Authorized Panduit Distributor
Panduit E24E30L - EL2P MS PDU, 30 (24) AMP, (12)C13/C15, (12)C13/C15/C19/C21, NEMA L21-30P-3M, BLACK
Panduit

E24E30L

UPC: 613056920439


Documents & Media
BrochureTechnical BulletinTechnical DrawingFull Engineering DrawingInstallation InstructionsUser ManualOwners Manual

Contact for Pricing

Overview

The Panduit EL2P MS PDU (SKU: E24E30L) is a robust power distribution unit designed for reliable power management in IT and industrial environments. This unit features a 30 Amp rating and provides 24 outlets for device connectivity. The outlet configuration includes 12 outlets with C13/C15 compatibility and another 12 outlets supporting C13/C15/C19/C21 connectors, offering significant flexibility for various equipment types. The PDU is equipped with a NEMA L21-30P plug, a 3-meter cord, and comes in a black finish. Its design facilitates efficient power distribution to servers, network switches, and other critical infrastructure components. The UNSPSC code for this product is 39121106. This PDU is engineered to deliver consistent power, ensuring operational uptime for your connected devices. Its comprehensive outlet selection accommodates a wide range of power cords, simplifying deployment and management within data centers or industrial control panels. The 3-meter cord length provides adequate reach for typical installations.
  • 30 Amp current rating for substantial power delivery.
  • 24 total outlets: 12x C13/C15 and 12x C13/C15/C19/C21 for diverse equipment.
  • NEMA L21-30P plug type for secure and standard connections.
  • 3-meter power cord for flexible installation placement.
  • Black finish for a clean and professional appearance.

Specifications

Color
Black
Current Rating
30 (24) A
Nema Rating
NEMA L21-30P
Phase
3-Phase
Series
EL2P MS PDU
Standard
Nemko Listed Certificate: NA202011186, CE, UKCA, ROHS, REACH, China ROHS
Type
PDU
Package Dimensions (L x W x H)
68 IN x 11 IN x 6 IN
Package Dimensions (L x W x H)
172.72 cm x 27.94 cm x 15.24 cm
Package Weight (Imperial)
24.0000 L
Package Weight (Metric)
10.8864 kg
Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum

14A0705

Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum
Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.

BX4

Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black

LH38

Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black
EP-RJG-M20-BL-A

1SNG618003R0000

EP-RJG-M20-BL-A
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey

LN43DA

1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey

LT20D-NEW

1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey
External operation handle 0-1 type S01 Red Nema 4,4x

140E2911

External operation handle 0-1 type S01 Red Nema 4,4x
Escutcheon black type B for Sircover 125-630A

44095015

Escutcheon black type B for Sircover 125-630A
12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

FF20A115UE1

12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12
5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

FF12D24NN53

5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

Frequently Asked Questions

What is the standard warranty for Panduit PDUs?

Panduit PDUs come with a 3-year standard warranty, which can be extended to 5 years.

What is the maximum operating temperature?

Panduit PDUs are built with premium components to withstand 140°F (60°C) at full load.

Do Panduit PDUs feature hot-swappable controllers?

Yes, Panduit PDUs feature hot-swappable controllers that can be removed without affecting outlet status, ideal for service or repair.

What network connectivity options are available?

PDUs offer single or dual Gigabit Ethernet and serial connectivity. Some models also support Wi-Fi and Bluetooth via CNT06.

What can Panduit PDUs monitor in real-time?

Panduit PDUs provide real-time monitoring of power, environmental conditions, and cabinet security.

Are Panduit PDUs compatible with Cisco systems?

Yes, Panduit's intelligent PDUs are compatible with Cisco Nexus Dashboard software for enhanced energy savings and sustainability insights.

Do Panduit PDUs integrate with DCIM solutions?

Yes, intelligent PDUs offer integration with monitoring software for data management and analytics, with EL2P series having native Cisco Nexus Dashboard and Redfish API integration.

What is the maximum daisy chain capacity?

Daisy chain capacity varies by model, with ES2P supporting 16, G6 supporting 32, and EL2P supporting up to 64 PDUs.

What is the metering accuracy of Panduit PDUs?

Metering accuracy is ± 2% for ES2P and G6 models, and ± 0.5% for EL2P models.

How are vertical PDUs mounted?

Vertical PDUs feature tool-less mounting buttons for quick and secure attachment to rack keyhole slots, simplifying setup.

How to Install and Connect a Panduit EL2P PDU

This guide provides step-by-step instructions for safely installing, grounding, and connecting a Panduit Rack Power Distribution Unit (PDU) into a datacenter rack or cabinet. Follow all local and national electrical codes.

Estimated time: 1h

Tools needed:

#2 Phillips screwdriver, T10 Torx screwdriver, T20 Torx screwdriver, 2.5mm hex key Allen wrench

Supplies needed:

Mounting hardware (screws, cage nuts), Ground bonding cable, Star washer

  1. Review Safety Information and Prepare for Installation

    WARNING: To reduce the risk of electric shock and fire, ensure a reliable grounded connection before connecting power distribution products to AC power. Connect only to a circuit with appropriate overcurrent protection. Verify all circuit breakers are in the OFF position before connecting input power. Install the PDU in a temperature and humidity controlled, indoor environment, free of conductive contaminants. Do not overload the PDU. Allow sufficient time for the PDU to cool before handling after operation. TO ISOLATE THIS EQUIPMENT, DISCONNECT THE POWER CORD.

