ABB - Installation Products K655LR-F0240 - 600 Amp, 15/25kV, 600 Series Deadbreak, Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Aluminum Compression Lug. Cable Insulation Diameter 0.640 inch to 0.820 inch. Conductor Size AWG Compressed Stranded 1/0 or Compacted Solid 2/0.

ABB Installation Products K655LR-F0240 600 Amp, 15/25kV, 600 Series Deadbreak, Elbow with Insulated Plug, Cap, Stud, Lug and…

UPC: 783786363971


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call (262) 252-1600 or email [email protected] for pricing and availability.

Overview

The ABB K655LR-F0240 is a robust 600 Amp, 15/25kV 600 Series Deadbreak Elbow designed for reliable power system connections. This component features an insulated plug and cap, ensuring safe and secure operation in medium-voltage applications. The integrated stud and cable adapter facilitate straightforward installation, while the aluminum compression lug provides a durable and efficient electrical connection. Engineered to accommodate cable insulation diameters ranging from 0.640 inches to 0.820 inches, this deadbreak elbow is compatible with conductor sizes of AWG Compressed Stranded 1/0 or Compacted Solid 2/0. The 600 Series designation signifies its adherence to established industry standards for deadbreak connectors, offering proven performance and longevity. This product from ABB Installation Products is essential for utility, industrial, and commercial power distribution networks requiring dependable and safe termination points for medium-voltage cables. Its construction prioritizes electrical integrity and ease of use, making it a practical choice for electricians and system designers. The K655LR-F0240 is a critical component for maintaining the operational continuity and safety of electrical infrastructure. Its specifications are tailored for demanding environments where reliable power delivery is paramount. The aluminum compression lug ensures a low-resistance connection, minimizing power loss and heat generation under load. The deadbreak design allows for safe de-energization and isolation of the cable, a crucial safety feature in high-voltage systems. This elbow connector is a key part of a comprehensive system for managing and distributing electrical power efficiently and securely. Its compatibility with specific conductor and insulation sizes ensures a precise fit, preventing potential issues related to improper termination. The ABB K655LR-F0240 represents a commitment to quality and performance in electrical infrastructure components.
  • 600 Amp current rating for robust power handling
  • 15/25kV voltage rating suitable for medium-voltage systems
  • 600 Series Deadbreak Elbow design for safe connections
  • Accommodates cable insulation diameters from 0.640" to 0.820"
  • Includes insulated plug, cap, stud, cable adapter, and aluminum compression lug

Specifications

Amperage Rating
600 A
Application
Designed to provide Fully Shielded, Dead-Front Submersible Cable Connections to High-Voltage Apparatus
Color
Black
Conductor Range
1/0 STR/COMPR AWG , 2/0 SOL/COMPT AWG
Environmental Conditions
Fully Submersible
Insulation
True
Length
13 in
Length
330.2 mm
Material
Housing - EPDM-Rubber
Special Features
Fully shielded, fully submersible molded rubber housing. 100 Percent peroxide-cured construction includes insulation and conductive EPDM materials. Can be easily connected or disconnected using standard hand tools and equipment in a de-energized state. Optional accessories allow visible external separation, by-pass, isolation, dead-ending, grounding, and testing as well as adding taps, surge arrestors, and fault current indicators
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Deadbreak Elbow Connector
Voltage Rating
15 to 25 kV
Width
10.36 in
Width
263.144 mm
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
6.5100 L
Package Weight (Metric)
2.9530 kg
25kV 200 Amp, Loadbreak Elbow Connector with Test Point, .890 inch - 1.220 Inch Cable Insulation Diameter, Wire Size 1/0 Stranded or 2/0 Solid. Bi-Metal Compression Lug.

262LR-D5240

25kV 200 Amp, Loadbreak Elbow Connector with Test Point, .890 inch - 1.220 Inch Cable Insulation Diameter, Wire Size 1/0 Stranded or 2/0 Solid. Bi-Metal Compression Lug.
6MM2 BLACK CABLE FOR DISTRIBUTION BLOCK ROW TYPE LENGTH 320MM

54211116

6MM2 BLACK CABLE FOR DISTRIBUTION BLOCK ROW TYPE LENGTH 320MM
15/25kV 600 Amp Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter), Aluminum Compression Lug. Cable Insulation Diameter 0.980 inch to 1.180 inch. Conductor Size Compressed/Stranded 4/0 or Compact/Solid 250 or mm2 Compact 125.

