Authorized ABB Distributor (Installation Products)
ABB - Installation Products R2T28J2-N0300-B3 - Ranger2 Termination for 25/28KV outdoor application, cable insulation diameter .84 - 1.38 inches for Concentric Neural and Jacketed Concentric Neutral Cable, Includes Aluminum 2-Hole Spade connector for #2-1250 kcmil, Stranded or Compressed #2 /Compact or Solid #1, Stainless Steel Mounting Bracket 1.45 inch - 1.95 inch

ABB Installation Products R2T28J2-N0300-B3 Ranger2 Termination for 25/28KV outdoor application, cable insulation diameter .84…

UPC: 783786579570


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB Ranger2 Termination (SKU: R2T28J2-N0300-B3) is engineered for 25/28KV outdoor applications, specifically designed for Concentric Neutral and Jacketed Concentric Neutral cables. This termination system accommodates cable insulation diameters ranging from 0.84 to 1.38 inches, ensuring compatibility with a defined range of cable sizes. Included with the Ranger2 termination is a robust aluminum 2-hole spade connector. This connector is suitable for a broad spectrum of conductor sizes, including #2 through 1250 kcmil for stranded or compressed conductors, and #2 through #1 for compact or solid conductors. This versatility simplifies inventory and installation for various project requirements. The mounting hardware features a stainless steel bracket, providing secure and durable installation. The bracket is designed to fit mounting pole diameters between 1.45 and 1.95 inches, offering flexibility in mounting configurations. The UNSPSC code for this product is 26121648. ABB Installation Products is the manufacturer of this reliable termination solution.
  • Designed for 25/28KV outdoor applications
  • Accommodates cable insulation diameters from 0.84 to 1.38 inches
  • Includes aluminum 2-hole spade connector for #2-1250 kcmil conductors
  • Features stainless steel mounting bracket for 1.45-1.95 inch poles
  • Suitable for Concentric Neutral and Jacketed Concentric Neutral cables

Specifications

Application
Cable Termination, Outdoor Application, 28kV
Cable Type
Concentric Neutral Wire
Color
Gray
Conductor Size
350 to 400 kcmil
Current Rating
2-1250 kcmil
Earthing
Products Includes Their Own Grounding System
Material
Aluminum, Stainless Steel
Mounting
Product Need to have Cable Holder (not included)
Mounting Type
Stainless Steel Bracket (1.45-1.95 inch pole diameter)
Number Of Terminals
(1) Single Phase
Series
Ranger2
Size
0.84-1.38 inches (insulation diameter)
Special Features
Silicone Rubber Housing. Lightweight, Compact Design. Pull-Down Tabs for Easy Installation. Thick Wall Construction
Standard
IEEE 48
Type
Cable Termination - Outdoor - Ranger2
Voltage Rating
25/28 kV
Voltage Rating
28 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
Outdoor Ranger2 Cable Termination. 25/28kV, Cable Type - Tape Shield/Wire Shield/UniShield. Insulation Range - .84 inch - 1.38 inch. Aluminum 2-Hole Spade #2-1250 kcmil, Conductor 350 Stranded/Compressed or 400 Compact/Solid. Cable Mounting Bracket - B2 - Stainless Steel - Size 1.10 inch - 1.50 inch.

R2T28M2-N0300-B2

Outdoor Ranger2 Cable Termination. 25/28kV, Cable Type - Tape Shield/Wire Shield/UniShield. Insulation Range - .84 inch - 1.38 inch. Aluminum 2-Hole Spade #2-1250 kcmil, Conductor 350 Stranded/Compressed or 400 Compact/Solid. Cable Mounting Bracket - B2 - Stainless Steel - Size 1.10 inch - 1.50 inch.
Ranger2 Termination for 25/28KV outdoor application, cable insulation diameter .84 - 1.38 inches for Concentric Neural and Jacketed Concentric Neutral Cable, Includes Aluminum 2-Hole Spade connector for #2-1250 kcmil, Stranded or Compressed 4/0 /Compact or Solid 250, Stainless Steel Mounting Bracket 1.10 inch - 1.50 inch

R2T28J2-N0270-B2

Ranger2 Termination for 25/28KV outdoor application, cable insulation diameter .84 - 1.38 inches for Concentric Neural and Jacketed Concentric Neutral Cable, Includes Aluminum 2-Hole Spade connector for #2-1250 kcmil, Stranded or Compressed 4/0 /Compact or Solid 250, Stainless Steel Mounting Bracket 1.10 inch - 1.50 inch
Ranger2 Termination. Type - Outdoor, 28kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - .84 inch - 1.38 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 280 -Stranded or Compressed 250 Compact or Solid 300.

