ABB Installation Products K655LR-LM0380-S 15/25kV, 600 Amp, Deadbreak Elbow Connector without Test Point, with Seal kit. Cable…
UPC: 075114340939
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- 15/25 kV Voltage Rating
- 600 Amp Current Rating
- Deadbreak Connection Type
- Aluminum Compression Lug
- Cable Insulation Diameter: 1.280-1.430 inches (32.512-32.322mm)
Specifications
Amperage Rating | 600 A |
Application | Designed to provide Fully Shielded, Dead-Front Submersible Cable Connections to High-Voltage Apparatus |
Color | Black |
Conductor Range | 700 to 750 kcmil , 900 kcmil |
Environmental Conditions | Fully Submersible |
Insulation | True |
Length | 13 in |
Length | 330.2 mm |
Material | Housing - EPDM-Rubber |
Special Features | Fully shielded, fully submersible molded rubber housing. 100 Percent peroxide-cured construction includes insulation and conductive EPDM materials. Can be easily connected or disconnected using standard hand tools and equipment in a de-energized state. Optional accessories allow visible external separation, by-pass, isolation, dead-ending, grounding, and testing as well as adding taps, surge arrestors, and fault current indicators |
Standard | ANSI/IEEE Standard 386 |
Temperature Rating, Maximum | 149 F |
Temperature Rating, Maximum | 65 C |
Temperature Rating, Minimum | -40 F |
Temperature Rating, Minimum | -40 C |
Type | Deadbreak Elbow Connector |
Voltage Rating | 15 to 25 kV |
Width | 10.36 in |
Width | 263.144 mm |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 1.0000 L |
Package Weight (Metric) | 0.4540 kg |

K656CY-L0380
15-25kV 600 Series Deadbreak Separable Wye Joint Package (3-Way) with Test Point. Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 700/750 /Compacted Solid 900.
K656LR-K2260-SG3
1525kV, 600 Amp, Deadbreak Elbow with Test Point. Cable Insulation Diameter 1.090-1.310 inches (27.686-33.274mm). Copper Lug, 3/0 Stranded/Compressed or 4/0 Solid/Compact or 95 mmsq. SG3 - Cold-Shrinkable Seal with Copper Braid and Constant Force Spring.
K655LR-K0270-S
15/25kV, 600 Amp, Deadbreak Elbow Connector without Test Point, with Seal kit. Cable Insulation Diameter 1.090 - 1.310 inches (27.686-33.274mm). Aluminum Compression Lug. Conductor Size 270 - 4/0 Stranded/Compressed or 250 kcmil Solid/Compact.
756LR-M2330
35kV, 600 Amp, Deadbreak Elbow Connector with Test Point, Cable Insulation Diameter 1.370-1.630 inches (34.798-41.402mm), Copper Lug, Conductor Size 330 - 500kcmil Stranded/Compressed, 600kcmil Solid/Compact. Kit Includes Elbow Connector Housing, Stud, Insulated Plug with Cap, Cable Adapter, V.D. Cap-Peroxide, Tube of Lubricant, Crimp Chart and Installations Instructions. 12.28 x 13.93 inches, 3.37 and 3.83 inch diameters.
K656LR-K0330-SG3
15/25kV, 600 Amp, Deadbreak Elbow Connector without Test Point, with Seal kit. Cable Insulation Diameter 1.090 - 1.310 inches (27.686-33.274mm). Aluminum Compression Lug. Conductor Size 330 - 500 kcmil Stranded/Compressed or 600 kcmil Solid/Compact. SG3 - Cold-Shrinkable Seal with Copper Braid and Constant Force Spring.
K656CETP-H0230
25kv, 600 Amp Series, Deadbreak Combo-T. Connector Elbow with Integral 200 Amp Loadbreak Tap Plug with Test Point. Cable Insulation Diameter 0.850-1.050 inches (21.6-26.7 mm). Aluminum Conductor Material, Conductor Code 230 - #1 Stranded/Compressed or 1/0 Solid/Compact. No Sealing Kit.
K656LR-N2400
15/25kV, Deadbreak Elbow Connector with Test Point, 600 Amps, No Sealing Kit. Cable Insulation Diameter 1.550 to 1.780 inches. Copper Connector. Wire Size 400 - 900 kcmil Stranded/Compressed or 1000 kcmil Solid/Compact. 10.36 inches wide, 13.00 inches from bottom edge to center of bushing insert. 3.38 inch Diameter. Includes Elbow Housing, Lug, Stud, Insulated Plug with Cap, Lubricant Tube, Cable Adapter, Installation Instructions and Crimp Chart.
676CETP-J2320-DRG
Combo-T Integral Separable Connector, 900 Amps, Combo-T Elbow Reducing Tap Plug with Stud, Cable Adapter, Lug and Insulated Cap Kit with Test Point. Cable Adapter Sizing-Cable Insulation Diameter Range .980-1.180 inch ( 24.9-30.0mm), Copper Connector, Connector Size 320 - 450 kcmil Stranded/Compressed, 500 kcmil Solid/Compact. DRG - with Insulated Cap.Frequently Asked Questions
What is the maximum operating voltage for this elbow connector?
The K655LR is rated for 15kV voltage class with a maximum operating voltage of 8.3kV phase-to-ground and 14.4kV phase-to-phase. For the 28kV voltage class, it supports 16.2kV phase-to-ground and 28kV phase-to-phase.
What conductor sizes can this elbow connector accommodate?