K656LR-J0270

15/25kV 600 Amp Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter), Aluminum Compression Lug. Cable Insulation Diameter 0.980 inch to 1.180 inch. Conductor Size Compressed/Stranded 4/0 or Compact/Solid 250 or mm2 Compact 125.
15/25kV 600 Amp Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter), Aluminum Compression Lug. Cable Insulation Diameter 0.980 inch to 1.180 inch. Conductor Size Compressed/Stranded #1 or Compact/Solid 1/0 or mm2 Compact 50. Cold Shrinkable Seal with Copper Braid and Constant Force Spring Included.

K656LR-J0230-SG3

15/25kV 600 Amp Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter), Aluminum Compression Lug. Cable Insulation Diameter 0.980 inch to 1.180 inch. Conductor Size Compressed/Stranded #1 or Compact/Solid 1/0 or mm2 Compact 50. Cold Shrinkable Seal with Copper Braid and Constant Force Spring Included.
15/25kV 600 Amp Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter), Aluminum Compression Lug. Cable Insulation Diameter 1.090 inch to 1.310 inch. Conductor Size Compressed/Stranded 1/0 or Compact/Solid 2/0.

K656LR-K0240

15/25kV 600 Amp Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter), Aluminum Compression Lug. Cable Insulation Diameter 1.090 inch to 1.310 inch. Conductor Size Compressed/Stranded 1/0 or Compact/Solid 2/0.
Elbow Connector with Test Point, 600 Amp, Dead Break, 15/25 KV, Cable Insulation Diameter 1.180 inch to 1.465 inch. Copper Compression Lug. Conductor Size AWG Compressed/Stranded 500 or Solid 600 or mm2 250/300.

K656LR-L2330

Elbow Connector with Test Point, 600 Amp, Dead Break, 15/25 KV, Cable Insulation Diameter 1.180 inch to 1.465 inch. Copper Compression Lug. Conductor Size AWG Compressed/Stranded 500 or Solid 600 or mm2 250/300.
15/25kV 600 Amp Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter), Aluminum Compression Lug. Cable Insulation Diameter 1.180 inch to 1.465 inch. Conductor Size Compressed/Stranded 300 or Compact/Solid 350 or mm2 Compact 150.

K656LR-L0290

15/25kV 600 Amp Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter), Aluminum Compression Lug. Cable Insulation Diameter 1.180 inch to 1.465 inch. Conductor Size Compressed/Stranded 300 or Compact/Solid 350 or mm2 Compact 150.
15/25kV 600 Amp Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter), Aluminum Compression Lug. Cable Insulation Diameter 0.850 inch to 1.050 inch. Conductor Size Compressed/Stranded 500 or Compact/Solid 600 or mm2 Compact 250/300.

K656LR-H0330

15/25kV 600 Amp Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter), Aluminum Compression Lug. Cable Insulation Diameter 0.850 inch to 1.050 inch. Conductor Size Compressed/Stranded 500 or Compact/Solid 600 or mm2 Compact 250/300.

Frequently Asked Questions

What is the voltage rating of the K655LR-F0240 deadbreak elbow?

The ABB K655LR-F0240 deadbreak elbow has a voltage rating of 15/25 kV.

What is the maximum current this deadbreak elbow can handle?

This deadbreak elbow is rated for a maximum current of 600 Amps.

What is the compatible cable insulation diameter range?

The K655LR-F0240 is designed for cable insulation diameters between 0.640 inches and 0.820 inches.

What conductor sizes can be used with this elbow?

It is compatible with AWG Compressed Stranded 1/0 or Compacted Solid 2/0 conductor sizes.

What material is the compression lug made of?

The included lug is an aluminum compression lug.

What series does this deadbreak elbow belong to?

This deadbreak elbow is part of the 600 Series.

How to Install K655/K675LR Deadbreak Elbow Connectors

This guide provides step-by-step instructions for installing 655/675LR and K655/K675LR Deadbreak Elbow Connectors, designed for fully shielded, submersible cable connections to high voltage apparatus on 15kV and 25kV class systems. Ensure all safety precautions are followed.

Estimated time: 2h

Tools needed:

Cable preparation tools, Wire strippers, Crimping tool, Wire brush (for aluminum conductors), Hotstick, Suitable sensing device (for capacitive test points), Torque wrench

Supplies needed:

K655/K675LR Deadbreak Elbow Connector kit (includes Elbow, Cable Adapter, Compression Lug, Insulating Plug, Lubricant, Stud Prepack), Grounding wire (No. 14 AWG Copper or equivalent), Suitable grounding connector, Silicone lubricant, Cleaning wipes/solution

  1. Prepare for Installation and De-energize Apparatus

    DANGER: All apparatus must be de-energized during installation or removal of parts. Do not touch or move energized products. Ensure competent personnel trained in high voltage electrical equipment perform this installation. Inspect all parts for damage, proper rating, and compatibility with mating components. Check package contents for completeness. Have all required tools at hand and maintain cleanliness throughout the procedure.

