal for data centers, network closets, or industrial control panels where mixed power requirements exist. The NEMA L15-30P input ensures compatibility with 30-amp, 125/250V power sources, providing stable power delivery for high-density deployments. The 3-meter cord length offers installation flexibility without requiring additional extension solutions. This PDU is part of Panduit’s TAA-compliant line, meeting federal procurement requirements for government and enterprise applications.
  • 30-amp power distribution with NEMA L15-30P input
  • (21) C13/C15 outlets on primary side, (21) C13/C15/C19/C21 on secondary side
  • 3-meter cord for flexible installation
  • Black housing for professional industrial/commercial use
  • TAA-compliant for government and enterprise procurement

Specifications

Color
Black
Connection Type
Plug (3m cord)
Current Rating
30 A
Frequency Rating, Maximum
208 V
Frequency Rating, Minimum
208 V
Material
Metal
Material
Plastic/Metal
Mounting
Vertical
Mounting Type
Rackmount
Nema Rating
NEMA L15-30P
Phase
3
Poles
2P+G
Series
TAA EL2P MSPO
Standard
UL 62368-1, CAN CSA-C22.2 No. 62368-1 EMC: FCC 47 CFR Part 15, Class A, Subpart B. ICES-003 Issue 7
Type
PDU
Width
2 in
Width
50.8 mm
Package Dimensions (L x W x H)
70.08 IN x 3 IN x 3 IN
Package Dimensions (L x W x H)
178.0032 cm x 7.62 cm x 7.62 cm
Package Weight (Imperial)
22.0500 L
Package Weight (Metric)
10.0019 kg
This Panduit G5 Basic PDU features (12) 5-20R outlets. It is a 20 amp, 120 V, single phase PDU with a NEMA 5-20P input plug and a 10 foot (3m) power cord. The PDU is black.

P12B19M

This Panduit G5 Basic PDU features (12) 5-20R outlets. It is a 20 amp, 120 V, single phase PDU with a NEMA 5-20P input plug and a 10 foot (3m) power cord. The PDU is black.
MI 208V 30A 42CX

EN1851

MI 208V 30A 42CX
19-inch Rack Mount Outlet Strip, 20A, 8 Switches & 8 Outlets, 15 ft cord, Black

1589W8G1BKRR

19-inch Rack Mount Outlet Strip, 20A, 8 Switches & 8 Outlets, 15 ft cord, Black
TAA EL2P MSPO PDU, 20/16 AMP, (21)C13/C15, (21)C13/C15/C19/C21, IEC 60309 3P+N+E 6h 20A/16A (IP44)-3M, BLACK

E42G06LTAA

TAA EL2P MSPO PDU, 20/16 AMP, (21)C13/C15, (21)C13/C15/C19/C21, IEC 60309 3P+N+E 6h 20A/16A (IP44)-3M, BLACK
TAA EL2P MI PDU, 30 AMP, (21)C13/C15, (21)C13/C15/C19/C21, NEMA L22-30P-3M, BLACK

E42D07LTAA

TAA EL2P MI PDU, 30 AMP, (21)C13/C15, (21)C13/C15/C19/C21, NEMA L22-30P-3M, BLACK
TAA EL2P MS PDU, 30 AMP, (24)C13/C15, (24)C13/C15/C19/C21, NEMA L21-30P-3M, BLACK

E48E21LTAA

TAA EL2P MS PDU, 30 AMP, (24)C13/C15, (24)C13/C15/C19/C21, NEMA L21-30P-3M, BLACK
TAA EL2P MSPO PDU, 30/32 AMP, (24)C13/C15, (24)C13/C15/C19/C21, IEC 60309 3P+N+E 6h 30A/32A (IP44)-3M, BLACK

E48G30LTAA

TAA EL2P MSPO PDU, 30/32 AMP, (24)C13/C15, (24)C13/C15/C19/C21, IEC 60309 3P+N+E 6h 30A/32A (IP44)-3M, BLACK
TAA EL2P MSPO PDU, 30/32 AMP, (21)C13/C15, (21)C13/C15/C19/C21, IEC 60309 2P+E 6h 30A/32A (IP44)-3M, BLACK

E42G03LTAA

TAA EL2P MSPO PDU, 30/32 AMP, (21)C13/C15, (21)C13/C15/C19/C21, IEC 60309 2P+E 6h 30A/32A (IP44)-3M, BLACK

Frequently Asked Questions

What is the standard warranty for Panduit PDUs?

