ABB - Installation Products R2T15J1-N0240 - Ranger2 Termination for 15KV outdoor application, cable insulation diameter .64 - 1.12 inches for Concentric Neural and Jacketed Concentric Neutral Cable, includes Aluminum 2-Hole Spade connector for #2 to 1250 kcmil. 1/0 Stranded or 2/0 Solid

ABB Installation Products R2T15J1-N0240 Ranger2 Termination for 15KV outdoor application, cable insulation diameter .64 - 1.12…

UPC: 783786019281


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB Ranger2 Termination (SKU: R2T15J1-N0240) is a field-proven outdoor termination kit designed for 15KV applications on concentric neutral and jacketed concentric neutral cables. This termination supports cable insulation diameters ranging from 0.64 to 1.12 inches, accommodating a wide range of conductor sizes from #2 AWG to 1250 kcmil. The included aluminum 2-hole spade connector is compatible with both 1/0 stranded and 2/0 solid conductors, ensuring versatility across common industrial and utility installations. Ranger2 terminations are engineered for outdoor environments where reliability and long-term performance are critical. The design integrates stress control and sealing components to maintain dielectric integrity in harsh weather conditions, including UV exposure, temperature cycling, and moisture ingress. The termination kit is optimized for concentric neutral cables, which are commonly used in medium-voltage distribution systems for grounding and mechanical protection.
  • 15KV outdoor termination for concentric neutral and jacketed concentric neutral cables
  • Supports cable insulation diameters from 0.64 to 1.12 inches
  • Compatible with conductor sizes #2 AWG to 1250 kcmil
  • Includes aluminum 2-hole spade connector for 1/0 stranded or 2/0 solid conductors
  • Field-proven design for reliable performance in harsh outdoor environments

Specifications

Application
Cable Termination, Outdoor Application, 15kV
Cable Type
Concentric Neutral Wire
Color
Gray
Conductor Size
1/0 STR AWG , 1/0 COMPR AWG , 2/0 SOL AWG , 2/0 COMPT AWG
Earthing
Products Includes Their Own Grounding System
Material
Aluminum
Mounting
Product Need to have Cable Holder (not included)
Number Of Terminals
(1) Single Phase
Series
Ranger2
Size
0.64-1.12 inches (insulation diameter)
Special Features
Silicone Rubber Housing. Lightweight, Compact Design. Pull-Down Tabs for Easy Installation. Thick Wall Construction
Standard
IEEE 48
Type
Cable Termination - Outdoor - Ranger2
Voltage Rating
15kV
Voltage Rating
15 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
15kV, Single Piece Terminator (Class 1), Two-Hole Spade Lug. Power Cable Termination, Conductor Size - 1/0 Stranded/Compressed or 2/0 Compact/Solid, Use for Insulation Diameter Range from .640 to 1.070 inches.

PCT10240-3

15kV, Single Piece Terminator (Class 1), Two-Hole Spade Lug. Power Cable Termination, Conductor Size - 1/0 Stranded/Compressed or 2/0 Compact/Solid, Use for Insulation Diameter Range from .640 to 1.070 inches.
Ranger2 Termination for 28KV indoor application, cable insulation diameter .84 - 1.38 inches for Cable Type - Tape Shield, Wire Shield, and Unshielded Cable, Aluminum 2-Hole Spade #2-1250kcmil, Conductor Code 210 - Compact or Solid #2.

R2T28M2-N0210

Ranger2 Termination for 28KV indoor application, cable insulation diameter .84 - 1.38 inches for Cable Type - Tape Shield, Wire Shield, and Unshielded Cable, Aluminum 2-Hole Spade #2-1250kcmil, Conductor Code 210 - Compact or Solid #2.
Ranger2 Termination for 35KV outdoor application, cable insulation diameter .84 - 1.38 inches for Concentric Neural and Jacketed Concentric Neutral Cable, includes Universal Aluminum Barrel For Aluminum or Copper Conductor with copper wire lead, Stranded or Compressed 2/0 /Compact or Solid 3/0

R2T35J2-T0250

Ranger2 Termination for 35KV outdoor application, cable insulation diameter .84 - 1.38 inches for Concentric Neural and Jacketed Concentric Neutral Cable, includes Universal Aluminum Barrel For Aluminum or Copper Conductor with copper wire lead, Stranded or Compressed 2/0 /Compact or Solid 3/0
Outdoor, Ranger2 Termination, 15kV, Concentric Neutral/Jacketed Concentric Neutral Cable Type, Insulation Range - .64-1.12 inch (16-28mm). Connector Type Universal Aluminum Barrel for AL or CU Conductor with Copper Wire Lead #2-4/0. Conductor - 2/0 Stranded/Compressed or 3/0 Compact/Solid. Cable Mounting Bracket Material - Stainless Steel, Size .80-1.25 inch (20-32mm).

