Authorized ABB Distributor (Installation Products)
ABB - Installation Products R2T15J1-N0260 - Ranger2 Termination for 15KV outdoor application, cable insulation diameter .64 - 1.12 inches for Concentric Neural and Jacketed Concentric Neutral Cable, Aluminum 2 Hole Spade #2-1250kcmil, Stranded or Compressed 3/0 /Compact or Solid 4/0.

ABB Installation Products R2T15J1-N0260 Ranger2 Termination for 15KV outdoor application, cable insulation diameter .64 - 1.12…

UPC: 783786561780


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB Ranger2 15kV Outdoor Termination (SKU: R2T15J1-N0260) is engineered for reliable medium-voltage power distribution in outdoor environments. This termination is designed for Concentric Neutral (CN) and Jacketed Concentric Neutral (JCN) cables, accommodating insulation diameters from 0.64 to 1.12 inches (16 mm to 28.4 mm). It supports a wide range of conductor sizes, from #2 AWG up to 1250 kcmil, including stranded or compressed 3/0 AWG and compact or solid 4/0 AWG. The non-tracking silicone housing offers superior memory and weathering resistance for long-term service. Installation is simplified by the shrink-fit housing, which utilizes common procedures and cable preparation dimensions. A field-removable center core further enhances ease of use. This 15kV outdoor model features four sheds to optimize creepage and strike distances. The Ranger2 series accommodates popular XLP and EPR cable types and shield constructions. Pull-down tabs facilitate easy installation of the built-in jacket seal. Its compact design allows for installation in restricted spaces and permits free-hanging applications. The included aluminum 2-hole spade connector ensures a secure electrical connection. Key ratings include a maximum design voltage to ground of 9.5 kV, a lightning impulse withstand rating (BIL) of 110 kV crest, and a 10-second wet withstand voltage of 45 kV (60Hz). Optional insulating silicone sleeves are available for applications requiring increased creepage or wildlife protection. Optional connectors with copper stems and one-hole spade connectors, as well as cable and support brackets, are also available.
  • Designed for 15kV outdoor applications with Concentric Neutral (CN) and Jacketed Concentric Neutral (JCN) cables.
  • Accommodates cable insulation diameters from 0.64 to 1.12 inches (16 mm to 28.4 mm).
  • Supports conductor sizes from #2 AWG to 1250 kcmil, including 3/0 AWG and 4/0 AWG.
  • Non-tracking silicone housing provides superior memory and weathering characteristics.
  • Features a shrink-fit housing with field-removable center core for simplified installation.

Specifications

Application
Cable Termination, Outdoor Application, 15kV
Cable Type
Concentric Neutral Wire
Color
Gray
Conductor Size
360 kcmil , 4/0 AWG
Connection Type
Concentric Neutral and Jacketed Concentric Neutral Cable
Current Rating
1250 kcmil
Earthing
Products Includes Their Own Grounding System
Material
Aluminum, Silicone
Material
Aluminum
Mounting
Product Need to have Cable Holder (not included)
Mounting Type
Free-hanging, restricted spaces
Number Of Terminals
(1) Single Phase
Series
Ranger2
Size
.64 - 1.12 inches
Special Features
Silicone Rubber Housing. Lightweight, Compact Design. Pull-Down Tabs for Easy Installation. Thick Wall Construction
Standard
IEEE 48
Type
Cable Termination - Outdoor - Ranger2
Voltage Rating
15 kV
Voltage Rating
15kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
Ranger2 Termination. Type - Indoor, 15kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - .64 inch - 1.12 inch, Connector Type - Aluminum 1-Hole Spade #2-1250 kcmil, Conductor Code - 260 -Stranded or Compressed 3/0 Compact or Solid 4/0.

R2IT15J1-N0260

Ranger2 Termination. Type - Indoor, 15kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - .64 inch - 1.12 inch, Connector Type - Aluminum 1-Hole Spade #2-1250 kcmil, Conductor Code - 260 -Stranded or Compressed 3/0 Compact or Solid 4/0.
Ranger2 Termination for 35KV outdoor application, cable insulation diameter 1.30 - 2.10 inches for Concentric Neural and Jacketed Concentric Neutral Cable, includes Aluminum 2-Hole Spade connector for #2-1250 kcmil, Stranded or Compressed 400 /Compact or Solid 500, Stainless Steel Mounting Bracket 1.45 inch - 1.95 inch

