Authorized ABB Distributor (Installation Products)
ABB - Installation Products K656LR-N2400 - 15/25kV, Deadbreak Elbow Connector with Test Point, 600 Amps, No Sealing Kit. Cable Insulation Diameter 1.550 to 1.780 inches. Copper Connector. Wire Size 400 - 900 kcmil Stranded/Compressed or 1000 kcmil Solid/Compact. 10.36 inches wide, 13.00 inches from bottom edge to center of bushing insert. 3.38 inch Diameter. Includes Elbow Housing, Lug, Stud, Insulated Plug with Cap, Lubricant Tube, Cable Adapter, Installation Instructions and Crimp Chart.

ABB Installation Products K656LR-N2400 15/25kV, Deadbreak Elbow Connector with Test Point, 600 Amps, No Sealing Kit. Cable…

UPC: 075114349116


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB K656LR-N2400 is a 15/25kV deadbreak elbow connector engineered for reliable, fully shielded medium-voltage cable connections in submersible and dead-front applications. This 600-amp unit supports cable insulation diameters from 1.550 to 1.780 inches and accommodates conductor sizes ranging from 400 to 900 kcmil for stranded/compressed conductors or 1000 kcmil for solid/compact conductors. The copper connector ensures optimal conductivity, while the molded rubber housing provides full shielding and submersible durability. The connector is rated for 8.3kV phase-to-ground and 14.4kV phase-to-phase operation at 15kV, with a 95kV BIL impulse withstand rating. For 25kV applications, it supports up to 16.2kV phase-to-ground and 28kV phase-to-phase, with a 140kV BIL rating. The unit delivers 600A continuous current and withstands 25kA symmetrical fault current for 10 cycles. The K656LR-N2400 includes essential installation components: elbow housing, copper compression lug, stud, insulated plug with cap, lubricant tube, cable adapter, installation instructions, and crimp chart. The 10.36-inch width and 13.00-inch depth (to bushing center) with a 3.38-inch diameter ensure compatibility with standard medium-voltage systems. Designed for deadbreak operation, it allows safe connection and disconnection in de-energized states using standard hand tools. Ideal for high-voltage apparatus connections, including transformers, switchgear, and junction boxes in utility, industrial, and commercial power distribution systems.
  • 15/25kV voltage class with 600A continuous current rating
  • Supports cable insulation diameters from 1.550 to 1.780 inches
  • Accommodates 400-900 kcmil stranded/compressed or 1000 kcmil solid/compact copper conductors
  • Non-corrosive capacitive test point for safe voltage verification
  • Includes elbow housing, lug, stud, insulated plug with cap, lubricant, adapter, and instructions

Specifications

Amperage Rating
600 A
Application
15/25kV, 600 Amp Deadbreak Elbow Connection
Color
Black
Conductor Range
900 kcmil , 1000 kcmil
Connection Type
Deadbreak
Current Rating
600 A
Environmental Conditions
Fully Submersible
Insulation
True
Length
13 in
Length
330.2 mm
Material
Copper
Material
Housing - EPDM-Rubber
Series
K656LR
Size
1.550-1.780 inches (cable insulation diameter), 400-900 kcmil (stranded/compressed), 1000 kcmil (solid/compact)
Size
Cable Insulation Diameter 1.550 to 1.780 inches, 3.38 inch Diameter
Special Features
Fully Shielded, Fully Submersible Molded Rubber Housing. 100 percent Peroxide-Cured Construction includes Insulation and Conductive EPDM Materials. Can be Easily Connected or Disconnected using Standard Hand Tools and Equipment in a De-Energized State. Non-Corrosive, Capacitive Test Point
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Deadbreak Elbow Connector with Test Point
Voltage Rating
25 kV
Voltage Rating
15/25 kV
Width
10.36 in
Width
263.144 mm
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
900 Amp, 15/25kV, 600 Series Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Cable Insulation Diameter 1.180 inch to 1.465 inch. Copper Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 900 /Compacted Solid 1000 /mmSquared Compact 500. Cold Shrinkable Seal with Copper Braid and Constant Force Spring Included.

K675LR-L2400-SG3

900 Amp, 15/25kV, 600 Series Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Cable Insulation Diameter 1.180 inch to 1.465 inch. Copper Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 900 /Compacted Solid 1000 /mmSquared Compact 500. Cold Shrinkable Seal with Copper Braid and Constant Force Spring Included.
Copper-coated conductor 1,90m 63A x2

173G0412

Copper-coated conductor 1,90m 63A x2
Solenoid Valve Connectors, Accessory, Thumb screw, Cabled Form A, B, ISB, and FW ISC

V-25TB

Solenoid Valve Connectors, Accessory, Thumb screw, Cabled Form A, B, ISB, and FW ISC
Combo-T Integral Separable Connector, 900 Amps, Combo-T Elbow Reducing Tap Plug with Stud, Cable Adapter, Lug and Insulated Cap Kit with Test Point. Cable Adapter Sizing-Cable Insulation Diameter Range .980-1.180 inch ( 24.9-30.0mm), Copper Connector, Connector Size 320 - 450 kcmil Stranded/Compressed, 500 kcmil Solid/Compact. DRG - with Insulated Cap.