R2T28J2-N0280

Ranger2 Termination. Type - Outdoor, 28kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - .84 inch - 1.38 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 280 -Stranded or Compressed 250 Compact or Solid 300.
Ranger2 Termination. Type - Outdoor, 15kV, Cable Type - Tape Shield/Wire Shield/ Unshield, Insulation Range - 1.30 inch - 2.10 inch, Connector Type - Copper 2-Hole Spade #2-1250 kcmil, Conductor Code - 330 -Stranded or Compressed 500 Compact or Solid 600. Cable Mounting Bracket - B3 - Stainless Steel - Size 1.45 inch - 1.95 inch.

R2T15M4N2330-B3

Ranger2 Termination. Type - Outdoor, 15kV, Cable Type - Tape Shield/Wire Shield/ Unshield, Insulation Range - 1.30 inch - 2.10 inch, Connector Type - Copper 2-Hole Spade #2-1250 kcmil, Conductor Code - 330 -Stranded or Compressed 500 Compact or Solid 600. Cable Mounting Bracket - B3 - Stainless Steel - Size 1.45 inch - 1.95 inch.
Ranger2 Termination for 15KV outdoor application, cable insulation diameter 1.30 - 2.10 inches for Cable Type - Tape Shield/Wire Shield/Unshield Cable, Copper 2-Hole Spade #2-1250kcmil, Stranded or Compressed 750 /Compact or Solid 900. - Cable Mounting Bracket - Stainless Steel, 1.45 inch - 1.95 inch (37-50mm)

R2T15M4-N2380-B3

Ranger2 Termination for 15KV outdoor application, cable insulation diameter 1.30 - 2.10 inches for Cable Type - Tape Shield/Wire Shield/Unshield Cable, Copper 2-Hole Spade #2-1250kcmil, Stranded or Compressed 750 /Compact or Solid 900. - Cable Mounting Bracket - Stainless Steel, 1.45 inch - 1.95 inch (37-50mm)
Ranger2 Termination for 15KV outdoor application, cable insulation diameter 1.30 - 2.10 inches for Cable Type - Tape Shield/Wire Shield/ UniShield. Includes Aluminum 2-Hole Spade connector for #2-1250 kcmil, Stranded or Compressed 750 /Compact or Solid 900 - Cable Mounting Bracket - Stainless Steel, 1.45 inch - 1.95 inch (37-50mm)

R2T15M4-N0380-B3

Ranger2 Termination for 15KV outdoor application, cable insulation diameter 1.30 - 2.10 inches for Cable Type - Tape Shield/Wire Shield/ UniShield. Includes Aluminum 2-Hole Spade connector for #2-1250 kcmil, Stranded or Compressed 750 /Compact or Solid 900 - Cable Mounting Bracket - Stainless Steel, 1.45 inch - 1.95 inch (37-50mm)
15 kv, Cable Terminator Ranger2, Outdoor, Cable Type - Tape Shield/Wire Shield/UniShield, Insulation Range 4 - 1.30 inch to 2.10 inch (33 mm to 53 mm), Connector Type N2 - Copper 2-Hole Spade #2-1250 kcmil, Conductor Code 350 - Compressed 600 or Compact 700, Cable Mounting Bracket B3 - Material Stainless Steel - Size - 1.45 inch to 1.95 inch (37mm - 50mm)

R2T15M4-N2350-B3

15 kv, Cable Terminator Ranger2, Outdoor, Cable Type - Tape Shield/Wire Shield/UniShield, Insulation Range 4 - 1.30 inch to 2.10 inch (33 mm to 53 mm), Connector Type N2 - Copper 2-Hole Spade #2-1250 kcmil, Conductor Code 350 - Compressed 600 or Compact 700, Cable Mounting Bracket B3 - Material Stainless Steel - Size - 1.45 inch to 1.95 inch (37mm - 50mm)
Ranger2 Termination for 15KV outdoor application, cable insulation diameter 1.30 - 2.10 inches for Cable Type - Tape Shield/Wire Shield/ UniShield. Includes Aluminum 2-Hole Spade connector for #2-1250 kcmil, Stranded or Compressed 750 /Compact or Solid 900

R2T15M4-N0380

Ranger2 Termination for 15KV outdoor application, cable insulation diameter 1.30 - 2.10 inches for Cable Type - Tape Shield/Wire Shield/ UniShield. Includes Aluminum 2-Hole Spade connector for #2-1250 kcmil, Stranded or Compressed 750 /Compact or Solid 900

Frequently Asked Questions

What is the creepage distance for the R2T28 termination?