  2. Mount the PDU in the Rack

    For vertical PDUs, insert the pre-installed mounting buttons into the keyhole slots on the PDU mounting bracket in the rack. Secure using a #2 Phillips screwdriver to a recommended torque of 3.0Nm. For horizontal 1U/2U PDUs, install cage nuts at the desired U location(s) on the front and rear RETMA rails. Screw the mounting bracket ears into the RETMA rail surfaces. For high power units, adjust and secure mounting brackets to the PDU chassis using a 2.5mm hex key Allen wrench, tightening the socket head screws.

  3. Ground the PDU

    Connect a ground bonding cable from the external earthing screw (typically found on the surface with the outlets) on the PDU chassis to a known earthed reference terminal in the building or a grounding strip/bus bar in the rack. Ensure the conductor size meets National or Local Electrical Codes (e.g., NEC Table 250.122) based on the country of deployment.

  4. Connect the PDU to a Power Source

    WARNING: To reduce the risk of electric shock, ensure the feed circuit breaker is OFF before connecting the PDU. Verify all circuit breakers on the PDU are set to ON. Connect the PDU's input power cord to an appropriately rated and grounded branch circuit. Refer to the PDU's compliance label for input ratings and adhere to all local and national electrical codes. Turn the feed circuit breaker ON and wait for the operating system to load; the Main Menu will display on the screen when complete.

  5. Rotate the Network Controller (Optional)

    If a specific orientation of the physical ports is preferred, use a T10 Torx screwdriver to remove the two retaining screws from the network controller. Carefully disconnect the ribbon cable to prevent damage. Rotate the controller to the desired orientation and carefully reconnect the ribbon cable, ensuring no crimping or pinching. Reinstall the two screws using a T10 Torx screwdriver, torquing them to 2.2–3.1 lbf-in [0.25–0.35 N-M] to avoid metal deformation.

Frequently Asked Questions about Panduit

What environmental ratings do Panduit products have?

Panduit products feature comprehensive environmental ratings across multiple standards, including UL 508A Type 1, 2, 3, 4, 4X, 12, and 13; CSA Type 1, 2, 3, 4, 4X, 12, and 13; and NEMA Type 1, 2, 3, 4, 4X, 12, and 13. They meet IEC 60529 IP66 rating, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments, with operating temperatures ranging from -40°C to 130°C.

What certifications and standards do Panduit products comply with?

Panduit products are certified to multiple critical industry standards, including UL (Underwriters Laboratories) in the USA and Canada, CSA (Canadian Standard Association), EN IEC 61386, LVD 2006/G5/EC, and ARRA standards. Our products meet rigorous certifications for electrical safety, environmental compliance (WEEE and RoHS), and are designed to perform in extreme temperatures ranging from -55°C to 105°C, making them suitable for demanding industrial environments.

What industries and applications are Panduit products used for?

Panduit products are engineered for critical applications across multiple industries, including commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety-critical environments. Their solutions span electrical infrastructure, wire management, cable ties, power connectors, and safety systems designed to withstand extreme conditions like high vibration, temperature variations, UV exposure, and corrosive agents. Key industries include solar and wind energy, aerospace, heavy trucking, military, commercial transportation, and industrial manufacturing.

What are the main product lines offered by Panduit?

Panduit offers a comprehensive range of electrical infrastructure products including power connectors, cable ties, grounding connectors, identification products, safety solutions, terminals, cable cleats, wiring duct, and cable tie accessories. These products are engineered for industrial environments across multiple sectors like commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety applications.

What are the key features of Panduit products?

Panduit products are engineered for robust performance in heavy-duty industrial environments, featuring a comprehensive range of solutions including cable ties, power connectors, terminals, and identification products. Key features include proven quality performance, subject matter expertise, and customer-driven innovation across multiple industrial sectors such as commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety applications. The product line is designed to maximize productivity, reliability, and safety while meeting stringent industry standards.

What is Panduit's warranty policy?

Panduit provides a comprehensive Limited Product Warranty that can be fully reviewed on their official website at www.panduit.com/warranty. All Panduit products are subject to the terms, conditions, and limitations of this current warranty. Customers are advised to review the specific warranty details for their particular product, as Panduit requires buyers to determine product suitability for their intended use and assumes all associated risks.

What technical support does Panduit offer?

Panduit offers comprehensive technical support through their dedicated customer service team, accessible via phone at 1-800-777-3300. They provide expert assistance for their full range of industrial infrastructure products, including cable ties, power connectors, terminals, and identification solutions. Customers can also access additional technical resources and product information through their website at www.panduit.com.

What accessories are available for Panduit products?

Panduit offers a wide range of accessories across multiple product lines, including cable ties, cable tie accessories, cable tie tools, identification products, cable cleats, grounding connectors, and VeriSafe accessories like the VeriSafe Network Module and Insulation Piercing Connectors. For a comprehensive view of all available accessories, customers are recommended to visit www.panduit.com for the full product catalog.

How are Panduit products typically installed?

Panduit products are engineered for comprehensive installation across industrial environments, utilizing specialized tools and techniques for precise mounting. Installation methods vary by product line - from cable ties and power connectors to terminals and identification solutions - but all are designed for robust performance in heavy-duty settings. Technicians typically use Panduit's dedicated installation tools and follow manufacturer guidelines available at www.panduit.com to ensure proper fitting and maximum infrastructure reliability.