Authorized ABB Distributor (Installation Products)
ABB - Installation Products 756LR-P0380-S - 35kV 600 Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter). Aluminum Compression Lug. Cable Insulation Diameter 1.725 inch to 1.935 inch. Conductor Size AWG or kcmil, Compressed Stranded 700/750 /Compacted Solid 900. Cold-Shrinkable Jacket Seal Included.

ABB Installation Products 756LR-P0380-S 35kV 600 Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and…

UPC: 783786826537


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB 756LR-P0380-S 35kV 600 Series Deadbreak Elbow with Test Point is a fully insulated, deadbreak-rated elbow connector engineered for reliable 35kV underground distribution systems. This deadbreak elbow meets ANSI/IEEE Standard 386 and delivers a fully shielded, dead-front submersible cable connection to high-voltage apparatus. The integrated test point enables safe voltage verification without service interruption, making it ideal for switchgear, transformers, and pad-mounted equipment. The unit includes an aluminum compression lug rated for 700/750 kcmil compressed stranded or 900 kcmil compacted solid conductors, ensuring compatibility with high-capacity cable systems. The cold-shrinkable jacket seal provides a moisture-resistant, mechanically secure interface for cable insulation diameters between 1.725 and 1.935 inches. The integrated insulated plug, cap, stud, and cable adapter components eliminate the need for additional hardware, streamlining installation while maintaining dielectric integrity. Constructed from corrosion-resistant aluminum and peroxide-cured EPDM materials, this deadbreak elbow delivers long-term reliability in underground and indoor applications. Typical uses include utility substations, commercial/industrial power distribution, and renewable energy interconnections where deadbreak operation is required for safe maintenance and testing. The 600 Series design aligns with ABB’s proven deadbreak technology, offering a field-proven solution for medium-voltage cable terminations with ratings up to 21.1kV phase-to-ground, 36.6kV phase-to-phase, 600A continuous current, and 25kA symmetrical momentary current.
  • 35kV rated deadbreak elbow with integrated test point for safe voltage verification
  • Aluminum compression lug compatible with 700/750 kcmil compressed stranded or 900 kcmil compacted solid conductors
  • Cold-shrinkable jacket seal for moisture-resistant, mechanically secure cable interface (1.725-1.935" insulation diameter)
  • Fully shielded, submersible molded rubber housing with peroxide-cured EPDM materials
  • Meets ANSI/IEEE Standard 386 with 600A continuous current and 25kA symmetrical momentary rating

Specifications

Amperage Rating
600 A
Application
35 kv, 600 Amp
Color
Black
Conductor Range
700 to 750 kcmil , 900 kcmil
Connection
Compression
Connection Type
Cold-Shrinkable Jacket Seal, Compression Lug
Environmental Conditions
Fully Submersible
Insulation
True
Material
Aluminum, Polymer
Material
Housing - EPDM-Rubber
Series
600 Series
Size
Cable Insulation Diameter 1.725 inch to 1.935 inch
Special Features
35kV, 600 Amp Loadbreak Elbow. Fully shielded, fully submersible molded rubber housing. 100 percent peroxide-cured construction includes insulation and conductive EPDM materials. Can be easily connected or disconnected using standard hand tools and equipment in a de-energized state. S - Cold-Shrinkable Jacket Seal
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Deadbreak Elbow Connector with Test Point
Voltage Rating
35 kV
Width
12.28 in
Width
311.912 mm
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
35kV 600 Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter). Aluminum Compression Lug. Cable Insulation Diameter 1.725 inch to 1.935 inch. Conductor Size AWG or kcmil, Compressed Stranded 700/750 /Compacted Solid 900.

756LR-P0380

35kV 600 Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter). Aluminum Compression Lug. Cable Insulation Diameter 1.725 inch to 1.935 inch. Conductor Size AWG or kcmil, Compressed Stranded 700/750 /Compacted Solid 900.
900 Amp, Elbow Connector, with Test Point, with Insulated Plug, Cap, Stud, Lug and Cable Adapter, 15/25KV, Cable Insulation Diameter 1.180 inch to 1.465 inch. Copper Compression Lug. Conductor Size Compressed Stranded 450 kcmil or Compacted Solid 500/550 kcmil.

K676LR-L2320

900 Amp, Elbow Connector, with Test Point, with Insulated Plug, Cap, Stud, Lug and Cable Adapter, 15/25KV, Cable Insulation Diameter 1.180 inch to 1.465 inch. Copper Compression Lug. Conductor Size Compressed Stranded 450 kcmil or Compacted Solid 500/550 kcmil.
600 Amp, 15/25KV, DeadBreak, Replacement Elbow, Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 700/750 /Compacted Solid 900.

