Authorized ABB Distributor (Installation Products)
ABB - Installation Products K676LR-M2410 - 900 Amp, 15/25kV, 600 Series Elbow with Test Point, with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Cable Insulation Diameter 1.370 inch to 1.630 inch. Copper Compression Lug. Conductor Size Compressed Stranded 1000 kcmil. No Sealing Kit.

ABB Installation Products K676LR-M2410 900 Amp, 15/25kV, 600 Series Elbow with Test Point, with Insulated Plug, Cap, Stud, Lug…

UPC: 075114230520


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB K676LR-M2410 is a 900 Amp, 15/25kV 600 Series elbow connector designed for medium-voltage cable systems. This elbow features a built-in test point for safe voltage verification without cable disconnection, an insulated plug and cap for enhanced safety, and a copper compression lug rated for 1000 kcmil compressed stranded conductors. The cable insulation diameter range of 1.370 to 1.630 inches ensures compatibility with a wide range of medium-voltage cables. The unit includes a stud for secure mechanical and electrical connection, and a cable adapter for proper alignment and strain relief. This elbow is part of ABB's 600 Series, a trusted line of medium-voltage connectors used in industrial, utility, and commercial power distribution systems. The absence of a sealing kit allows for flexible installation configurations while maintaining compliance with applicable standards for medium-voltage cable accessories.
  • 900 Amp rated for medium-voltage applications
  • 15/25kV voltage rating with built-in test point
  • Compatible with 1.370" to 1.630" cable insulation diameters
  • 1000 kcmil copper compression lug for 1000 kcmil conductors
  • Includes insulated plug, cap, stud, and cable adapter

Specifications

Amperage Rating
900 A
Application
Designed to provide Fully Shielded, Dead-Front Submersible Cable Connections to High-Voltage Apparatus
Color
Black
Conductor Range
1000 kcmil
Connection
Compression
Connection Type
Compression Lug
Current Rating
900 A
Environmental Conditions
All Weather Conditions
Insulation
True
Length
13 in
Length
330.2 mm
Material
Copper
Material
Housing - EPDM-Rubber
Series
600
Size
Cable Insulation Diameter 1.370 inch to 1.630 inch
Special Features
Fully Shielded, Fully Submersible Molded Rubber Housing, 100 Percent Peroxide-Cured Construction includes Insulation and conductive EPDM materials. Can be easily connected or disconnected using standard hand tools and Equipment in a de-energized State. Non-Corrosive Capacitive Test Point
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Deadbreak Elbow Connector with Test Point
Voltage Rating
15 to 25 kV
Voltage Rating
15/25 kV
Width
10.36 in
Width
263.144 mm
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
900 Amp, 15/25kV, 600 Series Elbow with Test Point, with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Cable Insulation Diameter 1.515 inch to 1.780 inch. Copper Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 1000.

K676LR-N2410

900 Amp, 15/25kV, 600 Series Elbow with Test Point, with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Cable Insulation Diameter 1.515 inch to 1.780 inch. Copper Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 1000.
Copper-coated conductor 1,90m 63A x2

173G0412

Copper-coated conductor 1,90m 63A x2
Solenoid Valve Connectors, Accessory, Thumb screw, Cabled Form A, B, ISB, and FW ISC

V-25TB

Solenoid Valve Connectors, Accessory, Thumb screw, Cabled Form A, B, ISB, and FW ISC
600 Amp, 15/25kV, 600 Series Deadbreak, Replacement Elbow with Test Point, Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Compression Lug. Conductor Size Compressed Stranded 4/0 AWG or Compacted Solid 250 kcmil. With Sealing Kit - Cold Shrinkable Jacket Seal.

K656RLR-H0270-S

600 Amp, 15/25kV, 600 Series Deadbreak, Replacement Elbow with Test Point, Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Compression Lug. Conductor Size Compressed Stranded 4/0 AWG or Compacted Solid 250 kcmil. With Sealing Kit - Cold Shrinkable Jacket Seal.
15-25kV, 600 Amp, Replacement Elbow. Aluminum Compression Lug. Cable Insulation Diameter 1.090 inch to 1.310 inch. Conductor Size AWG or kcmil, Compressed Stranded 500 /Compacted Solid 600 /mmSquared Compact 250/300. Cold-Shrinkable Jacket Seal Included.

K656RLR-K0330-S

15-25kV, 600 Amp, Replacement Elbow. Aluminum Compression Lug. Cable Insulation Diameter 1.090 inch to 1.310 inch. Conductor Size AWG or kcmil, Compressed Stranded 500 /Compacted Solid 600 /mmSquared Compact 250/300. Cold-Shrinkable Jacket Seal Included.
15-25kV, 600 Amp, Replacement Elbow. Aluminum Compression Lug. Cable Insulation Diameter 1.090 inch to 1.310 inch. Conductor Size AWG or kcmil, Compressed Stranded 500 /Compacted Solid 600 /mmSquared Compact 250/300. With Cold Shrinkable Seal with Copper Braid and Constant Force Spring.

