Authorized ABB Distributor (Installation Products)
ABB - Installation Products R2T15M4-N2380-B3 - Ranger2 Termination for 15KV outdoor application, cable insulation diameter 1.30 - 2.10 inches for Cable Type - Tape Shield/Wire Shield/Unshield Cable, Copper 2-Hole Spade #2-1250kcmil, Stranded or Compressed 750 /Compact or Solid 900. - Cable Mounting Bracket - Stainless Steel, 1.45 inch - 1.95 inch (37-50mm)

ABB Installation Products R2T15M4-N2380-B3 Ranger2 Termination for 15KV outdoor application, cable insulation diameter 1.30 - 2.10…

UPC: 075114249430


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

ABB Ranger2 Termination (SKU: R2T15M4-N2380-B3) is a 15kV outdoor cable termination designed for high-reliability applications in utility, industrial, and commercial power distribution systems. This termination supports cable insulation diameters from 1.30 to 2.10 inches (33-53mm), accommodating tape shield, wire shield, and unshielded cables. The copper 2-hole spade connector (#2 to 1250kcmil) handles stranded or compressed conductors up to 750kcmil or compact/solid conductors up to 900kcmil, ensuring broad compatibility with XLP and EPR cable types. Engineered with shrink-fit technology and Elastimold’s pull-down jacket seal, the R2T15M4-N2380-B3 provides a field-proven solution with superior creepage and strike distances for long-term outdoor service. The non-tracking silicone housing delivers exceptional weathering resistance and memory, while the field-removable center core simplifies installation. Four sheds optimize performance in contaminated or high-humidity environments. The stainless steel cable mounting bracket (adjustable 1.45-1.95 inches / 37-50mm) ensures secure installation in restricted spaces or free-hanging applications. This termination meets critical electrical ratings, including a maximum design voltage to ground of 9.5kV, a 110kV BIL dry withstand, and a 45kV 10-second wet withstand. The compact design allows installation where space is limited, while the pull-down tabs streamline jacket sealing for faster deployment. Ideal for outdoor-rated electrical components in high-voltage systems, the Ranger2 termination is a proven choice for reliable 15kV cable terminations in utility substations, industrial facilities, and commercial power distribution networks.
  • 15kV outdoor termination for cable insulation diameters 1.30-2.10 inches (33-53mm)
  • Supports tape shield, wire shield, and unshielded cables (XLP/EPR compatible)
  • Copper 2-hole spade connector (#2 to 1250kcmil) for stranded/compressed conductors
  • Stainless steel mounting bracket (1.45-1.95" / 37-50mm adjustable range)
  • Shrink-fit silicone housing with 4 sheds for superior creepage and weathering resistance

Specifications

Application
Cable Termination, Outdoor Application, 15kV
Cable Type
Copper Tape Shielded Wire
Color
Gray
Conductor Size
750 to 900 kcmil
Connection Type
2-Hole Spade
Earthing
Products Includes Their Own Grounding System
Material
Copper
Mounting
Product Need to have Cable Holder (not included)
Mounting Type
B3 - Stainless Steel
Number Of Terminals
(1) Single Phase
Series
Ranger2
Size
1.30 inch - 2.10 inch
Special Features
Silicone Rubber Housing. Lightweight, Compact Design. Pull-Down Tabs for Easy Installation. Thick Wall Construction
Standard
IEEE 48
Type
Cable Termination - Outdoor - Ranger2
Voltage Rating
15 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
Ranger2 Termination for 15KV outdoor application, cable insulation diameter 1.30 - 2.10 inches for Concentric Neural and Jacketed Concentric Neutral Cable, Copper 2-Hole Spade #2-1250kcmil, Stranded or Compressed 750 /Compact or Solid 900.