K655RLR-L0380

600 Amp, 15/25KV, DeadBreak, Replacement Elbow, Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 700/750 /Compacted Solid 900.
15/25KV, 200 Amp, Dead Break, Locking Splice/Repair Splice, .805 - 1.060 inch Cable Insulation Diameter, Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67.

K151LS-C1270

15/25KV, 200 Amp, Dead Break, Locking Splice/Repair Splice, .805 - 1.060 inch Cable Insulation Diameter, Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67.
Locking Y Splice, 15/25KV, 200 Amp. DeadBreak, Cable Insulation Diameter 0.625 inch to 0.735 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded #2/Solid #1/mmSquared 33.62.

K151LYFAB1220

Locking Y Splice, 15/25KV, 200 Amp. DeadBreak, Cable Insulation Diameter 0.625 inch to 0.735 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded #2/Solid #1/mmSquared 33.62.
Locking Y Splice, 15/25KV, 200 Amp. DeadBreak, Cable Insulation Diameter 0.725 inch to 0.835 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded #2/Solid #1/mmSquared 33.62.

K151LYFG1220

Locking Y Splice, 15/25KV, 200 Amp. DeadBreak, Cable Insulation Diameter 0.725 inch to 0.835 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded #2/Solid #1/mmSquared 33.62.
900 Amp, 15/25kV, 600 Series Elbow with Test Point, with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Cable Insulation Diameter 1.370 inch to 1.630 inch. Copper Compression Lug. Conductor Size Compressed Stranded 1000 kcmil. No Sealing Kit.

K676LR-M2410

900 Amp, 15/25kV, 600 Series Elbow with Test Point, with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Cable Insulation Diameter 1.370 inch to 1.630 inch. Copper Compression Lug. Conductor Size Compressed Stranded 1000 kcmil. No Sealing Kit.
600 Amp, 15/25kV, 600 Series Deadbreak, Replacement Elbow with Test Point, Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Compression Lug. Conductor Size Compressed Stranded 4/0 AWG or Compacted Solid 250 kcmil. With Sealing Kit - Cold Shrinkable Jacket Seal.

K656RLR-H0270-S

600 Amp, 15/25kV, 600 Series Deadbreak, Replacement Elbow with Test Point, Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Compression Lug. Conductor Size Compressed Stranded 4/0 AWG or Compacted Solid 250 kcmil. With Sealing Kit - Cold Shrinkable Jacket Seal.

Frequently Asked Questions

What items are included in a 756LR kit?

Each kit contains an elbow connector housing, copper compression lug, stud, insulated plug with cap, lubricant tubes, cable adapter, and installation instructions.

What is the maximum operating voltage for the 756LR?

The 756LR is rated for a 35kV voltage class, with a maximum phase-to-ground operating voltage of 21.1kV.

What is the continuous current rating of this elbow connector?

The 756LR elbow connector has a continuous current rating of 600 Amps.

What conductor types and sizes are compatible with the 756LR?

It is compatible with aluminum and copper conductors ranging from #2 AWG to 1250 kcmil.

What cable insulation diameters does the 756LR support?

The 756LR supports cable insulation diameters from 0.760 inches to 2.120 inches.

What standards does the 756LR elbow connector meet?

The 756LR elbow connector meets ANSI/IEEE Standard 386, Latest Revision.

Is the 756LR elbow connector submersible?

Yes, the 756LR features a fully shielded, fully submersible molded rubber housing.

What is the impulse withstand rating for the 756LR?

The 756LR has a 150kV BIL impulse withstand rating, measured with a 1.2 x 50 microsecond wave.

What items are included in a 756LR kit?

Each kit contains an elbow connector housing, copper compression lug, stud, insulated plug with cap, lubricant tubes, cable adapter, and installation instructions.

What is the impulse withstand rating for the 756LR?

The 756LR has a 150kV BIL impulse withstand rating, measured with a 1.2 x 50 microsecond wave.

How to Install 756/776LR Deadbreak Elbow Connectors

This guide provides step-by-step instructions for the safe and proper installation of 756LR and 776LR Deadbreak Elbow Connectors on 35kV class systems, ensuring fully shielded and submersible cable connections.

Estimated time: 1h 30m

Tools needed:

Cable cutter, Cleaning supplies (rags, solvent), Utility knife, Crimping tool, Wire brush (for aluminum conductors), Hotstick, Suitable voltage sensing device, Torque wrench (if required by mating part instructions)

Supplies needed:

756/776LR Elbow Connector kit (Elbow, Cable Adapter, Compression Lug, Insulating Plug, Crimp connector, Lubricant, Stud Prepack), Grounding wire (minimum No. 14 AWG Copper equivalent), Suitable ground connector, Waterproofing material (for cable jacket), HV insulated cap(s) or connector(s) (if replacing shipping covers)

  1. Perform Pre-Installation Safety Checks

    DANGER: All apparatus must be de-energized during installation or removal of parts. Do not touch or move energized products in the work area. This product should be installed only by competent personnel trained in good safety practices involving high voltage electrical equipment. Inspect all parts for damage, proper rating, and compatibility with mating parts. Ensure all package contents are complete and undamaged, and verify proper fit with cable and/or mating products. Read all instructions thoroughly before beginning.

