ABB - Installation Products K655LRTP-K0300 - 600 Amp, 25kV, Stick-Op Connector Kit. Aluminum Compression Lug. Cable Insulation Diameter 1.090 inch to 1.310 inch. Conductor Size AWG or kcmil, Compressed Stranded 350 /Compacted Solid 400 /mmSquared Compact 185.

ABB Installation Products K655LRTP-K0300 600 Amp, 25kV, Stick-Op Connector Kit. Aluminum Compression Lug. Cable Insulation…

UPC: 783786863310


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB Installation Products K655LRTP-K0300 Stick-Op Connector Kit is a 600 Amp, 25kV rated compression connector designed for medium-voltage cable terminations. This kit includes an aluminum compression lug compatible with cable insulation diameters from 1.090 inch to 1.310 inch. The lug supports conductor sizes ranging from 350 kcmil (compressed stranded), 400 kcmil (compacted solid), and 185 mm² (compact). The connector is engineered for reliable, long-term electrical connections in industrial and utility applications where medium-voltage distribution requires secure, high-current terminations. The compression design ensures low contact resistance and mechanical integrity under thermal cycling and mechanical stress. Typical applications include switchgear, transformers, and motor control centers where 25kV class equipment is deployed. The Stick-Op design simplifies installation by allowing direct insertion of the lug onto the bus bar or terminal without additional hardware. This kit is part of ABB’s Installation Products line, known for durable, field-proven components in electrical infrastructure.
  • 600 Amp continuous current rating for medium-voltage applications
  • 25kV rated for compatibility with medium-voltage systems
  • Aluminum compression lug for 350/400 kcmil or 185 mm² compact conductors
  • Accommodates cable insulation diameters from 1.090" to 1.310"
  • Stick-Op design enables direct insertion onto bus bars or terminals

Specifications

Amperage Rating
600 to 200 A
Application
Connect 600 Amp interface to 200 Amp Loadbreak Tap
Color
Black
Conductor Range
350 kcmil , 400 kcmil
Connection Type
Compression Lug
Current Rating
600 A
Enclosure
Yes, EPDM Rubber
Environmental Conditions
All Weather Conditions
Insulation
True
Material
Housing - EPDM-Rubber
Material
Aluminum
Series
K655LRTP
Size
Cable Insulation Diameter 1.090 inch to 1.310 inch
Special Features
Reducing Tap Plug 600 to 200 Amps. Provides an External Visible Break by Hotstick Removal of the Elbow
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Stick Op Reducing Tap Plug Connector
Voltage Rating
25 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
600 Amp Elbow Connector, Stick Op Connector Kit, 25KV, Dead Break, Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 350 /Solid 400 /mmSquared 185.

K655LRTP-L0300-DRG

600 Amp Elbow Connector, Stick Op Connector Kit, 25KV, Dead Break, Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 350 /Solid 400 /mmSquared 185.
Single cable clamp 150-300mm2 for power terminal type 5

45000034

Single cable clamp 150-300mm2 for power terminal type 5
600 Amp, 35kV, Deadbreak, Stick-Op Connector Kit, with Capacitive test point, Aluminum Compression Lug. Cable Insulation Diameter 1.725 inch to 1.935 inch. Conductor Size AWG or kcmil, Compressed Stranded 1000. With Insulated Cap. Cold-Shrinkable Jacket Seal Included.

756LRTP-P0410-DRGS

600 Amp, 35kV, Deadbreak, Stick-Op Connector Kit, with Capacitive test point, Aluminum Compression Lug. Cable Insulation Diameter 1.725 inch to 1.935 inch. Conductor Size AWG or kcmil, Compressed Stranded 1000. With Insulated Cap. Cold-Shrinkable Jacket Seal Included.
600 Amp, 25kV, Deadbreak, Stick-Op Connector Kit with Test Point, Cable Insulation Diameter 1.725 inch to 1.935 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 700/750 /Compacted Solid 900. With Insulated Cap.

K656LRTP-P0380-DRG

600 Amp, 25kV, Deadbreak, Stick-Op Connector Kit with Test Point, Cable Insulation Diameter 1.725 inch to 1.935 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 700/750 /Compacted Solid 900. With Insulated Cap.
15kV, 600 Amp Combo T, carries current. Combo Elbow with bus, stud and cable adapter, lug and insulated cap kit. Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 4/0 /Compacted Solid 250 /mmSquared Compact 125. 200ECS Cold-Shrinkable Jacket Seal Included.

