ABB - Installation Products K656LRTP-P0380-DRG - 600 Amp, 25kV, Deadbreak, Stick-Op Connector Kit with Test Point, Cable Insulation Diameter 1.725 inch to 1.935 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 700/750 /Compacted Solid 900. With Insulated Cap.
ABB - Installation Products

K656LRTP-P0380-DRG

UPC: 783786971749


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Overview

The ABB K656LRTP-P0380-DRG is a 600 Amp, 25kV deadbreak connector kit designed for medium-voltage cable terminations. This kit supports cable insulation diameters from 1.725 to 1.935 inches and is compatible with compressed stranded conductors sized 700/750 kcmil or compacted solid conductors up to 900 kcmil. The kit includes an aluminum compression lug for secure, high-conductivity connections and features a test point for safe voltage verification without cable disconnection. The insulated cap provides additional protection against environmental contaminants and accidental contact. This deadbreak connector is ideal for applications in utility substations, switchgear, transformers, and industrial power distribution systems where reliable, maintenance-free terminations are required. The deadbreak design allows for hot-stick operation, enabling safe installation and removal under load conditions. This connector kit meets industry standards for medium-voltage cable accessories and is suitable for both indoor and outdoor installations.
  • 600 Amp, 25kV deadbreak connector kit
  • Supports cable insulation diameters 1.725" to 1.935"
  • Compatible with 700/750 kcmil compressed stranded or 900 kcmil compacted solid conductors
  • Includes aluminum compression lug and insulated cap
  • Features test point for safe voltage verification without disconnection

Specifications

Amperage Rating
600 to 200 A
Application
Connect 600 Amp interface to 200 Amp Loadbreak Tap
Color
Black
Conductor Range
700 to 750 kcmil , 900 kcmil
Connection Type
Deadbreak, Stick-Op
Current Rating
600 A
Enclosure
Yes, EPDM Rubber
Environmental Conditions
All Weather Conditions
Insulation
True
Material
Housing - EPDM-Rubber
Material
Aluminum
Series
K656LRTP
Size
Cable Insulation Diameter 1.725 inch to 1.935 inch
Special Features
Reducing Tap Plug 600 to 200 Amps. Test Point. Provides an External Visible Break by Hotstick Removal of the Elbow
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Stick Op Reducing Tap Plug Connector with Test Point
Voltage Rating
15 kV
Voltage Rating
25 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
600 Series Elbows with IEEE 386 Capacitive Test Points, 600 Amp, 15kV, Test and Ground Connector Kit, Insulated Cap. Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Compression Lug. Conductor Size Compressed Stranded 700/750 kcmil or Compacted Solid 900 kcmil.

656ETP-M0380-DRG

600 Series Elbows with IEEE 386 Capacitive Test Points, 600 Amp, 15kV, Test and Ground Connector Kit, Insulated Cap. Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Compression Lug. Conductor Size Compressed Stranded 700/750 kcmil or Compacted Solid 900 kcmil.
Single cable clamp 150-300mm2 for power terminal type 5

45000034

Single cable clamp 150-300mm2 for power terminal type 5
15kV, 600 Amp Combo T, carries current. Combo Elbow with bus, stud and cable adapter, lug and insulated cap kit. Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 4/0 /Compacted Solid 250 /mmSquared Compact 125. 200ECS Cold-Shrinkable Jacket Seal Included.

656CETPJ0270DRG-S

15kV, 600 Amp Combo T, carries current. Combo Elbow with bus, stud and cable adapter, lug and insulated cap kit. Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 4/0 /Compacted Solid 250 /mmSquared Compact 125. 200ECS Cold-Shrinkable Jacket Seal Included.
15kV, 200/900 Amp Series Loadbreak, ComboT Elbow with 200 Amp Reducing Tap Plug, Stud, Cable Adapter and Lug Kit without Test Point. Cable Insulation Diameter 1.180-1.465 inches (30.0-37.2mm). Copper Lug, 330-Conductor Size 500 kcmil Stranded/Compressed or 600 kcmil Solid/Compact or 250/300 mmsq. Includes Elbow Housing, Stud, Compression Lug, Tube of Lubricant, Cable Adapter, Installation Instructions and Crimp Chart. No Sealing Kit.

