ABB - Installation Products R2IT15J4-N2300 - 15kV, Ranger2 Cable Termination, Indoor, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - 1.30-2.10 inch (33-53mm), Connector Type - N2 - Copper 2-Hole spade #2-1250 kcmil, Conductor Code 300 - 350 Strandeed/Compressed or 400 Compact/Solid.

ABB Installation Products R2IT15J4-N2300 15kV, Ranger2 Cable Termination, Indoor, Cable Type - Concentric Neutral/Jacketed…

UPC: 075114336123


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB Ranger2 R2IT15J4-N2300 is a 15 kV indoor-rated cable termination designed for medium voltage applications. This termination is engineered for Concentric Neutral and Jacketed Concentric Neutral cable constructions, accommodating insulation diameters from 1.30 to 2.10 inches (33-53mm). It is compatible with popular XLP and EPR cable types. The integrated N2 connector is a two-hole spade type, designed for copper conductors ranging from #2 AWG to 1250 kcmil. It supports conductor sizes of 300-350 kcmil stranded or compressed, and 400 kcmil compact or solid conductors. The Ranger2 series utilizes shrink-fit technology, offering broad application coverage with minimal models. The non-tracking silicone housing provides excellent memory and weathering characteristics. The field-removable center core facilitates easy installation. This termination is suitable for indoor conditions and can be installed in restricted spaces or as a free-hanging solution with optional support brackets. The R2IT15J4-N2300 meets IEEE-48 standards and is classified as Class 2 for indoor applications. It operates within an ambient temperature range of -22 to +149°F (-30 to +65°C) and supports power system frequencies from 48 to 62 Hz. The termination is rated for altitudes up to 3300 feet (1005 m). Key specifications include a voltage rating of 15 kV, maximum design voltage to ground of 9.5 kV, and a lightning impulse withstand voltage (BIL Dry) of 110 kV Crest. The Ranger2 R2IT15J4-N2300 is part of a series known for user-friendly installation and consistent performance. Each kit may include the Ranger2 housing, silicone lubricant, plastic glove, installation instructions, connector (if ordered), crimp chart (if ordered), and support bracket (if ordered).
  • 15 kV voltage rating for medium voltage applications
  • Designed for Concentric Neutral and Jacketed Concentric Neutral cable types
  • Accommodates insulation diameters from 1.30 to 2.10 inches (33-53mm)
  • N2 two-hole spade connector for copper conductors #2 AWG to 1250 kcmil
  • Non-tracking silicone housing with field-removable center core for easy installation

Specifications

Application
Cable Termination, Indoor Application, 15kV
Cable Type
Concentric Neutral Wire
Color
Gray
Conductor Size
350 to 400 kcmil
Connection Type
N2 - Copper 2-Hole spade #2-1250 kcmil
Earthing
Products Includes Their Own Grounding System
Mounting
Product Need to have Cable Holder (not included)
Mounting Type
Indoor
Number Of Terminals
(1) Single Phase
Series
Ranger2
Size
1.30-2.10 inch (33-53mm)
Special Features
Silicone Rubber Housing. Lightweight, Compact Design. Pull-Down Tabs for Easy Installation. Thick Wall Construction
Standard
IEEE 48
Type
Cable Termination - Indoor - Ranger2
Voltage Rating
15 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
Ranger2 Termination. Type - Outdoor, 15kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - .64 inch - 1.12 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 300 -Stranded or Compressed 350 Compact or Solid 400.

R2T15J1-N0300

Ranger2 Termination. Type - Outdoor, 15kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - .64 inch - 1.12 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 300 -Stranded or Compressed 350 Compact or Solid 400.
Ranger2 Termination. Type - Indoor, 15kV, Cable Type - Tape Shield/Wire Shield/ Unshield, Insulation Range - .64 inch - 1.12 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 250 -Stranded/Compressed 2/0 or Compact/Solid 3/0.

R2IT15M1-N0250

Ranger2 Termination. Type - Indoor, 15kV, Cable Type - Tape Shield/Wire Shield/ Unshield, Insulation Range - .64 inch - 1.12 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 250 -Stranded/Compressed 2/0 or Compact/Solid 3/0.
Ranger2 Termination. Type - Indoor, 15kV, Cable Type - Tape Shield/Wire Shield/ Unshield, Insulation Range - .64 inch - 1.12 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 270 -Stranded/Compressed 4/0 or Compact/Solid 250.

R2IT15M1-N0270

Ranger2 Termination. Type - Indoor, 15kV, Cable Type - Tape Shield/Wire Shield/ Unshield, Insulation Range - .64 inch - 1.12 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 270 -Stranded/Compressed 4/0 or Compact/Solid 250.
Ranger2 Termination for 15KV outdoor application, cable insulation diameter 0.84 - 1.38 inches for Cable Type - Tape Shield/Wire Shield/ UniShield. Includes Aluminum 2-Hole Spade connector for #2-1250 kcmil, Standard or Compressed 250 /Compact or Solid 300. Stainless Steel Mounting Bracket 1.10 inch - 1.50 inch

R2T15M2-N0280-B2

Ranger2 Termination for 15KV outdoor application, cable insulation diameter 0.84 - 1.38 inches for Cable Type - Tape Shield/Wire Shield/ UniShield. Includes Aluminum 2-Hole Spade connector for #2-1250 kcmil, Standard or Compressed 250 /Compact or Solid 300. Stainless Steel Mounting Bracket 1.10 inch - 1.50 inch
Ranger2 Termination for 25/28KV outdoor application, cable insulation diameter .84 - 1.38 inches for Concentric Neural and Jacketed Concentric Neutral Cable, Includes Aluminum 2-Hole Spade connector for #2-1250 kcmil, Stranded or Compressed 2/0, Compact or Solid 3/0

