Authorized ABB Distributor (Installation Products)
ABB - Installation Products K656LR-K0330-SG3 - 15/25kV, 600 Amp, Deadbreak Elbow Connector without Test Point, with Seal kit. Cable Insulation Diameter 1.090 - 1.310 inches (27.686-33.274mm). Aluminum Compression Lug. Conductor Size 330 - 500 kcmil Stranded/Compressed or 600 kcmil Solid/Compact. SG3 - Cold-Shrinkable Seal with Copper Braid and Constant Force Spring.

ABB Installation Products K656LR-K0330-SG3 15/25kV, 600 Amp, Deadbreak Elbow Connector without Test Point, with Seal kit. Cable…

UPC: 075114343961


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB K656LR-K0330-SG3 15/25kV Deadbreak Elbow Connector delivers reliable 600 Amp medium-voltage cable terminations with a cold-shrinkable SG3 seal system. Engineered for dead-front, submersible applications, this connector supports cable insulation diameters from 1.090 to 1.310 inches (27.686-33.274mm) and accommodates conductor sizes of 330-500 kcmil stranded/compressed or 600 kcmil solid/compact. The aluminum compression lug ensures secure, corrosion-resistant terminations, while the copper braid and constant force spring within the SG3 seal provide consistent contact pressure and environmental protection. The connector operates continuously at 600A and withstands 25kA symmetrical fault current for 10 cycles. Its fully shielded, molded rubber housing resists moisture and contaminants, enabling safe, de-energized connections and disconnections using standard hand tools. Ideal for medium-voltage power distribution systems, this deadbreak elbow connector eliminates the need for test points, simplifying installation in applications where direct testing at the connector is unnecessary. The included seal kit ensures complete termination integrity, reducing installation time and minimizing risk of electrical faults. ABB’s Installation Products division provides this robust solution for utility, industrial, and commercial electrical infrastructure where reliability and ease of maintenance are paramount.
  • 15/25kV voltage class with 600A continuous current rating
  • Cold-shrinkable SG3 seal with copper braid and constant force spring for secure terminations
  • Supports cable insulation diameters: 1.090–1.310 inches (27.686–33.274mm)
  • Accommodates conductor sizes: 330–500 kcmil stranded/compressed or 600 kcmil solid/compact
  • Aluminum Compression Lug for 330-500 kcmil Stranded/Compressed or 600 kcmil Solid/Compact Conductors

Specifications

Amperage Rating
600 A
Application
15/25kV, 600 Amp Deadbreak Elbow Connection
Color
Black
Conductor Range
500 kcmil , 600 kcmil
Connection Type
Cold-Shrinkable
Connection Type
Compression Lug
Current Rating
600 A
Environmental Conditions
Fully Submersible
Insulation
True
Length
13 in
Length
330.2 mm
Material
Aluminum, Copper
Material
Aluminum
Material
Housing - EPDM-Rubber
Series
K656LR
Size
1.090 - 1.310 inches (27.686-33.274mm)
Size
Conductor Size 330-500 kcmil Stranded/Compressed or 600 kcmil Solid/Compact, Cable Insulation Diameter 1.090-1.310 inches
Special Features
Fully Shielded, Fully Submersible Molded Rubber Housing. 100 percent Peroxide-Cured Construction includes Insulation and Conductive EPDM Materials. Can be Easily Connected or Disconnected using Standard Hand Tools and Equipment in a De-Energized State. Non-Corrosive, Capacitive Test Point. SG3 Seal
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Deadbreak Elbow Connector with Test Point
Voltage Rating
25 kV
Voltage Rating
15/25 kV
Width
10.36 in
Width
263.144 mm
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
600 Amp, 15/25kV, 600 Series Deadbreak, Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Aluminum Compression Lug. Cable Insulation Diameter 0.980 inch to 1.180 inch. Conductor Size kcmil Compressed/Stranded 500 or Compact/Solid 600 or mm2 Compact 250/300.