It can be used with conductor sizes ranging from #2 AWG to 1250 kcmil for both aluminum and copper conductors.
What is the insulation diameter range for compatible cables?
The K655LR is compatible with cables having insulation diameters from 0.640 inches to 1.935 inches.
What are the continuous and momentary current ratings?
The elbow connector has a continuous current rating of 600 Amps and a momentary current rating of 25kA for 10 cycles.
What standards does this product meet?
The K655LR meets ANSI/IEEE Standard 386, Latest Revision.
What is the impulse withstand rating (BIL)?
For the 15kV voltage class, the BIL is 95kV. For the 28kV voltage class, the BIL is 140kV.
What is the AC one-minute withstand voltage rating?
The AC one-minute withstand voltage is 34kV for the 15kV class and 45kV for the 28kV class.
What is the DC fifteen-minute withstand voltage rating?
The DC fifteen-minute withstand voltage is 53kV for the 15kV class and 84kV for the 28kV class.
What is the corona extinction rating?
The corona extinction rating is 11kV AC for the 15kV class and 21.5kV AC for the 28kV class, at 3pC sensitivity.
What materials are used in the construction?
The housing is made of molded rubber, and the 100% peroxide-cured construction includes insulation and conductive EPDM materials.
How to Install Elastimold Deadbreak Elbow Connectors (655/675LR & K655/K675LR)
This guide provides step-by-step instructions for the safe and proper installation of Elastimold 655/675LR and K655/K675LR Deadbreak Elbow Connectors. Ensure all apparatus are de-energized during installation to prevent serious or fatal injury. Installation should only be performed by competent, trained personnel.
Estimated time: 1h 30m
Tools needed:
Cable cutting tool, Wire strippers, Crimping tool, Wire brush, Hotstick, Torque wrench
Supplies needed:
Elbow connector, Cable Adapter, Compression Lug, Insulating Plug, Lubricant, Threaded Stud, Grounding wire (No. 14 AWG Copper equivalent), Suitable grounding connector, HV insulated cap(s) or connector(s)
- Prepare Cable for Assembly
Assemble the cable in its final position with enough slack for elbow removal. For concentric neutral cable, unwind the neutral wires. Cut the cable 1-3/4” (45mm) from the centerline of the mating product. Clean the outer surface of the cable for 24” (610mm) or up to the bent back concentric neutral wires. Refer to specific instructions (A, B, or C) for your cable type to remove the outer jacket (if applicable) and prepare the cable as shown in the diagrams.
- Install Cable Adapter and Prepare Conductor
Bevel the end of the cable insulation at a 45-degree angle, approximately 1/4” (6mm) back. Thoroughly clean and lubricate the cable insulation, working towards the semi-con shield. Install the cable adapter, small end first, until it is flush with the edge of the tape marker. Remove the protruding cable insulation by cutting it even with the end of the cable adapter, ensuring not to cut or nick the adapter or conductor. Verify the exposed conductor length is between 4-1/4” – 4-9/16” (108mm-116mm); otherwise, redo the assembly.
- Crimp Compression Lug
For copper conductors, fully insert the conductor into the compression lug. For aluminum conductors, wire brush the conductor and immediately fully insert it. Measure the 'Check Dimension' before crimping (must be less than 6-3/8”). Crimp the compression lug according to its supplied instructions. Wipe all excess inhibitor from the lug and cable adapter. Verify the distance from the lug end to the cable adapter is between 6-3/8” to 7-1/8” (162mm-181mm) after crimping; otherwise, redo the assembly.
- Install Elbow and Prepare Mating Parts
Lubricate the cable adapter and the inside of the elbow cable entrance. Install the elbow onto the cable adapter until it cannot advance further, ensuring the cable adapter remains flush with the tape marker. Reposition if necessary, then remove the tape marker. Remove protective caps from the elbow and the mating part. Hand tighten the threaded stud (if supplied with elbow) into the mating part if it lacks one. Clean and lubricate both the elbow and the mating part with the supplied lubricant, keeping surfaces clean. DO NOT CONNECT OR DISCONNECT MATING PRODUCTS WHILE ENERGIZED. DO NOT ENERGIZED WHILE DISCONNECTED.
- Connect Elbow to Mating Parts
Push the elbow onto the primary mating part, aligning the hole in the compression lug with the stud. Clean and lubricate the mating part for the opposite end of the elbow. Insert this mating part into the elbow, engage the threads, and hand tighten. Torque the mating part according to its supplied instructions. If an insulating plug is used, clean and lubricate the inner surface of the voltage detection cap and place it on the elbow, pushing until it snaps into place.
- Ground Cable Shield
Insert one end of a No. 14 AWG Copper equivalent wire through the grounding eye and twist to form a small loop, taking care not to damage the eye. Connect this wire to ground using a suitable connector. The cable shield must be grounded either via a grounding device (following its instructions) or an alternate method. It is also recommended to waterproof the cable jacket at this point to prevent moisture ingress.
- Perform Voltage Test (Optional)
If performing a voltage test, remove the test point cap with a hotstick, peeling it off at an angle. WARNING: The voltage test point is a capacitance device, not directly connected to the conductor. Use a suitable sensing device designed for capacitive test points; do not use conventional voltage measuring equipment. Treat the elbow as energized until a 'no voltage' indication is confirmed by other means to prevent serious or fatal injury. After testing, clean and lubricate the inside surface of the cap with silicone lubricant and replace it on the test point.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.