656CETPJ0270DRG-S

15kV, 600 Amp Combo T, carries current. Combo Elbow with bus, stud and cable adapter, lug and insulated cap kit. Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 4/0 /Compacted Solid 250 /mmSquared Compact 125. 200ECS Cold-Shrinkable Jacket Seal Included.
15kV, 200/900 Amp Series Loadbreak, ComboT Elbow with 200 Amp Reducing Tap Plug, Stud, Cable Adapter and Lug Kit without Test Point. Cable Insulation Diameter 1.180-1.465 inches (30.0-37.2mm). Copper Lug, 330-Conductor Size 500 kcmil Stranded/Compressed or 600 kcmil Solid/Compact or 250/300 mmsq. Includes Elbow Housing, Stud, Compression Lug, Tube of Lubricant, Cable Adapter, Installation Instructions and Crimp Chart. No Sealing Kit.

675CETP-L2330

15kV, 200/900 Amp Series Loadbreak, ComboT Elbow with 200 Amp Reducing Tap Plug, Stud, Cable Adapter and Lug Kit without Test Point. Cable Insulation Diameter 1.180-1.465 inches (30.0-37.2mm). Copper Lug, 330-Conductor Size 500 kcmil Stranded/Compressed or 600 kcmil Solid/Compact or 250/300 mmsq. Includes Elbow Housing, Stud, Compression Lug, Tube of Lubricant, Cable Adapter, Installation Instructions and Crimp Chart. No Sealing Kit.
15kV, 600 Amps, Combo T Elbow with Bus Stud, Cable Adapter and Lug. Cable Insulation Diameter 1.515-1.780 inches, Aluminum Lug, Conductor Size 1000 kcmil Stranded/Compressed. Cold Shrinkable Jacket Seal.

656CETP-N0410-DRG-S

15kV, 600 Amps, Combo T Elbow with Bus Stud, Cable Adapter and Lug. Cable Insulation Diameter 1.515-1.780 inches, Aluminum Lug, Conductor Size 1000 kcmil Stranded/Compressed. Cold Shrinkable Jacket Seal.
15kV, 600 Amp Combo T, carries current. Combo Elbow with bus, stud and cable adapter, lug and insulated cap kit. Cable Insulation Diameter 1.515 inch to 1.780 inch. Bi-Metal Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 700/750 /Compacted Solid 900.

656CETP-N5380

15kV, 600 Amp Combo T, carries current. Combo Elbow with bus, stud and cable adapter, lug and insulated cap kit. Cable Insulation Diameter 1.515 inch to 1.780 inch. Bi-Metal Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 700/750 /Compacted Solid 900.

Frequently Asked Questions

What are the main applications of the STICK-OP connector kit?

The STICK-OP connectors allow direct testing and grounding without cable movement. They also provide an external visible break by hotstick removal of the elbow, enhancing safety in deadfront construction.

What components are included in each K655LRTP kit?

Each kit contains a 600 Series Elbow Housing, a STICK-OP Loadbreak Reducing Tap Plug, a Cable Size Adapter, a Compression Lug, Silicone Lubricant, an Instruction Sheet, and a Crimp Chart.

What is the corona extinction voltage at 3pC sensitivity?

The corona extinction voltage is 19kV AC at 3pC sensitivity.

What is the DC 15-minute withstand voltage rating?

The DC 15-minute withstand voltage rating for the connector kit is 78kV.

What is the AC one-minute withstand voltage rating?

The AC one-minute withstand voltage rating for the connector kit is 40kV.

What materials are used in the construction of the connector?

The connector is constructed of EPDM molded rubber with peroxide-cured insulation and jacket. It features an all copper current path.

What is the Basic Impulse Level (BIL) withstand rating?

The Basic Impulse Level (BIL) impulse withstand rating is 125kV, based on a 1.2 x 50 microsecond wave.

What is the continuous current rating of the connector kit?

The connector kit has a continuous current rating of 600 Amps. It is also rated for 25kV, 600/200 Amp Loadbreak.

What is the maximum operating voltage for this connector kit?

For the 25kV Voltage Class, the maximum phase-to-ground operating voltage is 15.2kV, and the maximum phase-to-phase voltage is 26.3kV.

What is the momentary current rating for the connector?

The momentary current rating for the connector is 25kA Symmetrical for 10 Cycles.

How to Install K655/K675LR Deadbreak Elbow Connectors

This guide provides step-by-step instructions for the safe and proper installation of 600-ampere or 900-ampere deadbreak elbow connectors on 15kV and 25kV class systems, ensuring fully shielded and submersible cable connections.