R2T15J4-N2380

Ranger2 Termination for 15KV outdoor application, cable insulation diameter 1.30 - 2.10 inches for Concentric Neural and Jacketed Concentric Neutral Cable, Copper 2-Hole Spade #2-1250kcmil, Stranded or Compressed 750 /Compact or Solid 900.
Ranger2 Termination for 15KV outdoor application, cable insulation diameter 1.30 - 2.10 inches for Cable Type - Tape Shield/Wire Shield/ UniShield. Includes Aluminum 2-Hole Spade connector for #2-1250 kcmil, Stranded or Compressed 750 /Compact or Solid 900 - Cable Mounting Bracket - Stainless Steel, 1.45 inch - 1.95 inch (37-50mm)

R2T15M4-N0380-B3

Ranger2 Termination for 15KV outdoor application, cable insulation diameter 1.30 - 2.10 inches for Cable Type - Tape Shield/Wire Shield/ UniShield. Includes Aluminum 2-Hole Spade connector for #2-1250 kcmil, Stranded or Compressed 750 /Compact or Solid 900 - Cable Mounting Bracket - Stainless Steel, 1.45 inch - 1.95 inch (37-50mm)
15 kv, Cable Terminator Ranger2, Outdoor, Cable Type - Tape Shield/Wire Shield/UniShield, Insulation Range 4 - 1.30 inch to 2.10 inch (33 mm to 53 mm), Connector Type N2 - Copper 2-Hole Spade #2-1250 kcmil, Conductor Code 350 - Compressed 600 or Compact 700, Cable Mounting Bracket B3 - Material Stainless Steel - Size - 1.45 inch to 1.95 inch (37mm - 50mm)

R2T15M4-N2350-B3

15 kv, Cable Terminator Ranger2, Outdoor, Cable Type - Tape Shield/Wire Shield/UniShield, Insulation Range 4 - 1.30 inch to 2.10 inch (33 mm to 53 mm), Connector Type N2 - Copper 2-Hole Spade #2-1250 kcmil, Conductor Code 350 - Compressed 600 or Compact 700, Cable Mounting Bracket B3 - Material Stainless Steel - Size - 1.45 inch to 1.95 inch (37mm - 50mm)
Ranger2 Termination for 15KV outdoor application, cable insulation diameter 1.30 - 2.10 inches for Cable Type - Tape Shield/Wire Shield/ UniShield. Includes Aluminum 2-Hole Spade connector for #2-1250 kcmil, Stranded or Compressed 750 /Compact or Solid 900

R2T15M4-N0380

Ranger2 Termination for 15KV outdoor application, cable insulation diameter 1.30 - 2.10 inches for Cable Type - Tape Shield/Wire Shield/ UniShield. Includes Aluminum 2-Hole Spade connector for #2-1250 kcmil, Stranded or Compressed 750 /Compact or Solid 900
Ranger2 Termination. Type - Outdoor, 15kV, Cable Type - Tape Shield/Wire Shield/ Unshield, Insulation Range - .84 inch - 1.38 inch, Connector Type - Copper 2-Hole Spade #2-1250 kcmil, Conductor Code - 330 -Stranded or Compressed 500 Compact or Solid 600.

R2T15M2N2330

Ranger2 Termination. Type - Outdoor, 15kV, Cable Type - Tape Shield/Wire Shield/ Unshield, Insulation Range - .84 inch - 1.38 inch, Connector Type - Copper 2-Hole Spade #2-1250 kcmil, Conductor Code - 330 -Stranded or Compressed 500 Compact or Solid 600.
Ranger2 Termination. Type - Outdoor, 15kV, Cable Type - Tape Shield/Wire Shield/ Unshield, Insulation Range - .84 inch - 1.38 inch, Connector Type - Copper 2-Hole Spade #2-1250 kcmil, Conductor Code - 310 -Stranded or Compressed 400 Compact or Solid 500.

