Authorized ABB Distributor (Installation Products)
ABB - Installation Products R2T15M4-N2410 - Outdoor, Ranger2 Termination, 15kV, Cable Type Tape Shield/Wire Shield/Unishield, Insulation Range 1.30 to 2.10 inch (33-53mm). Connector Type Copper 2-Hole Spade #2-1250 kcmil. Conductor Size 1000 Compressed/Stranded.

ABB Installation Products R2T15M4-N2410 Outdoor, Ranger2 Termination, 15kV, Cable Type Tape Shield/Wire Shield/Unishield…

UPC: 075114376297


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

This ABB Ranger2 outdoor termination kit, SKU R2T15M4-N2410, is designed for reliable 15kV applications. It accommodates cable insulation diameters ranging from 1.30 to 2.10 inches (33-53mm), making it suitable for tape shield, wire shield, and Unishield cable types. The integrated connector is a copper 2-hole spade terminal, sized for conductors from #2 AWG up to 1250 kcmil, specifically for 1000 kcmil compressed or stranded conductors. This termination is engineered for outdoor use, providing a secure and insulated connection point for medium-voltage power distribution systems. The Ranger2 series is known for its straightforward installation process, reducing labor time and potential for error in the field. Key specifications include: * **Voltage Rating:** 15kV * **Insulation Range:** 1.30 - 2.10 inches (33-53mm) * **Cable Types:** Tape Shield, Wire Shield, Unishield * **Connector:** Copper 2-Hole Spade * **Conductor Size Compatibility:** #2 AWG - 1250 kcmil (specifically for 1000 kcmil compressed/stranded)
  • 15kV Outdoor Termination Kit
  • Accommodates 1.30-2.10 inch (33-53mm) cable insulation
  • Compatible with Tape Shield, Wire Shield, and Unishield cables
  • Features a Copper 2-Hole Spade connector
  • Designed for 1000 kcmil compressed/stranded conductors (#2 AWG - 1250 kcmil)

Specifications

Application
Cable Termination, Outdoor Application, 15kV
Cable Type
Copper Tape Shielded Wire
Color
Gray
Conductor Size
1000 kcmil
Connection Type
2-Hole Spade
Current Rating
1250 A
Earthing
Products Includes Their Own Grounding System
Material
Copper
Mounting
Product Need to have Cable Holder (not included)
Number Of Terminals
(1) Single Phase
Series
Ranger2 Termination
Size
Conductor Size 1000 Compressed/Stranded
Special Features
Silicone Rubber Housing. Lightweight, Compact Design. Pull-Down Tabs for Easy Installation. Thick Wall Construction
Standard
IEEE 48
Type
Cable Termination - Outdoor - Ranger2
Voltage Rating
15 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
Ranger2 Termination for 15KV outdoor application, cable insulation diameter 1.30 - 2.10 inches for LC Shield Tape Shield/Wire Over Tape Shield. includes Aluminum 2-Hole Spade connector for #2-1250 kcmil, Stranded or Compressed 1000.

R2T15L4-N0410

Ranger2 Termination for 15KV outdoor application, cable insulation diameter 1.30 - 2.10 inches for LC Shield Tape Shield/Wire Over Tape Shield. includes Aluminum 2-Hole Spade connector for #2-1250 kcmil, Stranded or Compressed 1000.
Ranger2 Termination for 25/28KV outdoor application, cable insulation diameter 1.30 - 2.10 inches for Concentric Neutral/Jacketed Concentric Neutral Cable, Copper 2-Hole Spade #2-1250 kcmil, Stranded / Compressed 500 kcmil or Compact / Solid 600 kcmil. No Cable Mounting Bracket

R2T28J4-N2330

Ranger2 Termination for 25/28KV outdoor application, cable insulation diameter 1.30 - 2.10 inches for Concentric Neutral/Jacketed Concentric Neutral Cable, Copper 2-Hole Spade #2-1250 kcmil, Stranded / Compressed 500 kcmil or Compact / Solid 600 kcmil. No Cable Mounting Bracket
15 kv, Ranger2 Terminator, OutDoor, Concentric Neutral/Jacketed Concentric Neutral, .64 inch to 1.12 inch Insulation Range, Connector Type - Aluminum 1 hole Spade #2-500 kcmil, Conductor Code 300 - Standard or Compressed 350, Compact or Solid 400.

