ABB - Installation Products R2T15M1-N0330 - Outdoor Ranger2 Cable Termination. 15kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral. Insulation Range - .64 inch - 1.12 inch. Aluminum 2-Hole Spade #2-1250 kcmil, Conductor 500 Stranded/Compressed or 600 Compact/Solid

ABB Installation Products R2T15M1-N0330 Outdoor Ranger2 Cable Termination. 15kV, Cable Type - Concentric Neutral/Jacketed…

UPC: 075114305419


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB Outdoor Ranger2 Cable Termination (SKU: R2T15M1-N0330) is a field-proven solution for 15kV concentric neutral or jacketed concentric neutral cables. This termination is designed for outdoor installations and accommodates cables with insulation diameters ranging from 0.64 inches (16 mm) to 2.10 inches (53 mm). It supports conductor sizes from #2 AWG through 1250 kcmil, utilizing a #2 aluminum 2-hole spade connector. The Ranger2 series employs shrink-fit technology combined with a pull-down jacket seal for reliable performance across a wide range of applications with minimal model variations. The non-tracking silicone housing offers superior memory and weathering characteristics, ensuring long-term service in demanding field conditions. Its design provides enhanced creepage and strike distances. Installation is simplified with common procedures and cable preparation dimensions, including a field-removable center core and pull-down tabs for easy jacket seal installation. This termination can be installed in restricted spaces and permits free-hanging applications. Optional accessories like insulating silicone sleeves for increased creepage or wildlife protection, copper stem connectors, one-hole and two-hole spade connectors, and cable/support brackets are available. The R2T15M1-N0330 is optimized for utility, industrial, and commercial applications requiring consistent dielectric integrity and mechanical stability, minimizing the risk of partial discharge and insulation breakdown.
  • 15 kV voltage rating for medium-voltage applications.
  • Accommodates 0.64" - 2.10" insulation diameter cables.
  • Supports #2 AWG through 1250 kcmil conductor sizes.
  • Non-tracking silicone housing with superior weathering.
  • Shrink-fit technology with pull-down jacket seal for reliable installation.

Specifications

Application
Cable Termination, Outdoor Application, 15kV
Cable Type
Copper Tape Shielded Wire
Color
Gray
Conductor Size
500 to 600 kcmil
Connection Type
2-Hole Spade
Earthing
Products Includes Their Own Grounding System
Material
Aluminum
Mounting
Product Need to have Cable Holder (not included)
Mounting Type
Outdoor Installation
Number Of Terminals
(1) Single Phase
Series
Ranger2
Size
0.64-1.12 inch insulation, #2-1250 kcmil conductor
Size
0.64 - 1.12 inch
Special Features
Silicone Rubber Housing. Lightweight, Compact Design. Pull-Down Tabs for Easy Installation. Thick Wall Construction
Standard
IEEE 48
Type
Cable Termination - Outdoor - Ranger2
Voltage Rating
15 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
Ranger2 Termination. Type - Indoor, 15kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - .84 inch - 1.38 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 330 -Stranded or Compressed 500, Compact or Solid 600. Cable Mounting Bracket - B3 - Stainless Steel - Size 1.45 inch - 1.95 inch.

R2IT15J2-N0330-B3

Ranger2 Termination. Type - Indoor, 15kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - .84 inch - 1.38 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 330 -Stranded or Compressed 500, Compact or Solid 600. Cable Mounting Bracket - B3 - Stainless Steel - Size 1.45 inch - 1.95 inch.
Ranger2 Termination for 15KV outdoor application, cable insulation diameter 0.64 - 1.12 inches for Cable Type - Tape Shield/Wire Shield/ UniShield. includes Aluminum Barrel For Aluminum Conductor only with copper wire lead #2-4/0, Stranded or Compressed #1 /Compact or Solid 1/0. Stainless Steel Mounting Bracket .80 inch - 1.25 inch (20-32mm)

R2T15M1-T1230-B1

Ranger2 Termination for 15KV outdoor application, cable insulation diameter 0.64 - 1.12 inches for Cable Type - Tape Shield/Wire Shield/ UniShield. includes Aluminum Barrel For Aluminum Conductor only with copper wire lead #2-4/0, Stranded or Compressed #1 /Compact or Solid 1/0. Stainless Steel Mounting Bracket .80 inch - 1.25 inch (20-32mm)
Ranger2 Termination. Type - Outdoor, 15kV, Cable Type - Tape Shield/Wire Shield/ Unshield, Insulation Range - .64 inch - 1.12 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 230 -Stranded or Compressed #1 Compact or Solid 1/0.

