The ABB Star Teck XP STX125-469PVC is a 1-1/4" hazardous location cable fitting hub designed for secure conduit connections in explosive environments. Developed in collaboration with engineers from petrochemical, oil, and gas industries, this fitting features an easy-to-fill integral sealing chamber and a disconnectable design that minimizes cable preparation. The integral sealing chamber eliminates the need for traditional cement sealants, streamlining installation while maintaining compliance with hazardous location requirements. Compatible with PVC-jacketed cables, this fitting ensures reliable performance in Class I, II, and III, Division 1 and 2 hazardous locations. The disconnectable design allows for quick adjustments or replacements without full disassembly, reducing downtime during maintenance or system modifications. ABB’s Star Teck XP line includes complementary liquid and putty sealants, further simplifying installation and ensuring long-term reliability in demanding industrial environments.
  • 1-1/4" size for standard conduit connections
  • PVC-coated jacketed design for hazardous locations
  • Integral sealing chamber eliminates cement sealants
  • Disconnectable design for easy installation and maintenance
  • Compatible with Class I, II, III, Division 1 & 2 hazardous environments

Specifications

Application
For Hazardous Locations
Color
Black
Finish
PVC
Material
PVC
Material
Aluminum
Series
STAR TECK XP
Size
1-1/4 inches
Standard
CSA 23086
Type
Teck Cable Fittings
Package Dimensions (L x W x H)
6 IN x 4.5 IN x 3 IN
Package Dimensions (L x W x H)
15.24 cm x 11.43 cm x 7.62 cm
Package Weight (Imperial)
1.1000 L
Package Weight (Metric)
0.4990 kg
Straight Conduit Fitting, Swivel External Male Thread, Nominal Conduit Size 34mm, M32 Thread, Polyamide (Nylon) 66, Nickel Plated Brass Thread, Black

AL34/M32/SA/BL

Straight Conduit Fitting, Swivel External Male Thread, Nominal Conduit Size 34mm, M32 Thread, Polyamide (Nylon) 66, Nickel Plated Brass Thread, Black
Pull Cap, Polyethylene, Size 1 1/2 Inch

345

Pull Cap, Polyethylene, Size 1 1/2 Inch
Star Teck XP hazardous location PVC coated jacketed cable fitting hub size 1-1/2 inches Range over jacket 1.600-1.875 inches.

STX150-471PVC

Star Teck XP hazardous location PVC coated jacketed cable fitting hub size 1-1/2 inches Range over jacket 1.600-1.875 inches.
Star Teck XP hazardous location PVC coated jacketed cable fitting hub size 1-1/2 inches Range over jacket 1.500-1.625 inches.

STX150-550PVC

Star Teck XP hazardous location PVC coated jacketed cable fitting hub size 1-1/2 inches Range over jacket 1.500-1.625 inches.
Star Teck XP hazardous location PVC coated jacketed cable fitting hub size 1 inch Range over jacket 1.025-1.205 inches.

STX100-468PVC

Star Teck XP hazardous location PVC coated jacketed cable fitting hub size 1 inch Range over jacket 1.025-1.205 inches.
Star Teck XP hazardous location PVC coated jacketed cable fitting hub size 2 inches Range over jacket 1.900-2.187 inches.

STX200-473PVC

Star Teck XP hazardous location PVC coated jacketed cable fitting hub size 2 inches Range over jacket 1.900-2.187 inches.
Star Teck XP hazardous location PVC coated jacketed cable fitting hub size 2 inches Range over jacket 2.100-2.375 inches.

STX200-474PVC

Star Teck XP hazardous location PVC coated jacketed cable fitting hub size 2 inches Range over jacket 2.100-2.375 inches.
Aluminum PVC coated fitting with a hub size of 3 inches and the outer jacket diameters from 2.79 to 3.06 inches.

STX300-479PVC

Aluminum PVC coated fitting with a hub size of 3 inches and the outer jacket diameters from 2.79 to 3.06 inches.

