ABB - Installation Products R2T35M2H0240 - Outdoor Ranger2 Cable Termination. 35kV, Cable Type - Tape Shield/Wire Shield/UniShield. Insulation Range - .84 inch - 1.38 inch. Aluminum 1-Hole Spade #2-500 kcmil, Conductor 1/0 Stranded/Compressed AWG or 2/0 Compact/Solid AWG

ABB Installation Products R2T35M2H0240 Outdoor Ranger2 Cable Termination. 35kV, Cable Type - Tape Shield/Wire Shield/UniShield.…

UPC: 075114426558


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB R2T35M2H0240 Outdoor Ranger2 Cable Termination delivers reliable medium-voltage power distribution up to 35kV in outdoor environments. Engineered for compatibility with tape shield, wire shield, and UniShield cable constructions, this termination supports a broad range of shielded medium-voltage cables with insulation diameters from 0.84 inches to 1.38 inches. The included aluminum 1-hole spade connector accommodates conductors from #2 AWG to 500 kcmil, including 1/0 AWG stranded/compressed and 2/0 AWG compact/solid configurations. Designed for maximum field performance, the R2T35M2H0240 features a non-tracking silicone housing with superior weathering characteristics and eight sheds for enhanced creepage and strike distances. The shrink-fit housing simplifies installation with common procedures and field-removable center core, while pull-down tabs ensure easy jacket seal deployment. This termination installs in restricted spaces and permits free-hanging applications, making it ideal for utility, industrial, and commercial power distribution systems. Key electrical ratings include a maximum design voltage to ground of 22 kV, coronal extinction voltage of 30 kV (≤3pC), and lightning impulse withstand of 200 kV crest. The unit meets 10-second wet withstand of 80 kV, 1-minute dry withstand of 90 kV, and 5-hour dry withstand of 75 kV. Optional insulating silicone sleeves are available for increased creepage or wildlife protection. Its compact design and field-proven technology reduce inventory complexity with just two sizes covering the full cable range from #2 AWG to 1250 kcmil.
  • Supports 35kV outdoor medium-voltage applications with tape shield, wire shield, and UniShield cable constructions
  • Accommodates insulation diameters from 0.84" to 1.38" and conductors from #2 AWG to 500 kcmil
  • Non-tracking silicone housing with eight sheds for superior creepage and strike distances
  • Shrink-fit technology with field-removable center core for simplified installation
  • Rated for lightning impulse withstand of 200 kV crest and 10-second wet withstand of 80 kV

Specifications

Application
Cable Termination, Outdoor Application, 35kV
Color
Gray
Conductor Size
1/0 STR/COMPR AWG , 2/0 COMPT/SOL AWG
Connection Type
1-Hole Spade
Earthing
Products Includes Their Own Grounding System
Material
Aluminum
Mounting
Product Need to have Cable Holder (not included)
Number Of Terminals
(1) Single Phase
Series
Ranger2
Size
0.84-1.38 inch Insulation, #2-500 kcmil Spade
Special Features
Silicone Rubber Housing. Lightweight, Compact Design. Pull-Down Tabs for Easy Installation. Thick Wall Construction
Standard
IEEE 48
Type
Cable Termination - Outdoor - Ranger2
Voltage Rating
35 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
Ranger2 Termination. Type - Outdoor, 35kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - .84 inch - 1.38 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 270 -Stranded or Compressed 4/0 Compact or Solid 250.

R2T35J2-N0270

Ranger2 Termination. Type - Outdoor, 35kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - .84 inch - 1.38 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 270 -Stranded or Compressed 4/0 Compact or Solid 250.
Ranger2 Termination. Type - Outdoor, 28kV, Cable Type - Tape Shield/Wire Shield/ Unshield, Insulation Range - .84 inch - 1.38 inch, Connector Type - Tinned Aluminum 1-Hole Spade #2-500 kcmil, Conductor Code - 300 -Stranded or Compressed 350 kcmil, Compact or Solid 400 kcmil.

R2T28M2-H0300

Ranger2 Termination. Type - Outdoor, 28kV, Cable Type - Tape Shield/Wire Shield/ Unshield, Insulation Range - .84 inch - 1.38 inch, Connector Type - Tinned Aluminum 1-Hole Spade #2-500 kcmil, Conductor Code - 300 -Stranded or Compressed 350 kcmil, Compact or Solid 400 kcmil.
69kV, Transmission Cable Terminator, Base and Top Module, Housing Size 1 (Bore Diameter 1.55 inch, Insulation Range 1.65 to 1.9 inch), Connection Type - 2-Hole NEMA, Connector Type - Aluminum, Conductor Size Code 41P - 1.101 to 1.152 inch, Metallic Screen Kit - 1/0 Bonding Cable 6 foot with Two Split Bolts, Armor Kit - Heat Shrink, No Bracket Required