K655LR-J0330

600 Amp, 15/25kV, 600 Series Deadbreak, Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Aluminum Compression Lug. Cable Insulation Diameter 0.980 inch to 1.180 inch. Conductor Size kcmil Compressed/Stranded 500 or Compact/Solid 600 or mm2 Compact 250/300.
Single cable clamp 150-300mm2 for power terminal type 5

45000034

Single cable clamp 150-300mm2 for power terminal type 5
25kv, 600 Amp Series, Deadbreak Combo-T. Connector Elbow with Integral 200 Amp Loadbreak Tap Plug with Test Point. Cable Insulation Diameter 0.850-1.050 inches (21.6-26.7 mm). Aluminum Conductor Material, Conductor Code 230 - #1 Stranded/Compressed or 1/0 Solid/Compact. No Sealing Kit.

K656CETP-H0230

25kv, 600 Amp Series, Deadbreak Combo-T. Connector Elbow with Integral 200 Amp Loadbreak Tap Plug with Test Point. Cable Insulation Diameter 0.850-1.050 inches (21.6-26.7 mm). Aluminum Conductor Material, Conductor Code 230 - #1 Stranded/Compressed or 1/0 Solid/Compact. No Sealing Kit.
15/25kV, Deadbreak Elbow Connector with Test Point, 600 Amps, No Sealing Kit. Cable Insulation Diameter 1.550 to 1.780 inches. Copper Connector. Wire Size 400 - 900 kcmil Stranded/Compressed or 1000 kcmil Solid/Compact. 10.36 inches wide, 13.00 inches from bottom edge to center of bushing insert. 3.38 inch Diameter. Includes Elbow Housing, Lug, Stud, Insulated Plug with Cap, Lubricant Tube, Cable Adapter, Installation Instructions and Crimp Chart.

K656LR-N2400

15/25kV, Deadbreak Elbow Connector with Test Point, 600 Amps, No Sealing Kit. Cable Insulation Diameter 1.550 to 1.780 inches. Copper Connector. Wire Size 400 - 900 kcmil Stranded/Compressed or 1000 kcmil Solid/Compact. 10.36 inches wide, 13.00 inches from bottom edge to center of bushing insert. 3.38 inch Diameter. Includes Elbow Housing, Lug, Stud, Insulated Plug with Cap, Lubricant Tube, Cable Adapter, Installation Instructions and Crimp Chart.
Combo-T Integral Separable Connector, 900 Amps, Combo-T Elbow Reducing Tap Plug with Stud, Cable Adapter, Lug and Insulated Cap Kit with Test Point. Cable Adapter Sizing-Cable Insulation Diameter Range .980-1.180 inch ( 24.9-30.0mm), Copper Connector, Connector Size 320 - 450 kcmil Stranded/Compressed, 500 kcmil Solid/Compact. DRG - with Insulated Cap.

676CETP-J2320-DRG

Combo-T Integral Separable Connector, 900 Amps, Combo-T Elbow Reducing Tap Plug with Stud, Cable Adapter, Lug and Insulated Cap Kit with Test Point. Cable Adapter Sizing-Cable Insulation Diameter Range .980-1.180 inch ( 24.9-30.0mm), Copper Connector, Connector Size 320 - 450 kcmil Stranded/Compressed, 500 kcmil Solid/Compact. DRG - with Insulated Cap.
600 Amp, 15kV, Combo T Elbow Reducing Tap Plug without Stud, with Cable Adapter, Lug, No Test Point, Aluminum, Cable Insulation Diameter 0.760 inch to 0.950 inch. Conductor Size AWG or kcmil, Compressed Stranded 500 /Compacted Solid 600 /mmSquared Compact 250/300. With Shrink-Fit Jacket Seal Kit.

655CETPNG0230S

600 Amp, 15kV, Combo T Elbow Reducing Tap Plug without Stud, with Cable Adapter, Lug, No Test Point, Aluminum, Cable Insulation Diameter 0.760 inch to 0.950 inch. Conductor Size AWG or kcmil, Compressed Stranded 500 /Compacted Solid 600 /mmSquared Compact 250/300. With Shrink-Fit Jacket Seal Kit.
600 Amp, 15kV, Combo T Elbow Reducing Tap Plug without Stud, with Cable Adapter, Lug, No Test Point, Aluminum, Cable Insulation Diameter 1.370 inch to 1.630 inch. Conductor Size AWG or kcmil, Compressed Stranded 700/750 /Compacted Solid 900. With Shrink-Fit Jacket Seal Kit.

