Authorized ABB Distributor (Installation Products)
ABB - Installation Products R2T35J2-T0240-B2 - Ranger2 Termination. Type - Outdoor, 35kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - .84 inch - 1.38 inch, Connector Type - Universal Aluminum Barrel for AL or CU Condutor with Copper Wire Lead #2-4/0, Conductor Code - 240 -Stranded or Compressed 1/0 Compact or Solid 2/0. Cable Mounting Bracket - B2 - Stainless Steel - Size 1.10 inch - 1.50 inch.

ABB Installation Products R2T35J2-T0240-B2 Ranger2 Termination. Type - Outdoor, 35kV, Cable Type - Concentric Neutral/Jacketed…

UPC: 783786346905


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB Ranger2 Termination, SKU R2T35J2-T0240-B2, is engineered for outdoor 35kV applications. This termination is designed for Concentric Neutral and Jacketed Concentric Neutral cable types. It accommodates insulation diameters ranging from 0.84 inches to 1.38 inches, providing a secure fit for a variety of cable constructions. The universal aluminum barrel is compatible with both aluminum (AL) and copper (CU) conductors. It features a copper wire lead suitable for conductor sizes #2 AWG through 4/0 AWG. The conductor code 240 specifies compatibility with stranded or compressed 1/0 AWG compact conductors, or solid 2/0 AWG conductors. The integrated B2 cable mounting bracket is constructed from stainless steel and is sized to fit cables with diameters between 1.10 inches and 1.50 inches, ensuring stable and reliable installation in outdoor environments. This termination system is part of ABB's Installation Products offering, designed for efficient and dependable power distribution infrastructure.
  • Outdoor 35kV termination for Concentric Neutral/Jacketed Concentric Neutral cables
  • Insulation range: 0.84 inch - 1.38 inch
  • Universal aluminum barrel for AL or CU conductors with copper wire lead (#2-4/0 AWG)
  • Conductor compatibility: Stranded/compressed 1/0 AWG compact or solid 2/0 AWG
  • Stainless steel B2 mounting bracket (1.10" - 1.50" size)

Specifications

Application
Cable Termination, Outdoor Application, 35kV
Cable Type
Concentric Neutral Wire
Color
Gray
Conductor Size
1/0 STR AWG , 1/0 COMPR AWG , 2/0 SOL AWG , 2/0 COMPT AWG
Connection Type
Universal Aluminum Barrel for AL or CU Conductor with Copper Wire Lead #2-4/0
Earthing
Products Includes Their Own Grounding System
Material
Aluminum, Copper
Mounting
Product Need to have Cable Holder (not included)
Mounting Type
Stainless Steel Bracket
Number Of Terminals
(1) Single Phase
Series
Ranger2
Size
1.10 inch - 1.50 inch
Special Features
Silicone Rubber Housing. Lightweight, Compact Design. Pull-Down Tabs for Easy Installation. Thick Wall Construction
Standard
IEEE 48
Type
Cable Termination - Outdoor - Ranger2
Voltage Rating
35 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
Ranger2 Termination. Type - Outdoor, 35kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - .84 inch - 1.38 inch, Connector Type - Aluminum 1-Hole Spade #2-500 kcmil, Conductor Code - 240 -Stranded or Compressed 1/0 Compact or Solid 2/0.

R2T35J2-H0240

Ranger2 Termination. Type - Outdoor, 35kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - .84 inch - 1.38 inch, Connector Type - Aluminum 1-Hole Spade #2-500 kcmil, Conductor Code - 240 -Stranded or Compressed 1/0 Compact or Solid 2/0.
Ranger2 Termination. Type - Outdoor, 28kV, Cable Type - Tape Shield/Wire Shield/ Unshield, Insulation Range - 1.30 inch - 2.10 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 410 -Stranded or Compressed 1000 Compact or Solid N/A.