69TCT212141PBBN

69kV, Transmission Cable Terminator, Base and Top Module, Housing Size 1 (Bore Diameter 1.55 inch, Insulation Range 1.65 to 1.9 inch), Connection Type - 2-Hole NEMA, Connector Type - Aluminum, Conductor Size Code 41P - 1.101 to 1.152 inch, Metallic Screen Kit - 1/0 Bonding Cable 6 foot with Two Split Bolts, Armor Kit - Heat Shrink, No Bracket Required
Ranger2 Termination for 35KV outdoor application, cable insulation diameter 1.30 - 2.10 inches for Concentric Neutral and Jacketed Concentric Neutral Cable, includes Aluminum 2-Hole Spade connector for #2-1250 kcmil, Stranded or Compressed 1250.

R2T35J4-N0440

Ranger2 Termination for 35KV outdoor application, cable insulation diameter 1.30 - 2.10 inches for Concentric Neutral and Jacketed Concentric Neutral Cable, includes Aluminum 2-Hole Spade connector for #2-1250 kcmil, Stranded or Compressed 1250.
Ranger2 Termination. Type - Indoor, 15kV, Cable Type - Tape Shield/Wire Shield/ Unshield, Insulation Range - .64 inch - 1.12 inch, Connector Type - Copper 2-Hole Spade #2-1250 kcmil, Conductor Code - 240 -Stranded or Compressed 1/0 Compact or Solid 2/0. Cable Mounting Bracket - Stainless Steel, 0.80 to 1.25 inch.

R2IT15M1-N2240-B1

Ranger2 Termination. Type - Indoor, 15kV, Cable Type - Tape Shield/Wire Shield/ Unshield, Insulation Range - .64 inch - 1.12 inch, Connector Type - Copper 2-Hole Spade #2-1250 kcmil, Conductor Code - 240 -Stranded or Compressed 1/0 Compact or Solid 2/0. Cable Mounting Bracket - Stainless Steel, 0.80 to 1.25 inch.
69kV, Transmission Cable Terminator, Base and Two Top Module, Housing Size 0 with Bore Diameter 1.35 inch with Insulation Range of 1.45 to 1.7 inch, Connection Type 2 - 2 Hole NEMA, Connector Type - Copper, Conductor Size Code 33P: 0.781 - 0.815 inch, Metallic Screen Kit - Not Required, Armor Kit - Jacketing Tape and Mastic, No Bracket Required

69TCT302233PNAN

69kV, Transmission Cable Terminator, Base and Two Top Module, Housing Size 0 with Bore Diameter 1.35 inch with Insulation Range of 1.45 to 1.7 inch, Connection Type 2 - 2 Hole NEMA, Connector Type - Copper, Conductor Size Code 33P: 0.781 - 0.815 inch, Metallic Screen Kit - Not Required, Armor Kit - Jacketing Tape and Mastic, No Bracket Required
Ranger2 Termination for 25/28KV outdoor application, cable insulation diameter 1.30 - 2.10 for Concentric Neural and Jacketed Concentric Neutral Cable, includes Aluminum 2-Hole Spade connector for #2-1250 kcmil, Conductor 500 Stranded/Compressed or 600 Compact/Solid

R2T28J4-N0330

Ranger2 Termination for 25/28KV outdoor application, cable insulation diameter 1.30 - 2.10 for Concentric Neural and Jacketed Concentric Neutral Cable, includes Aluminum 2-Hole Spade connector for #2-1250 kcmil, Conductor 500 Stranded/Compressed or 600 Compact/Solid
Ranger2 Termination. Type - Outdoor, 28kV, Cable Type - Tape Shield/Wire Shield/ Unshield, Insulation Range - 1.30 inch - 2.10 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 460 -Stranded or Compressed 1500 Compact or Solid 1600.

R2T28M4-N0460

Ranger2 Termination. Type - Outdoor, 28kV, Cable Type - Tape Shield/Wire Shield/ Unshield, Insulation Range - 1.30 inch - 2.10 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 460 -Stranded or Compressed 1500 Compact or Solid 1600.

Frequently Asked Questions

What cable insulation diameters does it support?

The R2T termination covers cable insulation diameters from 0.84 in (21.3 mm) to 2.10 in (53 mm). It accommodates #2 AWG through 1250 kcmil cables.

What sizes are available for the R2T35 termination?

The R2T35 termination is available in sizes 2 and 4.

Where can I find installation instructions for R2T35?

Installation instructions are available as IS-1143 for R2T35J, IS-1144 for R2T35M, and IS-1145 for R2T35L.

How many sheds does the 35 kV outdoor model have?

The 35 kV outdoor model of the R2T35 termination has eight sheds.

What is the minimum strike distance?

The minimum strike distance for the R2T35 termination is 16.8 in (427 mm).

What is the maximum altitude for operation?