675CETP-L2330

15kV, 200/900 Amp Series Loadbreak, ComboT Elbow with 200 Amp Reducing Tap Plug, Stud, Cable Adapter and Lug Kit without Test Point. Cable Insulation Diameter 1.180-1.465 inches (30.0-37.2mm). Copper Lug, 330-Conductor Size 500 kcmil Stranded/Compressed or 600 kcmil Solid/Compact or 250/300 mmsq. Includes Elbow Housing, Stud, Compression Lug, Tube of Lubricant, Cable Adapter, Installation Instructions and Crimp Chart. No Sealing Kit.
15kV, 600 Amps, Combo T Elbow with Bus Stud, Cable Adapter and Lug. Cable Insulation Diameter 1.515-1.780 inches, Aluminum Lug, Conductor Size 1000 kcmil Stranded/Compressed. Cold Shrinkable Jacket Seal.

656CETP-N0410-DRG-S

15kV, 600 Amps, Combo T Elbow with Bus Stud, Cable Adapter and Lug. Cable Insulation Diameter 1.515-1.780 inches, Aluminum Lug, Conductor Size 1000 kcmil Stranded/Compressed. Cold Shrinkable Jacket Seal.
15kV, 600 Amp Combo T, carries current. Combo Elbow with bus, stud and cable adapter, lug and insulated cap kit. Cable Insulation Diameter 1.515 inch to 1.780 inch. Bi-Metal Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 700/750 /Compacted Solid 900.

656CETP-N5380

15kV, 600 Amp Combo T, carries current. Combo Elbow with bus, stud and cable adapter, lug and insulated cap kit. Cable Insulation Diameter 1.515 inch to 1.780 inch. Bi-Metal Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 700/750 /Compacted Solid 900.
15kv, Combo T, 600 Amps, Dead Break Kit Combo T Elbow with Bus Stud, Cable Adapter, Lug and Insulated Cap. Cable Insulation Diameter 1.515-1.780 inches, Aluminum Lug, Conductor Size 1000 kcmil Stranded/Compressed.

656CETP-N0410-DRG

15kv, Combo T, 600 Amps, Dead Break Kit Combo T Elbow with Bus Stud, Cable Adapter, Lug and Insulated Cap. Cable Insulation Diameter 1.515-1.780 inches, Aluminum Lug, Conductor Size 1000 kcmil Stranded/Compressed.
900 Amp, 15kV, Combo T Connector, Copper, carries current.

675BCETP

900 Amp, 15kV, Combo T Connector, Copper, carries current.

Frequently Asked Questions

What are the benefits of STICK-OP connectors?

STICK-OP connectors allow direct testing and grounding without cable movement, provide an external visible break, and enhance safety in deadfront construction.

What standard does the connector meet?

The connector meets ANSI/IEEE Standard 386, Latest Revision.

How is the connector connected or disconnected?

It can be connected or disconnected using standard safety hand tools and equipment, but only in de-energized conditions.

What is the maximum operating voltage?

The maximum phase-to-ground operating voltage is 15.2kV for the 25kV voltage class.

What is the maximum phase-to-phase voltage?

The maximum phase-to-phase voltage is 26.3kV for the 25kV voltage class.

What is the momentary current rating?

The momentary current rating is 25kA Symmetrical for 10 cycles.

How do I select the correct catalog number for this product?

Select the cable insulation diameter code (W), choose the connector material type, and then select the compression lug code (X) based on conductor size.

What is the continuous current rating?

The continuous current rating for this connector is 600 Amp.

What are the benefits of STICK-OP connectors?

STICK-OP connectors allow direct testing and grounding without cable movement, provide an external visible break, and enhance safety in deadfront construction.

How do I select the correct catalog number for this product?

Select the cable insulation diameter code (W), choose the connector material type, and then select the compression lug code (X) based on conductor size.

How to Install K656/K676LR Deadbreak Elbow Connectors

This guide provides step-by-step instructions for the safe installation and setup of K656/K676LR Deadbreak Elbow Connectors, including cable preparation, lug crimping, and connection to mating apparatus. These connectors are designed for fully shielded, submersible deadfront cable connections on 15kV and 25kV class systems.

Tools needed:

Hotstick, Suitable sensing device for capacitive test points, Wire brush, Crimping tool

Supplies needed:

Elbow connector, Cable adapter, Compression lug, Insulating plug (optional), Lubricant (silicone grease), Threaded stud (if not integrated), Vinyl plastic tape (for flat metallic shield), Tape retainer (for fabric tape shield), Tape marker (for various shields), No. 14 AWG Copper wire for grounding, Suitable grounding connector, HV insulated caps or connectors (to replace shipping covers), 10TL cable shield adapter (for UNISHIELD or LEAD SHEATH cable)

  1. Perform Initial Safety Checks and Inspection

    DANGER: All apparatus must be de-energized during installation or removal of parts. Inspect package contents and all components to ensure they are complete, undamaged, and compatible with mating parts. If the product is supplied with protective shipping covers, remove them and replace with appropriate HV insulated caps or connectors before submerging or energizing the circuit. This product should only be installed by competent personnel trained in high voltage electrical equipment safety practices.

