Panduit E24G03L - EL2P MSPO PDU, 30 (24) AMP, (12)C13/C15, (12)C13/C15/C19/C21, NEMA L21-30P-3M, BLACK
Panduit

E24G03L

UPC: 613056921016


Documents & Media
BrochureTechnical BulletinTechnical DrawingFull Engineering DrawingInstallation InstructionsUser ManualOwners Manual

Contact for Pricing

Overview

The Panduit E24G03L is a high-density, intelligent Power Distribution Unit (PDU) designed for critical IT infrastructure. This MSPO (Modular Smart Power Outlet) PDU features a robust 30 Amp current rating and operates at 208V/240V, providing ample power for demanding server racks and data center environments. It offers a total of 24 outlets, strategically configured to maximize space and connectivity. The unit includes 12 outlets with C13/C15 connectors and another 12 outlets supporting a wider range of connectors, including C13/C15/C19/C21. This versatile outlet configuration accommodates various power cords from servers, network switches, and other IT equipment. The PDU is equipped with a NEMA L21-30P locking plug, ensuring a secure and reliable power connection, essential for preventing accidental disconnections in high-traffic areas. Its black finish allows for discreet integration within standard rack enclosures. Manufactured by Panduit, a trusted name in network and electrical infrastructure, the E24G03L (SKU: E24G03L) is built for reliability and performance. The UNSPSC code 39121106 categorizes this product under power distribution units. This PDU is ideal for data centers, telecommunications closets, and enterprise network environments where consistent and flexible power delivery is paramount.
  • 30 Amp current rating for substantial power delivery
  • 24 total outlets: 12x C13/C15 and 12x C13/C15/C19/C21
  • NEMA L21-30P locking plug for secure connections
  • Designed for data center and IT infrastructure applications
  • Manufactured by Panduit for reliable performance

Specifications

Color
Black
Current Rating
30 (24) A
Nema Rating
NEMA L21-30P
Phase
3-Phase
Series
EL2P MSPO PDU
Standard
Nemko Listed Certificate: NA202011186, CE, UKCA, ROHS, REACH, China ROHS
Type
PDU
Package Dimensions (L x W x H)
68 IN x 11 IN x 6 IN
Package Dimensions (L x W x H)
172.72 cm x 27.94 cm x 15.24 cm
Package Weight (Imperial)
27.0000 L
Package Weight (Metric)
12.2472 kg
AC Diagnostic Tool with Interface Cable 120V20A EV12020 IC

EV12020IC

AC Diagnostic Tool with Interface Cable 120V20A EV12020 IC
Battery Pack for use with VeriSafe Access Contorl Kit VS-ACK-CPWR.

VS-ACK-BATTERY

Battery Pack for use with VeriSafe Access Contorl Kit VS-ACK-CPWR.
560SFR02 R0001

1KGT022200R0000

560SFR02 R0001
AC Diagnostic Tool with Interface Cable 208V15A EV20815 IC

EV20815IC

AC Diagnostic Tool with Interface Cable 208V15A EV20815 IC
AC Diagnostic Tool with Interface Cable 208V30A EV20830630 IC

EV20830630IC

AC Diagnostic Tool with Interface Cable 208V30A EV20830630 IC
AC Diagnostic Tool with Interface Cable 120V15A EV12015 IC

EV12015IC

AC Diagnostic Tool with Interface Cable 120V15A EV12015 IC
AC Diagnostic Tool with Interface Cable 208V20A EV20820 IC

EV20820IC

AC Diagnostic Tool with Interface Cable 208V20A EV20820 IC
AC Diagnostic Tool with Interface Cable 208V30A L630 Plug EV20830L630 IC

EV20830L630IC

AC Diagnostic Tool with Interface Cable 208V30A L630 Plug EV20830L630 IC

Frequently Asked Questions

What is the total number of outlets on the Panduit E24G03L?

The Panduit E24G03L PDU features a total of 24 outlets. These are configured as 12 outlets with C13/C15 connectors and 12 outlets supporting C13/C15/C19/C21 connectors.

What type of power plug does the E24G03L PDU use?

The Panduit E24G03L PDU is equipped with a NEMA L21-30P locking plug. This type of plug ensures a secure and reliable connection to the power source.

What is the current rating of the Panduit E24G03L PDU?

The Panduit E24G03L PDU has a current rating of 30 Amps. This allows it to deliver substantial power to connected IT equipment.

What are the different types of outlets available on this PDU?

The E24G03L PDU offers two types of outlets: 12 outlets are C13/C15 compatible, and the other 12 outlets are compatible with C13/C15/C19/C21 connectors.

How to Install a Panduit EL2P PDU

This guide provides step-by-step instructions for qualified personnel to safely install and connect a Panduit EL2P Rack Power Distribution Unit (PDU) into a datacenter rack or cabinet.

Estimated time: 45m

Tools needed:

#2 Phillips screwdriver, T10 Torx screwdriver, T20 Torx screwdriver, 2.5mm hex key Allen wrench

Supplies needed:

Mounting hardware (screws, brackets), Cage nuts (for horizontal PDU mounting), Ground bonding cable

  1. Review Safety Information and Prepare for Installation

    Before beginning, ensure you are qualified personnel. Review all safety precautions, especially regarding high leakage current and lethal voltages. Verify that devices connected to the PDU are compatible with the line voltage. Ensure all circuit breakers are in the OFF position before connecting input power. Install the PDU in a temperature and humidity controlled, indoor environment, free of conductive contaminants. Do not operate near water or excessive humidity.