Panduit PDUs come with a 3-year standard warranty, which can be extended to 5 years.

What is the maximum operating temperature?

Panduit PDUs are built with premium components to withstand 140°F (60°C) at full load.

Do Panduit PDUs feature hot-swappable controllers?

Yes, Panduit PDUs feature hot-swappable controllers that can be removed without affecting outlet status, ideal for service or repair.

What network connectivity options are available?

PDUs offer single or dual Gigabit Ethernet and serial connectivity. Some models also support Wi-Fi and Bluetooth via CNT06.

What can Panduit PDUs monitor in real-time?

Panduit PDUs provide real-time monitoring of power, environmental conditions, and cabinet security.

Are Panduit PDUs compatible with Cisco systems?

Yes, Panduit's intelligent PDUs are compatible with Cisco Nexus Dashboard software for enhanced energy savings and sustainability insights.

Do Panduit PDUs integrate with DCIM solutions?

Yes, intelligent PDUs offer integration with monitoring software for data management and analytics, with EL2P series having native Cisco Nexus Dashboard and Redfish API integration.

What is the maximum daisy chain capacity?

Daisy chain capacity varies by model, with ES2P supporting 16, G6 supporting 32, and EL2P supporting up to 64 PDUs.

What is the metering accuracy of Panduit PDUs?

Metering accuracy is ± 2% for ES2P and G6 models, and ± 0.5% for EL2P models.

How are vertical PDUs mounted?

Vertical PDUs feature tool-less mounting buttons for quick and secure attachment to rack keyhole slots, simplifying setup.

How to Install the Panduit EL2P PDU

This guide provides step-by-step instructions for qualified personnel to safely install a Panduit Rack Power Distribution Unit (PDU) into a datacenter rack or cabinet, covering mounting, grounding, and connecting to a power source.

Estimated time: 1h

Tools needed:

#2 Phillips screwdriver, T10 Torx screwdriver, T20 Torx screwdriver, 2.5mm hex key Allen wrench

Supplies needed:

PDU mounting hardware (buttons, screws, cage nuts), Ground bonding cable, Blanking panels

  1. Prepare the Installation Environment and Review Safety

    Before beginning, ensure the installation area maintains an ambient temperature between 0°C to 60°C (32°F to 140°F) and is free of conductive contaminants. Verify that the PDU's voltage matches the line voltage of the power source. Ensure a reliable grounded (earthed) connection is available before connecting power distribution products to AC power to reduce the risk of electric shock due to high leakage currents.

  2. Mount the PDU in the Rack

    For vertical (0U) PDUs, insert the pre-installed mounting buttons into the keyhole slots on the PDU mounting bracket in the rack. Secure using a #2 Phillips screwdriver to a recommended torque of 3.0Nm. For horizontal (1U/2U) PDUs, install cage nuts at the desired U location on both front and rear equipment rails. Screw the mounting bracket ears into the RETMA rail surface. If necessary, adjust mounting ear positions by removing and re-fastening screws with a 2.5mm hex key Allen wrench. Ensure a minimum clearance of 2 to 3 inches between the PDU chassis and cabinet frame for airflow, and seal unused rack spaces with blanking panels.

  3. Ground the PDU

    Connect a ground bonding cable to the external ground bonding point located on the PDU chassis, typically found on the surface with the outlets. Bond the PDU to a known earthed reference terminal in the building or a grounding strip/bus bar within the rack. Ensure the conductor size meets national or local electrical codes (e.g., 14 AWG for up to 15A, 12 AWG for up to 20A).

  4. Connect the PDU to a Power Source

    WARNING: A risk of personal injury from electric shock and hazardous energy levels exists. Ensure all circuit breakers are in the OFF position before connecting input power. Turn the feed circuit breaker OFF at the power source. Verify all circuit breakers on the PDU are set to ON. Connect the PDU's input power cord to an appropriately rated, grounded (earthed) branch circuit, adhering to all local and national electrical codes. Turn the feed circuit breaker ON. Wait for the operating system to load; the Main Menu will display on the screen.