R2T15M1-N0230

Ranger2 Termination. Type - Outdoor, 15kV, Cable Type - Tape Shield/Wire Shield/ Unshield, Insulation Range - .64 inch - 1.12 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 230 -Stranded or Compressed #1 Compact or Solid 1/0.
Ranger2 Termination for 15KV outdoor application, cable insulation diameter 0.64 - 1.12 inches for Cable Type - Tape Shield/Wire Shield/ UniShield. includes Aluminum 2-Hole Spade connector for #2-1250 kcmil, Stranded or Compressed 4/0/ Compact or Solid 250.

R2T15M1-N0270

Ranger2 Termination for 15KV outdoor application, cable insulation diameter 0.64 - 1.12 inches for Cable Type - Tape Shield/Wire Shield/ UniShield. includes Aluminum 2-Hole Spade connector for #2-1250 kcmil, Stranded or Compressed 4/0/ Compact or Solid 250.
Ranger2 Termination. Type - Outdoor, 15kV, Cable Type - Tape Shield/Wire Shield/ Unshield, Insulation Range - .64 inch - 1.12 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 210 -Stranded or Compressed N/A Compact or Solid #2.

R2T15M1-N0210

Ranger2 Termination. Type - Outdoor, 15kV, Cable Type - Tape Shield/Wire Shield/ Unshield, Insulation Range - .64 inch - 1.12 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 210 -Stranded or Compressed N/A Compact or Solid #2.
Ranger2 Termination. Type - Outdoor, 15kV, Cable Type - Tape Shield/Wire Shield/ Unshield, Insulation Range - .64 inch - 1.12 inch, Connector Type - Aluminum 1-Hole Spade #2-500 kcmil, Conductor Code - 220 -Stranded or Compressed #2 Compact or Solid #1.

R2T15M1-H0220

Ranger2 Termination. Type - Outdoor, 15kV, Cable Type - Tape Shield/Wire Shield/ Unshield, Insulation Range - .64 inch - 1.12 inch, Connector Type - Aluminum 1-Hole Spade #2-500 kcmil, Conductor Code - 220 -Stranded or Compressed #2 Compact or Solid #1.
Ranger2 Termination for 15KV outdoor application, cable insulation diameter 1.30 - 2.10 inches for LC Shield Tape Shield/Wire Over Tape Shield. includes Aluminum 2-Hole Spade connector for #2-1250 kcmil, Stranded or Compressed 1000.

R2T15L4-N0410

Ranger2 Termination for 15KV outdoor application, cable insulation diameter 1.30 - 2.10 inches for LC Shield Tape Shield/Wire Over Tape Shield. includes Aluminum 2-Hole Spade connector for #2-1250 kcmil, Stranded or Compressed 1000.
Ranger2 Termination for 15KV outdoor application, cable insulation diameter 1.30 - 2.10 inches for Concentric Neural and Jacketed Concentric Neutral Cable, includes Aluminum 2-Hole Spade connector for #2-1250 kcmil, Stranded or Compressed 1000. Stainless Steel Mounting Bracket 1.45 inch - 1.95 inch (37-50mm)

R2T15J4N0410-B3

Ranger2 Termination for 15KV outdoor application, cable insulation diameter 1.30 - 2.10 inches for Concentric Neural and Jacketed Concentric Neutral Cable, includes Aluminum 2-Hole Spade connector for #2-1250 kcmil, Stranded or Compressed 1000. Stainless Steel Mounting Bracket 1.45 inch - 1.95 inch (37-50mm)

Frequently Asked Questions

Where can I find installation instructions for R2T15?

Installation instructions are IS-1134 for R2T15J, IS-1135 for R2T15M, and IS-1136 for R2T15L.

What power system frequencies are supported by R2T15?

The R2T15 termination supports power system frequencies ranging from 48 to 62 Hz.

What is the maximum altitude for R2T15 installation?

The R2T15 termination can be installed at a maximum altitude of 3300 feet (1005 m).

What is the IEEE classification for the R2T15 outdoor termination?

The R2T15 outdoor termination has an IEEE Classification of Outdoor = Class 1A.

What is the operating temperature range for R2T15?

The R2T15 termination operates within an ambient temperature range of -22 to +149 °F (-30 to +65 °C).

What is the maximum design voltage to ground for R2T15?

The maximum design voltage to ground for the R2T15 termination is 9.5 kV.

What is the voltage rating of the R2T15 termination?

The R2T15 termination has a voltage rating of 15 kV.

What cable sizes are compatible with R2T15 terminations?

R2T15 terminations accommodate insulation diameters from 0.64 in (16 mm) to 2.10 in (53 mm), covering #2 AWG through 1250 kcmil cables.

What is the IEEE classification for the R2T15 outdoor termination?

