ABB - Installation Products R2T15M2-T0250 - Ranger2 Termination for 15KV outdoor application, cable insulation diameter .84 - 1.38 inches for Tape Shield, Wire Shield, and Unshielded Cable, includes Universal Aluminum Barrel For AL or CU Conductor w/copper wire lead

ABB Installation Products R2T15M2-T0250 Ranger2 Termination for 15KV outdoor application, cable insulation diameter .84 - 1.38…

UPC: 783786958603


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB Ranger2 Termination (SKU: R2T15M2-T0250) is a field-proven outdoor termination designed for 15KV cable systems with tape shield, wire shield, or unshielded configurations. It accommodates cable insulation diameters from 0.84 to 1.38 inches, ensuring compatibility with a broad range of medium-voltage cables. The termination features a universal aluminum barrel compatible with both aluminum and copper conductors, eliminating the need for multiple part numbers. A pre-attached copper wire lead simplifies installation and grounding, reducing labor time and potential errors. This termination is engineered for outdoor environments where environmental resistance and long-term reliability are critical. Typical applications include utility substations, industrial power distribution, renewable energy projects, and commercial infrastructure where medium-voltage cable terminations must withstand UV exposure, moisture, and temperature fluctuations. The design follows industry standards for 15KV class terminations, providing a secure seal against moisture ingress while maintaining dielectric integrity. Installation requires standard tools and follows ABB’s proven Ranger2 termination procedures, ensuring consistent performance across installations. The product is part of ABB’s Installation Products portfolio, a trusted brand in electrical infrastructure solutions.
  • 15KV outdoor termination for tape shield, wire shield, and unshielded cables
  • Supports cable insulation diameters from 0.84 to 1.38 inches
  • Universal aluminum barrel compatible with aluminum or copper conductors
  • Pre-attached copper wire lead for simplified grounding and installation
  • Field-proven design for outdoor environments with UV, moisture, and temperature resistance

Specifications

Application
Cable Termination, Outdoor Application, 15kV
Cable Type
Copper Tape Shielded Wire
Color
Gray
Conductor Size
2/0 STR AWG , 2/0 COMPR AWG , 3/0 SOL AWG , 3/0 COMPT AWG
Earthing
Products Includes Their Own Grounding System
Mounting
Product Need to have Cable Holder (not included)
Number Of Terminals
(1) Single Phase
Special Features
Silicone Rubber Housing. Lightweight, Compact Design. Pull-Down Tabs for Easy Installation. Thick Wall Construction
Standard
IEEE 48
Type
Cable Termination - Outdoor - Ranger2
Voltage Rating
15 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
Outdoor, Ranger2 Termination, 15kV, Concentric Neutral/Jacketed Concentric Neutral Cable Type, Insulation Range - .64-1.12 inch (16-28mm). Connector Type Universal Aluminum Barrel for AL or CU Conductor with Copper Wire Lead #2-4/0. Conductor - 2/0 Stranded/Compressed or 3/0 Compact/Solid. Cable Mounting Bracket Material - Stainless Steel, Size .80-1.25 inch (20-32mm).

R2T15J1-T0250-B1

Outdoor, Ranger2 Termination, 15kV, Concentric Neutral/Jacketed Concentric Neutral Cable Type, Insulation Range - .64-1.12 inch (16-28mm). Connector Type Universal Aluminum Barrel for AL or CU Conductor with Copper Wire Lead #2-4/0. Conductor - 2/0 Stranded/Compressed or 3/0 Compact/Solid. Cable Mounting Bracket Material - Stainless Steel, Size .80-1.25 inch (20-32mm).
15 kv, Cable Terminator Ranger2, Outdoor, Cable Type - Tape Shield/Wire Shield/UniShield, Insulation Range 4 - 1.30 inch to 2.10 inch (33 mm to 53 mm), Connector Type N0 - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code 350 - Compressed 650/Compact 750

R2T15M4-N0350

15 kv, Cable Terminator Ranger2, Outdoor, Cable Type - Tape Shield/Wire Shield/UniShield, Insulation Range 4 - 1.30 inch to 2.10 inch (33 mm to 53 mm), Connector Type N0 - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code 350 - Compressed 650/Compact 750
Ranger2 Termination for 15KV outdoor application, cable insulation diameter .64 - 1.12 inches for Concentric Neural and Jacketed Concentric Neutral Cable, includes Universal Aluminum Barrel For AL or CU Conductor w/copper wire lead #2 to 4/0. 4/0 Stranded or 250 kcmil Solid