  2. Position and Clean the Cable

    Position the cable so it is located in its final assembled position, ensuring enough slack for adequate clearance when removing elbows. For concentric neutral cable, unwind the concentric neutral wires. Cut the cable 1-3/4” (45mm) from the centerline of the mating product. Clean the outer surface of the cable for a distance of 24” (610mm) or up to the bent-back concentric neutral wires.

  3. Prepare the Cable Jacket and Shield

    Remove the outer jacket to a dimension of 12 3/4” (324mm). Based on your specific cable type (e.g., shield wires, flat metallic tape, fabric tape, longitudinally corrugated, semi-con), follow the corresponding instructions to remove or fold back the shield and install any necessary tape markers or retainers. If using UNISHIELD* CABLE or LEAD SHEATH CABLE, refer to the Installation Instructions supplied with the 10TL cable shield adapter for cable preparation and grounding. Do not cut or nick the cable insulation during this process.

  4. Install Cable Adapter and Prepare Conductor

    Bevel the end of the cable insulation at a 45-degree angle, approximately 1/4” (6mm) back. Thoroughly clean, then lubricate the cable insulation, always working toward the semi-con shield. Install the cable adapter, small end first, until it is flush with the edge of the tape marker. Remove the protruding cable insulation by cutting it even with the end of the cable adapter. Do not cut or nick the cable adapter or the conductor. The length of exposed conductor should be 4 3/8”–4 11/16” (111mm–119mm); otherwise, redo the assembly.

  5. Crimp the Compression Lug

    For copper conductors, fully insert the conductor into the compression lug. For aluminum conductors, wire brush the conductor immediately before fully inserting it into the compression lug. Measure the “Check Dimension” before crimping; this dimension should be less than 6 1/2” (165mm), otherwise redo the assembly. Crimp the compression lug following the crimping instructions supplied with the lug. Wipe all excess inhibitor from the compression lug and cable adapter surface after crimping. The distance from the end of the compression lug to the cable adapter after crimping should be 6 1/2”–7 1/4” (165mm–184mm); otherwise, redo the assembly.

  6. Install the Elbow and Prepare Mating Products

    Lubricate the cable adapter and the inside of the elbow cable entrance. Install the elbow onto the cable adapter until the elbow cannot advance further. Make sure the cable adapter is still flush with the tape marker. If not, reposition the cable adapter. Remove the tape marker. DO NOT CONNECT OR DISCONNECT MATING PRODUCTS WHILE ENERGIZED. Remove protective caps from both the elbow and the mating part. Hand tighten the threaded stud (supplied with the elbow) into the mating part if the mating part is not already equipped with a stud. Clean and lubricate both the elbow and the mating part with the lubricant supplied.

  7. Connect the Elbow to the Mating Apparatus

    Push the elbow onto the mating part, carefully lining up the hole in the compression lug with the stud on the mating part. If connecting a mating part for the opposite end of the elbow, clean and lubricate it, then insert it into the elbow. Engage the threads and hand tighten. Torque the mating part according to the instructions supplied with that specific mating part. CAUTION: When constructing 600amp L-Kits, ensure each component is tightened to the specified torque per instructions provided.

  8. Install Insulating Plug (Optional) and Ground the Cable Shield

    If an insulating plug is used as a mating part, clean and lubricate the inner surface of the voltage detection cap and place it on the elbow. Push down hard until the cap snaps into place. CAUTION: The insulating plug provides a means for detecting system voltage. Insert one end of a piece of wire with ampacity at least equivalent to No. 14 AWG Copper through the grounding eye and twist to make a small loop, without damaging the eye. Connect this wire to ground using a suitable connector. The shield of the cable must be grounded according to the instructions supplied with any grounding device, or through an alternate method if no device is used. It is also recommended that the jacket of the cable be waterproofed at this point to prevent moisture from entering the cable.

  9. Perform Voltage Test (Post-Installation)

    To perform a voltage test, remove the test point cap with a hotstick, peeling it off at an angle rather than pulling directly in line with the test point assembly. WARNING: The voltage test point is a capacitance device and is not directly connected to the conductor. Do not use conventional voltage measuring equipment. Test with a suitable sensing device, made for use with separable connectors manufactured with capacitive test points, to determine if the cable is energized. Treat the elbow as energized until a “no voltage” test point indication is confirmed by other means to prevent serious or fatal injury. After voltage detection, clean and lubricate the inside surface of the cap with silicone grease and replace it on the test point.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.