Authorized ABB Distributor (Installation Products)
ABB - Installation Products K656YSR-M0360 - 600 Amp, 15/25kV, Deadbreak, Straight Receptacle with Test Point, Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Compression Lug. Conductor Size Compressed Stranded 650 kcmil or Compacted Solid 750/800 kcmil.

ABB Installation Products K656YSR-M0360 600 Amp, 15/25kV, Deadbreak, Straight Receptacle with Test Point, Cable Insulation…

UPC: 075114401722


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB K656YSR-M0360 is a 600 Amp, 15/25kV deadbreak straight receptacle designed for high-voltage electrical connections in medium-voltage systems. This fully shielded, submersible molded rubber housing receptacle provides a secure and reliable interface for 15/25kV high-voltage apparatus bushings, including switchgear and transformers equipped with 600 Amp bushings. The product features a non-corrosive capacitive test point for safe diagnostic procedures without compromising connection integrity. Key specifications include a continuous current rating of 600 Amps and a momentary rating of 25kA symmetrical for 10 cycles. For the 15kV voltage class, it supports a maximum phase-to-ground operating voltage of 8.3kV and phase-to-phase voltage of 14.4kV, with a basic impulse insulation level (BIL) of 95kV. For the 25kV class, it supports 16.2kV phase-to-ground and 28kV phase-to-phase, with a BIL of 140kV. The receptacle meets ANSI/IEEE Standard 386 and provides 34kV AC one-minute withstand and 53kV DC 15-minute withstand for the 15kV class, and 45kV AC one-minute withstand and 84kV DC 15-minute withstand for the 25kV class. The K656YSR-M0360 accommodates cable insulation diameters from 1.370 inches to 1.630 inches and supports compressed stranded conductors up to 650 kcmil or compacted solid conductors from 750 kcmil to 800 kcmil. The integrated aluminum compression lug ensures a high-capacity, corrosion-resistant termination. The 100% peroxide-cured EPDM construction delivers long-term durability and environmental resistance. The receptacle can be connected or disconnected in a de-energized state, and optional accessories enable visible external separation, bypass, isolation, dead-ending, grounding, and testing. When used with metallic tape shield or drain wire cable, an ECS ground kit/cable seal is recommended.
  • 600 Amp continuous current rating with 25kA symmetrical momentary rating
  • Supports 15kV and 25kV voltage classes per ANSI/IEEE Standard 386
  • Cable insulation diameter range: 1.370" to 1.630"
  • Accommodates compressed stranded 650 kcmil or compacted solid 750/800 kcmil conductors
  • Non-corrosive capacitive test point for safe diagnostics without de-energizing
  • Fully shielded, submersible molded rubber housing with 100% peroxide-cured EPDM construction
  • Can be connected/disconnected in de-energized state; optional accessories available

Specifications

Amperage Rating
600 A
Application
15/25kV, 600 Amps
Color
Black
Conductor Range
STR/COMPR 650 kcmil , SOL/COMPT 750/800 kcmil
Connection
Compression
Connection Type
Compression Lug
Current Rating
600 A
Environmental Conditions
All Weather Conditions
Insulation
True
Material
Aluminum
Material
Housing - EPDM-Rubber
Series
K656YSR
Size
1.370-1.630 inch (cable insulation diameter)
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Deadbreak Straight Receptacle with Test Point
Voltage Rating
15 to 25 kV
Voltage Rating
15/25 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Capacitive Test Ports, Small Housing, Cable Insulation Diameter 0.635 inch - 0.905 inch / 16-23mm, Bi-Metal Conductor size 2 AWG Stranded/Compressed, 1 AWG Solid/Compact. no Sealing Kit

168FLR1-B5220

Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Capacitive Test Ports, Small Housing, Cable Insulation Diameter 0.635 inch - 0.905 inch / 16-23mm, Bi-Metal Conductor size 2 AWG Stranded/Compressed, 1 AWG Solid/Compact. no Sealing Kit
15/25kV, 600 Amp, DeadBreak, Elbow with Test Point (includes Insulated Plug, Cap, Stud, Lug and Cable Adapter). Cable Insulation 1.090-1.310 inches, Aluminum Compression Lug, Conductor Size 750 Stranded/Compressed

K656LR-K0380

15/25kV, 600 Amp, DeadBreak, Elbow with Test Point (includes Insulated Plug, Cap, Stud, Lug and Cable Adapter). Cable Insulation 1.090-1.310 inches, Aluminum Compression Lug, Conductor Size 750 Stranded/Compressed
600 Amp, 15/25kV, 600 Series Deadbreak Direct Test Elbow with Test Point, (with Insulated Plug, Cap, Stud, Lug and Cable Adapter), Aluminum Compression Lug. Cable Insulation Diameter 1.515 inch to 1.780 inch. Conductor Size kcmil Compressed Stranded 1000. Cold Shrinkable Jacket Seal.

K656DLR-N0410-S

600 Amp, 15/25kV, 600 Series Deadbreak Direct Test Elbow with Test Point, (with Insulated Plug, Cap, Stud, Lug and Cable Adapter), Aluminum Compression Lug. Cable Insulation Diameter 1.515 inch to 1.780 inch. Conductor Size kcmil Compressed Stranded 1000. Cold Shrinkable Jacket Seal.
15kV, 600 Amps, Combo T Elbow with Bus Stud, Cable Adapter and Lug. Cable Insulation Diameter 1.515-1.780 inches, Tin Plated Aluminum ShearBolt Lug, Conductor Size 750 to 1250 kcmil Stranded/Compressed and Solid/Compact. Cold Shrinkable Jacket Seal.