R2T15J1-H0300

15 kv, Ranger2 Terminator, OutDoor, Concentric Neutral/Jacketed Concentric Neutral, .64 inch to 1.12 inch Insulation Range, Connector Type - Aluminum 1 hole Spade #2-500 kcmil, Conductor Code 300 - Standard or Compressed 350, Compact or Solid 400.
15kV, Housing Only, Pre-Molded Cable Termination, 2-Hole Spade Lug, For use with Insulation Diameter Range from .830 inch to 1.180 inch.

PCT1-3

15kV, Housing Only, Pre-Molded Cable Termination, 2-Hole Spade Lug, For use with Insulation Diameter Range from .830 inch to 1.180 inch.
25kV, Housing Only, Pre-Molded Cable Termination, 2-Hole Spade Lug, For use with Insulation Diameter Range from .830 inch to 1.180 inch.

PCT2-3

25kV, Housing Only, Pre-Molded Cable Termination, 2-Hole Spade Lug, For use with Insulation Diameter Range from .830 inch to 1.180 inch.
69kV, Transmission Cable Termination (TCT). Base and Top Module, Housing Size 3, Connection Type 2 - 2 Hole NEMA, Connector Type - Copper, Conductor Size 31P, Metallic Screen Kit - Not Required, Armour Kit - Jacketing Tape and Mastic, No Bracket Required.

69TCT232231PNAN

69kV, Transmission Cable Termination (TCT). Base and Top Module, Housing Size 3, Connection Type 2 - 2 Hole NEMA, Connector Type - Copper, Conductor Size 31P, Metallic Screen Kit - Not Required, Armour Kit - Jacketing Tape and Mastic, No Bracket Required.
Ranger2 Termination for 15KV outdoor application, cable insulation diameter .64 - 1.12 inches for Concentric Neural and Jacketed Concentric Neutral Cable, Aluminum 2 Hole Spade #2-1250 kcmil, Stranded or Compressed 700, Compact or Solid 900.

R2T15J1-N0380

Ranger2 Termination for 15KV outdoor application, cable insulation diameter .64 - 1.12 inches for Concentric Neural and Jacketed Concentric Neutral Cable, Aluminum 2 Hole Spade #2-1250 kcmil, Stranded or Compressed 700, Compact or Solid 900.
Indoor Ranger2 Cable Termination. 15kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral. Insulation Range - .64 inch - 1.12 inch. Aluminum 2-Hole Spade #2-1250 kcmil, Conductor 750 Stranded/Compressed or 900 Compact/Solid

R2IT15J1-N0380

Indoor Ranger2 Cable Termination. 15kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral. Insulation Range - .64 inch - 1.12 inch. Aluminum 2-Hole Spade #2-1250 kcmil, Conductor 750 Stranded/Compressed or 900 Compact/Solid

Frequently Asked Questions

What cable sizes does the R2T15 termination cover?

The R2T15 termination covers insulation diameters from 0.64 in to 2.10 in, accommodating #2 AWG through 1250 kcmil cables.

How many sheds does the 15kV outdoor model have?

The 15kV outdoor model of the R2T15 termination has four sheds.

What is the maximum altitude for installation?

The maximum altitude for installing the R2T15 termination is 3300 feet (1005 m).

What power system frequency does the R2T15 support?

The R2T15 termination supports a power system frequency range of 48 to 62 Hz.

What is the operating ambient temperature range?

The R2T15 termination operates within an ambient temperature range of -22 to +149 °F (-30 to +65 °C).

What is the IEEE classification for outdoor applications?

The IEEE classification for outdoor applications of the R2T15 termination is Class 1A.

What is the maximum design voltage to ground?

The maximum design voltage to ground for the R2T15 termination is 9.5 kV.

What is the voltage rating of the R2T15 termination?

The R2T15 termination has a voltage rating of 15 kV.

What sizes are available for the optional support bracket?

The optional cable and support bracket is available in four sizes, ranging from 0.80 in to 2.40 in O.D.

What cable types are compatible with R2T15 terminations?

R2T15 terminations accommodate popular XLP and EPR cable types and various shield constructions.

