ABB - Installation Products R2T15J1-T1270 - Ranger2 Termination for 15KV outdoor application, cable insulation diameter .64 - 1.12 inches for Concentric Neural and Jacketed Concentric Neutral Cable, includes Aluminum Barrel For AL Conductor only w/copper wire lead #2 to 4/0. 4/0 Stranded or 250 kcmil Solid

ABB Installation Products R2T15J1-T1270 Ranger2 Termination for 15KV outdoor application, cable insulation diameter .64 - 1.12…

UPC: 783786785919


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB Ranger2 Termination (SKU: R2T15J1-T1270) is a high-performance outdoor termination designed for 15KV applications, specifically engineered for Concentric Neutral and Jacketed Concentric Neutral cables. This termination supports cable insulation diameters ranging from 0.64 to 1.12 inches, ensuring compatibility with a precise range of cable sizes commonly used in medium-voltage systems. The termination features a durable aluminum barrel construction, optimized exclusively for aluminum conductors to maintain electrical integrity and corrosion resistance in outdoor environments. It includes a copper wire lead with a conductor size range of #2 AWG to 4/0 AWG stranded or 250 kcmil solid aluminum, providing flexibility for various installation requirements. The product is part of ABB’s Installation Products portfolio, a trusted line of solutions for electrical infrastructure, including power distribution networks. Its robust design is tailored for outdoor 15KV systems, where environmental exposure demands reliable performance and long-term durability. The termination’s compatibility with specific cable insulation diameters and conductor sizes ensures proper installation and optimal functionality in medium-voltage applications.
  • 15KV outdoor application rating
  • Suitable for Concentric Neutral and Jacketed Concentric Neutral cables
  • Accommodates cable insulation diameters from 0.64 to 1.12 inches
  • Aluminum barrel for aluminum conductors only
  • Includes copper wire lead for #2 to 4/0 AWG stranded or 250 kcmil solid aluminum conductors

Specifications

Application
Cable Termination, Outdoor Application, 15kV
Cable Type
Concentric Neutral Wire
Color
Gray
Conductor Size
4/0 AWG , 250 kcmil
Connection Type
Concentric Neutral/Jacketed Concentric Neutral
Earthing
Products Includes Their Own Grounding System
Material
Aluminum
Mounting
Product Need to have Cable Holder (not included)
Mounting Type
Cable Mounting
Number Of Terminals
(1) Single Phase
Series
Ranger2
Size
0.64 - 1.12 inches
Special Features
Silicone Rubber Housing. Lightweight, Compact Design. Pull-Down Tabs for Easy Installation. Thick Wall Construction
Standard
IEEE 48
Type
Cable Termination - Outdoor - Ranger2
Voltage Rating
15 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
15kV, Single Piece Terminator (Class 1), includes Universal Aluminum Rod Contact as standard, Power Cable Termination, Conductor Size - 4/0 Stranded/Compressed, Use for Insulation Diameter Range from .640 to 1.070 inches.

PCT10270-4

15kV, Single Piece Terminator (Class 1), includes Universal Aluminum Rod Contact as standard, Power Cable Termination, Conductor Size - 4/0 Stranded/Compressed, Use for Insulation Diameter Range from .640 to 1.070 inches.
Ranger2 Termination for 15KV outdoor application, cable insulation diameter .84 - 1.38 inches for Concentric Neural and Jacketed Concentric Neutral Cable, Aluminum 1-Hole Spade #2-500kcmil. Stranded or Compressed 350 /Compact or Solid 400.

R2T15J2-H0300

Ranger2 Termination for 15KV outdoor application, cable insulation diameter .84 - 1.38 inches for Concentric Neural and Jacketed Concentric Neutral Cable, Aluminum 1-Hole Spade #2-500kcmil. Stranded or Compressed 350 /Compact or Solid 400.
Ranger2 Termination for 35KV outdoor application, cable insulation diameter .84 - 1.38 inches for Concentric Neural and Jacketed Concentric Neutral Cable, includes Universal Aluminum Barrel For Aluminum or Copper Conductor with copper wire lead, Stranded or Compressed 1/0 /Compact or Solid 2/0

R2T35J2-T0240

Ranger2 Termination for 35KV outdoor application, cable insulation diameter .84 - 1.38 inches for Concentric Neural and Jacketed Concentric Neutral Cable, includes Universal Aluminum Barrel For Aluminum or Copper Conductor with copper wire lead, Stranded or Compressed 1/0 /Compact or Solid 2/0
Ranger2 Termination. Type - Outdoor, 35kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - .84 inch - 1.38 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 240 -Stranded or Compressed 1/0 Compact or Solid 2/0.