Estimated time: 2h

Tools needed:

Wire strippers, Utility knife, Wire brush (for aluminum conductors), Crimping tool, Torque wrench, Hotstick, Suitable voltage sensing device, Suitable grounding connector

Supplies needed:

K655/K675LR Deadbreak Elbow Connector kit (includes elbow, cable adapter, compression lug, insulating plug, lubricant, stud prepack), Cable (appropriate type and size), Tape marker, Silicone lubricant, No. 14 AWG Copper wire (or equivalent), Grounding device (e.g., 20MA, 21MA, 600ECS) or alternate grounding method, Protective caps (for elbow and mating part), HV insulated cap(s) or connector(s) (if replacing shipping covers), Waterproofing material (for cable jacket), Mating apparatus/bushing/tap plug

  1. De-energize Apparatus and Inspect Components

    DANGER: Ensure all apparatus is de-energized before beginning installation. Do not touch or move energized products. Inspect all kit contents for completeness and damage. Verify all components are compatible with the cable and mating products. Remove any protective shipping covers and replace with appropriate HV insulated caps or connectors before submerging or energizing the circuit.

  2. Prepare the Cable

    Assemble the cable in its final position with enough slack for elbow removal. For concentric neutral cable, unwind the neutral wires. Cut the cable 1-3/4 inches (45mm) from the center line of the mating product. Clean the outer surface of the cable for a distance of 24 inches (610mm) or up to the bent back concentric neutral wires. Remove the outer jacket (if applicable) and prepare the cable insulation, semi-con shield, and shield wires according to the specific cable type and specified dimensions (refer to diagrams for 9-3/4, 10-3/4, and 12-3/4 inch tape markers). If using a 20MA/21MA grounding device or 600ECS Jacket Cable Seal, or UNISHIELD/LEAD SHEATH cable with a 10TL adapter, refer to their specific installation instructions for cable preparation.

  3. Install Cable Adapter and Prepare Conductor

    Bevel the end of the cable insulation at a 45-degree angle, approximately 1/4 inch (6mm) back. Thoroughly clean and then lubricate the cable insulation, working towards the semi-con shield. Install the cable adapter, small end first, until it is flush with the edge of the tape marker. Remove the protruding cable insulation by cutting it even with the end of the cable adapter. Do not cut or nick the cable adapter or the conductor. The length of the exposed conductor must be between 4-1/4 inches and 4-9/16 inches (108mm-116mm); otherwise, redo this assembly step.

  4. Crimp the Compression Lug

    For copper conductors, fully insert the conductor into the compression lug. For aluminum conductors, wire brush the conductor and immediately fully insert it into the compression lug. Measure the 'Check Dimension' before crimping; it should be less than 6-3/8 inches. Crimp the compression lug following the crimping instructions supplied with the lug. Wipe all excess inhibitor from the compression lug and cable adapter surface after crimping. The distance from the end of the compression lug to the cable adapter after crimping must be between 6-3/8 inches and 7-1/8 inches (162mm-181mm); otherwise, redo this assembly step.

  5. Install the Elbow

    Lubricate the cable adapter and the inside of the elbow cable entrance. Install the elbow onto the cable adapter until it cannot advance further. Ensure the cable adapter remains flush with the tape marker; reposition the cable adapter if necessary. Remove the tape marker.

  6. Connect Elbow to Mating Apparatus

    DANGER: DO NOT CONNECT OR DISCONNECT MATING PRODUCTS WHILE ENERGIZED. DO NOT ENERGIZE WHILE DISCONNECTED. Remove protective caps from both the elbow and the mating part. Hand tighten the threaded stud, supplied with the elbow, into the mating part if the mating part is not already equipped with a stud. Clean and lubricate both the elbow and the mating part with the supplied lubricant, ensuring surfaces remain clean. Push the elbow onto the mating part, carefully lining up the hole in the compression lug with the stud on the mating part.

  7. Connect Second Mating Part or Insulating Plug

    If connecting a second mating part, clean and lubricate it. Insert the mating part into the opposite end of the elbow, engage the threads, and hand tighten. Torque the mating part according to its specific instructions. If an insulating plug is used as a mating part, clean and lubricate the inner surface of the voltage detection cap and place it on the elbow, pushing down hard until the cap snaps into place.

  8. Ground the Cable Shield

    Insert one end of a wire with ampacity at least equivalent to No. 14 AWG Copper through the grounding eye and twist to make a small loop, taking care not to damage the eye. Connect this wire to ground using a suitable connector. The cable shield must be grounded; ground it according to the instructions supplied with your grounding device, or through an alternate method if no device is used. It is also recommended to waterproof the cable jacket at this point to prevent moisture ingress.

  9. Perform Voltage Test and Finalize

    CAUTION: For 600-amp L-Kits, ensure each component is tightened to its specified torque. To perform a voltage test, remove the test point cap with a hotstick, peeling it off at an angle rather than pulling directly. WARNING: The voltage test point is a capacitance device, not directly connected to the conductor. Do not use conventional voltage measuring equipment. Use a suitable sensing device designed for capacitive test points to determine if the cable is energized. Contamination, moisture, or incorrect equipment can give a false 'no voltage' indication; treat the elbow as energized until confirmed by other means. After testing, clean and lubricate the inside surface of the cap with silicone lubricant and replace it on the test point.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.