  2. Prepare the Cable for Connection

    Assemble the cable in its final position, ensuring enough slack for elbow removal. For concentric neutral cable, unwind the neutral wires. Cut the cable 1-3/4 inches (45mm) from the centerline of the mating product. Clean the outer surface of the cable for a distance of 24 inches (610mm) or up to the bent-back concentric neutral wires. Refer to the specific cable preparation diagrams (A, B, or C) in the product documentation for detailed instructions on removing the outer jacket, shield connection, and grounding based on your cable type (e.g., UNISHIELD, jacketed, non-jacketed).

  3. Bevel Cable Insulation and Install Cable Adapter

    Bevel the end of the cable insulation at a 45-degree angle, approximately 1/4 inch (6mm) back. Thoroughly clean and then lubricate the cable insulation, working towards the semi-con shield. Install the cable adapter, small end first, until it is flush with the edge of the tape marker.

  4. Trim Conductor Insulation

    Remove any protruding cable insulation by cutting it even with the end of the cable adapter. Exercise caution not to cut or nick the cable adapter or the conductor. Verify the length of the exposed conductor is between 4-1/4 inches and 4-9/16 inches (108mm-116mm). If the length is incorrect, redo the assembly.

  5. Crimp the Compression Lug

    For copper conductors, fully insert the conductor into the compression lug. For aluminum conductors, wire brush the conductor immediately before fully inserting it into the compression lug. Measure the 'Check Dimension' before crimping; it must be less than 6-3/8 inches. Crimp the compression lug according to the instructions provided with the lug. After crimping, wipe off any excess inhibitor from the compression lug and cable adapter surface. The distance from the end of the compression lug to the cable adapter should be between 6-3/8 inches and 7-1/8 inches (162mm-181mm). If dimensions are incorrect, redo the assembly.

  6. Install the Elbow onto the Cable Adapter

    Lubricate the cable adapter and the inside of the elbow's cable entrance. Install the elbow onto the cable adapter, pushing until it cannot advance further. Confirm that the cable adapter remains flush with the tape marker; reposition if necessary. Remove the tape marker.

  7. Prepare Mating Product and Elbow for Connection

    DANGER: DO NOT CONNECT OR DISCONNECT MATING PRODUCTS WHILE ENERGIZED. DO NOT ENERGIZE WHILE DISCONNECTED. Remove any protective caps from both the elbow and the mating part. If the mating part lacks a stud, hand-tighten the threaded stud supplied with the elbow into the mating part. Clean and lubricate both the elbow and the mating part with the supplied lubricant, ensuring all surfaces remain clean.

  8. Connect Elbow to Mating Product

    Push the elbow onto the mating part, carefully aligning the hole in the compression lug with the stud on the mating part.

  9. Connect Opposite End of Elbow (if applicable)

    If connecting to another mating product on the opposite end of the elbow, clean and lubricate that mating part. Insert the mating part into the elbow, engage the threads, and hand-tighten. Torque the mating part to the specifications provided in its instructions.

  10. Install Insulating Plug (if used)

    If an insulating plug is used as a mating part, clean and lubricate the inner surface of the voltage detection cap. Place the cap onto the elbow and push down firmly until it snaps into place.

  11. Ground the Cable Shield

    Insert one end of a grounding wire (at least No. 14 AWG Copper) through the grounding eye and twist to form a small loop, taking care not to damage the eye. Connect this wire to ground using a suitable connector. The cable shield must be grounded; follow instructions supplied with your grounding device or use an alternate method if no device is used. It is also recommended to waterproof the cable jacket at this point to prevent moisture ingress.

  12. Torque L-Kit Components (if applicable)

    CAUTION: When constructing 600-amp L-Kits, ensure each component is tightened to its specified torque according to the instructions provided with the kit.

  13. Perform Voltage Test

    Remove the test point cap using a hotstick, peeling it off at an angle rather than pulling directly. WARNING: The voltage test point is a capacitance device, not directly connected to the conductor. Do not use conventional voltage measuring equipment. Use a suitable sensing device designed for capacitive test points, following the manufacturer's directions, to determine if the cable is energized. Contamination, moisture, or incorrect equipment can cause a false 'no voltage' indication. Treat the elbow as energized until the 'no voltage' indication is confirmed by other means to prevent serious injury. After testing, clean and lubricate the inside surface of the cap with silicone lubricant and replace it on the test point.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.