  5. Optional: Rotate or Replace Network Controller

    If desired, the network control module can be manually rotated or replaced. Using a T10 Torx screwdriver, remove the two retaining screws. If rotating, DISCONNECT the ribbon cable to prevent damage, rotate the controller, then carefully reconnect the ribbon cable. If replacing, disconnect the existing ribbon cable and connect it to the new controller. Re-install the controller and torque the two screws to 2.2–3.1 lbf-in [0.25–0.35 N-M], avoiding overtightening.

Frequently Asked Questions about Panduit

What environmental ratings do Panduit products have?

Panduit products feature comprehensive environmental ratings across multiple standards, including UL 508A Type 1, 2, 3, 4, 4X, 12, and 13; CSA Type 1, 2, 3, 4, 4X, 12, and 13; and NEMA Type 1, 2, 3, 4, 4X, 12, and 13. They meet IEC 60529 IP66 rating, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments, with operating temperatures ranging from -40°C to 130°C.

What certifications and standards do Panduit products comply with?

Panduit products are certified to multiple critical industry standards, including UL (Underwriters Laboratories) in the USA and Canada, CSA (Canadian Standard Association), EN IEC 61386, LVD 2006/G5/EC, and ARRA standards. Our products meet rigorous certifications for electrical safety, environmental compliance (WEEE and RoHS), and are designed to perform in extreme temperatures ranging from -55°C to 105°C, making them suitable for demanding industrial environments.

What industries and applications are Panduit products used for?

Panduit products are engineered for critical applications across multiple industries, including commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety-critical environments. Their solutions span electrical infrastructure, wire management, cable ties, power connectors, and safety systems designed to withstand extreme conditions like high vibration, temperature variations, UV exposure, and corrosive agents. Key industries include solar and wind energy, aerospace, heavy trucking, military, commercial transportation, and industrial manufacturing.

What are the main product lines offered by Panduit?

Panduit offers a comprehensive range of electrical infrastructure products including power connectors, cable ties, grounding connectors, identification products, safety solutions, terminals, cable cleats, wiring duct, and cable tie accessories. These products are engineered for industrial environments across multiple sectors like commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety applications.

What are the key features of Panduit products?

Panduit products are engineered for robust performance in heavy-duty industrial environments, featuring a comprehensive range of solutions including cable ties, power connectors, terminals, and identification products. Key features include proven quality performance, subject matter expertise, and customer-driven innovation across multiple industrial sectors such as commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety applications. The product line is designed to maximize productivity, reliability, and safety while meeting stringent industry standards.

What is Panduit's warranty policy?

Panduit provides a comprehensive Limited Product Warranty that can be fully reviewed on their official website at www.panduit.com/warranty. All Panduit products are subject to the terms, conditions, and limitations of this current warranty. Customers are advised to review the specific warranty details for their particular product, as Panduit requires buyers to determine product suitability for their intended use and assumes all associated risks.

What technical support does Panduit offer?

Panduit offers comprehensive technical support through their dedicated customer service team, accessible via phone at 1-800-777-3300. They provide expert assistance for their full range of industrial infrastructure products, including cable ties, power connectors, terminals, and identification solutions. Customers can also access additional technical resources and product information through their website at www.panduit.com.

What accessories are available for Panduit products?

Panduit offers a wide range of accessories across multiple product lines, including cable ties, cable tie accessories, cable tie tools, identification products, cable cleats, grounding connectors, and VeriSafe accessories like the VeriSafe Network Module and Insulation Piercing Connectors. For a comprehensive view of all available accessories, customers are recommended to visit www.panduit.com for the full product catalog.

How are Panduit products typically installed?

Panduit products are engineered for comprehensive installation across industrial environments, utilizing specialized tools and techniques for precise mounting. Installation methods vary by product line - from cable ties and power connectors to terminals and identification solutions - but all are designed for robust performance in heavy-duty settings. Technicians typically use Panduit's dedicated installation tools and follow manufacturer guidelines available at www.panduit.com to ensure proper fitting and maximum infrastructure reliability.