The creepage distance for the R2T28 termination is 22.8 inches (579 mm).

What is the minimum strike distance for the R2T28?

The minimum strike distance for the R2T28 termination is 14.5 inches (368 mm).

How many sheds does the R2T28 outdoor model have?

The 25/28kV outdoor model of the R2T28 termination has six sheds.

What are the mounting options for the R2T28 termination?

The R2T28 termination can be mounted free hanging or with an optional support bracket.

What is the operating temperature range for the R2T28?

The R2T28 termination operates within an ambient temperature range of -22 to +149 °F (-30 to +65 °C).

What cable sizes does the R2T28 termination support?

The R2T28 termination covers insulation diameters from 0.84 inches to 2.10 inches, accommodating #2 AWG through 1250 kcmil cables.

What power system frequencies does the R2T28 support?

The R2T28 termination supports power system frequencies ranging from 48 to 62 Hz.

What is the maximum altitude for R2T28 installation?

The R2T28 termination can be installed at a maximum altitude of 3300 feet (1005 m).

What is the lightning impulse withstand voltage?

The lightning impulse (BIL Dry 110 Withstand) for the R2T28 termination is 150 kV Crest.

What is the maximum design voltage to ground for the R2T28?

The maximum design voltage to ground for the R2T28 termination is 16 kV.

How to Install the R2T28J2 28kV Ranger 2 Cable Termination

This guide provides step-by-step instructions for preparing the cable, installing the lug, cleaning insulation, and installing the R2T28J2 28kV Ranger 2 Cable Termination for indoor/outdoor applications. This product should only be installed by competent personnel trained in high voltage electrical equipment safety.

Estimated time: 1h 30m

Tools needed:

Wire strippers, Crimping tool, Vinyl tape, Binding wire, Approved solvent, Aluminum oxide abrasive (grit 120 or finer, optional), Gloves

Supplies needed:

Silicone Rubber Termination, Lubricant, Grey Silicone Rubber Tape, Sealing Mastic, Connector (optional), Cable Support Bracket (optional)

  1. De-energize and Prepare the Cable

    DANGER: De-energize all apparatus before beginning installation. Verify the cable size fits within the kit range. Train the cable into position and cut to the required length, allowing sufficient neutral wire length for grounding. Prepare the cable by stripping the jacket and semi-con insulation to the specified dimensions, accounting for terminal lug depth. Apply the first band of sealing mastic 1/4 inch (6mm) from the jacket end, stretching 50%, and cut flush. Bend the neutral wires back over the mastic and secure them to the cable jacket 4-6 inches (100-150mm) from the cut edge using vinyl tape or binding wire. Apply a second mastic band over the neutral wires and the first mastic, stretching 50%, and cut flush. Wrap two half-lapped layers of vinyl tape around the mastic seal, maintaining the 1/4 inch (6mm) dimension.

  2. Install Lug/Connector and Clean Cable

    Position the appropriate connector or lug and crimp it according to directions, ensuring the last 1/4 to 3/8 inch remains uncrimped. Remove any excess oxide inhibitor and sharp crimp flashings following crimping. Wipe the cable insulation with an approved solvent, ensuring it does not touch the semi-con insulation shield. If necessary, use aluminum oxide abrasive (grit 120 or finer) on the insulation only, being careful not to reduce the cable insulation diameter below that allowed by the kit.

  3. Install the Termination Assembly

    Create a track-resistant moisture seal by wrapping a band of grey silicone rubber tape around the base of the terminal lug. Adjust the number of layers based on the barrel diameter relative to the cable primary insulation. Apply a liberal coating of silicone grease to the edge of the semi-con insulation shield to fill the step at the cut-off. For terminations with a fold-down skirt, pull the loose end of the removable core through the top until it is flush with the bottom of the termination. Slide the termination body onto the cable, aligning its forward edge with the mastic seal. Carefully remove the core by unwinding it counter-clockwise from the loose end, ensuring the termination body remains butted against the mastic seal. Do not push or pull the assembly. Apply a thin film of silicone lubricant to the skirt and mastic seal area (do not lubricate skirt tabs). Carefully fold down the skirt over the mastic seal. Complete the lug area moisture seal by wrapping the remaining grey silicone rubber tape, overlapping the termination insulator by approximately 1 inch and extending over a non-crimped region of the lug barrel with a half-lap configuration. Twist the concentric neutral wires together and connect them to the system ground. Confirm that the High-K step does not exceed 1.5 inches.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.