Panduit E24D02L - EL2P MI PDU, 100/125 AMP, (24)C13/C15/C19/C21, IEC 60309 3P+N+E 6h 100A/125A (IP67)-3M, BLACK
Panduit

E24D02L

UPC: 613056920194


Documents & Media
BrochureTechnical BulletinTechnical DrawingFull Engineering DrawingInstallation InstructionsUser ManualOwners Manual

Contact for Pricing

Overview

The Panduit EL2P MI PDU (SKU: E24D02L) is a robust power distribution unit designed for critical infrastructure applications. This unit features 24 outlets, accommodating a mix of C13, C15, C19, and C21 connector types, providing versatile power delivery for a range of IT and industrial equipment. It supports both 100 AMP and 125 AMP current ratings, ensuring compatibility with high-demand systems. The integrated IEC 60309 3P+N+E 6h plug, rated for 100A/125A, offers a secure and reliable connection, crucial for preventing power interruptions. Furthermore, the PDU boasts an IP67 rating, signifying its protection against dust ingress and immersion in water up to 1 meter, making it suitable for challenging environmental conditions where standard PDUs would fail. The 3-meter cable length provides adequate reach for flexible installation in data centers, industrial facilities, or other mission-critical environments. This Panduit PDU is engineered for reliable power distribution in demanding operational settings.
  • 24 mixed outlets (C13/C15/C19/C21)
  • 100/125 AMP current rating
  • IEC 60309 3P+N+E 6h 100A/125A plug
  • IP67 rated for dust and water protection
  • 3-meter cable length

Specifications

Phase
3-Phase
Standard
Nemko Listed Certificate: NA202011186, CE, UKCA, ROHS, REACH, China ROHS
Type
PDU
Package Dimensions (L x W x H)
66 IN x 8 IN x 5 IN
Package Dimensions (L x W x H)
167.64 cm x 20.32 cm x 12.7 cm
Package Weight (Imperial)
11.5000 L
Package Weight (Metric)
5.2164 kg
AC Diagnostic Tool with Interface Cable 120V20A EV12020 IC

EV12020IC

AC Diagnostic Tool with Interface Cable 120V20A EV12020 IC
Battery Pack for use with VeriSafe Access Contorl Kit VS-ACK-CPWR.

VS-ACK-BATTERY

Battery Pack for use with VeriSafe Access Contorl Kit VS-ACK-CPWR.
560SFR02 R0001

1KGT022200R0000

560SFR02 R0001
EL2P MSPO PDU, 30 (24) AMP, (12)C13/C15, (12)C13/C15/C19/C21, NEMA L6-30P-3M, BLACK

E24G01L

EL2P MSPO PDU, 30 (24) AMP, (12)C13/C15, (12)C13/C15/C19/C21, NEMA L6-30P-3M, BLACK
EL2P MSPO PDU, 30 (24) AMP, (12)C13/C15, (12)C13/C15/C19/C21, NEMA L15-30P-3M, BLACK

E24G02L

EL2P MSPO PDU, 30 (24) AMP, (12)C13/C15, (12)C13/C15/C19/C21, NEMA L15-30P-3M, BLACK
EL2P MSPO PDU, 60 (48) AMP, (12)C13/C15, (12)C13/C15/C19/C21, IEC 60309 3P+E 9h 60A (IP44)-3M, BLACK

E24G05L

EL2P MSPO PDU, 60 (48) AMP, (12)C13/C15, (12)C13/C15/C19/C21, IEC 60309 3P+E 9h 60A (IP44)-3M, BLACK
EL2P MSPO PDU, 30 (24) AMP, (12)C13/C15, (12)C13/C15/C19/C21, NEMA L21-30P-3M, BLACK

E24G03L

EL2P MSPO PDU, 30 (24) AMP, (12)C13/C15, (12)C13/C15/C19/C21, NEMA L21-30P-3M, BLACK
AC Diagnostic Tool with Interface Cable 208V15A EV20815 IC

EV20815IC

AC Diagnostic Tool with Interface Cable 208V15A EV20815 IC

Frequently Asked Questions

What is the standard warranty for Panduit PDUs?

Panduit PDUs come with a 3-year standard warranty, which can be extended to 5 years.

What is the maximum operating temperature?