R2T35J2-N0240

Ranger2 Termination. Type - Outdoor, 35kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - .84 inch - 1.38 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 240 -Stranded or Compressed 1/0 Compact or Solid 2/0.
Ranger2 Termination. Type - Outdoor, 35kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - 1.30 inch - 2.10 inch, Connector Type - Aluminum 1-Hole Spade #2-500 kcmil, Conductor Code - 240 -Stranded or Compressed 1/0 Compact or Solid 2/0.

R2T35J4-H0240

Ranger2 Termination. Type - Outdoor, 35kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - 1.30 inch - 2.10 inch, Connector Type - Aluminum 1-Hole Spade #2-500 kcmil, Conductor Code - 240 -Stranded or Compressed 1/0 Compact or Solid 2/0.
Ranger2 Termination. Type - Outdoor, 35kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - .84 inch - 1.38 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 270 -Stranded or Compressed 4/0 Compact or Solid 250. Cable Mounting Bracket - B3 - Stainless Steel - Size 1.45 inch - 1.95 inch.

R2T35J2-N0270-B3

Ranger2 Termination. Type - Outdoor, 35kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - .84 inch - 1.38 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 270 -Stranded or Compressed 4/0 Compact or Solid 250. Cable Mounting Bracket - B3 - Stainless Steel - Size 1.45 inch - 1.95 inch.
Ranger2 Termination for 15KV outdoor application, cable insulation diameter .84 - 1.38 inches for Concentric Neural and Jacketed Concentric Neutral Cable. Aluminum 2 Hole Spade #2-1250kcmil, Stranded or Compressed #2 /Compact or Solid #1.

R2T15J2-N0220

Ranger2 Termination for 15KV outdoor application, cable insulation diameter .84 - 1.38 inches for Concentric Neural and Jacketed Concentric Neutral Cable. Aluminum 2 Hole Spade #2-1250kcmil, Stranded or Compressed #2 /Compact or Solid #1.
Ranger2 Termination. Type - Outdoor, 35kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - .84 inch - 1.38 inch, Connector Type - Aluminum 1-Hole Spade #2-500 kcmil, Conductor Code - 240 -Stranded or Compressed 1/0 Compact or Solid 2/0.

R2T35J2-H0240

Ranger2 Termination. Type - Outdoor, 35kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - .84 inch - 1.38 inch, Connector Type - Aluminum 1-Hole Spade #2-500 kcmil, Conductor Code - 240 -Stranded or Compressed 1/0 Compact or Solid 2/0.

Frequently Asked Questions

What is the Lightning Impulse Withstand Voltage?

The Lightning Impulse Withstand Voltage (BIL Dry 110 Withstand) for the R2T15 is 110 kV Crest.

What is the power system frequency range?

The R2T15 termination is designed for a power system frequency range of 48 to 62 Hz.

How many sheds does the R2T15 outdoor model have?

The 15kV outdoor model of the R2T15 termination features four sheds.

What is the maximum altitude for R2T15 installation?

The R2T15 termination can be installed at a maximum altitude of 3300 feet (1005 m).

What is the operating temperature range for the R2T15?

The R2T15 termination operates within an ambient temperature range of -22 to +149 °F (-30 to +65 °C).

What is the voltage rating of the R2T15 termination?

The R2T15 termination has a voltage rating of 15 kV. Its maximum design voltage to ground is 9.5 kV.

What cable sizes does the R2T15 termination cover?

The R2T15 termination covers cable sizes from #2 AWG through 1250 kcmil, accommodating insulation diameters from 0.64 inches to 2.10 inches.

What is the IEEE Classification for R2T15 outdoor?

The R2T15 outdoor termination is classified as IEEE Class 1A.

How many sheds does the R2T15 outdoor model have?