  2. Mount the PDU in the Rack

    Mount the PDU into the datacenter rack or cabinet. For vertical PDUs, insert the mounting buttons into the keyhole slots on the PDU mounting bracket in the rack, then secure using a #2 Phillips screwdriver to 3.0Nm. For horizontal PDUs, install cage nuts at the desired U location on both front and rear equipment rails, then screw the mounting bracket ears into the RETMA rail surface. Use only the hardware provided for installation. Maintain a minimum clearance of 2 to 3 inches between the PDU chassis and cabinet frame for proper airflow.

  3. Ground the PDU

    Connect the external ground bonding point on the PDU chassis to the rack metalwork or a known earthed reference terminal in the building. Use a ground bonding cable with a conductor size that meets National or Local Electrical Codes (e.g., 14 AWG for up to 15A, 12 AWG for up to 20A). This supplementary Earth bonding is critical for safety.

  4. Optional: Rotate the Network Controller

    If a specific orientation for the physical ports is desired, use a T10 Torx screwdriver to remove the two retaining screws from the network controller. Carefully disconnect the ribbon cable to prevent damage. Rotate the controller to the preferred orientation, then carefully reconnect the ribbon cable, ensuring no crimping or pinching. Re-secure the controller with the two screws, torquing them to 2.2–3.1 lbf-in [0.25–0.35 N-M] to avoid metal deformation.

  5. Connect the PDU to a Power Source

    Ensure the feed circuit breaker for the power source is in the OFF position. Verify that all circuit breakers on the PDU are set to ON. Connect the PDU's input power cord to a grounded electrical outlet that is located near the equipment and is easily accessible. The outlet must be an appropriately rated branch circuit, protected by a branch circuit overcurrent protection, and adhere to all local and national electrical codes. Do not overload the PDU.

  6. Power On and Verify Operation

    Turn the feed circuit breaker for the power source to the ON position. Allow sufficient time for the PDU's operating system to load. Once complete, the Main Menu should display on the PDU's screen, indicating successful power-up. Switched (MS) and Monitored & Switched per Outlet (MSPO) PDUs will feature an LED corresponding to each outlet as it is powered on.

Frequently Asked Questions about Panduit

What environmental ratings do Panduit products have?

Panduit products feature comprehensive environmental ratings across multiple standards, including UL 508A Type 1, 2, 3, 4, 4X, 12, and 13; CSA Type 1, 2, 3, 4, 4X, 12, and 13; and NEMA Type 1, 2, 3, 4, 4X, 12, and 13. They meet IEC 60529 IP66 rating, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments, with operating temperatures ranging from -40°C to 130°C.

What certifications and standards do Panduit products comply with?

Panduit products are certified to multiple critical industry standards, including UL (Underwriters Laboratories) in the USA and Canada, CSA (Canadian Standard Association), EN IEC 61386, LVD 2006/G5/EC, and ARRA standards. Our products meet rigorous certifications for electrical safety, environmental compliance (WEEE and RoHS), and are designed to perform in extreme temperatures ranging from -55°C to 105°C, making them suitable for demanding industrial environments.

What industries and applications are Panduit products used for?

Panduit products are engineered for critical applications across multiple industries, including commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety-critical environments. Their solutions span electrical infrastructure, wire management, cable ties, power connectors, and safety systems designed to withstand extreme conditions like high vibration, temperature variations, UV exposure, and corrosive agents. Key industries include solar and wind energy, aerospace, heavy trucking, military, commercial transportation, and industrial manufacturing.

What are the main product lines offered by Panduit?

Panduit offers a comprehensive range of electrical infrastructure products including power connectors, cable ties, grounding connectors, identification products, safety solutions, terminals, cable cleats, wiring duct, and cable tie accessories. These products are engineered for industrial environments across multiple sectors like commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety applications.

What are the key features of Panduit products?

Panduit products are engineered for robust performance in heavy-duty industrial environments, featuring a comprehensive range of solutions including cable ties, power connectors, terminals, and identification products. Key features include proven quality performance, subject matter expertise, and customer-driven innovation across multiple industrial sectors such as commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety applications. The product line is designed to maximize productivity, reliability, and safety while meeting stringent industry standards.

What is Panduit's warranty policy?

Panduit provides a comprehensive Limited Product Warranty that can be fully reviewed on their official website at www.panduit.com/warranty. All Panduit products are subject to the terms, conditions, and limitations of this current warranty. Customers are advised to review the specific warranty details for their particular product, as Panduit requires buyers to determine product suitability for their intended use and assumes all associated risks.

What technical support does Panduit offer?

Panduit offers comprehensive technical support through their dedicated customer service team, accessible via phone at 1-800-777-3300. They provide expert assistance for their full range of industrial infrastructure products, including cable ties, power connectors, terminals, and identification solutions. Customers can also access additional technical resources and product information through their website at www.panduit.com.

What accessories are available for Panduit products?

Panduit offers a wide range of accessories across multiple product lines, including cable ties, cable tie accessories, cable tie tools, identification products, cable cleats, grounding connectors, and VeriSafe accessories like the VeriSafe Network Module and Insulation Piercing Connectors. For a comprehensive view of all available accessories, customers are recommended to visit www.panduit.com for the full product catalog.

How are Panduit products typically installed?

Panduit products are engineered for comprehensive installation across industrial environments, utilizing specialized tools and techniques for precise mounting. Installation methods vary by product line - from cable ties and power connectors to terminals and identification solutions - but all are designed for robust performance in heavy-duty settings. Technicians typically use Panduit's dedicated installation tools and follow manufacturer guidelines available at www.panduit.com to ensure proper fitting and maximum infrastructure reliability.