656CETP-NAC04-DRG-S

15kV, 600 Amps, Combo T Elbow with Bus Stud, Cable Adapter and Lug. Cable Insulation Diameter 1.515-1.780 inches, Tin Plated Aluminum ShearBolt Lug, Conductor Size 750 to 1250 kcmil Stranded/Compressed and Solid/Compact. Cold Shrinkable Jacket Seal.
25kV, 600 Amp, Deadbreak, Elbow with Test Point, (includes Insulated Plug, Cap, Stud, Lug and Cable Adapter), No Sealing Kit, Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 1000. Any Customer Specific Modifications CS871 - CSA Die Compatibility.

K656LR-N0410-CS871

25kV, 600 Amp, Deadbreak, Elbow with Test Point, (includes Insulated Plug, Cap, Stud, Lug and Cable Adapter), No Sealing Kit, Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 1000. Any Customer Specific Modifications CS871 - CSA Die Compatibility.
15/25kV 600 Amp Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter), Aluminum Compression Lug. Cable Insulation Diameter 1.515 inch to 1.780 inch. Conductor Size Compressed/Stranded 500, No Sealing Kit

K656LR-N0330

15/25kV 600 Amp Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter), Aluminum Compression Lug. Cable Insulation Diameter 1.515 inch to 1.780 inch. Conductor Size Compressed/Stranded 500, No Sealing Kit
15/25kV 600 Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter), Aluminum Compression Lug. Cable Insulation Diameter 1.515 inch to 1.780 inch. Conductor Size AWG or kcmil, Compressed Stranded 900 /Compacted Solid 1000 /mmSquared Compact 500. Any Customer Specific Modifications - CS471 - CSA Die Compatibility.

K656LRN0400-CS871

15/25kV 600 Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter), Aluminum Compression Lug. Cable Insulation Diameter 1.515 inch to 1.780 inch. Conductor Size AWG or kcmil, Compressed Stranded 900 /Compacted Solid 1000 /mmSquared Compact 500. Any Customer Specific Modifications - CS471 - CSA Die Compatibility.
15-25kV 600 Series Deadbreak Separable Straight Joint Package (2-Way) with Test Point. Aluminum Compression Lug. Cable Insulation Diameter 1.370 inch to 1.630 inch. Conductor Size Compressed Stranded 700/750 kcmil or Compacted Solid 900 kcmil. Cold Shrinkable Jacket Seal. Also includes Spiking Aid Appendage and Insulated Cap.

K656ISL-M0380-S

15-25kV 600 Series Deadbreak Separable Straight Joint Package (2-Way) with Test Point. Aluminum Compression Lug. Cable Insulation Diameter 1.370 inch to 1.630 inch. Conductor Size Compressed Stranded 700/750 kcmil or Compacted Solid 900 kcmil. Cold Shrinkable Jacket Seal. Also includes Spiking Aid Appendage and Insulated Cap.

Frequently Asked Questions

What items are included in a K656YSR kit?

Each kit contains a straight receptacle housing, installation instructions, cable adapter, aluminum compression lug, adapter retaining ring, crimp chart, and bolts & washers.

Does the K656SR have a test point?

Yes, it includes a non-corrosive capacitive test point.

What is recommended for metallic tape shield cables?

When used on metallic tape shield or drain wire cable, an ECS ground kit/cable seal is recommended.

Is the K656SR suitable for submersible applications?

Yes, the K656SR features a fully shielded, fully submersible molded rubber housing.

What standard does the K656SR meet?

The K656SR meets ANSI/IEEE Standard 386, Latest Revision.

What is the maximum operating voltage for the 25kV class?

For the 25kV voltage class, the maximum phase-to-ground operating voltage is 16.2kV, and phase-to-phase is 28kV.

What is the maximum operating voltage for the 15kV class?

For the 15kV voltage class, the maximum phase-to-ground operating voltage is 8.3kV, and phase-to-phase is 14.4kV.

What is the continuous current rating for K656SR?

The continuous current rating for both 15kV and 25kV voltage classes is 600 Amps.

What cable insulation diameters does K656SR support?

It supports cable insulation diameters from 0.640 inches to 1.935 inches.

What conductor sizes are compatible with K656SR?

The K656SR product range supports #2 AWG to 1250 kcmil for aluminum and copper conductors.

How to Locate K656YSR-M0360 Installation Instructions

This guide explains where to find the official installation instructions for the K656YSR-M0360 product, as they are not contained within this notice document.

Estimated time: 5m

  1. Understand Product Context

    Recognize that the K656YSR-M0360 product is specifically intended for use with Elastimold separable joint housings.

  2. Locate Primary Installation Guide

    Identify and retrieve the installation instructions that are physically packaged with the Elastimold separable joint housings.

  3. Adhere to Primary Instructions

    Strictly follow all installation procedures and guidelines detailed within the instructions provided with the Elastimold separable joint housings when installing the K656YSR-M0360.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.