R2T35J4-N0310-B3

Ranger2 Termination for 35KV outdoor application, cable insulation diameter 1.30 - 2.10 inches for Concentric Neural and Jacketed Concentric Neutral Cable, includes Aluminum 2-Hole Spade connector for #2-1250 kcmil, Stranded or Compressed 400 /Compact or Solid 500, Stainless Steel Mounting Bracket 1.45 inch - 1.95 inch
Ranger2 Termination for 15KV outdoor application, cable insulation diameter .64 - 1.12 inches for Concentric Neural and Jacketed Concentric Neutral Cable, includes Aluminum Barrel For AL Conductor only w/copper wire lead #2 to 4/0. 4/0 Stranded or 250 kcmil Solid

R2T15J1-T1270

Ranger2 Termination for 15KV outdoor application, cable insulation diameter .64 - 1.12 inches for Concentric Neural and Jacketed Concentric Neutral Cable, includes Aluminum Barrel For AL Conductor only w/copper wire lead #2 to 4/0. 4/0 Stranded or 250 kcmil Solid
Ranger2 Termination for 15KV outdoor application, cable insulation diameter .84 - 1.38 inches for Concentric Neural and Jacketed Concentric Neutral Cable, Aluminum 1-Hole Spade #2-500kcmil. Stranded or Compressed 350 /Compact or Solid 400.

R2T15J2-H0300

Ranger2 Termination for 15KV outdoor application, cable insulation diameter .84 - 1.38 inches for Concentric Neural and Jacketed Concentric Neutral Cable, Aluminum 1-Hole Spade #2-500kcmil. Stranded or Compressed 350 /Compact or Solid 400.
Ranger2 Termination for 35KV outdoor application, cable insulation diameter .84 - 1.38 inches for Concentric Neural and Jacketed Concentric Neutral Cable, includes Universal Aluminum Barrel For Aluminum or Copper Conductor with copper wire lead, Stranded or Compressed 1/0 /Compact or Solid 2/0

R2T35J2-T0240

Ranger2 Termination for 35KV outdoor application, cable insulation diameter .84 - 1.38 inches for Concentric Neural and Jacketed Concentric Neutral Cable, includes Universal Aluminum Barrel For Aluminum or Copper Conductor with copper wire lead, Stranded or Compressed 1/0 /Compact or Solid 2/0
Ranger2 Termination. Type - Outdoor, 35kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - .84 inch - 1.38 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 240 -Stranded or Compressed 1/0 Compact or Solid 2/0.

R2T35J2-N0240

Ranger2 Termination. Type - Outdoor, 35kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - .84 inch - 1.38 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 240 -Stranded or Compressed 1/0 Compact or Solid 2/0.
Ranger2 Termination. Type - Outdoor, 35kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - 1.30 inch - 2.10 inch, Connector Type - Aluminum 1-Hole Spade #2-500 kcmil, Conductor Code - 240 -Stranded or Compressed 1/0 Compact or Solid 2/0.

R2T35J4-H0240

Ranger2 Termination. Type - Outdoor, 35kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - 1.30 inch - 2.10 inch, Connector Type - Aluminum 1-Hole Spade #2-500 kcmil, Conductor Code - 240 -Stranded or Compressed 1/0 Compact or Solid 2/0.
Ranger2 Termination. Type - Outdoor, 35kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - .84 inch - 1.38 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 270 -Stranded or Compressed 4/0 Compact or Solid 250. Cable Mounting Bracket - B3 - Stainless Steel - Size 1.45 inch - 1.95 inch.

R2T35J2-N0270-B3

Ranger2 Termination. Type - Outdoor, 35kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - .84 inch - 1.38 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 270 -Stranded or Compressed 4/0 Compact or Solid 250. Cable Mounting Bracket - B3 - Stainless Steel - Size 1.45 inch - 1.95 inch.

Frequently Asked Questions

How many sheds does the 15kV outdoor model have?

The 15kV outdoor model of the R2T15 termination features four sheds.

What is the IEEE classification for the R2T15 outdoor termination?

The R2T15 outdoor termination has an IEEE Classification of Outdoor = Class 1A.

What is the power system frequency range for R2T15?

The R2T15 termination is designed for a power system frequency range of 48 to 62 Hz.

What is the maximum altitude for R2T15 installation?

The R2T15 termination can be installed at a maximum altitude of 3300 feet (1005 m).

What is the operating temperature range for the R2T15?

The R2T15 termination operates within an ambient temperature range of -22 to +149 °F (-30 to +65 °C).

What is the voltage rating for the R2T15 termination?

The R2T15 termination has a voltage rating of 15 kV. Its maximum design voltage to ground is 9.5 kV.

What cable sizes does the R2T15 termination accommodate?

