ABB - Installation Products R2T35J2-T0240 - Ranger2 Termination for 35KV outdoor application, cable insulation diameter .84 - 1.38 inches for Concentric Neural and Jacketed Concentric Neutral Cable, includes Universal Aluminum Barrel For Aluminum or Copper Conductor with copper wire lead, Stranded or Compressed 1/0 /Compact or Solid 2/0

ABB Installation Products R2T35J2-T0240 Ranger2 Termination for 35KV outdoor application, cable insulation diameter .84 - 1.38…

UPC: 783786552412


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB Ranger2 Termination (SKU: R2T35J2-T0240) is a field-proven outdoor termination designed for 35KV applications with cable insulation diameters ranging from 0.84 to 1.38 inches. This termination supports both Concentric Neutral and Jacketed Concentric Neutral cable types, ensuring compatibility with common utility and industrial installations. The universal aluminum barrel accommodates either aluminum or copper conductors, including stranded or compressed 1/0 AWG and compact or solid 2/0 AWG configurations. A copper wire lead is included for grounding and continuity, meeting standard electrical safety requirements. Engineered for outdoor environments, this termination provides reliable dielectric performance and mechanical stability in exposed installations. The design simplifies field assembly with standardized components, reducing installation time while maintaining consistent electrical integrity. Suitable for substations, switchgear, and overhead line terminations where 35KV-rated outdoor terminations are required.
  • Designed for 35KV outdoor applications with cable insulation diameter range: 0.84–1.38 inches
  • Supports Concentric Neutral and Jacketed Concentric Neutral cable types
  • Universal aluminum barrel accommodates both aluminum and copper conductors
  • Compatible with stranded or compressed 1/0 AWG and compact or solid 2/0 AWG conductors
  • Includes copper wire lead for grounding and continuity

Specifications

Application
Cable Termination, Outdoor Application, 35kV
Cable Type
Concentric Neutral Wire
Color
Gray
Conductor Size
1/0 STR AWG , 1/0 COMPR AWG , 2/0 SOL AWG , 2/0 COMPT AWG
Earthing
Products Includes Their Own Grounding System
Mounting
Product Need to have Cable Holder (not included)
Number Of Terminals
(1) Single Phase
Special Features
Silicone Rubber Housing. Lightweight, Compact Design. Pull-Down Tabs for Easy Installation. Thick Wall Construction
Standard
IEEE 48
Type
Cable Termination - Outdoor - Ranger2
Voltage Rating
35 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
Ranger2 Termination. Type - Outdoor, 35kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - .84 inch - 1.38 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 240 -Stranded or Compressed 1/0 Compact or Solid 2/0.

R2T35J2-N0240

Ranger2 Termination. Type - Outdoor, 35kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - .84 inch - 1.38 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 240 -Stranded or Compressed 1/0 Compact or Solid 2/0.
Ranger2 Termination. Type - Outdoor, 35kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - 1.30 inch - 2.10 inch, Connector Type - Aluminum 1-Hole Spade #2-500 kcmil, Conductor Code - 240 -Stranded or Compressed 1/0 Compact or Solid 2/0.

R2T35J4-H0240

Ranger2 Termination. Type - Outdoor, 35kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - 1.30 inch - 2.10 inch, Connector Type - Aluminum 1-Hole Spade #2-500 kcmil, Conductor Code - 240 -Stranded or Compressed 1/0 Compact or Solid 2/0.
Ranger2 Termination. Type - Outdoor, 35kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - .84 inch - 1.38 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 270 -Stranded or Compressed 4/0 Compact or Solid 250. Cable Mounting Bracket - B3 - Stainless Steel - Size 1.45 inch - 1.95 inch.

R2T35J2-N0270-B3

Ranger2 Termination. Type - Outdoor, 35kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - .84 inch - 1.38 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 270 -Stranded or Compressed 4/0 Compact or Solid 250. Cable Mounting Bracket - B3 - Stainless Steel - Size 1.45 inch - 1.95 inch.
Ranger2 Termination for 15KV outdoor application, cable insulation diameter .84 - 1.38 inches for Concentric Neural and Jacketed Concentric Neutral Cable. Aluminum 2 Hole Spade #2-1250kcmil, Stranded or Compressed #2 /Compact or Solid #1.

