ABB - Installation Products K656LR-N0330 - 15/25kV 600 Amp Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter), Aluminum Compression Lug. Cable Insulation Diameter 1.515 inch to 1.780 inch. Conductor Size Compressed/Stranded 500, No Sealing Kit

ABB Installation Products K656LR-N0330 15/25kV 600 Amp Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud…

UPC: 075114269346


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB K656LR-N0330 is a 15/25kV, 600 Amp Series Deadbreak Elbow designed for reliable power distribution connections in medium-voltage applications. This elbow includes a built-in test point for safe and convenient electrical testing without disrupting service. The unit comes equipped with an insulated plug, cap, stud, lug, and cable adapter to provide a complete connection system. The integrated aluminum compression lug ensures a secure and durable electrical connection, optimized for high-performance performance in demanding environments. Engineered for compatibility with cable insulation diameters ranging from 1.515 inches to 1.780 inches, this deadbreak elbow is specifically designed to accommodate 500 kcmil compressed or stranded conductors. The compression lug is factory-installed and pre-engineered for consistent performance, eliminating the need for additional field assembly steps. The elbow’s deadbreak design allows for safe connection and disconnection under load, enhancing operational flexibility and safety in medium-voltage systems. Manufactured by ABB Installation Products, a leader in electrical infrastructure components, the K656LR-N0330 adheres to stringent quality and safety standards. Its construction prioritizes electrical integrity, corrosion resistance, and ease of installation within specified parameters. The product is suitable for applications requiring robust and safe termination of medium-voltage cables, including utility, industrial, and commercial installations. Note: This model does not include a sealing kit, which must be ordered separately if required for environmental protection. For precise application suitability, always verify conductor size and insulation diameter against product specifications to ensure proper fit and performance. The UNSPSC code for this product is 39121421.
  • 15/25kV Voltage Rating
  • 600 Amp Current Rating
  • Includes Test Point, Insulated Plug, Cap, Stud, and Cable Adapter
  • Aluminum Compression Lug for secure connection
  • Accommodates Cable Insulation Diameter: 1.515" - 1.780"
  • Designed for 500 kcmil Compressed/Stranded Conductors

Specifications

Amperage Rating
600 A
Application
15/25kV, 600 Amp Deadbreak Elbow Connection
Color
Black
Conductor Range
500 kcmil , 600 kcmil
Environmental Conditions
Fully Submersible
Insulation
True
Length
13 in
Length
330.2 mm
Material
Housing - EPDM-Rubber
Special Features
Fully Shielded, Fully Submersible Molded Rubber Housing. 100 percent Peroxide-Cured Construction includes Insulation and Conductive EPDM Materials. Can be Easily Connected or Disconnected using Standard Hand Tools and Equipment in a De-Energized State. Non-Corrosive, Capacitive Test Point
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Deadbreak Elbow Connector with Test Point
Voltage Rating
25 kV
Width
10.36 in
Width
263.144 mm
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
15/25kV, 600 Amps, 2-Way Vault-Stretcher. Cable Insulation Diameter range 1.37-1.63 inch (34.8-41.4mm). Connector Sizing 330 - 500 kcmil Stranded / Compressed, 600 kcmil Solid or Compact. Kit Includes (1) Vault Stretcher Housing, (2) Compression Lugs, (2) Cable Adapters (2) Insulated Plugs with Caps (1) Stud. Lubricant, Installation Instruction Sheet. Cold Shrinkable Seal with Copper Braid and Constant Force Spring also Included. Vault Stretcher Housing 21.75 inches x 8,69 inches.

K655VSL2-L0330-SG3

15/25kV, 600 Amps, 2-Way Vault-Stretcher. Cable Insulation Diameter range 1.37-1.63 inch (34.8-41.4mm). Connector Sizing 330 - 500 kcmil Stranded / Compressed, 600 kcmil Solid or Compact. Kit Includes (1) Vault Stretcher Housing, (2) Compression Lugs, (2) Cable Adapters (2) Insulated Plugs with Caps (1) Stud. Lubricant, Installation Instruction Sheet. Cold Shrinkable Seal with Copper Braid and Constant Force Spring also Included. Vault Stretcher Housing 21.75 inches x 8,69 inches.
Polarizing Cover / Hermaphroditic Cover, Black, Nylon, 8 Position, AMPMODU IV/V

103350-4

Polarizing Cover / Hermaphroditic Cover, Black, Nylon, 8 Position, AMPMODU IV/V
15/25kV 600 Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter), Aluminum Compression Lug. Cable Insulation Diameter 1.515 inch to 1.780 inch. Conductor Size AWG or kcmil, Compressed Stranded 900 /Compacted Solid 1000 /mmSquared Compact 500. Any Customer Specific Modifications - CS471 - CSA Die Compatibility.