Panduit PDUs are built with premium components to withstand 140°F (60°C) at full load.

Do Panduit PDUs feature hot-swappable controllers?

Yes, Panduit PDUs feature hot-swappable controllers that can be removed without affecting outlet status, ideal for service or repair.

What network connectivity options are available?

PDUs offer single or dual Gigabit Ethernet and serial connectivity. Some models also support Wi-Fi and Bluetooth via CNT06.

What can Panduit PDUs monitor in real-time?

Panduit PDUs provide real-time monitoring of power, environmental conditions, and cabinet security.

Are Panduit PDUs compatible with Cisco systems?

Yes, Panduit's intelligent PDUs are compatible with Cisco Nexus Dashboard software for enhanced energy savings and sustainability insights.

Do Panduit PDUs integrate with DCIM solutions?

Yes, intelligent PDUs offer integration with monitoring software for data management and analytics, with EL2P series having native Cisco Nexus Dashboard and Redfish API integration.

What is the maximum daisy chain capacity?

Daisy chain capacity varies by model, with ES2P supporting 16, G6 supporting 32, and EL2P supporting up to 64 PDUs.

What is the metering accuracy of Panduit PDUs?

Metering accuracy is ± 2% for ES2P and G6 models, and ± 0.5% for EL2P models.

How are vertical PDUs mounted?

Vertical PDUs feature tool-less mounting buttons for quick and secure attachment to rack keyhole slots, simplifying setup.

How to Install the Panduit EL2P Rack Power Distribution Unit (PDU)

This guide provides step-by-step instructions for qualified personnel to safely install and connect a Panduit EL2P Rack Power Distribution Unit (PDU) into a datacenter rack or cabinet.

Estimated time: 1h

Tools needed:

#2 Phillips screwdriver, T10 Torx screwdriver, 2.5mm hex key Allen wrench

Supplies needed:

Cage nuts (for horizontal mounting), Ground bonding cable (appropriate gauge), Mounting hardware (provided with PDU)

  1. Review Safety Information and Prepare for Installation

    Before beginning, thoroughly read all safety information in the PDU installation manual. Ensure that installation is performed by qualified personnel knowledgeable about AC power products. Verify that the PDU is intended for Information Technology Equipment (ITE) loads with linear/Power Factor Corrected (PFC) input current. If non-linear loads are connected, reduce the nameplate current rating by a factor of 0.8. Ensure a reliable grounded (earthed) connection is available before connecting to AC power. WARNING: This PDU contains lethal voltages; no user-serviceable parts are inside. Disconnect the power cord to isolate this equipment.

  2. Mount the PDU in the Rack or Cabinet

    Determine the appropriate mounting method (vertical 0U or horizontal 1U/2U) for your PDU model and rack. For vertical PDUs, insert the pre-installed mounting buttons into the keyhole slots on the rack's PDU mounting bracket and secure them using a #2 Phillips screwdriver to a recommended torque of 3.0Nm. For horizontal PDUs, install cage nuts at the desired U location(s) on the front and, if applicable, rear RETMA rails. Screw the mounting bracket ears into the RETMA rail surface using appropriate screws. If necessary, adjust mounting ear positions or rotate them 180 degrees by removing and re-fastening screws. For high-power horizontal PDUs, use a 2.5mm hex key Allen wrench to tighten the socket head screws on the front mounting brackets into the PDU chassis. Maintain a minimum clearance of 2 to 3 inches between the PDU chassis and cabinet frame for airflow.

  3. Ground the PDU

    Connect a ground bonding cable of appropriate gauge (meeting national/local electrical codes, e.g., 14 AWG for up to 15A, 12 AWG for up to 20A) from the external ground bonding point on the PDU chassis to a known earthed reference terminal in the building, a grounding strip, or a grounding bus bar in the rack. This provides supplementary Earth bonding to the rack metalwork. Ensure the connection is secure.

  4. Connect the PDU to a Power Source

    WARNING: Ensure all circuit breakers are in the OFF position before connecting input power. Turn OFF the feed circuit breaker for the dedicated branch circuit. Verify that all circuit breakers on the PDU itself are set to ON. Connect the PDU's input power cord to an appropriately rated, grounded (earthed) electrical outlet on the dedicated branch circuit, adhering to all local and national electrical codes. Ensure the outlet is near the equipment and easily accessible. Do not overload the PDU; the total input current of connected equipment cannot exceed the PDU's total output rating. Verify that connected devices are capable of operating from the same line voltage supplying the PDU.