R2T15J2-N0220

Ranger2 Termination for 15KV outdoor application, cable insulation diameter .84 - 1.38 inches for Concentric Neural and Jacketed Concentric Neutral Cable. Aluminum 2 Hole Spade #2-1250kcmil, Stranded or Compressed #2 /Compact or Solid #1.
Ranger2 Termination. Type - Outdoor, 35kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - .84 inch - 1.38 inch, Connector Type - Aluminum 1-Hole Spade #2-500 kcmil, Conductor Code - 240 -Stranded or Compressed 1/0 Compact or Solid 2/0.

R2T35J2-H0240

Ranger2 Termination. Type - Outdoor, 35kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - .84 inch - 1.38 inch, Connector Type - Aluminum 1-Hole Spade #2-500 kcmil, Conductor Code - 240 -Stranded or Compressed 1/0 Compact or Solid 2/0.
Ranger2 Termination. Type - Outdoor, 35kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - .84 inch - 1.38 inch, Connector Type - Universal Aluminum Barrel for AL or CU Condutor with Copper Wire Lead #2-4/0, Conductor Code - 240 -Stranded or Compressed 1/0 Compact or Solid 2/0. Cable Mounting Bracket - B2 - Stainless Steel - Size 1.10 inch - 1.50 inch.

R2T35J2-T0240-B2

Ranger2 Termination. Type - Outdoor, 35kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - .84 inch - 1.38 inch, Connector Type - Universal Aluminum Barrel for AL or CU Condutor with Copper Wire Lead #2-4/0, Conductor Code - 240 -Stranded or Compressed 1/0 Compact or Solid 2/0. Cable Mounting Bracket - B2 - Stainless Steel - Size 1.10 inch - 1.50 inch.
Ranger2 Termination. Type - Outdoor, 28kV, Cable Type - Tape Shield/Wire Shield/ Unshield, Insulation Range - 1.30 inch - 2.10 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 410 -Stranded or Compressed 1000 Compact or Solid N/A.

R2T28M4-N0410

Ranger2 Termination. Type - Outdoor, 28kV, Cable Type - Tape Shield/Wire Shield/ Unshield, Insulation Range - 1.30 inch - 2.10 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 410 -Stranded or Compressed 1000 Compact or Solid N/A.
Ranger2 Termination for 25/28KV outdoor application, cable insulation diameter 1.30 - 2.10 inches for Tape Shield, Wire Shield, and Unshielded Cable, includes Universal Aluminum Barrel For Aluminum or Copper Conductor with copper wire lead #2-4/0, Stranded or Compressed #2 /Compact or Solid #1, Stainless Steel Mounting Bracket 1.10 inch - 1.50 inch

R2T28M4-T0220-B2

Ranger2 Termination for 25/28KV outdoor application, cable insulation diameter 1.30 - 2.10 inches for Tape Shield, Wire Shield, and Unshielded Cable, includes Universal Aluminum Barrel For Aluminum or Copper Conductor with copper wire lead #2-4/0, Stranded or Compressed #2 /Compact or Solid #1, Stainless Steel Mounting Bracket 1.10 inch - 1.50 inch

Frequently Asked Questions

What is the minimum strike distance for R2T35?

The minimum strike distance for the R2T35 termination is 16.8 in (427 mm).

What is the R2T35 cable termination used for?

The R2T35 is a 35 kV Ranger2 Outdoor Cable Termination designed with shrink-fit technology and a pull-down jacket seal for various applications.

What cable sizes and types are compatible with R2T35?

It covers 0.84 in to 2.10 in insulation diameter cables (#2 AWG through 1250 kcmil) and accommodates XLP and EPR cable types.

What is the voltage rating of the R2T35 termination?

The R2T35 termination has a voltage rating of 35 kV. Its maximum design voltage to ground is 22 kV.

What is the ambient temperature range for R2T35?

The R2T35 termination operates within an ambient temperature range of -22 to +149 °F (-30 to +65 °C).

What is the creepage distance for the R2T35 termination?

The R2T35 termination has a creepage distance of 30.0 in (762 mm). Optional silicone sleeves can provide more creepage.

What is the maximum altitude for R2T35 installation?

The R2T35 termination is rated for an altitude range of 3300 feet max (1005 m).

What power system frequency does R2T35 support?

The R2T35 termination supports a power system frequency range of 48 to 62 Hz.

How many sheds does the R2T35 outdoor model have?

The 35 kV outdoor model of the R2T35 termination features eight sheds.