K656LRN0400-CS871

15/25kV 600 Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter), Aluminum Compression Lug. Cable Insulation Diameter 1.515 inch to 1.780 inch. Conductor Size AWG or kcmil, Compressed Stranded 900 /Compacted Solid 1000 /mmSquared Compact 500. Any Customer Specific Modifications - CS471 - CSA Die Compatibility.
6 Point Junction, with three 200 Amp Bushing Well Interfaces and three 600 Amp Bushing Interfaces, 15kV, No Parking Stand. Standard 4 inch spacing.

J6-222666-15-N

6 Point Junction, with three 200 Amp Bushing Well Interfaces and three 600 Amp Bushing Interfaces, 15kV, No Parking Stand. Standard 4 inch spacing.
5 Point Junction, with two 200 Amp Bushing Well Interfaces and three 600 Amp Bushing Interfaces, alternating Interfaces starting with the 600 Amp. 15kV, No Parking Stand. Standard 4 inch spacing.

J5-62626-15-N

5 Point Junction, with two 200 Amp Bushing Well Interfaces and three 600 Amp Bushing Interfaces, alternating Interfaces starting with the 600 Amp. 15kV, No Parking Stand. Standard 4 inch spacing.
15/25kV 600 Series Deadbreak Bushing Extender (without Stud)

K655BEN

15/25kV 600 Series Deadbreak Bushing Extender (without Stud)
15/25kV 600 Series Deadbreak Bushing Extender (with Stud), Pack of 20.

K655BE-20 PACK

15/25kV 600 Series Deadbreak Bushing Extender (with Stud), Pack of 20.
15/25kV 600 Series Deadbreak Bushing Extender (with Stud). Pallet packed with 330 boxes.

K655BE-330LOT

15/25kV 600 Series Deadbreak Bushing Extender (with Stud). Pallet packed with 330 boxes.

Frequently Asked Questions

What is the maximum operating voltage for the K656LR elbow connector?

For the 15kV voltage class, the maximum operating voltage is 8.3kV phase-to-ground and 14.4kV phase-to-phase. For the 28kV voltage class, it is 16.2kV phase-to-ground and 28kV phase-to-phase.

What conductor sizes can the K656LR handle?

The K656LR can be used with conductor sizes ranging from #2 AWG to 1250 kcmil for both aluminum and copper conductors.

What is the acceptable insulation diameter range for this elbow connector?

The K656LR is designed for insulation diameters ranging from 0.640 inches to 1.935 inches.

What standards does the K656LR meet?

The K656LR meets ANSI/IEEE Standard 386, Latest Revision.

What is the continuous current rating for the K656LR?

The K656LR has a continuous current rating of 600 Amps.

What is the momentary current rating for the K656LR?

The K656LR has a momentary current rating of 25kA Sym for 10 Cycles.

What is the impulse withstand rating for the 28kV voltage class?

For the 28kV voltage class, the impulse withstand rating is 140kV BIL (1.2 x 50 microsecond wave).

What is the AC one-minute withstand voltage for the 15kV voltage class?

The AC one-minute withstand voltage for the 15kV voltage class is 34kV.

What is the corona extinction rating for the 28kV voltage class?

The corona extinction rating for the 28kV voltage class is 21.5kV AC at 3pC sensitivity.

Can the K656LR be installed on metallic tape shield or drain wire cable?

Yes, but an ECS cable seal grounding device for safety is highly recommended when used on metallic tape shield or drain wire cable.

How to Install Elastimold Deadbreak Elbow Connectors (655/675LR & K655/K675LR)

This guide provides step-by-step instructions for the safe installation, cable preparation, and connection of Elastimold 655/675LR and K655/K675LR deadbreak elbow connectors for high voltage systems.

Estimated time: 1h 30m

Tools needed:

Wire strippers, Crimping tool, Wire brush (for aluminum conductor), Hotstick, Suitable voltage sensing device (for capacitive test points), Torque wrench

Supplies needed:

Elbow connector, Cable adapter, Compression lug, Insulating plug (optional), Lubricant (supplied with kit), Threaded stud (if not integral to mating part), No. 14 AWG Copper wire (or equivalent) for grounding, Suitable grounding connector, Silicone lubricant (for test point cap), Waterproofing material (for cable jacket)

  1. Ensure Safety and Inspect Components

    DANGER: All apparatus must be de-energized during installation or removal of parts. Do not touch or move energized products in the work area. This product should be installed only by competent personnel trained in good safety practices involving high voltage electrical equipment. Inspect all parts for damage, verify ratings, and ensure compatibility with mating parts. Check the package contents to confirm completeness and an undamaged state. Have all required tools at hand and maintain cleanliness throughout the procedure.

