ABB Installation Products K656RLR-K0300 600 Amp, 15/25kV, 600 Series Deadbreak, Replacement Elbow with Test Point, Cable…
UPC: 783786486045
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- 600 Amp current rating for robust power handling
- 15/25kV voltage class suitable for medium voltage systems
- 600 Series Deadbreak design for reliable termination
- Accommodates cable insulation diameters from 1.090" to 1.310"
- Aluminum compression lug for secure conductor connection
Specifications
Amperage Rating | 600 A |
Application | Used where Cable has been severed and is not long enough to reach the Elbow |
Color | Black |
Conductor Range | 350 kcmil , 400 kcmil |
Connection | Compression |
Environmental Conditions | All Weather Conditions |
Insulation | True |
Length | 31.56 in |
Length | 801.624 mm |
Material | Housing - EPDM-Rubber |
Special Features | Fully Shielded, Fully Submersible Molded Rubber Housing, 100 Percent Peroxide-Cured Construction includes Insulation and Conductive EPDM Rubber. Can be easily connected or disconnected using standard hand tools and equipment in a de-energized state. Non-Corrosive Capacitive Test Point |
Standard | ANSI/IEEE Standard 386 |
Temperature Rating, Maximum | 149 F |
Temperature Rating, Maximum | 65 C |
Temperature Rating, Minimum | -40 F |
Temperature Rating, Minimum | -40 C |
Type | Deadbreak Replacement Elbow Connector with Test Point |
Voltage Rating | 15 to 25 kV |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 1.0000 L |
Package Weight (Metric) | 0.4540 kg |

K655LR-K0300-S
600 Series Elbow with insulated plug, cap, stud, lug and cable adapter, 15/25KV, Cable Insulation Diameter 1.090 inch to 1.310 inch. Aluminum Compression Lug. Conductor Size kcmil Compressed/Stranded 350 or Compact/Solid 400 or mm2 Compact 185. 200ECS Jacket Seal Included.
756LR-P0380-S
35kV 600 Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter). Aluminum Compression Lug. Cable Insulation Diameter 1.725 inch to 1.935 inch. Conductor Size AWG or kcmil, Compressed Stranded 700/750 /Compacted Solid 900. Cold-Shrinkable Jacket Seal Included.
K676LR-L2320
900 Amp, Elbow Connector, with Test Point, with Insulated Plug, Cap, Stud, Lug and Cable Adapter, 15/25KV, Cable Insulation Diameter 1.180 inch to 1.465 inch. Copper Compression Lug. Conductor Size Compressed Stranded 450 kcmil or Compacted Solid 500/550 kcmil.
K655RLR-L0380
600 Amp, 15/25KV, DeadBreak, Replacement Elbow, Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 700/750 /Compacted Solid 900.
K151LS-C1270
15/25KV, 200 Amp, Dead Break, Locking Splice/Repair Splice, .805 - 1.060 inch Cable Insulation Diameter, Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67.
K151LYFAB1220
Locking Y Splice, 15/25KV, 200 Amp. DeadBreak, Cable Insulation Diameter 0.625 inch to 0.735 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded #2/Solid #1/mmSquared 33.62.
K151LYFG1220
Locking Y Splice, 15/25KV, 200 Amp. DeadBreak, Cable Insulation Diameter 0.725 inch to 0.835 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded #2/Solid #1/mmSquared 33.62.
K676LR-M2410
900 Amp, 15/25kV, 600 Series Elbow with Test Point, with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Cable Insulation Diameter 1.370 inch to 1.630 inch. Copper Compression Lug. Conductor Size Compressed Stranded 1000 kcmil. No Sealing Kit.Frequently Asked Questions
What is the maximum cable insulation diameter for this elbow?
The ABB K656RLR-K0300 accommodates cable insulation diameters ranging from 1.090 inches to 1.310 inches.
What conductor sizes can be used with this deadbreak elbow?
This elbow supports compressed stranded aluminum conductors up to 350 kcmil, compacted solid aluminum up to 400 kcmil, and compact mm² conductors up to 185 mm².
What is the voltage rating of the K656RLR-K0300 elbow?
The ABB K656RLR-K0300 is rated for 15/25kV applications.
Does this deadbreak elbow have a test point?
Yes, the ABB K656RLR-K0300 is a replacement elbow with a built-in test point.
What type of lug is included with this ABB elbow?
The K656RLR-K0300 features an aluminum compression lug for conductor connection.
How to Install the K655RLR High Voltage Connector
This guide provides step-by-step instructions for the safe and proper installation of the K655RLR connector, designed for high voltage apparatus up to 28kV class systems where cable length is limited.