R2T15J1-T0250-B1

Outdoor, Ranger2 Termination, 15kV, Concentric Neutral/Jacketed Concentric Neutral Cable Type, Insulation Range - .64-1.12 inch (16-28mm). Connector Type Universal Aluminum Barrel for AL or CU Conductor with Copper Wire Lead #2-4/0. Conductor - 2/0 Stranded/Compressed or 3/0 Compact/Solid. Cable Mounting Bracket Material - Stainless Steel, Size .80-1.25 inch (20-32mm).
Ranger2 Termination. Type - Outdoor, 28kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - 1.30 inch - 2.10 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 380 -Stranded or Compressed 750 Compact or Solid 900. Cable Mounting Bracket - B3 - Stainless Steel - Size 1.45 inch - 1.95 inch.

R2T28J4-N0380-B3

Ranger2 Termination. Type - Outdoor, 28kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - 1.30 inch - 2.10 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 380 -Stranded or Compressed 750 Compact or Solid 900. Cable Mounting Bracket - B3 - Stainless Steel - Size 1.45 inch - 1.95 inch.
Ranger2 Termination for 25/28KV outdoor application, cable insulation diameter .84 - 1.38 for Concentric Neural and Jacketed Concentric Neutral Cable, includes Universal Aluminum Barrel For AL or CU Conductor w/copper wire lead #2 to 4/0. #1 Stranded to 1/0 Solid

R2T28J2-T0230

Ranger2 Termination for 25/28KV outdoor application, cable insulation diameter .84 - 1.38 for Concentric Neural and Jacketed Concentric Neutral Cable, includes Universal Aluminum Barrel For AL or CU Conductor w/copper wire lead #2 to 4/0. #1 Stranded to 1/0 Solid
Ranger2 Termination for 25/28KV outdoor application, cable insulation diameter 1.30 - 2.10 inches for Concentric Neutral/Jacketed Concentric Neutral Cable, Copper 2-Hole Spade #2-1250kcmil, Stranded or Compressed 1000 . - Cable Mounting Bracket - Stainless Steel, 1.80 inch - 2.40 inch (45-61mm).

R2T28J4-N2410-B4

Ranger2 Termination for 25/28KV outdoor application, cable insulation diameter 1.30 - 2.10 inches for Concentric Neutral/Jacketed Concentric Neutral Cable, Copper 2-Hole Spade #2-1250kcmil, Stranded or Compressed 1000 . - Cable Mounting Bracket - Stainless Steel, 1.80 inch - 2.40 inch (45-61mm).
Ranger2 Termination for 25/28KV outdoor application, cable insulation diameter .84 - 1.38 for Concentric Neural and Jacketed Concentric Neutral Cable, includes Universal Aluminum Barrel For AL or CU Conductor w/copper wire lead #2 to 4/0. 1/0 Stranded to 2/0 Solid

R2T28J2-T0240

Ranger2 Termination for 25/28KV outdoor application, cable insulation diameter .84 - 1.38 for Concentric Neural and Jacketed Concentric Neutral Cable, includes Universal Aluminum Barrel For AL or CU Conductor w/copper wire lead #2 to 4/0. 1/0 Stranded to 2/0 Solid

Frequently Asked Questions

What cable sizes does the R2T15 termination support?

The R2T15 termination supports insulation diameters from 0.64 inches (16 mm) to 2.10 inches (53 mm), covering #2 AWG through 1250 kcmil cables. It accommodates XLP and EPR cable types.

What is the voltage rating of the R2T15 termination?

The R2T15 termination has a voltage rating of 15 kV. Its maximum design voltage to ground is 9.5 kV.

What is the operating temperature range for the R2T15?

The R2T15 termination operates within an ambient temperature range of -22 to +149 °F (-30 to +65 °C).

What is the operating temperature range for the R2T15?

The R2T15 termination operates within an ambient temperature range of -22 to +149 °F (-30 to +65 °C).

What is the voltage rating of the R2T15 termination?

The R2T15 termination has a voltage rating of 15 kV. Its maximum design voltage to ground is 9.5 kV.

What cable sizes does the R2T15 termination support?

The R2T15 termination supports insulation diameters from 0.64 inches (16 mm) to 2.10 inches (53 mm), covering #2 AWG through 1250 kcmil cables. It accommodates XLP and EPR cable types.

What is the voltage rating of the R2T15 termination?

The R2T15 termination has a voltage rating of 15 kV. Its maximum design voltage to ground is 9.5 kV.

What cable sizes does the R2T15 termination support?

The R2T15 termination supports insulation diameters from 0.64 inches (16 mm) to 2.10 inches (53 mm), covering #2 AWG through 1250 kcmil cables. It accommodates XLP and EPR cable types.

What is the operating temperature range for the R2T15?

The R2T15 termination operates within an ambient temperature range of -22 to +149 °F (-30 to +65 °C).

What power system frequencies are compatible with R2T15?

The R2T15 termination is compatible with power system frequencies ranging from 48 to 62 Hz.

How to Install 15kV & 28kV Ranger 2 Cable Termination (R2T15/28J)

This guide provides step-by-step instructions for the installation of 15kV and 28kV Ranger 2 Cable Terminations for both indoor and outdoor applications on concentric and jacketed concentric neutral cables.