The R2T15 outdoor termination has an IEEE Classification of Outdoor = Class 1A.

What is the maximum altitude for R2T15 installation?

The R2T15 termination can be installed at a maximum altitude of 3300 feet (1005 m).

How to Install the R2T15/28M Shrink Fit Silicone Rubber Termination for Tape Shielded Cables

This guide provides detailed instructions for installing the 15kV & 28kV Ranger 2 Shrink Fit Silicone Rubber Termination on tape shielded cables, covering cable preparation, ground braid installation, lug connection, and termination body placement with critical sealing steps. Ensure all apparatus is de-energized before starting.

Estimated time: 1h 30m

Tools needed:

Wire strippers, Crimping tool, Utility knife, Measuring tape, Approved solvent, Aluminum oxide abrasive (optional)

Supplies needed:

R2T15/28M Silicone Rubber Termination, Silicone Lubricant, Gray Silicone Rubber Electrical Tape, Constant Force Spring, Preformed Ground Braid, Sealing Mastic, Copper Foil Tape, Gloves, Terminal Lug or Connector, Vinyl Tape, Scotcht No. 13 semi-conductive rubber tape (optional)

  1. Prepare the Cable and Install the Ground Braid

    DANGER: All apparatus must be de-energized during installation. Check that the cable size fits within the insulation range specified in the Termination Selection Chart. Train the cable into position and cut it to the required length. Prepare the cable using the provided dimensions, allowing for the depth of the terminal lug and growth allowance. Secure the tape shield's edge with a single wrap of the supplied copper foil tape. Carefully wrap one band of mastic around the cable jacket 1/4 inch (6mm) from the jacket end, using 50% stretch, and cut flush without overlap. Position the preformed ground braid with the short tail over the tape shield and the solder block centered over the mastic strip; secure it to the cable jacket with vinyl tape and press the solder block into the mastic. Apply a second mastic band over the solder block and previous mastic, maintaining the 1/4 inch (6mm) dimension, and cut flush. Wrap two half-lapped layers of vinyl tape around the mastic seal, maintaining the 1/4 inch (6mm) dimension. Wrap the ground braid around the cable tape shield one complete wrap, trim any excess to prevent overlap, and secure it in place with the constant force spring, wrapping the spring in the same direction as the ground braid. Cinch the spring after the final winding and secure it with two wraps of vinyl tape. If using cloth or paper semi-conductive shields, overwrap them with one half-lapped layer of highly stretched semi-conductive rubber tape (e.g., Scotcht No. 13).

  2. Install the Terminal Lug/Connector and Clean Cable Insulation

    Before proceeding, check to ensure the termination assembly fits over the selected lug. If the lug will not fit through the termination core, clean the insulation and slide the termination onto the cable before installing the lug; do not remove the core at this time. Position the connector or lug and crimp it according to the manufacturer’s directions, ensuring not to crimp the last 3/8 inch to 1/2 inch of the connector. After crimping, remove any excess oxide inhibitor and all sharp crimp flashings and edges. Wipe the cable insulation with an approved solvent, taking care not to allow the solvent to touch the semi-conductive insulation shield. If abrasive must be used, apply it only to the insulation (not the semi-conductive shield), use only aluminum oxide abrasive (grit 120 or finer), and be careful not to reduce the cable insulation diameter below the kit's allowed range.

  3. Install the Termination Body and Complete Moisture Seals

    Create a track-resistant moisture seal between the termination insulator and the lug/connector using the gray silicone rubber electrical tape from the kit. Wrap a band of silicone tape around the base of the terminal lug; if the barrel diameter is equal to or greater than the cable primary insulation, do not exceed 2 layers; if smaller, use the tape strip to build up the band equal to the insulation diameter. Liberally coat the edge of the semi-conductive insulation shield with silicone grease to fill the step at the semi-con cut-off. For lower terminations with a fold-down skirt, pull the loose end of the removable core through the top of the termination until the core is flush with the bottom. Slide the termination body onto the cable, aligning its forward edge with the mastic seal. Carefully begin to remove the core by unwinding it counter-clockwise, starting with the loose end. Ensure the termination body, not the core, remains butted up to the leading edge of the mastic seal. Continue to remove the core, avoiding pushing or pulling on the termination assembly. Apply a thin film of silicone lubricant to the skirt and mastic seal area, but do not lubricate the skirt tabs. Carefully fold down the skirt over the mastic seal. Complete the lug area moisture seal using the remaining gray silicone rubber electrical tape, overlapping the termination insulator by approximately 1 inch and extending the tape wrapping over a non-crimped region of the lug/connector barrel with a half-lap configuration. Connect the ground braid to the system ground. Finally, confirm that the High-K step does not exceed 1.5 inches.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.