ABB Installation Products K655LR-K0270-S 15/25kV, 600 Amp, Deadbreak Elbow Connector without Test Point, with Seal kit. Cable…
UPC: 075114341462
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- Rated 15/25kV, 600 Amperes for medium-voltage applications
- Supports cable insulation diameters 1.090–1.310 inches (27.686–33.274mm)
- Aluminum compression lug for stranded/compressed 270–4/0 AWG or solid/compact 250 kcmil conductors
- Deadbreak design enables safe connection/disconnection under load
- Includes seal kit for environmental protection; no test point for simplified installation
Specifications
Amperage Rating | 600 A |
Application | Designed to provide Fully Shielded, Dead-Front Submersible Cable Connections to High-Voltage Apparatus |
Color | Black |
Conductor Range | 4/0 STR/COMPR AWG , 250 kcmil |
Connection Type | Compression Lug |
Current Rating | 600 A |
Environmental Conditions | Fully Submersible |
Insulation | True |
Length | 13 in |
Length | 330.2 mm |
Material | Aluminum |
Material | Housing - EPDM-Rubber |
Series | K655LR |
Size | 1.090 - 1.310 inches (27.686-33.274mm) |
Special Features | Fully shielded, fully submersible molded rubber housing. 100 Percent peroxide-cured construction includes insulation and conductive EPDM materials. Can be easily connected or disconnected using standard hand tools and equipment in a de-energized state. Optional accessories allow visible external separation, by-pass, isolation, dead-ending, grounding, and testing as well as adding taps, surge arrestors, and fault current indicators. With Seal |
Standard | ANSI/IEEE Standard 386 |
Temperature Rating, Maximum | 149 F |
Temperature Rating, Maximum | 65 C |
Temperature Rating, Minimum | -40 F |
Temperature Rating, Minimum | -40 C |
Type | Deadbreak Elbow Connector |
Voltage Rating | 15 to 25 kV |
Voltage Rating | 15/25 kV |
Width | 10.36 in |
Width | 263.144 mm |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 1.0000 L |
Package Weight (Metric) | 0.4540 kg |

756LR-M0270-SG3
35kV 600 Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter). Aluminum Compression Lug. Cable Insulation Diameter 1.370 inch to 1.630 inch. Conductor Size AWG or kcmil, Compressed Stranded 4/0 /Compacted Solid 250 /mmSquared Compact 125. Cold Shrinkable Seal with Copper Braid and Constant Force Spring Included.
756LR-M2330
35kV, 600 Amp, Deadbreak Elbow Connector with Test Point, Cable Insulation Diameter 1.370-1.630 inches (34.798-41.402mm), Copper Lug, Conductor Size 330 - 500kcmil Stranded/Compressed, 600kcmil Solid/Compact. Kit Includes Elbow Connector Housing, Stud, Insulated Plug with Cap, Cable Adapter, V.D. Cap-Peroxide, Tube of Lubricant, Crimp Chart and Installations Instructions. 12.28 x 13.93 inches, 3.37 and 3.83 inch diameters.
K656LR-K0330-SG3
15/25kV, 600 Amp, Deadbreak Elbow Connector without Test Point, with Seal kit. Cable Insulation Diameter 1.090 - 1.310 inches (27.686-33.274mm). Aluminum Compression Lug. Conductor Size 330 - 500 kcmil Stranded/Compressed or 600 kcmil Solid/Compact. SG3 - Cold-Shrinkable Seal with Copper Braid and Constant Force Spring.
K656CETP-H0230
25kv, 600 Amp Series, Deadbreak Combo-T. Connector Elbow with Integral 200 Amp Loadbreak Tap Plug with Test Point. Cable Insulation Diameter 0.850-1.050 inches (21.6-26.7 mm). Aluminum Conductor Material, Conductor Code 230 - #1 Stranded/Compressed or 1/0 Solid/Compact. No Sealing Kit.
K656LR-N2400
15/25kV, Deadbreak Elbow Connector with Test Point, 600 Amps, No Sealing Kit. Cable Insulation Diameter 1.550 to 1.780 inches. Copper Connector. Wire Size 400 - 900 kcmil Stranded/Compressed or 1000 kcmil Solid/Compact. 10.36 inches wide, 13.00 inches from bottom edge to center of bushing insert. 3.38 inch Diameter. Includes Elbow Housing, Lug, Stud, Insulated Plug with Cap, Lubricant Tube, Cable Adapter, Installation Instructions and Crimp Chart.
676CETP-J2320-DRG
Combo-T Integral Separable Connector, 900 Amps, Combo-T Elbow Reducing Tap Plug with Stud, Cable Adapter, Lug and Insulated Cap Kit with Test Point. Cable Adapter Sizing-Cable Insulation Diameter Range .980-1.180 inch ( 24.9-30.0mm), Copper Connector, Connector Size 320 - 450 kcmil Stranded/Compressed, 500 kcmil Solid/Compact. DRG - with Insulated Cap.
655CETPNG0230S
600 Amp, 15kV, Combo T Elbow Reducing Tap Plug without Stud, with Cable Adapter, Lug, No Test Point, Aluminum, Cable Insulation Diameter 0.760 inch to 0.950 inch. Conductor Size AWG or kcmil, Compressed Stranded 500 /Compacted Solid 600 /mmSquared Compact 250/300. With Shrink-Fit Jacket Seal Kit.Frequently Asked Questions
What is the maximum operating voltage for the K655LR-K0270-S?
