ABB - Installation Products K655LRTP-H0270 - 600 Amp, 25kV, Stick-Op Connector Kit. Aluminum Compression Lug. Cable Insulation Diameter 0.850 inch to 1.050 inch. Conductor Size AWG or kcmil, Compressed Stranded 4/0 /Compacted Solid 250 /mmSquared Compact 125.

ABB Installation Products K655LRTP-H0270 600 Amp, 25kV, Stick-Op Connector Kit. Aluminum Compression Lug. Cable Insulation…

UPC: 783786863303


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB K655LRTP-H0270 Stick-Op Connector Kit is a 600 Amp, 25kV-rated compression connector designed for medium-voltage cable terminations. This kit includes an aluminum compression lug compatible with cable insulation diameters ranging from 0.850 inch to 1.050 inch. It supports conductor sizes including AWG or kcmil compressed stranded 4/0, compacted solid 250 mm², and compact 125 mm² configurations. This Stick-Op connector is engineered for reliable, high-amperage terminations in medium-voltage applications such as power distribution, industrial facilities, and utility substations. The compression design ensures a secure, low-resistance connection that maintains integrity under load cycling and environmental stress. The aluminum lug provides corrosion resistance and compatibility with copper or aluminum conductors, reducing installation time compared to traditional bolted or soldered connections. Key applications include transformer terminations, switchgear connections, and motor control centers where 25kV-rated, 600 Amp service is required. The connector’s design accommodates a range of conductor sizes, making it versatile for retrofits or new installations. Installation requires standard compression tools and follows industry standards for medium-voltage terminations.
  • 600 Amp, 25kV-rated medium-voltage connector
  • Aluminum compression lug for 0.850" to 1.050" insulation diameter
  • Supports conductor sizes: 4/0 AWG (compressed stranded), 250 mm² (compacted solid), 125 mm² (compact)
  • Designed for Stick-Op termination systems
  • Compatible with copper or aluminum conductors

Specifications

Amperage Rating
600 to 200 A
Application
Connect 600 Amp interface to 200 Amp Loadbreak Tap
Color
Black
Conductor Range
4/0 STR/COMPR AWG , 250 kcmil
Connection Type
Compression Lug
Current Rating
600 A
Enclosure
Yes, EPDM Rubber
Environmental Conditions
All Weather Conditions
Insulation
True
Material
Aluminum
Material
Housing - EPDM-Rubber
Series
K655LRTP
Size
Cable Insulation Diameter 0.850 inch to 1.050 inch
Special Features
Reducing Tap Plug 600 to 200 Amps. Provides an External Visible Break by Hotstick Removal of the Elbow
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Stick Op Reducing Tap Plug Connector
Voltage Rating
25 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
600 Amp, 25kV, Deadbreak Elbow, Test and Ground Replacement Kit with Test Point. Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 4/0 /Compacted Solid 250 /mmSquared Compact 125. With Insulated Cap.

K656ETP-J0270-DRG

600 Amp, 25kV, Deadbreak Elbow, Test and Ground Replacement Kit with Test Point. Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 4/0 /Compacted Solid 250 /mmSquared Compact 125. With Insulated Cap.
Single cable clamp 150-300mm2 for power terminal type 5

45000034

Single cable clamp 150-300mm2 for power terminal type 5
600 Amp, 15kV, Deadbreak Stick-Op Connector Kit, With Insulated Cap. Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 3/0 /Compacted Solid 4/0 /mmSquared Compact 95.

655LRTP-J0260-DRG

600 Amp, 15kV, Deadbreak Stick-Op Connector Kit, With Insulated Cap. Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 3/0 /Compacted Solid 4/0 /mmSquared Compact 95.
600 Amp, 15kV, Deadbreak Stick-Op Connector Kit, With Insulated Cap. Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 3/0 /Compacted Solid 4/0 /mmSquared Compact 95. 200ECS Cold-Shrinkable Jacket Seal Included.

655LRTP-J0260-DRG-S

600 Amp, 15kV, Deadbreak Stick-Op Connector Kit, With Insulated Cap. Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 3/0 /Compacted Solid 4/0 /mmSquared Compact 95. 200ECS Cold-Shrinkable Jacket Seal Included.
600 Amp, 35kV, Deadbreak, Stick-Op Connector Kit, with Capacitive test point, Aluminum Compression Lug. Cable Insulation Diameter 1.090 inch to 1.310 inch. Conductor Size AWG or kcmil, Compressed Stranded 4/0 /Compacted Solid 250 /mmSquared Compact 125. With Insulated Cap.