Frequently Asked Questions

What is the size of this cable fitting hub?

The fitting hub size is 1-1/4 inches, suitable for standard conduit connections.

What hazardous location classes is this fitting rated for?

The fitting is rated for Class I, II, and III, Division 1 and 2 hazardous locations, ensuring safe operation in explosive environments.

Does this fitting require cement sealants?

No, the integral sealing chamber eliminates the need for traditional cement sealants, simplifying installation.

What cable types are compatible with this fitting?

The fitting is designed for PVC-jacketed cables, ensuring secure and reliable connections in hazardous environments.

Can this fitting be disconnected without full disassembly?

Yes, the disconnectable design allows for quick adjustments or replacements without full disassembly, reducing downtime.

How to Install the STX125-469PVC Cable Fitting

This guide provides step-by-step instructions for preparing, assembling, and sealing the STX125-469PVC cable fitting for power or shielded data cables, ensuring a secure and code-compliant installation.

Estimated time: 1h 30m

Tools needed:

Hacksaw, Strap wrenches, Wooden dowel (if using putty sealant), Gloves (PPE)

Supplies needed:

Sealing compound (SC4-KIT-1 LIQUID SEALANT or SC65 PUTTY SEALANT - purchased separately), Fiber damming material (for liquid sealant), Lubricant

  1. De-energize Circuits and Review Safety

    WARNING: Verify all circuits are de-energized before beginning installation or performing maintenance to prevent electrical shock. Ensure installation is performed by a qualified electrician in accordance with national and local electrical codes. CAUTION: For hazardous locations, these fittings must be assembled with one of the specified sealing compounds.

  2. Prepare Cable for Fitting

    Determine the required working length of conductors inside the enclosure or device. Remove a portion of the outer jacket to expose the armor, then cut the armor using a hacksaw. CAUTION: Do not nick or cut the conductor insulation.

  3. Trim Outer Jacket and Prepare Boot

    Trim the outer jacket to expose the armor strip length as indicated in the product table (1-1/4 inches for STX125-469PVC). Next, prepare the cable boot by either Method 1 (unscrew gland nut, force cable in boot, cut boot in front of cable) or Method 2 (strip cable jacket off armor, progressively cut slices off boot until it snugly slides onto the armor).

  4. Feed Cable and Secure Gland Nut

    Feed the prepared cable through the gland nut opening and push it until the cable armor firmly hits the end stop. Apply lubricant where indicated prior to tightening the gland nut. Tighten the gland nut until an appropriate seal is obtained or to the maximum torque of 1000 IN-LBS for the STX125-469PVC. Ensure the bushing seals evenly around the cable's outer jacket and the cable remains centered for an optimal seal. Use strap wrenches for PVC coated fittings.

  5. Disassemble Fitting and Prepare Conductors

    Disassemble the hub from the body sub-assembly by loosening the union, then unscrew the sealing chamber from the body sub-assembly. Trim the inner jacket to a length of 1/8" to 3/8" to expose the conductor bundle. If installing shielded data cables, additionally remove the outer (overall) shield from the conductor bundle and remove filler materials, taking care not to nick or damage inner shields.

  6. Apply Liquid Sealing Compound (SC4-KIT-1)

    This method is suitable for all power and shielded data cables. Pack fiber damming material tightly into all voids between conductors and the body, spreading strands of any uninsulated grounding conductor where applicable. Screw the sealing chamber back onto the body subassembly until it completely seats. Position the cable/fitting into a vertical position. Mix the SC4-KIT-1 sealing compound according to its package instructions and dispense it into the end of the sealing chamber until the compound level stabilizes at the top. CAUTION: Remove all excess compound material from the outside of the sealing chamber with a damp cloth.

  7. Mount Hub and Secure Assembly

    Allow the liquid sealing compound to solidify for approximately 1 hour. Once solidified, mount the hub in the desired location. Place the encapsulated assembly into the hub and secure it in position by tightening the union until it bottoms (metal-to-metal contact).

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.