R2T15J1-T0270

Ranger2 Termination for 15KV outdoor application, cable insulation diameter .64 - 1.12 inches for Concentric Neural and Jacketed Concentric Neutral Cable, includes Universal Aluminum Barrel For AL or CU Conductor w/copper wire lead #2 to 4/0. 4/0 Stranded or 250 kcmil Solid
Ranger2 Termination for 15KV outdoor application, cable insulation diameter .64 - 1.12 inches for Concentric Neural and Jacketed Concentric Neutral Cable, Aluminum 2 Hole Spade #2-1250kcmil, Stranded or Compressed 500 /Compact or Solid 600.

R2T15J1-N0330

Ranger2 Termination for 15KV outdoor application, cable insulation diameter .64 - 1.12 inches for Concentric Neural and Jacketed Concentric Neutral Cable, Aluminum 2 Hole Spade #2-1250kcmil, Stranded or Compressed 500 /Compact or Solid 600.
Ranger2 Termination for 35KV outdoor application, cable insulation diameter .84 - 1.38 inches for Concentric Neural and Jacketed Concentric Neutral Cable, includes Aluminum 2-Hole Spade connector for #2-1250 kcmil, Stranded or Compressed 2/0 /Compact or Solid 3/0

R2T35J2-N0250

Ranger2 Termination for 35KV outdoor application, cable insulation diameter .84 - 1.38 inches for Concentric Neural and Jacketed Concentric Neutral Cable, includes Aluminum 2-Hole Spade connector for #2-1250 kcmil, Stranded or Compressed 2/0 /Compact or Solid 3/0
Ranger2 Termination for 15KV outdoor application, cable insulation diameter .64 - 1.12 inches for Concentric Neural and Jacketed Concentric Neutral Cable, includes Aluminum 2-Hole Spade connector for #2 to 1250 kcmil. 4/0 Stranded or 250 kcmil Solid

R2T15J1-N0270

Ranger2 Termination for 15KV outdoor application, cable insulation diameter .64 - 1.12 inches for Concentric Neural and Jacketed Concentric Neutral Cable, includes Aluminum 2-Hole Spade connector for #2 to 1250 kcmil. 4/0 Stranded or 250 kcmil Solid
Ranger2 Termination. Type - Outdoor, 15kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - .64 inch - 1.12 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 250 -Stranded or Compressed 2/0 Compact or Solid 3/0.

R2T15J1-N0250

Ranger2 Termination. Type - Outdoor, 15kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - .64 inch - 1.12 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 250 -Stranded or Compressed 2/0 Compact or Solid 3/0.
Ranger2 Termination for 35KV outdoor application, cable insulation diameter .84 - 1.38 inches for Concentric Neural and Jacketed Concentric Neutral Cable, includes Universal Aluminum Barrel For Aluminum or Copper Conductor with copper wire lead, Stranded or Compressed 4/0 /Compact or Solid 250, Stainless Steel Mounting Bracket 1.45 inch - 1.95 inch

R2T35J2-T0270-B3

Ranger2 Termination for 35KV outdoor application, cable insulation diameter .84 - 1.38 inches for Concentric Neural and Jacketed Concentric Neutral Cable, includes Universal Aluminum Barrel For Aluminum or Copper Conductor with copper wire lead, Stranded or Compressed 4/0 /Compact or Solid 250, Stainless Steel Mounting Bracket 1.45 inch - 1.95 inch

Frequently Asked Questions

What cable sizes does the R2T15 termination support?

The R2T15 termination supports cable insulation diameters from 0.64 in (16 mm) to 2.10 in (53 mm), covering #2 AWG through 1250 kcmil.

What is the voltage rating of the R2T15 termination?

The R2T15 termination has a voltage rating of 15 kV.

What is the ambient temperature range for R2T15?

The R2T15 termination operates within an ambient temperature range of -22 to +149 °F (-30 to +65 °C).

What is the IEEE classification for the R2T15 outdoor termination?

The R2T15 outdoor termination has an IEEE Classification of Class 1A.

What is the Lightning Impulse Withstand Voltage (BIL) for R2T15?

The Lightning Impulse Withstand Voltage (BIL Dry) for the R2T15 termination is 110 kV Crest.

What is the maximum design voltage to ground for R2T15?