676CETP-J2320-DRG

Combo-T Integral Separable Connector, 900 Amps, Combo-T Elbow Reducing Tap Plug with Stud, Cable Adapter, Lug and Insulated Cap Kit with Test Point. Cable Adapter Sizing-Cable Insulation Diameter Range .980-1.180 inch ( 24.9-30.0mm), Copper Connector, Connector Size 320 - 450 kcmil Stranded/Compressed, 500 kcmil Solid/Compact. DRG - with Insulated Cap.
600 Amp, 15kV, Combo T Elbow Reducing Tap Plug without Stud, with Cable Adapter, Lug, No Test Point, Aluminum, Cable Insulation Diameter 0.760 inch to 0.950 inch. Conductor Size AWG or kcmil, Compressed Stranded 500 /Compacted Solid 600 /mmSquared Compact 250/300. With Shrink-Fit Jacket Seal Kit.

655CETPNG0230S

600 Amp, 15kV, Combo T Elbow Reducing Tap Plug without Stud, with Cable Adapter, Lug, No Test Point, Aluminum, Cable Insulation Diameter 0.760 inch to 0.950 inch. Conductor Size AWG or kcmil, Compressed Stranded 500 /Compacted Solid 600 /mmSquared Compact 250/300. With Shrink-Fit Jacket Seal Kit.
600 Amp, 15kV, Combo T Elbow Reducing Tap Plug without Stud, with Cable Adapter, Lug, No Test Point, Aluminum, Cable Insulation Diameter 1.370 inch to 1.630 inch. Conductor Size AWG or kcmil, Compressed Stranded 700/750 /Compacted Solid 900. With Shrink-Fit Jacket Seal Kit.

655CETPNM0380S

600 Amp, 15kV, Combo T Elbow Reducing Tap Plug without Stud, with Cable Adapter, Lug, No Test Point, Aluminum, Cable Insulation Diameter 1.370 inch to 1.630 inch. Conductor Size AWG or kcmil, Compressed Stranded 700/750 /Compacted Solid 900. With Shrink-Fit Jacket Seal Kit.
600 Amp, 15kV, Combo T Elbow Reducing Tap Plug without Stud, with Cable Adapter, Lug, No Test Point, Aluminum, Cable Insulation Diameter 1.515 inch to 1.780 inch. Conductor Size AWG or kcmil, Compressed Stranded 1000. With Shrink-Fit Jacket Seal Kit.

655CETPNN0410S

600 Amp, 15kV, Combo T Elbow Reducing Tap Plug without Stud, with Cable Adapter, Lug, No Test Point, Aluminum, Cable Insulation Diameter 1.515 inch to 1.780 inch. Conductor Size AWG or kcmil, Compressed Stranded 1000. With Shrink-Fit Jacket Seal Kit.
600 Amp, 15kV, Combo T Elbow Reducing Tap Plug with Stud, Cable Adapter, Lug, No Test Point, Aluminum, Cable Insulation Diameter 1.515 inch to 1.780 inch. Conductor Size AWG or kcmil, Compressed Stranded 1000.

655CETPN0410

600 Amp, 15kV, Combo T Elbow Reducing Tap Plug with Stud, Cable Adapter, Lug, No Test Point, Aluminum, Cable Insulation Diameter 1.515 inch to 1.780 inch. Conductor Size AWG or kcmil, Compressed Stranded 1000.

Frequently Asked Questions

What standards does this elbow connector meet?

The K656LR elbow connector meets ANSI/IEEE Standard 386, Latest Revision.

What is the continuous current rating for this elbow connector?

The K656LR elbow connector has a continuous current rating of 600 Amps.

What is the momentary current rating for this elbow connector?

The K656LR elbow connector can withstand a momentary current rating of 25kA Sym for 10 Cycles.

What is the maximum operating voltage for the 15kV class?

For the 15kV Voltage Class, the maximum phase-to-ground operating voltage is 8.3kV and the maximum phase-to-phase voltage is 14.4kV.

What is the maximum operating voltage for the 28kV class?

For the 28kV Voltage Class, the maximum phase-to-ground operating voltage is 16.2kV and the maximum phase-to-phase voltage is 28kV.

What conductor sizes can this elbow connector accommodate?

It can be used with conductor sizes ranging from #2 AWG to 1250 kcmil for both aluminum and copper conductors.

What is the range of insulation diameters supported by this connector?

The connector supports insulation diameters ranging from 0.640 inches to 1.935 inches.

Is a grounding device recommended for certain cable types?

Yes, when used on metallic tape shield or drain wire cable, an ECS cable seal grounding device is highly recommended for safety.

What is the BIL rating for the 15kV class?

