ABB Installation Products R2T28J4-T0260 Ranger2 Termination for 25/28KV outdoor application, cable insulation diameter 1.30…
UPC: 783786812806
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- Terminates 25/28kV concentric neutral and jacketed concentric neutral cables
- Insulation diameter range: 1.30 to 2.10 inches
- Universal aluminum barrel for aluminum or copper conductors (3/0 stranded/compressed, 4/0 compact/solid)
- Includes copper wire lead #2-4/0 for grounding and continuity
- Designed for outdoor applications with environmental durability
Specifications
Application | Cable Termination, Outdoor Application, 28kV |
Cable Type | Concentric Neutral Wire |
Color | Gray |
Conductor Size | 360 kcmil , 4/0 AWG |
Earthing | Products Includes Their Own Grounding System |
Mounting | Product Need to have Cable Holder (not included) |
Number Of Terminals | (1) Single Phase |
Special Features | Silicone Rubber Housing. Lightweight, Compact Design. Pull-Down Tabs for Easy Installation. Thick Wall Construction |
Standard | IEEE 48 |
Type | Cable Termination - Outdoor - Ranger2 |
Voltage Rating | 28 kV |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 1.0000 L |
Package Weight (Metric) | 0.4540 kg |

R2T28M2-N0260
Ranger2 Termination for 25/28KV outdoor application, cable insulation diameter .84 - 1.38 inches for Tape Shield, Wire Shield, and Unshielded Cable, includes Aluminum 2-Hole Spade connector for #2-1250 kcmil, Stranded or Compressed 3/0 /Compact or Solid 4/0
R2T15J1-N0240
Ranger2 Termination for 15KV outdoor application, cable insulation diameter .64 - 1.12 inches for Concentric Neural and Jacketed Concentric Neutral Cable, includes Aluminum 2-Hole Spade connector for #2 to 1250 kcmil. 1/0 Stranded or 2/0 Solid
R2T28M2-N0210
Ranger2 Termination for 28KV indoor application, cable insulation diameter .84 - 1.38 inches for Cable Type - Tape Shield, Wire Shield, and Unshielded Cable, Aluminum 2-Hole Spade #2-1250kcmil, Conductor Code 210 - Compact or Solid #2.
R2T35J2-T0250
Ranger2 Termination for 35KV outdoor application, cable insulation diameter .84 - 1.38 inches for Concentric Neural and Jacketed Concentric Neutral Cable, includes Universal Aluminum Barrel For Aluminum or Copper Conductor with copper wire lead, Stranded or Compressed 2/0 /Compact or Solid 3/0
R2T15J1-T0250-B1
Outdoor, Ranger2 Termination, 15kV, Concentric Neutral/Jacketed Concentric Neutral Cable Type, Insulation Range - .64-1.12 inch (16-28mm). Connector Type Universal Aluminum Barrel for AL or CU Conductor with Copper Wire Lead #2-4/0. Conductor - 2/0 Stranded/Compressed or 3/0 Compact/Solid. Cable Mounting Bracket Material - Stainless Steel, Size .80-1.25 inch (20-32mm).
R2T28J4-N0380-B3
Ranger2 Termination. Type - Outdoor, 28kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - 1.30 inch - 2.10 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 380 -Stranded or Compressed 750 Compact or Solid 900. Cable Mounting Bracket - B3 - Stainless Steel - Size 1.45 inch - 1.95 inch.
R2T28J2-T0230
Ranger2 Termination for 25/28KV outdoor application, cable insulation diameter .84 - 1.38 for Concentric Neural and Jacketed Concentric Neutral Cable, includes Universal Aluminum Barrel For AL or CU Conductor w/copper wire lead #2 to 4/0. #1 Stranded to 1/0 Solid
R2T28J4-N2410-B4
Ranger2 Termination for 25/28KV outdoor application, cable insulation diameter 1.30 - 2.10 inches for Concentric Neutral/Jacketed Concentric Neutral Cable, Copper 2-Hole Spade #2-1250kcmil, Stranded or Compressed 1000 . - Cable Mounting Bracket - Stainless Steel, 1.80 inch - 2.40 inch (45-61mm).Frequently Asked Questions
What cable insulation diameters does the R2T28 termination cover?
The R2T28 termination covers insulation diameters from 0.84 inches (21.3 mm) to 2.10 inches (53 mm). This accommodates #2 AWG through 1250 kcmil cables.
What is the voltage rating for the R2T28 outdoor termination?
The R2T28 outdoor termination has a voltage rating of 25/28 kV. Its maximum design voltage to ground is 16 kV.
What is the operating ambient temperature range for the R2T28?
The R2T28 termination operates within an ambient temperature range of -22 to +149 °F (-30 to +65 °C).
What is the operating ambient temperature range for the R2T28?
The R2T28 termination operates within an ambient temperature range of -22 to +149 °F (-30 to +65 °C).
What is the voltage rating for the R2T28 outdoor termination?