The maximum design voltage to ground for the R2T15 termination is 9.5 kV.

What sizes are available for the R2T15 termination?

The R2T15 termination is available in sizes 1, 2, and 4.

What sizes are available for the optional support bracket?

The optional cable and support bracket is available in four sizes, ranging from 0.80 in to 2.40 in O.D.

What optional connectors are available for R2T15?

Optional connectors with copper stem, one-hole, and two-hole spade connectors are available for the R2T15.

What cable types are compatible with R2T15 terminations?

R2T15 units accommodate popular XLP and EPR cable types and various shield constructions.

How to Install R2T15/28M Shrink Fit Silicone Rubber Termination on Tape Shielded Cables

This guide provides step-by-step instructions for installing the R2T15/28M Shrink Fit Silicone Rubber Termination on tape shielded cables, covering cable preparation, ground braid installation, lug connection, cleaning, and final termination placement.

Estimated time: 1h 30m

Tools needed:

Wire Strippers, Crimping Tool

Supplies needed:

R2T15/28M Termination Kit (includes termination, lubricant, silicone rubber tape, constant force spring, preformed ground braid, sealing mastic, copper foil tape, gloves), Terminal Lug or Connector, Approved Solvent, Vinyl Tape, Aluminum Oxide Abrasive (120 grit or finer, if needed)

  1. Prepare the Cable for Termination

    DANGER: All apparatus must be de-energized during installation. Check that the cable size fits within the termination range. Train the cable into position and cut to the required length. Prepare the cable by removing the jacket and semi-con insulation shield according to the specified dimensions, allowing for terminal lug depth and aluminum lug growth. Secure the tape shield edge with a single wrap of supplied copper foil tape to prevent unrolling.

  2. Install the Ground Braid Assembly

    Wrap one band of sealing mastic around the cable jacket 1/4 inch (6mm) from the jacket end, stretching 50%. Position the preformed ground braid with its short tail over the tape shield and the solder block centered over the mastic. Secure the ground braid to the cable jacket with vinyl tape and press the solder block into the mastic. Apply a second mastic band over the solder block and the first mastic, maintaining the 1/4 inch dimension. Wrap two half-lapped layers of vinyl tape around the mastic seal. Wrap the ground braid around the cable tape shield once, trim excess, and secure it with the constant force spring, wrapping in the same direction. Cinch the spring and secure it with two wraps of vinyl tape. If using cloth or paper semi-con insulation shield, overwrap it with one half-lapped layer of highly stretched semi-conductive rubber tape.

  3. Attach the Terminal Lug or Connector

    First, verify the termination assembly fits over your selected lug. If not, clean the insulation and slide the termination onto the cable before installing the lug (do not remove the core yet). Position the connector or lug and crimp it according to the manufacturer's instructions, ensuring not to crimp the last 3/8 to 1/2 inch of the connector. After crimping, remove any excess oxide inhibitor and all sharp crimp flashings and edges.

  4. Clean Cable Insulation and Lug Barrel

    Wipe the cable insulation with an approved solvent, ensuring the solvent does not touch the semi-con insulation shield. If abrasive cleaning is necessary, use only aluminum oxide abrasive (grit 120 or finer) on the insulation only, avoiding the semi-con shield. Be careful not to reduce the cable insulation diameter below the kit's allowance.

  5. Install and Seal the Termination Body

    Create a track-resistant moisture seal by wrapping gray silicone rubber electrical tape around the base of the terminal lug. If the barrel diameter is smaller than the cable primary insulation, build up the tape band to equal the insulation diameter. Liberally coat the edge of the semi-con insulation shield with silicone grease to fill the step. For lower terminations with a fold-down skirt, pull the loose end of the removable core through the top until it's flush with the bottom. Slide the termination body onto the cable, aligning it with the forward edge of the mastic seal. Carefully remove the core by unwinding counter-clockwise, ensuring the termination body, not the core, is butted against the mastic seal. Do not push or pull the assembly during core removal. Apply a thin film of silicone lubricant to the skirt and mastic seal area (avoid skirt tabs). Fold down the skirt over the mastic seal. Complete the lug area moisture seal with remaining silicone rubber tape, overlapping the termination insulator by approximately 1 inch and extending over a non-crimped region of the lug/connector barrel with a half-lap configuration. Connect the ground braid to the system ground. Finally, confirm that the High-K step does not exceed 1.5 inches.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.