  5. Power On and Verify Operation

    Turn ON the feed circuit breaker for the dedicated branch circuit. Allow time for the PDU's operating system to load. Once complete, the Main Menu should display on the PDU screen. For Switched (MS) and Monitored & Switched per Outlet (MSPO) PDUs, observe the LEDs corresponding to each outlet as they power on to confirm functionality. For dual-rated PDUs, an additional CLI configuration step may be required to enable the Web interface to report the correct power capacity; refer to the User Manual for details.

Frequently Asked Questions about Panduit

What environmental ratings do Panduit products have?

Panduit products feature comprehensive environmental ratings across multiple standards, including UL 508A Type 1, 2, 3, 4, 4X, 12, and 13; CSA Type 1, 2, 3, 4, 4X, 12, and 13; and NEMA Type 1, 2, 3, 4, 4X, 12, and 13. They meet IEC 60529 IP66 rating, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments, with operating temperatures ranging from -40°C to 130°C.

What certifications and standards do Panduit products comply with?

Panduit products are certified to multiple critical industry standards, including UL (Underwriters Laboratories) in the USA and Canada, CSA (Canadian Standard Association), EN IEC 61386, LVD 2006/G5/EC, and ARRA standards. Our products meet rigorous certifications for electrical safety, environmental compliance (WEEE and RoHS), and are designed to perform in extreme temperatures ranging from -55°C to 105°C, making them suitable for demanding industrial environments.

What industries and applications are Panduit products used for?

Panduit products are engineered for critical applications across multiple industries, including commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety-critical environments. Their solutions span electrical infrastructure, wire management, cable ties, power connectors, and safety systems designed to withstand extreme conditions like high vibration, temperature variations, UV exposure, and corrosive agents. Key industries include solar and wind energy, aerospace, heavy trucking, military, commercial transportation, and industrial manufacturing.

What are the main product lines offered by Panduit?

Panduit offers a comprehensive range of electrical infrastructure products including power connectors, cable ties, grounding connectors, identification products, safety solutions, terminals, cable cleats, wiring duct, and cable tie accessories. These products are engineered for industrial environments across multiple sectors like commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety applications.

What are the key features of Panduit products?

Panduit products are engineered for robust performance in heavy-duty industrial environments, featuring a comprehensive range of solutions including cable ties, power connectors, terminals, and identification products. Key features include proven quality performance, subject matter expertise, and customer-driven innovation across multiple industrial sectors such as commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety applications. The product line is designed to maximize productivity, reliability, and safety while meeting stringent industry standards.

What is Panduit's warranty policy?

Panduit provides a comprehensive Limited Product Warranty that can be fully reviewed on their official website at www.panduit.com/warranty. All Panduit products are subject to the terms, conditions, and limitations of this current warranty. Customers are advised to review the specific warranty details for their particular product, as Panduit requires buyers to determine product suitability for their intended use and assumes all associated risks.

What technical support does Panduit offer?

Panduit offers comprehensive technical support through their dedicated customer service team, accessible via phone at 1-800-777-3300. They provide expert assistance for their full range of industrial infrastructure products, including cable ties, power connectors, terminals, and identification solutions. Customers can also access additional technical resources and product information through their website at www.panduit.com.

What accessories are available for Panduit products?

Panduit offers a wide range of accessories across multiple product lines, including cable ties, cable tie accessories, cable tie tools, identification products, cable cleats, grounding connectors, and VeriSafe accessories like the VeriSafe Network Module and Insulation Piercing Connectors. For a comprehensive view of all available accessories, customers are recommended to visit www.panduit.com for the full product catalog.

How are Panduit products typically installed?

Panduit products are engineered for comprehensive installation across industrial environments, utilizing specialized tools and techniques for precise mounting. Installation methods vary by product line - from cable ties and power connectors to terminals and identification solutions - but all are designed for robust performance in heavy-duty settings. Technicians typically use Panduit's dedicated installation tools and follow manufacturer guidelines available at www.panduit.com to ensure proper fitting and maximum infrastructure reliability.