655CETPNM0380S

600 Amp, 15kV, Combo T Elbow Reducing Tap Plug without Stud, with Cable Adapter, Lug, No Test Point, Aluminum, Cable Insulation Diameter 1.370 inch to 1.630 inch. Conductor Size AWG or kcmil, Compressed Stranded 700/750 /Compacted Solid 900. With Shrink-Fit Jacket Seal Kit.
600 Amp, 15kV, Combo T Elbow Reducing Tap Plug without Stud, with Cable Adapter, Lug, No Test Point, Aluminum, Cable Insulation Diameter 1.515 inch to 1.780 inch. Conductor Size AWG or kcmil, Compressed Stranded 1000. With Shrink-Fit Jacket Seal Kit.

655CETPNN0410S

600 Amp, 15kV, Combo T Elbow Reducing Tap Plug without Stud, with Cable Adapter, Lug, No Test Point, Aluminum, Cable Insulation Diameter 1.515 inch to 1.780 inch. Conductor Size AWG or kcmil, Compressed Stranded 1000. With Shrink-Fit Jacket Seal Kit.

Frequently Asked Questions

What is the maximum operating voltage for the K656LR?

For the 15kV voltage class, the maximum operating voltage is 8.3kV phase-to-ground and 14.4kV phase-to-phase. For the 28kV voltage class, it is 16.2kV phase-to-ground and 28kV phase-to-phase.

What conductor sizes can the K656LR accommodate?

The K656LR can be used with conductor sizes ranging from #2 AWG to 1250 kcmil for both aluminum and copper conductors.

What is the continuous current rating for this elbow connector?

The K656LR elbow connector has a continuous current rating of 600 Amps.

What is the impulse withstand rating for the 28kV voltage class?

The impulse withstand rating for the 28kV voltage class is 140kV BIL (1.2 x 50 microsecond wave).

What is the AC one-minute withstand for the 15kV voltage class?

The AC one-minute withstand for the 15kV voltage class is 34kV.

What is the corona extinction level for the 28kV voltage class?

The corona extinction level for the 28kV voltage class is 21.5kV AC at 3pC sensitivity.

What is the range of insulation diameters the K656LR supports?

The K656LR supports insulation diameters ranging from 0.640 inches to 1.935 inches.

Is a grounding device recommended when using the K656LR?

Yes, when used on metallic tape shield or drain wire cable, an ECS cable seal grounding device for safety is highly recommended.

What accessories are available for the K656LR?

Optional accessories allow for visible external separation, by-pass, isolation, dead-ending, grounding, testing, and adding taps, surge arrestors, and fault current indicators.

What is the momentary current rating for the K656LR?

The momentary current rating is 25kA Sym for 10 Cycles.

How to Install K655/K675LR Deadbreak Elbow Connectors

This guide provides step-by-step instructions for installing 600-ampere or 900-ampere deadbreak elbow connectors on 15kV and 25kV class systems. It covers cable preparation, connector assembly, mating with high voltage apparatus, and grounding procedures. Always ensure all apparatus are de-energized before beginning installation to prevent serious injury.

Estimated time: 1h 30m

Tools needed:

Crimping tool, Wire brush, Hotstick, Suitable sensing device

Supplies needed:

Elbow connector, Cable adapter, Compression lug, Insulating plug (if used), Lubricant, Threaded stud (if mating part not equipped), Wire (at least No. 14 AWG Copper for grounding), Suitable connector (for grounding wire), Tape marker, HV insulated cap(s) or connector(s)

  1. De-energize and Inspect Apparatus

    Before starting, ensure all apparatus are de-energized. Do not touch or move energized products. Inspect all parts for damage, correct rating, and compatibility with mating parts. Remove any protective shipping covers and replace with appropriate HV insulated caps or connectors before energizing or submerging the circuit.