Estimated time: 1h 30m

Tools needed:

Crimping tool, Wire strippers, Measuring tape or ruler, Cable preparation tools

Supplies needed:

Silicone Rubber Termination kit, Lubricant, Grey Silicone Rubber Tape, Sealing Mastic, Gloves, Elastimold copper or aluminum lugs (or compatible connector), Vinyl tape, Binding wire, Approved solvent, Aluminum oxide abrasive (grit 120 or finer, if needed), Silicone grease

  1. Ensure Safety and De-energize Apparatus

    DANGER: All apparatus must be de-energized during installation or removal of parts. Do not touch or move energized products. This product should be installed only by competent personnel trained in good safety practices involving high voltage electrical equipment. Failure to follow these instructions will result in serious or fatal injury.

  2. Inspect Components and Prepare Workspace

    Check the contents of the package to ensure they are complete and undamaged. Inspect all components for proper fit with the cable and/or mating products. Read the entire installation instructions before starting and have all required tools at hand, maintaining cleanliness throughout the procedure.

  3. Verify Cable Compatibility and Prepare Length

    Confirm that the cable size fits within the kit range as shown in the Termination Selection Chart. Train the cable into its final position and cut it to the length required for installation, allowing sufficient neutral wire length for the grounding connection.

  4. Prepare Cable Dimensions

    Prepare the cable using the dimensions shown in the instructions, allowing for the depth of the terminal lug. Provide additional exposed conductor distance to account for growth during crimping of aluminum lugs or connectors as specified in Table 1 and accompanying figures.

  5. Apply First Mastic Band

    Using a 50% stretch, carefully wrap one band of sealing mastic around the cable jacket 1/4 inch (6mm) from the jacket end. Position the mastic carefully as it also serves as a marker for positioning the terminator. Cut the mastic flush, ensuring no overlap.

  6. Secure Neutral Wires

    Bend the neutral wires back over the first mastic band and press them into the sealing mastic. Secure the neutral wires to the cable jacket 4-6 inches (100-150mm) from the cut edge using vinyl tape or binding wire.

  7. Apply Second Mastic Band and Tape

    Using a 50% stretch, apply a second mastic band over the neutral wires and the previously applied mastic. Cut this band flush, ensuring no overlap. Then, wrap two half-lapped layers of vinyl tape around the mastic seal, carefully maintaining the 1/4 inch (6mm) dimension from the jacket end.

  8. Install Lug or Connector

    If using lugs that do not fit through the termination core, clean the insulation and slide the termination onto the cable before installing the lug (do not remove the core yet). Position the connector or lug and crimp it according to the manufacturer's directions, leaving the last 1/4 to 3/8 inch uncrimped. Remove any excess oxide inhibitor and sharp crimp flashings.

  9. Clean Cable Insulation and Lug Barrel

    Wipe the cable insulation with an approved solvent, ensuring the solvent does not touch the semi-con insulation shield. If an abrasive must be used, apply it only to the insulation (not the semi-con shield) and use only aluminum oxide abrasive, grit 120 or finer. Be careful not to reduce the cable insulation diameter below the kit's allowed range.

  10. Apply Silicone Rubber Tape to Lug Base

    Create a track-resistant moisture seal between the termination insulator and the lug/connector using the gray silicone rubber tape from the kit. Wrap a band of silicone tape around the base of the terminal lug. If the barrel diameter is equal to or greater than the cable primary insulation, do not exceed two layers. If smaller, build up the tape band to equal the insulation diameter.

  11. Apply Silicone Grease to Semi-Con Shield

    Cover the edge of the semi-con insulation shield with a liberal coating of silicone grease. This grease is crucial for filling the step at the semi-con cut-off and does not serve as a lubricant for the termination body.

  12. Position Removable Core

    For lower terminations with a fold-down skirt, pull the loose end of the removable core through the top of the termination until the core is flush with the bottom of the termination body.

  13. Slide Termination Body and Remove Core

    Slide the termination body onto the cable, aligning the terminator with the forward edge of the mastic seal. Carefully begin to remove the core by unwinding it counter-clockwise, starting with the loose end. Ensure the termination body, not the core, is butted up to the leading edge of the mastic seal. Do not push or pull on the termination assembly while removing the core material.

  14. Apply Lubricant and Fold Down Skirt

    Apply a thin film of silicone lubricant to the skirt and the mastic seal area, but do not lubricate the skirt tabs. Carefully fold down the skirt over the mastic seal to complete this section of the termination.

  15. Complete Lug Area Moisture Seal

    With the termination installed, complete the lug area moisture seal using the remaining gray silicone rubber tape. Overlap the termination insulator by approximately 1 inch and extend the tape wrapping over a non-crimped region of the lug/connector barrel with a half-lap configuration.

  16. Connect Neutral Wires to Ground

    Twist the concentric neutral wires together securely and connect them to the system ground according to local and national electrical codes.

  17. Confirm High-K Step Dimension

    Verify that the High-K step, which should overlap the cable semi-con, does not exceed 1.5 inches (38mm) to ensure proper electrical performance and insulation integrity.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.