For the 15kV Voltage Class, the BIL (Impulse Withstand) rating is 95kV.

What is the BIL rating for the 28kV class?

For the 28kV Voltage Class, the BIL (Impulse Withstand) rating is 140kV.

How to Install 655/675LR and K655/K675LR Deadbreak Elbow Connectors

This guide provides detailed instructions for the safe installation of Elastimold 655/675LR and K655/K675LR deadbreak elbow connectors. These connectors provide fully shielded, submersible cable connections for high voltage apparatus.

Estimated time: 1h 30m

Tools needed:

Cutting tool, Wire strippers, Wire brush, Crimping tool, Torque wrench, Hotstick, Suitable sensing device, Suitable connector

Supplies needed:

655/675LR or K655/K675LR Deadbreak Elbow Connector Kit (includes Elbow, Cable Adapter, Compression Lug, Insulating Plug, Lubricant, Stud Prepack), High voltage cable (specific type as per application), Grounding wire (No. 14 AWG Copper or equivalent), Silicone lubricant, Tape marker

  1. De-energize Apparatus and Prepare Cable Area

    Ensure all apparatus is de-energized during installation. Assemble the cable in its final position with enough slack. For concentric neutral cable, unwind the neutral wires. Cut the cable 1-3/4” (45mm) from the centerline of the mating product. Clean the outer surface of the cable for 24” (610mm) or up to the bent-back concentric neutral wires.

  2. Prepare Cable End

    Follow the specific cable preparation instructions for your cable type (e.g., non-jacketed, unishield, jacketed, etc.) as detailed in the provided diagrams or referenced instructions for grounding devices/cable shield adapters. Bevel the end of the cable insulation at a 45-degree angle, approximately 1/4” (6mm) back.

  3. Install Cable Adapter

    Thoroughly clean and lubricate the cable insulation, always working towards the semi-con shield. Install the cable adapter, small end first, until it is flush with the edge of the tape marker.

  4. Prepare Conductor

    Remove the protruding cable insulation by cutting it even with the end of the cable adapter. Do not cut or nick the cable adapter or the conductor. Verify the exposed conductor length is between 4-1/4” and 4-9/16” (108mm-116mm); if not, redo the assembly.

  5. Crimp Compression Lug

    For copper conductors, fully insert the conductor into the compression lug. For aluminum conductors, wire brush the conductor immediately before fully inserting it. Measure the 'Check Dimension' before crimping (must be less than 6-3/8”). Crimp the compression lug according to its supplied instructions. Wipe all excess inhibitor from the lug and cable adapter. Verify the distance from the end of the lug to the cable adapter is between 6-3/8” to 7-1/8” (162mm-181mm) after crimping; if not, redo the assembly.

  6. Install Elbow

    Lubricate the cable adapter and the inside of the elbow cable entrance. Install the elbow onto the cable adapter until it cannot advance further. Ensure the cable adapter remains flush with the tape marker; reposition if necessary. Remove the tape marker.

  7. Connect Mating Products

    DO NOT CONNECT OR DISCONNECT MATING PRODUCTS WHILE ENERGIZED. Ensure all deadbreak connectors are de-energized. Remove protective caps from the elbow and the mating part. If the mating part is not equipped with a stud, hand-tighten the threaded stud supplied with the elbow into the mating part. Clean and lubricate both the elbow and the mating part with the supplied lubricant, keeping surfaces clean.

  8. Secure Elbow to Mating Part

    Push the elbow onto the mating part, lining up the hole in the compression lug with the stud on the mating part.

  9. Connect Opposite Mating Part (if applicable)

    Clean and lubricate the mating part for the opposite end of the elbow. Insert this mating part into the elbow. Engage the threads and hand tighten. Torque the mating part according to its specific instructions.

  10. Install Insulating Plug (if used)

    If an insulating plug is used as a mating part, clean and lubricate the inner surface of the voltage detection cap. Place the cap on the elbow and push down hard until it snaps into place.

  11. Ground the Cable Shield

    Insert one end of a grounding wire (at least No. 14 AWG Copper) through the grounding eye and twist to make a small loop, ensuring not to damage the eye. Connect this wire to ground using a suitable connector. The cable shield must be grounded either via a grounding device or an alternate method. It is also recommended to waterproof the cable jacket at this point to prevent moisture ingress.

  12. Perform Voltage Test

    WARNING: THE VOLTAGE TEST POINT IS A CAPACITANCE DEVICE, IT IS NOT DIRECTLY CONNECTED TO THE CONDUCTOR. Remove the test point cap with a hotstick, peeling it off at an angle. Use a suitable sensing device, designed for capacitive test points, to determine if the cable is energized. Do not use conventional voltage measuring equipment. Treat the elbow as energized until the 'no voltage' indication is confirmed by other means to prevent serious or fatal injury. After testing, clean and lubricate the inside surface of the cap with silicone lubricant and replace it on the test point.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.