ABB Installation Products R2IT15M1-N0270 Ranger2 Termination. Type - Indoor, 15kV, Cable Type - Tape Shield/Wire Shield/…
UPC: 075114347976
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- Non-tracking silicone housing for superior memory and weathering.
- Shrink-fit technology with common installation procedures.
- Field-removable center core for easy installation.
- Accommodates cable insulation diameters from 0.64" to 1.12".
- Aluminum 2-hole spade connector for #2 AWG to 1250 kcmil conductors.
Specifications
Application | Cable Termination, Indoor Application, 15kV |
Cable Type | Copper Tape Shielded Wire |
Color | Gray |
Conductor Size | 4/0 AWG , 250 kcmil |
Earthing | Products Includes Their Own Grounding System |
Mounting | Product Need to have Cable Holder (not included) |
Number Of Terminals | (1) Single Phase |
Special Features | Silicone Rubber Housing. Lightweight, Compact Design. Pull-Down Tabs for Easy Installation. Thick Wall Construction |
Standard | IEEE 48 |
Type | Cable Termination - Indoor - Ranger2 |
Voltage Rating | 15 kV |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 1.0000 L |
Package Weight (Metric) | 0.4540 kg |

PCT10270-3
15kV, Single Piece Terminator (Class 1), Two Hole Spade Lug. Power Cable Termination, Conductor Size - 4/0 Stranded/Compressed, Use for Insulation Diameter Range from .640 to 1.070 inches.
R2T15M2-N0280-B2
Ranger2 Termination for 15KV outdoor application, cable insulation diameter 0.84 - 1.38 inches for Cable Type - Tape Shield/Wire Shield/ UniShield. Includes Aluminum 2-Hole Spade connector for #2-1250 kcmil, Standard or Compressed 250 /Compact or Solid 300. Stainless Steel Mounting Bracket 1.10 inch - 1.50 inch
R2T28J2-N0250
Ranger2 Termination for 25/28KV outdoor application, cable insulation diameter .84 - 1.38 inches for Concentric Neural and Jacketed Concentric Neutral Cable, Includes Aluminum 2-Hole Spade connector for #2-1250 kcmil, Stranded or Compressed 2/0, Compact or Solid 3/0
PCT1-0260-4-18
15kV, Single Piece Terminator (Class 1), includes Universal Aluminum Rod Contact as standard, Power Cable Termination, Conductor Size - 3/0 Stranded/Compressed or 4/0 Compact/Solid, Use for Insulation Diameter Range from .640 to 1.070 inches. 18 inch contact
PCT21260-4
25kv, Single Piece Terminator (Class 1), includes Aluminum Rod Contact for Aluminum Conductors only, Power Cable Termination, Conductor Size - 3/0 Stranded/Compressed or 4/0 Compact/Solid, Use for Insulation Diameter Range from .830 to 1.180 inches.
PCT10250-3
15kV, Single Piece Terminator (Class 1), Two-Hole Spade Lug. Power Cable Termination, Conductor Size - 2/0 Stranded/Compressed or 3/0 Compact/Solid, Use for Insulation Diameter Range from .640 to 1.070 inches.
PCT20220-4
25kv, Single Piece Terminator (Class 1), includes Universal Aluminum Rod Contact for Aluminum or Copper Conductors, Power Cable Termination, Conductor Size - #2 Stranded/Compressed or #1 Compact/Solid, Use for Insulation Diameter Range from .830 to 1.180 inches.
PCT20270-3
25kv, Single Piece Terminator (Class 1), Two Hole Spade Lug, Power Cable Termination, Conductor Size - 4/0 Stranded/Compressed, Use for Insulation Diameter Range from .830 to 1.180 inches.Frequently Asked Questions
What is the voltage rating for the Ranger2 termination?
The Ranger2 termination is rated for 15kV applications.
What is the insulation range for this ABB termination?
This ABB Ranger2 termination accommodates cable insulation diameters ranging from 0.64 inches to 1.12 inches.
What types of cables can be used with this termination?
The Ranger2 termination is suitable for tape shield, wire shield, and unshielded cable types.
What size conductors does the aluminum spade connector support?
The aluminum 2-hole spade connector supports conductors from #2 AWG to 1250 kcmil.
What conductor codes are compatible with this Ranger2 unit?
Conductor code 270 indicates compatibility with stranded/compressed 4/0 AWG or compact/solid 250 kcmil conductors.
How to Install the R2IT15M1-N0270 15kV Ranger 2 Shrink Fit Silicone Rubber Termination
This guide provides step-by-step instructions for the indoor installation of the 15kV Ranger 2 Shrink Fit Silicone Rubber Termination (R2IT15M series) on tape shielded cables, covering cable preparation, ground braid installation, lug connection, and termination placement. Ensure all apparatus is de-energized before starting.
Estimated time: 1h 30m
Tools needed:
Cable preparation tools (knife, wire strippers), Crimping tool, Solvent pads, Aluminum oxide abrasive (120 grit or finer, optional), Scissors or cutters
Supplies needed:
R2IT15M1-N0270 Termination Kit, Vinyl tape, Silicone lubricant, Terminal lug or connector, Gloves
- Prepare the Cable and Ensure Safety
WARNING: Ensure all apparatus is de-energized before beginning installation. Verify the cable size fits the termination kit. Train the cable into position and cut to the required length. Prepare the cable by removing the jacket, semi-conductive layer, and insulation according to the specified dimensions, allowing for terminal lug depth and growth allowance. For tape shielded cables, secure the tape shield edge with the supplied copper foil tape.
- Install the Ground Braid
Wrap one band of vinyl tape 1/4 inch (6mm) from the cable jacket end. Position the preformed ground braid with its short tail over the tape shield and the solder block centered over the vinyl tape marker. Secure the ground braid to the cable jacket with vinyl tape. Apply a second vinyl tape band directly over the original marker and solder block. Wrap the ground braid around the cable tape shield once, trim any excess, and secure it in place with the constant force spring. Secure the spring with two wraps of vinyl tape.
- Install and Clean the Terminal Lug
Check that the termination assembly fits over the selected lug; if not, slide the termination onto the cable before installing the lug. Position the connector or lug and crimp it according to the manufacturer's directions, ensuring not to crimp the last 3/8 to 1/2 inch. After crimping, remove any excess oxide inhibitor and all sharp crimp flashings or edges. Wipe the cable insulation with solvent-saturated pads, taking care not to touch the semi-conductive insulation shield. If using abrasive, apply it only to the insulation.
- Install the Silicone Rubber Termination
Apply a liberal coating of silicone grease to the edge of the semi-conductive insulation shield to fill the step at the semi-con cut-off. Slide the termination body onto the cable, aligning its forward edge with the vinyl tape marker. Carefully begin to remove the core by pulling counter-clockwise. Recheck the termination position and continue removing the core. Do not push or pull on the termination assembly during core removal. Finally, connect the ground braid to the system ground.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.