Estimated time: 2h
Tools needed:
Hex wrench (supplied), Torque wrench (with 9/16-inch socket), Wire strippers, Approved safety solvent, Rag, Wire brush (for aluminum cable), 650ATY assembly tool (optional), 600RRT assembly tool (optional), Hotstick, Suitable sensing device
Supplies needed:
K655RLR kit components (Elbow, Cable Adapter, Compression Connector, Insulating Plug, Receptacle, Test Point Cap, “I” Adapter, Bolt & Washer Prepack, Retaining Ring, Lubricant, Nylon Venting Rod), Threaded stud (if mating part not equipped), Semi-con sleeve (if needed), Electrical tape, No 14 AWG copper wire (or equivalent), Suitable connectors (for grounding), Silicone grease (for test point cap)
- Initial Safety and Component Preparation
DANGER: Ensure all apparatus is de-energized before beginning installation. This product must only be installed by competent personnel trained in high voltage electrical equipment safety practices. Inspect all K655RLR kit components for damage, proper rating, and compatibility with mating parts. Remove protective caps from the elbow and clean and lubricate the 'I' adapter and the inside of the elbow with the supplied lubricant. Assemble the 'I' adapter into the elbow, ensuring the spade contact bottoms and the flat side of the 'I' contact faces away from the apparatus.
- Connect Elbow to Mating Apparatus
Remove protective caps from the mating apparatus. If the mating part is not equipped with a stud, hand tighten the supplied threaded stud into it. Clean and lubricate both the elbow and the mating part. Carefully position the elbow so the flat side of the 'I' contact faces away from the apparatus, then push the elbow onto the mating part, aligning the 'I' adapter lug hole with the stud. For the opposite end, clean and lubricate its mating part, insert it into the elbow, engage threads, hand tighten, and then torque according to the mating part's instructions. If using an insulating plug, clean and lubricate its voltage detection cap and snap it into place on the elbow.
- Prepare Cable for Connection
Slide the receptacle housing onto the cable. Measure and cut the cable 1 3/4 inches from the center of the 'I' adapter's bolt hole. Remove the semi-con shield 1 1/8 inches from the center of the bolt hole; restore with a semi-con sleeve if the dimension exceeds this. Wrap two turns of tape 1 inch from the end of the semi-con shield as a marker. Bevel the insulation end at a 45-degree angle, approximately 1/4 inch back. Thoroughly clean the insulation with an approved safety solvent, wiping from the cable end towards the outer jacket to remove all semi-conducting residue.
- Install Cable Adapter and Retaining Ring
Apply supplied lubricant sparingly along the cable and lubricate the inside of the cable adapter. Slide the adapter, small end first, over the cable with a twisting motion until it is flush with the tape marker. Carefully cut the protruding cable insulation even with the end of the cable adapter, ensuring not to nick the adapter or conductor. The exposed conductor length should be between 4 3/16 inches and 5 1/8 inches; if not, redo the assembly. Assemble the aluminum retaining ring over the conductor, snugging it firmly against the cable adapter. Tighten the socket head screw using the supplied hex wrench until the wrench twists. Verify the exposed conductor length is now between 4 5/16 inches and 4 5/8 inches.
- Prepare and Crimp Compression Connector
Remove the protective cap from the compression connector. If using aluminum cable, wire brush the conductor and immediately insert it fully into the crimp connector, which contains an inhibitor. Bolt the crimp connector onto the 'I' Adapter and tighten to 25 ft-lbs to ensure proper positioning. Train the cable into its final position and mark alignment points on the retaining ring and the outside surface of the crimp connector. Remove the bolted contact from the 'I' Adapter, align the marks, and crimp the connectors according to their instructions, rotating each crimp 90 or 180 degrees. After crimping, measure the distance from the end of the connector to the holding collar; if it exceeds 7 1/8 inches, recheck all previous work.
- Final Assembly and Torque
Ensure the flat surface of the 'I' Adapter aligns perfectly with the flat surface on the crimp connector, with no gaps. Assemble the washers and bolt in the following order: flat washer against the spade contact, then the Belleville washer (concave side down), followed by the hex-head bolt. Hand tighten the bolt. Using a torque wrench with a 9/16-inch socket, tighten the bolt to 50 to 60 ft-lbs. Do not attempt to move or reposition any part of the assembly after the bolt is tightened. Clean and lubricate the outside of the cable adapter and the 'I' adapter with the supplied lubricant.
- Install Receptacle Housing and Grounding
Slide the receptacle housing over the cable adapter and into position. Insert the supplied nylon venting rod. Use either the 650ATY or 600RRT assembly tool (refer to tool-specific instructions and warnings) to slowly slide the receptacle housing over the splice section. Remove the vent rod. After removing the assembly tool, rotate the receptacle approximately 1/8 revolution clockwise, then 1/8 revolution counterclockwise to ensure it is properly seated. For concentric neutral cable, connect a short length of No 14 AWG copper wire (or equivalent) to the grounding eyes of the housings, twisting tightly. Gather and connect all concentric neutral wires and grounding wires using suitable connectors. Ground the metallic shield of the cable according to standard utility practices and waterproof the cable jacket if applicable.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.