The K655LR-K0270-S can be used through 28kV, with a maximum phase-to-ground operating voltage of 16.2kV and a maximum phase-to-phase voltage of 28kV.
What conductor sizes can the K655LR-K0270-S accommodate?
It accommodates conductor ranges from #2 AWG to 1250 kcmil for both aluminum and copper conductors.
What is the insulation diameter range for this elbow connector?
The insulation diameters range from 0.640 inches to 1.935 inches.
What standards does the K655LR-K0270-S meet?
It meets ANSI/IEEE Standard 386, Latest Revision.
What is the continuous current rating for this elbow connector?
The continuous current rating is 600 Amps.
What is the momentary current rating for this elbow connector?
The momentary current rating is 25kA Sym for 10 Cycles.
What is the impulse withstand rating for the 28kV voltage class?
The impulse withstand rating is 140kV BIL (1.2 x 50 microsecond wave).
What is the AC one-minute withstand voltage for the 15kV voltage class?
The AC one-minute withstand voltage is 34kV.
What is the AC one-minute withstand voltage for the 28kV voltage class?
The AC one-minute withstand voltage is 45kV.
What is the corona extinction rating for the 15kV voltage class?
The corona extinction rating is 11kV AC at 3pC sensitivity.
How to Install K655/K675LR Deadbreak Elbow Connectors
This guide provides step-by-step instructions for the safe and proper installation of K655/K675LR and 655/675LR deadbreak elbow connectors, including cable preparation, lug crimping, and connection to high voltage apparatus. Ensure all apparatus are de-energized before starting.
Estimated time: 1h 30m
Tools needed:
Cutting tool, Wire strippers, Wire brush, Crimping tool, Torque wrench, Hotstick, Suitable voltage sensing device
Supplies needed:
K655/K675LR Deadbreak Elbow Connector Kit, Cable, Grounding wire (No. 14 AWG Copper or equivalent), Suitable grounding connector, Waterproofing material
- Prepare the Cable for Connection
DANGER: All apparatus must be de-energized during installation. Assemble the cable in its final position with enough slack. For concentric neutral cable, unwind the neutral wires. Cut the cable 1-3/4 inches (45mm) from the centerline of the mating product. Clean the outer surface of the cable for a distance of 24 inches (610mm). Prepare the cable by removing the outer jacket and shield as per documentation for your specific cable type (e.g., Unishield, Jacketed, Non-Jacketed).
- Install Cable Adapter and Compression Lug
Bevel the cable insulation end at a 45-degree angle (approx. 1/4 inch/6mm). Clean and lubricate the insulation, then install the cable adapter, small end first, flush with the tape marker. Cut protruding insulation even with the adapter, ensuring no nicks to the adapter or conductor. Exposed conductor length must be 4-1/4 to 4-9/16 inches (108-116mm). For aluminum, wire brush conductor before fully inserting into the compression lug. Verify 'Check Dimension' is less than 6-3/8 inches before crimping. Crimp the lug per instructions, then wipe excess inhibitor. The distance from lug end to cable adapter must be 6-3/8 to 7-1/8 inches (162-181mm) after crimping.
- Install the Elbow Connector
Lubricate the cable adapter and the inside of the elbow cable entrance. Install the elbow onto the cable adapter until it cannot advance further. Verify the cable adapter is still flush with the tape marker; reposition if necessary. Remove the tape marker. Remove any protective caps from the elbow and the mating part. If the mating part is not equipped with a stud, hand tighten the threaded stud supplied with the elbow into the mating part. Clean and lubricate both the elbow and the mating part with the supplied lubricant, keeping surfaces clean.
- Connect Elbow to Mating Part
WARNING: Do not connect or disconnect mating products while energized. Do not energize while disconnected. Push the elbow onto the mating part, carefully aligning the hole in the compression lug with the stud on the mating part. For the opposite end of the elbow, clean and lubricate the mating part. Insert this mating part into the elbow, engage the threads, and hand tighten. Torque the mating part according to its supplied instructions. If an insulating plug is used as a mating part, clean and lubricate the inner surface of the voltage detection cap and place it on the elbow, pushing down hard until it snaps into place.
- Ground the Cable Shield and Waterproof
Insert one end of a grounding wire (at least No. 14 AWG Copper) through the grounding eye and twist to make a small loop, taking care not to damage the eye. Connect this wire to ground using a suitable connector. The shield of the cable must be grounded; follow instructions supplied with any grounding device, or use an alternate method if no device is used. It is also recommended to waterproof the cable jacket at this point to prevent moisture from entering the cable.
- Perform Voltage Test (Optional but Recommended)
The ELASTIMOLD deadbreak elbow connector has an integral capacitance test point. To use it, remove the test point cap with a hotstick, peeling it off at an angle. WARNING: The voltage test point is a capacitance device, not directly connected to the conductor. Do not use conventional voltage measuring equipment. Use a suitable sensing device designed for capacitive test points to determine if the cable is energized. Contamination or incorrect equipment can give a false 'no voltage' indication; treat the elbow as energized until confirmed by other means. After testing, clean and lubricate the inside surface of the cap with silicone lubricant and replace it on the test point.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.