The R2T28 outdoor termination has a voltage rating of 25/28 kV. Its maximum design voltage to ground is 16 kV.
What cable insulation diameters does the R2T28 termination cover?
The R2T28 termination covers insulation diameters from 0.84 inches (21.3 mm) to 2.10 inches (53 mm). This accommodates #2 AWG through 1250 kcmil cables.
What cable insulation diameters does the R2T28 termination cover?
The R2T28 termination covers insulation diameters from 0.84 inches (21.3 mm) to 2.10 inches (53 mm). This accommodates #2 AWG through 1250 kcmil cables.
What is the operating ambient temperature range for the R2T28?
The R2T28 termination operates within an ambient temperature range of -22 to +149 °F (-30 to +65 °C).
What is the voltage rating for the R2T28 outdoor termination?
The R2T28 outdoor termination has a voltage rating of 25/28 kV. Its maximum design voltage to ground is 16 kV.
Where can I find installation instructions for the R2T28 termination?
Installation instructions are available under specific file numbers: IS-1134 for R2T28J, IS-1135 for R2T28M, and IS-1136 for R2T28L.
How to Install the R2T15/28J Ranger 2 Cable Termination
This guide provides detailed instructions for the installation of 15kV and 28kV Ranger 2 Cable Terminations on concentric and jacketed concentric neutral cables. It covers cable preparation, lug installation, cleaning, and the careful application of the termination body and seals. Ensure all apparatus is de-energized before starting.
Estimated time: 1h 30m
Tools needed:
Cable strippers, Crimping tool, Knife or utility blade, Clean cloths (for solvent application), Aluminum oxide abrasive (grit 120 or finer, if needed), Multimeter (for verifying de-energized state)
Supplies needed:
R2T15/28J Ranger 2 Cable Termination kit (including silicone rubber termination, lubricant, grey silicone rubber tape, sealing mastic, gloves), Connector or terminal lug (compatible with cable and termination), Approved solvent, Vinyl tape or binding wire
- Prepare the Cable for Termination
Verify the cable size is within the kit's specified range. Train the cable into its final position and cut to the required length, ensuring sufficient neutral wire length for grounding. Prepare the cable by stripping the jacket, semi-con, and insulation according to the dimensions provided in Table 1 and accounting for terminal lug depth and conductor growth during crimping. Apply the first band of sealing mastic 1/4 inch (6mm) from the jacket end with 50% stretch, cutting it flush without overlap. Bend the neutral wires back over the mastic and secure them to the cable jacket 4-6 inches (100-150mm) from the cut edge using vinyl tape or binding wire. Apply a second mastic band over the neutral wires and the first mastic, again with 50% stretch and cut flush. Finally, wrap two half-lapped layers of vinyl tape around the mastic seal, maintaining the 1/4 inch (6mm) dimension.
- Install the Terminal Lug or Connector
If using a lug that does not fit through the termination core, clean the cable insulation and slide the termination body onto the cable before installing the lug (do not remove the core yet). Position the chosen connector or terminal lug onto the prepared conductor and crimp it according to the manufacturer's directions, ensuring not to crimp the last 1/4 to 3/8 inch of the connector. After crimping, remove any excess oxide inhibitor and sharp crimp flashings to ensure a smooth surface.
- Clean Cable Insulation and Lug Barrel
Thoroughly wipe the cable insulation with an approved solvent, taking care not to allow the solvent to touch the semi-con insulation shield. If abrasive cleaning is necessary, use only aluminum oxide abrasive (grit 120 or finer) on the insulation, avoiding the semi-con shield. Be careful not to reduce the cable insulation diameter below the kit's allowed specifications.
- Install the Termination Body
Create a track-resistant moisture seal by wrapping a band of grey silicone rubber tape around the base of the terminal lug. If the barrel diameter is equal to or greater than the cable primary insulation, use no more than two layers. If the barrel diameter is smaller, build up the tape to match the insulation diameter. Apply a liberal coating of silicone grease to the edge of the semi-con insulation shield to fill the step at the cut-off. For terminations with a fold-down skirt, pull the loose end of the removable core through the top of the termination until it is flush with the bottom. Slide the termination body onto the cable, aligning its forward edge with the mastic seal. Carefully remove the core by unwinding it counter-clockwise from the loose end, ensuring the termination body (not the core) remains butted against the leading edge of the mastic seal. Do not push or pull the termination assembly during core removal.
- Complete Sealing and Grounding
Apply a thin film of silicone lubricant to the skirt and mastic seal area, but avoid lubricating the skirt tabs. Carefully fold down the skirt over the mastic seal. Complete the lug area moisture seal using the remaining grey silicone rubber tape, overlapping the termination insulator by approximately 1 inch and extending the tape wrapping over a non-crimped region of the lug/connector barrel with a half-lap configuration. Twist the concentric neutral wires together and connect them securely to the system ground. Finally, confirm that the High-K step does not exceed 1.5 inches.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.