The 15kV outdoor model of the R2T15 termination features four sheds.

What is the voltage rating of the R2T15 termination?

The R2T15 termination has a voltage rating of 15 kV. Its maximum design voltage to ground is 9.5 kV.

How to Install 15kV & 28kV Ranger 2 Cable Termination

This guide provides step-by-step instructions for installing the Ranger 2 Cable Termination for 15kV and 28kV concentric and jacketed concentric neutral cables, covering cable preparation, lug installation, and termination assembly. Ensure all apparatus are de-energized before starting.

Estimated time: 1h

Tools needed:

Wire strippers, Crimping tool, Clean cloth, Aluminum oxide abrasive (grit 120 or finer, if needed)

Supplies needed:

Silicone Rubber Termination, Silicone Lubricant, Grey Silicone Rubber Tape, Sealing Mastic, Gloves, Connector or Terminal Lug, Vinyl tape, Binding wire, Approved solvent, Cable Support Bracket (optional)

  1. De-energize Apparatus and Inspect Components

    DANGER: Ensure all apparatus are de-energized before installation or removal of any parts. Inspect all kit contents for completeness and damage. Verify all components fit properly with the cable and mating products.

  2. Prepare Cable for Termination

    Confirm the cable size fits within the kit's range. Train the cable into position and cut to the required length, allowing sufficient neutral wire length for grounding. Prepare the cable using the dimensions shown in the instructions, accounting for terminal lug depth and additional exposed conductor distance for crimping aluminum lugs.

  3. Apply Mastic and Secure Neutral Wires

    Using 50% stretch, wrap one band of sealing mastic around the cable jacket 1/4 inch (6mm) from the jacket end, cutting it flush without overlap. Bend the neutral wires back over and press them into the mastic, securing them to the cable jacket 4-6 inches (100-150mm) from the cut edge using vinyl tape or binding wire. Apply a second mastic band over the neutral wires and the first mastic, cutting it flush. Wrap two half-lapped layers of vinyl tape around the mastic seal, maintaining the 1/4 inch (6mm) dimension.

  4. Install Lug or Connector

    If using non-Elastimold lugs that do not fit through the termination core, clean the insulation and slide the termination onto the cable before installing the lug (do not remove the core at this time). Position the connector or lug and crimp it according to its directions, ensuring not to crimp the last 1/4 to 3/8 inch. Remove any excess oxide inhibitor and sharp crimp flashings.

  5. Clean Cable Insulation and Lug Barrel

    Wipe the cable insulation with an approved solvent, taking care not to let the solvent touch the semi-con insulation shield. If abrasive cleaning is necessary, use only aluminum oxide abrasive (grit 120 or finer) on the insulation only, avoiding the semi-con shield and ensuring not to reduce the cable insulation diameter below the kit's allowance.

  6. Create Lug Moisture Seal and Apply Grease

    Wrap a band of gray silicone rubber tape around the base of the terminal lug to create a track-resistant moisture seal. If the barrel diameter is smaller than the cable primary insulation, use the tape to build up the band equal to the insulation diameter. Apply a liberal coating of silicone grease to the edge of the semi-con insulation shield to fill the step at the cut-off.

  7. Install Termination Body

    For lower terminations with a fold-down skirt, pull the loose end of the removable core through the top of the termination until the core is flush with the bottom. Slide the termination body onto the cable, aligning it with the forward edge of the mastic seal. Carefully remove the core by unwinding it counter-clockwise from the loose end, ensuring the termination body butts against the leading edge of the mastic seal. Do not push or pull the termination assembly while removing the core.

  8. Lubricate, Fold Skirt, and Complete Seals

    Apply a thin film of silicone lubricant to the skirt and mastic seal area, avoiding the skirt tabs. Carefully fold down the skirt over the mastic seal. Using the remaining gray silicone rubber tape, complete the lug area moisture seal by overlapping the termination insulator by approximately 1 inch and extending the tape over a non-crimped region of the lug/connector barrel with a half-lap configuration.

  9. Connect Neutral Wires and Verify High-K Step

    Twist the concentric neutral wires together and connect them to the system ground. Confirm that the High-K step does not exceed 1.5 inches.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.