  2. Prepare the Cable for Installation

    Assemble the cable in its final position, allowing enough slack for elbow removal. For concentric neutral cable, unwind the neutral wires. Cut the cable 1-3/4” (45mm) from the centerline of the mating product. Clean the outer surface of the cable for 24” (610mm) or up to the bent back concentric neutral wires. Follow the specific cable preparation steps (A, B, or C) provided in the product documentation for removing the outer jacket and preparing the shield based on your cable type (e.g., Unishield, Jacketed, Non-Jacketed).

  3. Install the Cable Adapter

    Bevel the end of the cable insulation at a 45-degree angle, approximately 1/4” (6mm) back. Thoroughly clean and then lubricate the cable insulation, always working towards the semi-con shield. Install the cable adapter, small end first, until it is flush with the edge of the tape marker.

  4. Prepare the Conductor

    Remove the protruding cable insulation by cutting it even with the end of the cable adapter. Be careful not to cut or nick the cable adapter or the conductor. The exposed conductor length must be between 4-1/4” and 4-9/16” (108mm-116mm). If the length is incorrect, redo the assembly.

  5. Crimp the Compression Lug

    For copper conductors, fully insert the conductor into the compression lug. For aluminum conductors, wire brush the conductor immediately before fully inserting it into the compression lug. Measure the 'Check Dimension' before crimping; it must be less than 6-3/8”. Crimp the compression lug according to the instructions supplied with the lug. After crimping, wipe all excess inhibitor from the lug and cable adapter surface. The distance from the end of the compression lug to the cable adapter must be between 6-3/8” to 7-1/8” (162mm-181mm). If dimensions are incorrect, redo the assembly.

  6. Install the Elbow Connector

    Lubricate the cable adapter and the inside of the elbow cable entrance. Install the elbow onto the cable adapter until it cannot advance further. Verify that the cable adapter remains flush with the tape marker; if not, reposition the cable adapter. Remove the tape marker.

  7. Connect to Mating Products

    WARNING: DO NOT CONNECT OR DISCONNECT MATING PRODUCTS WHILE ENERGIZED. DO NOT ENERGIZE WHILE DISCONNECTED. Remove protective caps from both the elbow and the mating part. If the mating part lacks a stud, hand tighten the threaded stud supplied with the elbow into the mating part. Clean and lubricate both the elbow and the mating part with the supplied lubricant, ensuring surfaces remain clean.

  8. Secure the Elbow to Mating Part

    Push the elbow onto the mating part, carefully aligning the hole in the compression lug with the stud on the mating part.

  9. Connect the Opposite End of the Elbow (if applicable)

    Clean and lubricate the mating part for the opposite end of the elbow. Insert this mating part into the elbow. Engage the threads and hand tighten. Torque the mating part according to its specific instructions. If an insulating plug is used, clean and lubricate the inner surface of the voltage detection cap and place it on the elbow, pushing down firmly until it snaps into place.

  10. Ground the Cable Shield

    Insert one end of a wire (at least No. 14 AWG Copper) through the grounding eye and twist to form a small loop, taking care not to damage the eye. Connect this wire to ground using a suitable connector. The cable shield must be grounded either through a grounding device (following its instructions) or an alternate method. It is also recommended to waterproof the cable jacket at this point to prevent moisture ingress.

  11. Perform Voltage Test (Post-Installation)

    WARNING: The voltage test point is a capacitance device, NOT directly connected to the conductor. Do not use conventional voltage measuring equipment. Use a hotstick to remove the test point cap by peeling it off at an angle. Test with a suitable sensing device, following its manufacturer’s directions, to determine if the cable is energized. Contamination, moisture, or incorrect equipment can give a false 'no voltage' reading. Treat the elbow as energized until the 'no voltage' indication is confirmed by other means to prevent serious or fatal injury. After testing, clean and lubricate the inside surface of the cap with silicone lubricant and replace it on the test point.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.