How to Install the R2T15M4 Silicone Rubber Termination on Tape Shielded Cables

This guide provides detailed instructions for installing the 15kV Ranger 2 Shrink-fit Silicone Rubber Termination (R2T15M4) on tape shielded cables, covering cable preparation, ground braid installation, and final termination setup. Ensure all apparatus are de-energized before starting.

Estimated time: 1h 30m

Tools needed:

Cable preparation tools, Crimping tool, Measuring tape or ruler, Approved solvent, Aluminum oxide abrasive (grit 120 or finer, if needed)

Supplies needed:

R2T15M4 Silicone Rubber Termination kit, Silicone lubricant, Gray silicone rubber electrical tape, Constant force spring, Preformed ground braid, Sealing mastic, Copper foil tape, Gloves, Vinyl tape, Terminal lug or connector

  1. Prepare the Cable

    DANGER: All apparatus must be de-energized during installation. Verify the cable size fits within the insulation range specified in the Termination Selection Chart. Train the cable into position and cut it to the required length. Prepare the cable using the dimensions provided in Table 1, allowing for the depth of the terminal lug and additional exposed conductor distance for aluminum lug growth. Secure the edge of the tape shield with a single wrap of the supplied copper foil tape to prevent unrolling.

  2. Install the Ground Braid

    Carefully wrap one band of sealing mastic around the cable jacket 1/4 inch (6mm) from the jacket end, using 50% stretch, and cut it flush without overlapping. Position the preformed ground braid with its short tail over the tape shield and the solder block centered over the mastic strip. Secure the ground braid to the cable jacket using vinyl tape and press the solder block into the mastic. Apply a second mastic band over the solder block and previous mastic, maintaining the 1/4 inch (6mm) dimension, and cut it flush. Wrap two half-lapped layers of vinyl tape around the mastic seal. Wrap the ground braid around the cable tape shield one complete wrap, trim any excess to prevent overlap, and secure it in place with the constant force spring. Wrap the spring in the same direction as the ground braid, cinch it after the final winding, and secure it with two wraps of vinyl tape. For cloth or paper semi-conductive shields, overwrap with one half-lapped layer of highly stretched semi-conductive rubber tape.

  3. Install the Terminal Lug or Connector

    Check that the termination assembly fits over the selected lug. If it does not, clean the insulation and slide the termination onto the cable before installing the lug (do not remove the core at this time). Position the connector or lug and crimp it according to the manufacturer’s directions, ensuring not to crimp the last 3/8 inch to 1/2 inch of the connector. Remove any excess oxide inhibitor and all sharp crimp flashings and edges after crimping.

  4. Clean Cable Insulation and Lug Barrel

    Wipe the cable insulation with an approved solvent, ensuring the solvent does not touch the semi-conductive insulation shield. If abrasive material is necessary, use only aluminum oxide abrasive (grit 120 or finer) on the insulation, not on the semi-conductive insulation shield. Be careful not to reduce the cable insulation diameter below the kit's allowed specifications.

  5. Install the Termination Body

    Create a track-resistant moisture seal between the termination insulator and the lug/connector by wrapping a band of gray silicone rubber electrical tape around the base of the terminal lug. Adjust the number of tape layers (not exceeding two) if the barrel diameter is equal to or greater than the cable primary insulation, or form the tape band to equal the insulation diameter if the barrel is smaller. Cover the edge of the semi-conductive insulation shield with a liberal coating of silicone grease to fill the step at the semi-con cut-off. For lower terminations with a fold-down skirt, pull the loose end of the removable core through the top until it is flush with the bottom of the termination. Slide the termination body onto the cable, aligning it with the forward edge of the mastic seal. Carefully begin to remove the core by unwinding it counter-clockwise, starting with the loose end. Ensure the termination body, not the core, is butted up to the leading edge of the mastic seal. Continue removing the core without pushing or pulling on the termination assembly.

  6. Complete Moisture Seal and Ground Connection

    Apply a thin film of silicone lubricant to the skirt and mastic seal area, but do not lubricate the skirt tabs. Carefully fold down the skirt over the mastic seal. Complete the lug area moisture seal using the remaining gray silicone rubber electrical tape, overlapping the termination insulator by approximately 1 inch and extending the tape wrapping over a non-crimped region of the lug/connector barrel with a half-lap configuration. Connect the ground braid to the system ground. Finally, confirm that the High-K step does not exceed 1.5 inches.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.