R2T15M2N2310

Ranger2 Termination. Type - Outdoor, 15kV, Cable Type - Tape Shield/Wire Shield/ Unshield, Insulation Range - .84 inch - 1.38 inch, Connector Type - Copper 2-Hole Spade #2-1250 kcmil, Conductor Code - 310 -Stranded or Compressed 400 Compact or Solid 500.
Ranger2 Termination for 15KV outdoor application, cable insulation diameter .84 - 1.38 inches for Tape Shield, Wire Shield, and Unshielded Cable, includes Universal Aluminum Barrel For AL or CU Conductor w/copper wire lead

R2T15M2-T0250

Ranger2 Termination for 15KV outdoor application, cable insulation diameter .84 - 1.38 inches for Tape Shield, Wire Shield, and Unshielded Cable, includes Universal Aluminum Barrel For AL or CU Conductor w/copper wire lead
15 kv, Cable Terminator Ranger2, Outdoor, Cable Type - Tape Shield/Wire Shield/UniShield, Insulation Range 4 - 1.30 inch to 2.10 inch (33 mm to 53 mm), Connector Type N0 - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code 350 - Compressed 650/Compact 750

R2T15M4-N0350

15 kv, Cable Terminator Ranger2, Outdoor, Cable Type - Tape Shield/Wire Shield/UniShield, Insulation Range 4 - 1.30 inch to 2.10 inch (33 mm to 53 mm), Connector Type N0 - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code 350 - Compressed 650/Compact 750

Frequently Asked Questions

Where can I find installation instructions for R2T15?

Installation instructions are IS-1134 for R2T15J, IS-1135 for R2T15M, and IS-1136 for R2T15L.

What is the maximum design voltage to ground for R2T15?

The maximum design voltage to ground for the R2T15 termination is 9.5 kV.

What cable sizes does the R2T15 termination support?

The R2T15 termination supports cable insulation diameters from 0.64 inches to 2.10 inches, covering #2 AWG through 1250 kcmil.

What is the voltage rating of the R2T15 termination?

The R2T15 cable termination has a voltage rating of 15 kV.

What is the operating temperature range for the R2T15?

The R2T15 termination operates within an ambient temperature range of -22 to +149 °F (-30 to +65 °C).

What is the maximum altitude for R2T15 installation?

The R2T15 termination can be installed at a maximum altitude of 3300 feet (1005 meters).

What is the power system frequency range for R2T15?

The R2T15 termination is designed for power system frequencies ranging from 48 to 62 Hz.

What is included in a standard R2T15 kit?

Each kit may contain a Ranger2 Housing, Silicone Lubricant, Plastic Glove, Butyl Auto Tape, and Silicon Tape Roll. Optional items like connectors, crimp charts, and support brackets are ordered separately.

Does the R2T15 termination come with optional connectors?

Yes, optional connectors with copper stem, one-hole, and two-hole spade connectors are available.

What cable types are compatible with the R2T15 units?

The R2T15 units accommodate popular XLP and EPR cable types and shield constructions.

How to Install the R2T15M4 Silicone Rubber Termination for Tape Shielded Cables

This guide provides step-by-step instructions for the safe and proper installation of the 15kV Ranger 2 Shrink-fit Silicone Rubber Termination (R2T15M4) on tape shielded cables, including cable preparation, ground braid installation, lug connection, and termination placement.

Estimated time: 1h 30m

Tools needed:

Crimping tool, Cable preparation tools (strippers, knives), Measuring tape or ruler, Solvent applicator (pads/cloths), Abrasive material (aluminum oxide, grit 120 or finer, if needed)

Supplies needed:

Silicone Rubber Termination (R2T15M4), Silicone Lubricant, Gray Silicone Rubber Electrical Tape, Constant Force Spring, Preformed Ground Braid, Sealing Mastic, Copper Foil Tape, Protective Gloves, Vinyl Electrical Tape, Approved Solvent, Terminal Lug or Connector (compatible with cable)

  1. De-energize and Inspect Cable

    DANGER: Ensure all apparatus is de-energized before beginning installation. Do not touch or move energized products. Verify the cable size fits within the termination's insulation range using the Termination Selection Chart. Inspect all kit components for completeness, damage, and compatibility with the cable and mating parts. Train the cable into its final position and cut it to the required length, allowing for terminal lug depth and any aluminum lug growth allowance.