K656RLR-K0330-SG3

15-25kV, 600 Amp, Replacement Elbow. Aluminum Compression Lug. Cable Insulation Diameter 1.090 inch to 1.310 inch. Conductor Size AWG or kcmil, Compressed Stranded 500 /Compacted Solid 600 /mmSquared Compact 250/300. With Cold Shrinkable Seal with Copper Braid and Constant Force Spring.
900 Amp, 15/25kV, 600 Series Elbow with Test Point, with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Cable Insulation Diameter 1.370 inch to 1.630 inch. Copper Compression Lug. Conductor Size Compressed Stranded 700/750 kcmil or Compacted Solid 900 kcmil. No Sealing Kit.

K676LR-M2380

900 Amp, 15/25kV, 600 Series Elbow with Test Point, with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Cable Insulation Diameter 1.370 inch to 1.630 inch. Copper Compression Lug. Conductor Size Compressed Stranded 700/750 kcmil or Compacted Solid 900 kcmil. No Sealing Kit.
600 Amp, 15/25kV, 600 Series Deadbreak, Replacement Elbow without Test Point, Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 1000.

K655RLR-N-0410

600 Amp, 15/25kV, 600 Series Deadbreak, Replacement Elbow without Test Point, Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 1000.

Frequently Asked Questions

What is the maximum conductor size?

The elbow accommodates 1000 kcmil compressed stranded copper conductors.

Does this elbow include a sealing kit?

No, the K676LR-M2410 does not include a sealing kit.

Is a test point included?

Yes, the elbow features a built-in test point for voltage verification.

What voltage ratings does this elbow support?

The K676LR-M2410 supports 15kV and 25kV medium-voltage applications.

What cable insulation diameters are compatible?

The elbow fits cable insulation diameters from 1.370 to 1.630 inches.

How to Install Elastimold 655/675LR Deadbreak Elbow Connectors

This guide provides step-by-step instructions for the safe installation and wiring of Elastimold 655/675LR and K655/K675LR deadbreak elbow connectors, including cable preparation and initial connection procedures for high voltage systems.

Estimated time: 1h 30m

Tools needed:

Cable cutting tool, Cable stripping tool, Wire brush, Crimping tool, Hotstick, Suitable voltage sensing device, Torque wrench

Supplies needed:

Elbow connector (655/675LR or K655/K675LR), Cable adapter, Compression lug, Insulating plug (if used), Lubricant (silicone), Threaded stud (if not pre-equipped), Grounding wire (min. No. 14 AWG Copper), Suitable grounding connector, Waterproofing material (for cable jacket), HV insulated caps (if replacing shipping covers)

  1. Prepare Work Area and Cable

    DANGER: De-energize all apparatus during installation. Assemble the cable in its final position with enough slack. Clean the outer surface of the cable for a distance of 24 inches (610mm). Prepare the cable by removing the outer jacket (if applicable) and semi-con shield to the specified dimensions as per the cable type (e.g., non-jacketed, jacketed, Unishield, or lead sheath).

  2. Prepare Cable Insulation and Install Cable Adapter

    Bevel the end of the cable insulation at a 45-degree angle, approximately 1/4 inch (6mm) back. Thoroughly clean and then lubricate the cable insulation, working towards the semi-con shield. Install the cable adapter, small end first, until it is flush with the edge of the tape marker.

  3. Prepare Conductor and Crimp Compression Lug

    Remove the protruding cable insulation by cutting it even with the end of the cable adapter, ensuring not to nick the adapter or conductor. The exposed conductor length must be between 4-1/4 inches and 4-9/16 inches (108mm-116mm). For aluminum conductors, wire brush the conductor immediately before fully inserting it into the compression lug. Crimp the compression lug following the instructions supplied with the lug. Wipe all excess inhibitor from the lug and cable adapter surface. Verify the distance from the end of the compression lug to the cable adapter is between 6-3/8 inches to 7-1/8 inches (162mm-181mm).

  4. Install Elbow Connector

    Lubricate the cable adapter and the inside of the elbow cable entrance. Install the elbow onto the cable adapter until it cannot advance further. Ensure the cable adapter remains flush with the tape marker. Reposition if necessary. Remove the tape marker.

  5. Connect to Mating Product

    DANGER: Do not connect or disconnect mating products while energized. Do not energize while disconnected. Remove protective caps from the elbow and the mating part. Hand tighten the threaded stud (if the mating part is not equipped) into the mating part. Clean and lubricate both the elbow and the mating part with the supplied lubricant. Push the elbow onto the mating part, aligning the hole in the compression lug with the stud on the mating part.

  6. Connect Opposite End and Ground Cable Shield

    Clean and lubricate the mating part for the opposite end of the elbow. Insert the mating part into the elbow, engage the threads, and hand tighten. Torque the mating part according to its supplied instructions. Insert one end of a grounding wire (at least equivalent to No. 14 AWG Copper) through the grounding eye and twist to make a small loop. Connect this wire to ground using a suitable connector. Ground the cable shield according to the instructions supplied with the grounding device or an alternate method. Waterproof the cable jacket at this point to prevent moisture ingress.

  7. Perform Voltage Test (Optional)

    If performing a voltage test, remove the test point cap with a hotstick, peeling it off at an angle. WARNING: The voltage test point is a capacitance device; do not use conventional voltage measuring equipment. Use a suitable sensing device made for capacitive test points to determine if the cable is energized. Contamination or incorrect equipment can provide a false 'no voltage' indication. Treat the elbow as energized until the 'no voltage' indication is confirmed by other means. After testing, clean and lubricate the inside surface of the cap with silicone lubricant and replace it on the test point.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.