Authorized ABB Distributor (Installation Products)
ABB - Installation Products SDK 1010 M - Flood-Seal Street and Highway Lighting Mechanical Fuse and Disconnect Kits, In-Line Variable-Range, non-fused, conductor range stranded 1/0-2 and solid 1/0-2

ABB Installation Products SDK 1010 M Flood-Seal Street and Highway Lighting Mechanical Fuse and Disconnect Kits, In-Line…

UPC: 783786751471


Documents & Media
Installation InstructionsManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB SDK 1010 M Flood-Seal Mechanical Fuse and Disconnect Kit offers a robust in-line connection solution for street and highway lighting and other electrical systems. This non-fused unit is designed for direct conductor integration, accommodating a conductor range of 1/0 AWG to 2 AWG for both stranded and solid copper conductors. This kit facilitates mechanical connection and disconnection of circuits, crucial for maintenance, repair, or system modifications. The in-line configuration ensures a compact and efficient integration into existing wiring runs. The SDK 1010 M is built to meet the practical demands of utility and municipal electrical installations. The SDK 1010 M is designed for secure and dependable electrical connections in critical infrastructure. Ensure proper installation according to manufacturer guidelines for optimal performance and safety. UNSPSC Code: 39121421.
  • ABB SDK 1010 M Flood-Seal Mechanical Disconnect Kit
  • Non-fused, in-line configuration
  • Accommodates 1/0-2 AWG stranded and solid copper conductors
  • Padlockable (when open) and sealable (when closed)

Specifications

Application
Rated 600 Volts, 30 Amps Maximum, perfect for heavy-duty applications
Conductor Range
1/0 to #2 STR/SOL AWG
Connection
Mechanical
Insulation
True
Material
EPDM-Rubber Housing
Number of Conductors
2
Special Features
EPDM Rubber housing ensures a fully insulated, watertight and submersible connection. Safe separations - fuse or connecting link stays in load side when separated. Dual-rated and approved for a wide range of Aluminum or Copper Conductors
Type
Breakaway Street Light Kit Non-Fused
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
Flood-Seal Street and Highway Lighting Mechanical Fuse and Disconnect Kits, In-Line Variable-Range, fused, conductor range stranded 1/0-2, and solid 1/0-2

SLK 1010 M

Flood-Seal Street and Highway Lighting Mechanical Fuse and Disconnect Kits, In-Line Variable-Range, fused, conductor range stranded 1/0-2, and solid 1/0-2
Flood-Seal Street and Highway Lighting Mechanical Fuse and Disconnect Kits, In-Line Variable-Range, non-fused, conductor range stranded 2-14, and solid 2-14

SDK 22 M

Flood-Seal Street and Highway Lighting Mechanical Fuse and Disconnect Kits, In-Line Variable-Range, non-fused, conductor range stranded 2-14, and solid 2-14
Aluminum Flood-Seal Mechanical Splice Two-Wire Kits, conductor range 2-500 connector length 4 3/16 inch, screws per side 2

USK 500

Aluminum Flood-Seal Mechanical Splice Two-Wire Kits, conductor range 2-500 connector length 4 3/16 inch, screws per side 2
Aluminum Flood-Seal Mechanical Splice Three-Wire Kits, conductor range side A 6-350, side B 1/0-4/0 with 6-14 solid tap, outlets accommodate 3 Wires

USK 4/0 SL

Aluminum Flood-Seal Mechanical Splice Three-Wire Kits, conductor range side A 6-350, side B 1/0-4/0 with 6-14 solid tap, outlets accommodate 3 Wires
Aluminum Flood-Seal Mechanical Splice Two-Wire Kits, conductor range 4-4/0 connector length 2in, screws per side 1

USK 4/0

Aluminum Flood-Seal Mechanical Splice Two-Wire Kits, conductor range 4-4/0 connector length 2in, screws per side 1
Aluminum Flood-Seal Mechanical Splice Two-Wire Kits, conductor range 6-350 connector length 18 inch, screws per side 1

USK 350-18

Aluminum Flood-Seal Mechanical Splice Two-Wire Kits, conductor range 6-350 connector length 18 inch, screws per side 1
Aluminum Flood-Seal Mechanical Splice Two-Wire Kits, conductor range 6-350 connector length 4 inch, screws per side 1

USK 350-4

Aluminum Flood-Seal Mechanical Splice Two-Wire Kits, conductor range 6-350 connector length 4 inch, screws per side 1
Flood-Seal Street and Highway Lighting Mechanical Fuse and Disconnect Kits-In-Line, fused, conductor range stranded 12,10,8,6,4 and solid 12,10,8,6,4

SLK-M

Flood-Seal Street and Highway Lighting Mechanical Fuse and Disconnect Kits-In-Line, fused, conductor range stranded 12,10,8,6,4 and solid 12,10,8,6,4

How to Install the Flood-Seal Street Light Fuse Kit (SDK 1010 M)

This guide provides step-by-step instructions for the safe and proper installation of the Flood-Seal Street Light Fuse Kit (SDK 1010 M), including cable preparation, wiring, and assembly procedures for a watertight seal.

Estimated time: 45m

Tools needed:

Wire strippers, Torque screwdriver (25 in-lbs), Utility knife or cutter, Cleaning cloth

Supplies needed:

SDK 1010 M Kit (includes line-end assembly, load-end assembly, connecting link), 2 FSS 20 "Flood-Seal" Rockets, Silicone grease packet, Line-end cable, Load-end cable

  1. De-energize Wires and Identify Components

    WARNING: Ensure all associated wires and the working area are completely de-energized to prevent electric shock. CAUTION: Identify the line-side and load-side wires and match them with the corresponding housing body parts before proceeding with installation.

  2. Prepare Cable Ends

    Strip 3/4 inch of insulation from the conductor end of both the line-end and load-end cables. Wipe both cable ends clean. Pencil the end of the cable insulation for easier insertion into the housing.

  3. Prepare Line-End Housing

    Select the correct cut-off ring on the line-end housing that matches the cable size being used. Cut off the end housing at the tip of the arrow, ensuring only the correct cable size is showing. Apply silicone grease to the end of the cable and to the cut opening of the line-end housing. IMPORTANT: Do NOT grease the sealing rings on the line-end housing.

  4. Insert Line-End Cable and Secure

    Insert the prepared line-end cable into the line-end assembly until it extends 2 to 3 inches beyond the housing. Torque the set screw to 25 in-lbs to secure the cable.

  5. Prepare Load-End Housing and Insert Connecting Link

    Apply silicone grease to the sealing area of the load-end assembly. For SDK Kits (like SDK 1010 M), insert the provided connecting link into the load-end assembly. Do not use a fuse for SDK kits.

  6. Insert Load-End Cable and Secure

    Insert the prepared load-end cable into the load-end assembly until it extends 2 to 3 inches beyond the housing. Torque the set screw to 25 in-lbs to secure the cable.

  7. Assemble and Seal the Housings

    Mate the line-end housing to the load-end housing to establish the electrical connection. Mate the "Flood-Seal" Rocket to the line-end assembly to create a watertight seal.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.