756LRTP-K0270-DRG

600 Amp, 35kV, Deadbreak, Stick-Op Connector Kit, with Capacitive test point, Aluminum Compression Lug. Cable Insulation Diameter 1.090 inch to 1.310 inch. Conductor Size AWG or kcmil, Compressed Stranded 4/0 /Compacted Solid 250 /mmSquared Compact 125. With Insulated Cap.
600 Amp, 25kV, Stick-Op Connector Kit. Aluminum Compression Lug. Cable Insulation Diameter 1.090 inch to 1.310 inch. Conductor Size AWG or kcmil, Compressed Stranded 350 /Compacted Solid 400 /mmSquared Compact 185.

K655LRTP-K0300

600 Amp, 25kV, Stick-Op Connector Kit. Aluminum Compression Lug. Cable Insulation Diameter 1.090 inch to 1.310 inch. Conductor Size AWG or kcmil, Compressed Stranded 350 /Compacted Solid 400 /mmSquared Compact 185.
600 Amp, 35kV, Deadbreak, Stick-Op Connector Kit, with Capacitive test point, Aluminum Compression Lug. Cable Insulation Diameter 1.725 inch to 1.935 inch. Conductor Size AWG or kcmil, Compressed Stranded 1000. With Insulated Cap. Cold-Shrinkable Jacket Seal Included.

756LRTP-P0410-DRGS

600 Amp, 35kV, Deadbreak, Stick-Op Connector Kit, with Capacitive test point, Aluminum Compression Lug. Cable Insulation Diameter 1.725 inch to 1.935 inch. Conductor Size AWG or kcmil, Compressed Stranded 1000. With Insulated Cap. Cold-Shrinkable Jacket Seal Included.
600 Amp, 25kV, Deadbreak, Stick-Op Connector Kit with Test Point, Cable Insulation Diameter 1.725 inch to 1.935 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 700/750 /Compacted Solid 900. With Insulated Cap.

K656LRTP-P0380-DRG

600 Amp, 25kV, Deadbreak, Stick-Op Connector Kit with Test Point, Cable Insulation Diameter 1.725 inch to 1.935 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 700/750 /Compacted Solid 900. With Insulated Cap.

Frequently Asked Questions

What is the Corona Extinction rating?

The Corona Extinction rating is 19kV AC at 3pC sensitivity.

What is the maximum operating voltage for this connector kit?

The maximum phase-to-ground operating voltage for the 25kV voltage class is 15.2kV.

What is the continuous current rating of the connector?

The connector has a continuous current rating of 600 Amps.

What standards does the STICK-OP connector meet?

The STICK-OP connector kit meets ANSI/IEEE Standard 386, Latest Revision.

Does this kit include a test point?

No, this specific K655LRTP-W0X STICK-OP Connector Kit is without a test point. For a test point, use K656LRTP.

What is included in the K655LRTP-W0X connector kit?

Each kit contains an elbow housing, a reducing tap plug, a cable size adapter, a compression lug, silicone lubricant, an instruction sheet, and a crimp chart.

What is the impulse withstand rating of the connector?

The connector has a 125kV BIL Impulse Withstand rating, based on a 1.2 x 50 microsecond wave.

What is the momentary current rating?

The momentary current rating is 25kA Symmetrical for 10 Cycles.

Can this connector be used with 900A series applications?

No, for 900A series applications, you should use the K675LRTP connector.

What is the AC one-minute withstand voltage?

The AC one-minute withstand voltage rating for the connector is 40kV AC.

How to Install K655/K675LR Deadbreak Elbow Connectors

This guide provides step-by-step instructions for installing K655/K675LR Deadbreak Elbow Connectors, designed for fully shielded, submersible deadfront cable connections to high voltage apparatus and for splicing 600-ampere or 900-ampere systems.

Estimated time: 1h 30m

Tools needed:

Cable cutter, Wire strippers, Knife, Beveling tool, Crimping tool, Torque wrench, Hotstick, Suitable sensing device (for capacitive test points)

Supplies needed:

K655/K675LR Deadbreak Elbow Connector, Cable adapter, Compression lug, Insulating plug (if applicable), Silicone lubricant, Threaded stud (if needed), Cable (appropriate type for application), Tape marker, No. 14 AWG Copper wire (or equivalent), Grounding connector, HV insulated cap(s) or connector(s)

  1. Prepare Cable for Assembly

    DANGER: All apparatus must be de-energized during installation or removal of parts. Assemble the cable in its final assembled position with enough slack to provide adequate clearance for removing the elbows. For concentric neutral cable, unwind the concentric neutral wires. Cut the cable 1-3/4 inches (45mm) from the center line of the mating product.