  2. Position and Clean the Cable

    Position the cable in its final assembled location, ensuring enough slack for adequate clearance to remove elbows. Cut the cable 1-3/4 inches (45mm) from the centerline of the mating product. Clean the outer jacket of the cable for a distance of 24 inches (610mm).

  3. Prepare the Cable

    Follow the specific cable preparation instructions for your cable type (e.g., UNISHIELD, Lead Sheath, Jacketed, Non-Jacketed). Remove the outer jacket (where applicable) and prepare the cable insulation, semi-con shield, and shield wires/tape to the dimensions specified in the provided diagrams. If using a grounding device or cable seal, refer to their specific instructions.

  4. Install the Cable Adapter

    Bevel the end of the cable insulation at a 45-degree angle, approximately 1/4 inch (6mm) back. Thoroughly clean and then lubricate the cable insulation, always working toward the semi-con shield. Install the cable adapter, small end first, until it is flush with the edge of the tape marker.

  5. Prepare the Conductor

    Carefully remove the protruding cable insulation by cutting it even with the end of the cable adapter. Ensure you do not cut or nick the cable adapter or the conductor. Verify that the length of the exposed conductor is between 4-3/8 inches to 4-3/4 inches (111mm-121mm). If not, redo the assembly.

  6. Install and Crimp the Compression Lug

    For copper conductors, fully insert the conductor into the compression lug. For aluminum conductors, wire brush the conductor immediately before fully inserting it into the compression lug. Measure the 'Check Dimension' before crimping; it should be less than 7 inches (178mm). Crimp the compression lug according to the instructions supplied with the lug. Wipe all excess inhibitor from the compression lug and cable adapter surface after crimping. Verify the distance from the end of the compression lug to the cable adapter after crimping is between 6-7/8 inches to 7-5/8 inches (175mm-194mm). If not, redo the assembly.

  7. Install the Elbow

    Lubricate the cable adapter and the inside of the elbow cable entrance. Install the elbow onto the cable adapter until it cannot advance further. Ensure the cable adapter remains flush with the tape marker; reposition if necessary. Remove the tape marker.

  8. Prepare Mating Products

    DANGER: DO NOT CONNECT OR DISCONNECT MATING PRODUCTS WHILE ENERGIZED. DO NOT ENERGIZE WHILE DISCONNECTED. Remove any protective caps from the elbow and the mating part. If the mating part is not equipped with a stud, hand tighten the threaded stud supplied with the elbow into the mating part. Clean and lubricate both the elbow and the mating part with the supplied lubricant, keeping all surfaces clean.

  9. Connect Elbow to Mating Part

    Push the elbow onto the mating part, carefully aligning the hole in the compression lug with the stud on the mating part.

  10. Connect Opposite Mating Part (if applicable)

    If connecting an opposite mating part, clean and lubricate it. Insert the mating part into the elbow, engage the threads, and hand tighten. Torque the mating part according to the instructions supplied with that specific mating part.

  11. Install Insulating Plug (if used)

    If an insulating plug is used as a mating part, clean and lubricate the inner surface of the voltage detection cap. Place the cap on the elbow and push down firmly until it snaps into place. CAUTION: The insulating plug provides a means for detecting system voltage; follow voltage test directions carefully.

  12. Ground the Cable Shield and Waterproof

    Insert one end of a piece of wire (with ampacity at least equivalent to No. 14 AWG Copper) through the grounding eye and twist to make a small loop, taking care not to damage the eye. Connect this wire to ground using a suitable connector. The cable shield must be grounded; follow instructions supplied with any grounding device or use an alternate method. It is also recommended to waterproof the cable jacket at this point to prevent moisture ingress.

  13. Perform Voltage Test

    CAUTION: When constructing 600amp L-Kits, tighten each component to specified torque per plug connector instructions. To test for voltage, remove the test point cap with a hotstick, peeling it off at an angle. WARNING: The voltage test point is a capacitance device, not directly connected to the conductor. Do not use conventional voltage measuring equipment. Use a suitable sensing device designed for capacitive test points and follow its manufacturer’s directions. Contamination or incorrect equipment can give a false 'no voltage' indication. Treat the elbow as energized until the 'no voltage' indication is confirmed by other means to prevent serious injury. After testing, clean and lubricate the inside surface of the cap with silicone lubricant and replace it on the test point.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.