What are the insulation withstand voltage ratings?

The lightning impulse withstand is 200 kV Crest. The 1 minute dry (60Hz) withstand is 90 kV, and DC withstand 15 min dry is 140 kV.

How to Install the R2T35J2-T0240 35kV Cable Terminator

This guide provides step-by-step instructions for the safe and proper installation of the R2T35J2-T0240 35kV Ranger 2 Cable Terminator on concentric and jacketed concentric neutral cables for indoor/outdoor applications.

Estimated time: 2h

Tools needed:

Wire strippers, Crimping tool, Measuring tape or ruler, Utility knife or cutting tool, Solvent applicator (e.g., clean cloth), Abrasive pad (aluminum oxide, grit 120 or finer, if needed), Safety gloves

Supplies needed:

R2T35J2-T0240 Silicone Rubber Termination Halves (2), Silicone Lubricant, Grey Silicone Rubber Tape, Sealing Mastic, Terminal lug or connector (compatible with cable), Vinyl tape or binding wire, Approved solvent for cable cleaning, Cable Support Bracket (optional)

  1. Perform Pre-Installation Checks and Safety Measures

    Before starting, ensure all apparatus is de-energized. Verify the cable size fits within the kit's range using the Termination Selection Chart. Inspect all kit components for damage and compatibility. Read the entire instructions and have all required tools and supplies ready. Wear appropriate safety gloves.

  2. Prepare the Cable for Termination

    Train the cable into position and cut it to the required length, ensuring sufficient neutral wire length for grounding. Prepare the cable using the specified dimensions: 13-1/2 inches (340mm) for the jacket, 2 inches (50mm) for the semi-con, and 1/4 inch (6mm) for the conductor, allowing for terminal lug depth and additional conductor length for aluminum lugs. Wrap one band of sealing mastic around the cable jacket 1/4 inch (6mm) from the jacket end, stretching 50% and cutting flush. Bend the neutral wires back, press them into the mastic, and secure them to the cable jacket 4-6 inches (100-150mm) from the cut edge using vinyl tape or binding wire. Apply a second mastic band over the neutral wires and the first mastic, stretching 50% and cutting flush. Finally, wrap two half-lapped layers of vinyl tape around the mastic seal, carefully maintaining the 1/4 inch (6mm) dimension.

  3. Install the Terminal Lug or Connector

    If using a lug that will not fit through the termination core, slide the termination onto the cable before installing the lug. Position the connector or lug and crimp it according to the manufacturer's directions, ensuring not to crimp the last 1/4 to 3/8 inch of the connector. After crimping, remove any excess oxide inhibitor and sharp crimp flashings.

  4. Clean Cable Insulation and Lug Barrel

    Wipe the cable insulation with an approved solvent, taking care not to allow the solvent to touch the semi-con insulation shield. If abrasive cleaning is necessary, use only aluminum oxide abrasive (grit 120 or finer) on the insulation only, avoiding the semi-con shield, and ensure the cable insulation diameter is not reduced below the kit's specifications.

  5. Prepare and Install the First Termination Half

    Create a track-resistant moisture seal by wrapping gray silicone rubber tape around the base of the terminal lug. If the barrel diameter is smaller than the cable primary insulation, build up the tape to match the insulation diameter. Apply a liberal coating of silicone grease to the edge of the semi-con insulation shield to fill the step. For the lower termination with a fold-down skirt, pull the loose end of the removable core through the top until it is flush with the bottom. Slide the termination body onto the cable, aligning it with the forward edge of the mastic seal. Carefully remove the core by unwinding it counter-clockwise, ensuring the termination body butts against the mastic seal without pushing or pulling the assembly.

  6. Install the Second Termination Half

    Using the second housing, pull its core down to within one coil of the bottom. Slide this terminator over the cable, overlapping the first terminator by 1-1/2 inches (40mm), and carefully pull its core counter-clockwise. Apply a thin film of silicone lubricant to the skirt and mastic seal area (avoiding skirt tabs), then carefully fold down the skirt over the mastic seal.

  7. Complete Final Sealing and Grounding

    Complete the lug area moisture seal using the remaining gray silicone rubber tape, overlapping the termination insulator by approximately 1 inch and extending over a non-crimped region of the lug/connector barrel with a half-lap configuration. Twist the concentric neutral wires together and connect them to the system ground. Finally, confirm that the High-K step does not exceed 1.5 inches.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.