R2T28M4-N0410

Ranger2 Termination. Type - Outdoor, 28kV, Cable Type - Tape Shield/Wire Shield/ Unshield, Insulation Range - 1.30 inch - 2.10 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 410 -Stranded or Compressed 1000 Compact or Solid N/A.
Ranger2 Termination for 25/28KV outdoor application, cable insulation diameter 1.30 - 2.10 inches for Tape Shield, Wire Shield, and Unshielded Cable, includes Universal Aluminum Barrel For Aluminum or Copper Conductor with copper wire lead #2-4/0, Stranded or Compressed #2 /Compact or Solid #1, Stainless Steel Mounting Bracket 1.10 inch - 1.50 inch

R2T28M4-T0220-B2

Ranger2 Termination for 25/28KV outdoor application, cable insulation diameter 1.30 - 2.10 inches for Tape Shield, Wire Shield, and Unshielded Cable, includes Universal Aluminum Barrel For Aluminum or Copper Conductor with copper wire lead #2-4/0, Stranded or Compressed #2 /Compact or Solid #1, Stainless Steel Mounting Bracket 1.10 inch - 1.50 inch
Ranger2 Termination. Type - Outdoor, 35kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - .84 inch - 1.38 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 270 -Stranded or Compressed 4/0 Compact or Solid 250.

R2T35J2-N0270

Ranger2 Termination. Type - Outdoor, 35kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - .84 inch - 1.38 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 270 -Stranded or Compressed 4/0 Compact or Solid 250.
Ranger2 Termination for 25/28KV outdoor application, cable insulation diameter 1.30 - 2.10 inches for Concentric Neutral/Jacketed Concentric Neutral Cable, includes Universal Aluminum Barrel For Aluminum or Copper Conductor with copper wire lead #2-4/0, Stranded or Compressed 3/0 /Compact or Solid 4/0

R2T28J4-T0260

Ranger2 Termination for 25/28KV outdoor application, cable insulation diameter 1.30 - 2.10 inches for Concentric Neutral/Jacketed Concentric Neutral Cable, includes Universal Aluminum Barrel For Aluminum or Copper Conductor with copper wire lead #2-4/0, Stranded or Compressed 3/0 /Compact or Solid 4/0
Ranger2 Termination for 15KV outdoor application, cable insulation diameter .64 - 1.12 inches for Concentric Neural and Jacketed Concentric Neutral Cable, includes Aluminum 2-Hole Spade connector for #2 to 1250 kcmil. 1/0 Stranded or 2/0 Solid

R2T15J1-N0240

Ranger2 Termination for 15KV outdoor application, cable insulation diameter .64 - 1.12 inches for Concentric Neural and Jacketed Concentric Neutral Cable, includes Aluminum 2-Hole Spade connector for #2 to 1250 kcmil. 1/0 Stranded or 2/0 Solid
Ranger2 Termination for 28KV indoor application, cable insulation diameter .84 - 1.38 inches for Cable Type - Tape Shield, Wire Shield, and Unshielded Cable, Aluminum 2-Hole Spade #2-1250kcmil, Conductor Code 210 - Compact or Solid #2.

R2T28M2-N0210

Ranger2 Termination for 28KV indoor application, cable insulation diameter .84 - 1.38 inches for Cable Type - Tape Shield, Wire Shield, and Unshielded Cable, Aluminum 2-Hole Spade #2-1250kcmil, Conductor Code 210 - Compact or Solid #2.
Ranger2 Termination for 35KV outdoor application, cable insulation diameter .84 - 1.38 inches for Concentric Neural and Jacketed Concentric Neutral Cable, includes Universal Aluminum Barrel For Aluminum or Copper Conductor with copper wire lead, Stranded or Compressed 2/0 /Compact or Solid 3/0

R2T35J2-T0250

Ranger2 Termination for 35KV outdoor application, cable insulation diameter .84 - 1.38 inches for Concentric Neural and Jacketed Concentric Neutral Cable, includes Universal Aluminum Barrel For Aluminum or Copper Conductor with copper wire lead, Stranded or Compressed 2/0 /Compact or Solid 3/0

Frequently Asked Questions

What cable sizes does the R2T35 termination support?

The R2T35 termination supports insulation diameters from 0.84 in (21.3 mm) to 2.10 in (53 mm), covering #2 AWG through 1250 kcmil cables.

What type of housing does the R2T35 termination use?

The R2T35 termination uses a non-tracking silicone housing, offering superior memory and weathering characteristics.

How can the R2T35 termination be mounted?

The R2T35 termination can be mounted either free hanging or with an optional bracket.

Does the R2T35 termination support optional connectors?

Yes, optional connectors are available with a copper stem, one-hole, and two-hole spade connector.

How many sheds does the 35 kV outdoor model have?