The R2T15 termination covers insulation diameters from 0.64 inches (16 mm) to 2.10 inches (53 mm), accommodating #2 AWG through 1250 kcmil cables.

What is the power system frequency range for R2T15?

The R2T15 termination is designed for a power system frequency range of 48 to 62 Hz.

What cable sizes does the R2T15 termination accommodate?

The R2T15 termination covers insulation diameters from 0.64 inches (16 mm) to 2.10 inches (53 mm), accommodating #2 AWG through 1250 kcmil cables.

What is the voltage rating for the R2T15 termination?

The R2T15 termination has a voltage rating of 15 kV. Its maximum design voltage to ground is 9.5 kV.

How to Install 15kV & 28kV Ranger 2 Cable Terminations

Complete installation guide for indoor/outdoor 15kV and 28kV Ranger 2 cable terminations on concentric and jacketed concentric neutral cables. All apparatus must be de-energized during installation, and only competent personnel trained in high voltage electrical equipment should perform this procedure.

Estimated time: 1h

Tools needed:

Wire Strippers, Crimping Tool, Measuring Tape, Utility Knife, Gloves, Approved Solvent, Aluminum Oxide Abrasive (120 grit or finer), Vinyl Tape (or Binding Wire)

Supplies needed:

Silicone Rubber Termination Kit (includes termination, lubricant, silicone tape, mastic, gloves), Connector/Lug (if not included in kit), Cable Support Bracket (optional), Silicone Grease

  1. Prepare the Cable for Termination

    De-energize all apparatus before starting. Check the cable size against the Termination Selection Chart to ensure compatibility. Train and cut the cable to the required length for installation, allowing sufficient neutral wire length for the grounding connection. Prepare the cable using the specified dimensions for the cable jacket, semi-con insulation shield, and exposed conductor length. Wrap one band of sealing mastic around the cable jacket 1/4 inch (6mm) from the jacket end, stretching it to 50%. Bend the neutral wires back over the mastic and press them into it, then secure them to the cable jacket 4-6 inches (100-150mm) from the cut edge using vinyl tape or binding wire. Apply a second mastic band over the neutral wires and the first mastic, then wrap two half-lapped layers of vinyl tape around the mastic seal, carefully maintaining the 1/4 inch (6mm) dimension.

  2. Install the Terminal Lug or Connector

    If using a lug or connector that will not fit through the termination core, clean the insulation and slide the termination onto the cable *before* installing the lug. Position the connector/lug and crimp it according to its specific directions, ensuring to leave the last 1/4 to 3/8 inch (6-10mm) of the connector uncrimped. After crimping, carefully remove any excess oxide inhibitor and sharp crimp flashings to prevent damage to the termination.

  3. Clean Cable Insulation and Lug

    Wipe the cable insulation with an approved solvent, taking extreme care not to allow the solvent to touch the semi-con insulation shield. If abrasive cleaning is necessary, use only aluminum oxide abrasive (grit 120 or finer) on the insulation, avoiding the semi-con insulation shield. Be careful not to reduce the cable insulation diameter below that allowed by the kit, as this could compromise the termination's performance.

  4. Install the Silicone Rubber Termination Body

    Create a track-resistant moisture seal by wrapping a band of grey silicone rubber tape (contained in the kit) around the base of the terminal lug. If the barrel diameter is smaller than the cable primary insulation, use the tape strip to build up the tape band equal to the insulation diameter. Apply a liberal coating of silicone grease to the edge of the semi-con insulation shield; this grease fills the step at the semi-con cut-off. For lower terminations with a fold-down skirt, pull the loose end of the removable core through the top of the termination until the core is flush with the bottom. Slide the termination body onto the cable, aligning it with the forward edge of the mastic seal. Carefully remove the core by unwinding it counter-clockwise, starting with the loose end, ensuring the termination body, not the core, is butted up to the leading edge of the mastic seal. Do not push or pull on the termination assembly while removing the core material.

  5. Finalize Termination Seal and Grounding

    Apply a thin film of silicone lubricant to the skirt and mastic seal area, but do not lubricate the skirt tabs. Carefully fold down the skirt over the mastic seal. Complete the lug area moisture seal using the remaining grey silicone rubber tape. Overlap the termination insulator by approximately 1 inch (25mm) and extend the tape wrapping over a non-crimped region of the lug/connector barrel with a half-lap configuration. Twist the concentric neutral wires together and securely connect them to the system ground. Finally, confirm that the High-K step does not exceed 1.5 inches (38mm) to ensure proper electrical performance.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.