  2. Prepare Cable Jacket and Shield

    Remove the cable jacket to the length specified by 'Dimension A' in Table 1, plus the required lug depth and growth allowance. Prevent the tape shield from unrolling by securing its edge with a single wrap of the supplied copper foil tape.

  3. Install Mastic Seals and Ground Braid

    Wrap one band of mastic (50% stretch) around the cable jacket 1/4" (6mm) from the jacket end. Position it carefully as a termination marker and cut flush without overlap. Position the preformed ground braid with its short tail over the tape shield and the solder block centered over the mastic strip. Secure the ground braid to the cable jacket using vinyl tape and press the solder block firmly into the mastic. Apply a second mastic band (50% stretch) over the solder block and the first mastic, maintaining the 1/4" (6mm) dimension. Cut flush without overlap. Wrap two half-lapped layers of vinyl tape around the mastic seal, carefully maintaining the 1/4" (6mm) dimension.

  4. Secure Ground Braid with Constant Force Spring

    Wrap the ground braid around the cable tape shield for one complete wrap, trimming any excess to prevent overlap. Secure the ground braid in place with the constant force spring, wrapping the spring in the same direction as the ground braid. Cinch (tighten) the spring after the final winding. Secure the constant force spring with two wraps of vinyl tape. Note: For cloth or paper semi-conductive insulation shields, overwrap the shield with one half-lapped layer of highly stretched semi-conductive rubber tape (e.g., Scotch® No. 13).

  5. Install Terminal Lug or Connector

    Before crimping, check that the termination assembly (with its core intact) will fit over the selected lug. If not, clean the cable insulation and slide the termination onto the cable before installing the lug. Position the connector or lug and crimp it according to the manufacturer's instructions. Avoid crimping the last 3/8" to 1/2" of the connector. Remove any excess oxide inhibitor and all sharp crimp flashings or edges after crimping.

  6. Clean Cable Insulation and Lug Barrel

    Wipe the cable insulation thoroughly with an approved solvent, ensuring the solvent does not touch the semi-conductive insulation shield. If abrasive cleaning is necessary, use only aluminum oxide abrasive (grit 120 or finer) on the insulation, avoiding the semi-conductive shield. Do not reduce the cable insulation diameter.

  7. Prepare Termination for Installation

    Create a track-resistant moisture seal at the base of the terminal lug using the gray silicone rubber electrical tape. Wrap a band of tape around the lug base, using up to two layers if the barrel diameter is equal to or greater than the cable's primary insulation, or building up to the insulation diameter if smaller. Liberally coat the edge of the semi-conductive insulation shield with silicone grease to fill the step at the cut-off. For lower terminations with a fold-down skirt, pull the loose end of the removable core through the top of the termination until the core is flush with the bottom of the termination.

  8. Install and Position Termination Body

    Slide the termination body onto the cable. Align the termination with the forward edge of the mastic seal. Carefully begin to remove the core by unwinding it counter-clockwise, starting with the loose end. Ensure the termination body, not the core, remains butted against the leading edge of the mastic seal. Continue removing the core completely, taking care not to push or pull on the termination assembly during this process.

  9. Complete Moisture Seal and Ground Connection

    Apply a thin film of silicone lubricant to the skirt and mastic seal area, but do not lubricate the skirt tabs. Carefully fold down the skirt over the mastic seal. Complete the lug area moisture seal using the remaining gray silicone rubber electrical tape. Overlap the termination insulator by approximately 1" and extend the tape wrapping over a non-crimped region of the lug/connector barrel with a half-lap configuration. Connect the ground braid securely to the system ground.

  10. Final Verification

    Confirm that the High-K step (the overlap of the termination insulator over the cable semi-con) does not exceed 1.5 inches.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.