The 35 kV outdoor model of the R2T35 termination has eight sheds.

What is the creepage distance of the R2T35 termination?

The creepage distance for the R2T35 termination is 30.0 in (762 mm).

What is the maximum altitude for R2T35 installation?

The R2T35 termination can be installed at a maximum altitude of 3300 feet (1005 m).

What is the Lightning Impulse Withstand Voltage (BIL)?

The Lightning Impulse Withstand Voltage (BIL Dry 110 Withstand) is 200 kV Crest.

What is the maximum design voltage to ground for R2T35?

The maximum design voltage to ground for the R2T35 termination is 22 kV.

What cable types are compatible with R2T35 terminations?

R2T35 units accommodate popular XLP and EPR cable types and various shield constructions.

How to Install the R2T35J2-T0240-B2 35kV Cable Terminator

Step-by-step guide for installing the R2T35J2-T0240-B2 35kV Ranger 2 Cable Terminator on concentric and jacketed concentric neutral cables.

Estimated time: 45m

Tools needed:

Screwdriver, Wire strippers, Approved solvent, Aluminum oxide abrasive (grit 120 or finer, if needed)

Supplies needed:

Silicone Rubber Termination Halves, Lubricant, Strips Grey Silicone Rubber Tape, Strips Sealing Mastic, Gloves, Vinyl tape or binding wire, Terminal lug (if not included), System ground connection

  1. Prepare the Cable

    Verify the cable size is within the kit's range. Train the cable into position and cut to the required length, ensuring sufficient neutral wire length for grounding. Prepare the cable according to the specified dimensions, allowing for terminal lug depth and extra exposed conductor for crimping. Wrap one band of mastic around the cable jacket 1/4" (6mm) from the end, cut flush. Bend neutral wires back over the mastic and secure them to the cable jacket 4-6" (100-150mm) from the cut edge using vinyl tape or binding wire. Apply a second mastic band over the neutral wires and the first mastic, cut flush. Wrap two half-lapped layers of vinyl tape around the mastic seal, maintaining the 1/4" (6mm) dimension.

  2. Install Lug or Connector

    If using the included lug or connector, position it and crimp according to the manufacturer's directions. Do not crimp the last 1/4" to 3/8" of the connector. Remove excess oxide inhibitor and sharp crimp flashings. If a different lug is used and does not fit through the termination core, slide the termination onto the cable before installing the lug. Do not remove the core at this time.

  3. Clean Cable Insulation and Lug Barrel

    Wipe the cable insulation with an approved solvent, avoiding contact with the semi-conductive insulation shield. If abrasive is necessary, use only aluminum oxide abrasive (grit 120 or finer) on the insulation only, being careful not to reduce the cable insulation diameter below the kit's allowance.

  4. Install Termination - First Housing

    Wrap a band of gray silicone rubber tape around the base of the terminal lug to create a track-resistant moisture seal. The tape band should not exceed 2 layers if the barrel diameter is equal to or greater than the cable primary insulation. If the barrel diameter is smaller, use the tape strip to form a band equal to the insulation diameter. Apply a liberal coating of silicone grease to the edge of the semi-conductive insulation shield to fill the step at the cut-off. For the lower termination with a fold-down skirt, pull the loose end of the removable core through the top until it is flush with the bottom. Slide the termination body onto the cable, aligning it with the forward edge of the mastic seal. Carefully remove the core by unwinding counter-clockwise, ensuring the termination body, not the core, is butted against the mastic seal. Do not push or pull on the termination assembly during core removal.

  5. Install Termination - Second Housing

    Using the second housing, carefully pull the core down to within 1 coil of the bottom. Slide the terminator over the cable and carefully pull the core counterclockwise. Overlap the first terminator by 1-1/2" (40mm).

  6. Complete Termination Sealing

    Apply a thin film of silicone lubricant to the skirt and mastic seal area (do not lubricate skirt tabs). Carefully fold down the skirt over the mastic seal. Complete the lug area moisture seal using the remaining gray silicone rubber tape, overlapping the termination insulator by approximately 1" and extending the tape wrapping over a non-crimped region of the lug/connector barrel in a half-lap configuration. Confirm that the High-K step does not exceed 1.5".

  7. Connect Ground

    Twist the concentric neutral wires together and connect them to the system ground.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.