The maximum altitude for operation of the R2T35 termination is 3300 feet (1005 m).

What are the mounting options for the R2T35?

The R2T35 termination can be mounted free hanging or with an optional bracket.

What is the compatible power system frequency?

The R2T35 termination is compatible with a power system frequency range of 48 to 62 Hz.

What is the operating ambient temperature range?

The R2T35 termination operates within an ambient temperature range of -22 to +149 °F (-30 to +65 °C).

What is the maximum design voltage to ground?

The maximum design voltage to ground for the R2T35 termination is 22 kV.

How to Install the R2T35M2 35kV Ranger 2 Shrink-Fit Silicone Rubber Termination for Tape Shielded Cable

This guide provides step-by-step instructions for the installation of the R2T35M2 35kV Ranger 2 Shrink-Fit Silicone Rubber Termination on tape shielded cables. All apparatus must be de-energized during installation. This product should be installed only by competent personnel trained in high voltage safety practices.

Estimated time: 1h 30m

Tools needed:

Cable preparation tools, Crimping tool, Vinyl tape, Approved solvent and cleaning pads, Aluminum oxide abrasive (120 grit or finer, optional), Gloves

Supplies needed:

Silicone Rubber Termination Halves (R2T35M2), Silicone Lubricant, Gray Silicone Rubber Electrical Tape, Constant Force Spring, Preformed Ground Braid, Sealing Mastic, Copper Foil Tape, Terminal Lug/Connector (compatible with 35kV cable)

  1. Prepare the Cable for Termination

    Verify the cable size fits within the insulation range specified in the Termination Selection Chart. Train the cable into position and cut it to the required length. Prepare the cable using the specified dimensions for jacket removal, terminal lug depth, and insulation. To prevent the tape shield from unrolling, secure its edge with a single wrap of the supplied copper foil tape. Allow for additional exposed conductor distance to account for growth during crimping of aluminum lugs or connectors.

  2. Install the Ground Braid Assembly

    Carefully wrap one band of mastic around the cable jacket 1/4 inch (6mm) from the jacket end, using 50% stretch, and cut it flush without overlapping. Position the preformed ground braid with the short tail over the tape shield and the solder block centered over the mastic strip. Secure the ground braid to the cable jacket using vinyl tape and press the solder block into the mastic. Apply a second mastic band over the solder block and previous mastic, maintaining the 1/4 inch (6mm) dimension, and cut it flush. Wrap two half-lapped layers of vinyl tape around the mastic seal. Wrap the ground braid around the cable tape shield one complete wrap, trim any excess, and secure it in place with the constant force spring, wrapping in the same direction. Cinch the spring after the final winding and secure it with two wraps of vinyl tape. For cloth or paper semi-conductive shields, overwrap with one half-lapped layer of highly stretched semi-conductive rubber tape.

  3. Install the Terminal Lug or Connector

    Check to ensure the termination assembly fits over the selected lug. If it does not, clean the insulation and slide the termination onto the cable before installing the lug. Position the connector or lug and crimp it according to the manufacturer’s directions, ensuring not to crimp the last 3/8 inch to 1/2 inch of the connector. Remove any excess oxide inhibitor and all sharp crimp flashings and edges after crimping.

  4. Clean Cable Insulation and Lug Barrel

    Wipe the cable insulation with an approved solvent, taking care not to allow the solvent to touch the semi-conductive insulation shield. If abrasive material must be used, apply it only to the insulation, not the semi-conductive insulation shield. Use only aluminum oxide abrasive, grit 120 or finer, and be careful not to reduce the cable insulation diameter below the kit's allowed range.

  5. Install the Silicone Rubber Termination Body

    Create a track-resistant moisture seal between the termination insulator and the lug/connector by wrapping a band of gray silicone rubber electrical tape around the base of the terminal lug. Cover the edge of the semi-conductive insulation shield with a liberal coating of silicone grease. For the lower termination with a fold-down skirt, pull the loose end of the removable core through the top until it is flush with the bottom. Slide the termination body onto the cable, aligning it with the forward edge of the mastic seal. Carefully remove the core by unwinding it counter-clockwise, ensuring the termination body (not the core) is butted against the leading edge of the mastic seal. Using the second housing, pull the core down within one coil of the bottom, slide the termination over the cable, and pull the core counter-clockwise, overlapping the first termination by 1-1/2 inches (40mm). Apply a thin film of silicone lubricant to the skirt and mastic seal area (do not lubricate skirt tabs) and carefully fold down the skirt over the mastic seal. Complete the lug area moisture seal using the remaining gray silicone rubber electrical tape, overlapping the termination insulator by approximately 1 inch and extending over a non-crimped region of the lug/connector barrel with a half-lap configuration. Connect the ground braid to the system ground and confirm that the High-K step does not exceed 1.5 inches.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.