R2T28J2-N0250

Ranger2 Termination for 25/28KV outdoor application, cable insulation diameter .84 - 1.38 inches for Concentric Neural and Jacketed Concentric Neutral Cable, Includes Aluminum 2-Hole Spade connector for #2-1250 kcmil, Stranded or Compressed 2/0, Compact or Solid 3/0
15kV, Single Piece Terminator (Class 1), includes Universal Aluminum Rod Contact as standard, Power Cable Termination, Conductor Size - 3/0 Stranded/Compressed or 4/0 Compact/Solid, Use for Insulation Diameter Range from .640 to 1.070 inches. 18 inch contact

PCT1-0260-4-18

15kV, Single Piece Terminator (Class 1), includes Universal Aluminum Rod Contact as standard, Power Cable Termination, Conductor Size - 3/0 Stranded/Compressed or 4/0 Compact/Solid, Use for Insulation Diameter Range from .640 to 1.070 inches. 18 inch contact
25kv, Single Piece Terminator (Class 1), includes Aluminum Rod Contact for Aluminum Conductors only, Power Cable Termination, Conductor Size - 3/0 Stranded/Compressed or 4/0 Compact/Solid, Use for Insulation Diameter Range from .830 to 1.180 inches.

PCT21260-4

25kv, Single Piece Terminator (Class 1), includes Aluminum Rod Contact for Aluminum Conductors only, Power Cable Termination, Conductor Size - 3/0 Stranded/Compressed or 4/0 Compact/Solid, Use for Insulation Diameter Range from .830 to 1.180 inches.
15kV, Single Piece Terminator (Class 1), Two-Hole Spade Lug. Power Cable Termination, Conductor Size - 2/0 Stranded/Compressed or 3/0 Compact/Solid, Use for Insulation Diameter Range from .640 to 1.070 inches.

PCT10250-3

15kV, Single Piece Terminator (Class 1), Two-Hole Spade Lug. Power Cable Termination, Conductor Size - 2/0 Stranded/Compressed or 3/0 Compact/Solid, Use for Insulation Diameter Range from .640 to 1.070 inches.

Frequently Asked Questions

What is the creepage distance of the termination?

The creepage distance for the R2IT15 termination is 8.4 in (213 mm).

What is the voltage rating of the R2IT15 termination?

The R2IT15 cable termination has a voltage rating of 15 kV.

What cable sizes are compatible with R2IT15 terminations?

R2IT15 terminations cover 0.64 in to 2.10 in insulation diameter cables, from #2 AWG through 1250 kcmil.

What is the operating temperature range for this termination?

The ambient temperature range for the R2IT15 termination is -22 to +149 °F (-30 to +65 °C).

What is the maximum altitude for R2IT15 termination installation?

The R2IT15 termination can be installed at a maximum altitude of 3300 feet (1005 m).

What is the power system frequency range?

The power system frequency range for the R2IT15 termination is 48 to 62 Hz.

What is the IEEE classification for this indoor termination?

The R2IT15 indoor termination has an IEEE Classification of Class 2.

What is the maximum design voltage to ground?

The maximum design voltage to ground for the R2IT15 termination is 9.5 kV.

What is the coronal extinction voltage?

The coronal extinction voltage (partial discharge) for the R2IT15 termination is 13 kV (≤ 3pC).

What are the available sizes for the R2IT15 series?

The R2IT15 series is available in sizes 1, 2, and 4.

How to Install the 15kV Ranger 2 Cable Terminator

Complete installation guide for the 15kV Ranger 2 Cable Terminator, designed for indoor applications with concentric and jacketed concentric neutral cables. This indoor kit does not restore a moisture-resistant seal to the cable termination; use indoor/outdoor kits if moisture resistance is required.

Estimated time: 1h 30m

Tools needed:

Wire Strippers, Cutting Tool, Crimping Tool, Gloves

Supplies needed:

Silicone Rubber Termination, Silicone Lubricant, Terminal Lug or Connector, Approved Solvent, Aluminum Oxide Abrasive (optional), Vinyl Tape

  1. Prepare the Cable

    Before starting, ensure all apparatus is de-energized. Check that the cable size fits within the kit's range as shown in the Termination Selection Chart. Train the cable into position and cut it to the required length, allowing sufficient neutral wire length for grounding. Prepare the cable using the provided dimensions, accounting for terminal lug depth and additional exposed conductor distance for aluminum lugs/connectors. Bend neutral wires back and secure them as instructed. DANGER: All apparatus must be de-energized during installation or removal of part(s). Failure to do so will result in serious or fatal injury.

  2. Install the Terminal Lug or Connector

    If using lugs that will not fit through the termination core, clean the insulation and slide the termination onto the cable before installing the lug (do not remove the core yet). Position the connector/lug and crimp it according to the manufacturer’s directions, leaving the last 1/4” to 3/8” uncrimped. After crimping, remove any excess oxide inhibitor and sharp crimp flashings.

  3. Clean Cable Insulation and Lug Barrel

    Wipe the cable insulation with an approved solvent, ensuring the solvent does not touch the semi-con insulation shield. If abrasive cleaning is necessary, use only aluminum oxide abrasive (grit 120 or finer) on the insulation only, not on the semi-con insulation shield. Be careful not to reduce the cable insulation diameter below the kit's allowed range.

  4. Install the Termination Body

    Cover the edge of the semi-con insulation shield with a liberal coating of silicone grease to fill the step at the semi-con cut-off. Slide the terminator body onto the cable, aligning its skirt with the edge of the cable jacket. Carefully begin to remove the core by rotating the lead counter-clockwise while pulling. Recheck the terminator position and continue removing the core. Do not push or pull on the terminator assembly during core removal. Finally, twist the concentric neutral wires together and connect them to the system ground.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.