  2. Assemble Cable and Make Initial Cut

    Assemble the cable in its final position with enough slack to allow for elbow removal. For concentric neutral cable, unwind the concentric neutral wires. Cut the cable 1-3/4 inches (45mm) from the center line of the mating product.

  3. Clean and Prepare Cable

    Clean the outer surface of the cable for a distance of 24 inches (610mm) or up to the bent back concentric neutral wires. Remove the outer jacket (if applicable) and prepare the cable insulation, semi-con shield, and other layers according to the specific cable type and dimensions shown in the documentation (e.g., 9-3/4 inches, 10-3/4 inches, 12-3/4 inches tape markers).

  4. Install Cable Adapter

    Bevel the end of the cable insulation at a 45-degree angle, approximately 1/4 inch (6mm) back. Thoroughly clean and then lubricate the cable insulation, always working toward the semi-con shield. Install the cable adapter, small end first, until it is flush with the edge of the tape marker.

  5. Prepare Conductor Length

    Remove the protruding cable insulation by cutting it even with the end of the cable adapter. Do not cut or nick the cable adapter or the conductor. The length of the exposed conductor must be between 4-1/4 inches and 4-9/16 inches (108mm-116mm). If the length is outside this range, redo the assembly.

  6. Crimp Compression Lug

    For copper conductors, fully insert the conductor into the compression lug. For aluminum conductors, wire brush the conductor and immediately fully insert it into the compression lug. Measure the 'Check Dimension' before crimping; it should be less than 6-3/8 inches. Crimp the compression lug following the instructions supplied with the lug. Wipe all excess inhibitor from the compression lug and cable adapter surface after crimping. The distance from the end of the compression lug to the cable adapter after crimping should be between 6-3/8 inches to 7-1/8 inches (162mm-181mm). If not, redo the assembly.

  7. Install Elbow onto Cable Adapter

    Lubricate the cable adapter and the inside of the elbow's cable entrance. Install the elbow onto the cable adapter until it cannot advance further. Ensure the cable adapter remains flush with the tape marker. If not, reposition the cable adapter. Remove the tape marker.

  8. Prepare Mating Products

    WARNING: DO NOT CONNECT OR DISCONNECT MATING PRODUCTS WHILE ENERGIZED. DO NOT ENERGIZE WHILE DISCONNECTED. Remove protective caps from the elbow and the mating part. Hand tighten the threaded stud supplied with the elbow into the mating part, if the mating part is not already equipped with a stud. Clean and lubricate both the elbow and the mating part with the lubricant supplied, ensuring surfaces remain clean.

  9. Connect Elbow to Mating Part

    Push the elbow onto the mating part, carefully lining up the hole in the compression lug with the stud on the mating part.

  10. Connect Opposite Mating Part (if applicable)

    Clean and lubricate the mating part for the opposite end of the elbow. Insert this mating part into the elbow, engage the threads, and hand tighten. Torque the mating part according to the instructions supplied with that specific mating part.

  11. Install Insulating Plug (if used)

    If an insulating plug is used as a mating part, clean and lubricate the inner surface of the voltage detection cap. Place the cap on the elbow and push down hard until it snaps into place.

  12. Ground the Cable Shield and Waterproof

    Insert one end of a piece of wire with ampacity at least equivalent to No. 14 AWG Copper through the grounding eye and twist to make a small loop, taking care not to damage the eye. Connect this wire to ground using a suitable connector. The shield of the cable must be grounded; ground it according to the instructions supplied with the grounding device, or through an alternate method if no device is used. It is also recommended to waterproof the cable jacket at this point to prevent moisture from entering the cable.

  13. Perform Final Torque Check (for 600amp L-Kits)

    CAUTION: When constructing 600amp L-Kits, ensure each component is tightened to the specified torque per the instructions provided with the L-Kit.

  14. Perform Voltage Test

    Remove the test point cap with a hotstick, peeling it off at an angle rather than pulling directly in line with the test point assembly. WARNING: The voltage test point is a capacitance device and is not directly connected to the conductor. Do not use conventional voltage measuring equipment. Follow the manufacturer’s directions for the meter used. Test with a suitable sensing device, made for use with separable connectors manufactured with capacitive test points, to determine if the cable is energized. Contamination, moisture, dirt, or using the wrong equipment can provide a false 'no voltage' indication. To prevent serious or fatal injury, treat the elbow as energized until the 'no voltage' test point indication is confirmed by other means. After voltage detection, clean and lubricate the inside surface of the cap with silicone lubricant and replace it on the test point.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.