  2. Clean Cable Outer Surface

    Clean the outer surface of the cable a distance of 24 inches (610mm) or up to the bent back concentric neutral wires.

  3. Prepare Cable (Jacket Removal and Shield Preparation)

    Remove the outer jacket (where applicable) and prepare the cable as shown in the diagrams, ensuring correct dimensions for cable insulation, semi-con shield, and tape marker. If using a 20MA or 21MA grounding device, 600ECS Jacket Cable Seal, or 10TL cable shield adapter for UNISHIELD* or LEAD SHEATH cable, refer to the specific installation instructions supplied with those products.

  4. Install Cable Adapter

    Bevel the end of the cable insulation at a 45-degree angle, approximately 1/4 inch (6mm) back. Thoroughly clean, then lubricate the cable insulation, always working toward the semi-con shield. Install the cable adapter, small end first, until it is flush with the edge of the tape marker.

  5. Expose Conductor

    Remove the protruding cable insulation by cutting it even with the end of the cable adapter. Do not cut or nick the cable adapter or the conductor. Ensure the length of the exposed conductor is between 4-1/4 inches and 4-9/16 inches (108mm-116mm). If not, redo the assembly.

  6. Crimp Compression Lug

    For copper conductor, fully insert the conductor into the compression lug. For aluminum conductor, wire brush the conductor and immediately fully insert it into the compression lug. Measure the 'Check Dimension' before crimping; it should be less than 6-3/8 inches. If not, redo the assembly. Crimp the compression lug following the crimping instructions supplied with the lug. Wipe all excess inhibitor from the compression lug and cable adapter surface after crimping. Verify the distance from the end of the compression lug to the cable adapter after crimping is between 6-3/8 inches to 7-1/8 inches (162mm-181mm). If not, redo the assembly.

  7. Install Elbow

    Lubricate the cable adapter and the inside of the elbow cable entrance. Install the elbow onto the cable adapter until it cannot advance further. Ensure the cable adapter is still flush with the tape marker. If not, reposition the cable adapter. Remove the tape marker.

  8. Prepare Mating Products

    DANGER: DO NOT CONNECT OR DISCONNECT MATING PRODUCTS WHILE ENERGIZED. DO NOT ENERGIZED WHILE DISCONNECTED. Remove protective caps from the elbow and the mating part. If the mating part is not equipped with a stud, hand tighten the threaded stud supplied with the elbow into the mating part. Clean and lubricate both the elbow and the mating part with the supplied lubricant, keeping surfaces clean.

  9. Connect Elbow to Mating Part

    Push the elbow onto the mating part, aligning the hole in the compression lug with the stud on the mating part.

  10. Connect Opposite Mating Part (if applicable)

    Clean and lubricate the mating part for the opposite end of the elbow. Insert the mating part into the elbow. Engage the threads and hand tighten. Torque the mating part according to its supplied instructions.

  11. Install Insulating Plug (if applicable)

    If an insulating plug is used as a mating part, clean and lubricate the inner surface of the voltage detection cap and place it on the elbow. Push down hard until the cap snaps into place. Follow voltage test directions after this step.

  12. Ground the Cable Shield

    Insert one end of a No. 14 AWG Copper wire (or equivalent ampacity) through the grounding eye and twist to make a small loop, taking care not to damage the eye. Connect the wire to ground using a suitable connector. The shield of the cable must be grounded. Ground according to the instructions supplied with the grounding device. If no grounding device is used, ground the shield through an alternate method. It is also recommended to waterproof the cable jacket at this point to prevent moisture entry.

  13. Torque Components (for 600A L-Kits)

    CAUTION: When constructing 600amp L-Kits, ensure each component is tightened to the specified torque per its instructions.

  14. Perform Voltage Test

    Remove the test point cap with a hotstick, peeling it off at an angle rather than pulling directly. WARNING: The voltage test point is a capacitance device, not directly connected to the conductor. Do not use conventional voltage measuring equipment. Follow the manufacturer’s directions for the specific meter used. Test with a suitable sensing device, designed for separable connectors with capacitive test points, to determine if the cable is energized. To prevent serious or fatal injury, treat the elbow as energized until the 'no voltage' test point indication is confirmed by other means, as contamination, moisture, or incorrect equipment can provide a false 'no voltage' indication. After voltage detection, clean and lubricate the inside surface of the cap with silicone lubricant and replace it on the test point.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.