Authorized ABB Distributor (Installation Products)
ABB - Installation Products K656LR-L0290 - 15/25kV 600 Amp Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter), Aluminum Compression Lug. Cable Insulation Diameter 1.180 inch to 1.465 inch. Conductor Size Compressed/Stranded 300 or Compact/Solid 350 or mm2 Compact 150.

ABB Installation Products K656LR-L0290 15/25kV 600 Amp Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud…

UPC: 783786431991


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call (262) 252-1600 or email [email protected] for pricing and availability.

Overview

The ABB K656LR-L0290 is a 15/25kV, 600 Amp Series Deadbreak Elbow designed for reliable electrical connections in medium voltage applications. This unit features a built-in test point for safe and accurate voltage verification, enhancing operational safety and maintenance efficiency. The elbow is supplied complete with an insulated plug, cap, stud, lug, and cable adapter, ensuring a comprehensive solution for cable termination. Constructed with an aluminum compression lug, this deadbreak elbow is engineered for secure and durable conductor connections. It accommodates cable insulation diameters ranging from 1.180 inches to 1.465 inches. For conductor sizing, it supports compressed/stranded conductors of 300 kcmil, compact/solid conductors of 350 kcmil, or mm2 compact conductors of 150 mm2. This flexibility in conductor compatibility makes it suitable for a variety of cable types and sizes commonly found in utility, industrial, and commercial power distribution systems. The ABB K656LR-L0290 provides a robust and compliant method for terminating medium voltage cables, ensuring system integrity and operational continuity. Manufacturer: ABB - Installation Products. SKU: K656LR-L0290.
  • 15/25kV voltage rating
  • 600 Amp current rating
  • Integrated test point for safe verification
  • Accommodates cable insulation diameters from 1.180" to 1.465"
  • Aluminum compression lug for secure conductor connection

Specifications

Amperage Rating
600 A
Application
15/25kV, 600 Amp Deadbreak Elbow Connection
Color
Black
Conductor Range
300 kcmil , 350 kcmil
Environmental Conditions
Fully Submersible
Insulation
True
Length
13 in
Length
330.2 mm
Material
Housing - EPDM-Rubber
Special Features
Fully Shielded, Fully Submersible Molded Rubber Housing. 100 percent Peroxide-Cured Construction includes Insulation and Conductive EPDM Materials. Can be Easily Connected or Disconnected using Standard Hand Tools and Equipment in a De-Energized State. Non-Corrosive, Capacitive Test Point
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Deadbreak Elbow Connector with Test Point
Voltage Rating
25 kV
Width
10.36 in
Width
263.144 mm
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
6.6500 L
Package Weight (Metric)
3.0160 kg
600 Amp, 15/25kV, 600 Series Deadbreak, Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Aluminum Compression Lug. Cable Insulation Diameter 1.090 inch to 1.310 inch. Conductor Size kcmil Compressed/Stranded 300 or Compact/Solid 350 or mm2 Compact 150.

K655LR-K0290

600 Amp, 15/25kV, 600 Series Deadbreak, Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Aluminum Compression Lug. Cable Insulation Diameter 1.090 inch to 1.310 inch. Conductor Size kcmil Compressed/Stranded 300 or Compact/Solid 350 or mm2 Compact 150.
6MM2 BLACK CABLE FOR DISTRIBUTION BLOCK ROW TYPE LENGTH 320MM

54211116

6MM2 BLACK CABLE FOR DISTRIBUTION BLOCK ROW TYPE LENGTH 320MM
15/25kV 600 Amp Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter), Aluminum Compression Lug. Cable Insulation Diameter 0.850 inch to 1.050 inch. Conductor Size Compressed/Stranded 500 or Compact/Solid 600 or mm2 Compact 250/300.

K656LR-H0330

15/25kV 600 Amp Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter), Aluminum Compression Lug. Cable Insulation Diameter 0.850 inch to 1.050 inch. Conductor Size Compressed/Stranded 500 or Compact/Solid 600 or mm2 Compact 250/300.
15/25kV 600 Amp Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter), Aluminum Compression Lug. Cable Insulation Diameter 1.090 inch to 1.310 inch. Conductor Size Compressed/Stranded 3/0 or Compact/Solid 4/0 or mm2 Compact 95.

K656LR-K0260

15/25kV 600 Amp Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter), Aluminum Compression Lug. Cable Insulation Diameter 1.090 inch to 1.310 inch. Conductor Size Compressed/Stranded 3/0 or Compact/Solid 4/0 or mm2 Compact 95.
15/25kV 600 Amp Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter), Aluminum Compression Lug. Cable Insulation Diameter 1.180 inch to 1.465 inch. Conductor Size Compressed/Stranded 350 or Compact/Solid 400 or mm2 Compact 185.

K656LR-L0300

15/25kV 600 Amp Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter), Aluminum Compression Lug. Cable Insulation Diameter 1.180 inch to 1.465 inch. Conductor Size Compressed/Stranded 350 or Compact/Solid 400 or mm2 Compact 185.
15/25kV 600 Amp Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter), Aluminum Compression Lug. Cable Insulation Diameter 1.180 inch to 1.465 inch. Conductor Size Compressed/Stranded 450 or Compact/Solid 500/550.

K656LR-L0320

15/25kV 600 Amp Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter), Aluminum Compression Lug. Cable Insulation Diameter 1.180 inch to 1.465 inch. Conductor Size Compressed/Stranded 450 or Compact/Solid 500/550.
15/25kV 600 Amp Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter), Copper Compression Lug. Cable Insulation Diameter 1.180 inch to 1.465 inch. Conductor Size Compressed/Stranded 300 or Compact/Solid 350 or mm2 Compact 150.

K656LR-L2290

15/25kV 600 Amp Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter), Copper Compression Lug. Cable Insulation Diameter 1.180 inch to 1.465 inch. Conductor Size Compressed/Stranded 300 or Compact/Solid 350 or mm2 Compact 150.
15/25kV 600 Amp Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter), Aluminum Compression Lug. Cable Insulation Diameter 0.980 inch to 1.180 inch. Conductor Size Compressed/Stranded #1 or Compact/Solid 1/0 or mm2 Compact 50. Cold-Shrinkable Jacket Seal Included.

K656LR-J0230-S

15/25kV 600 Amp Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter), Aluminum Compression Lug. Cable Insulation Diameter 0.980 inch to 1.180 inch. Conductor Size Compressed/Stranded #1 or Compact/Solid 1/0 or mm2 Compact 50. Cold-Shrinkable Jacket Seal Included.

Frequently Asked Questions

What is the maximum operating voltage for the K656LR elbow connector?

For the 15kV voltage class, the maximum operating voltage is 8.3kV phase-to-ground and 14.4kV phase-to-phase. For the 28kV voltage class, it is 16.2kV phase-to-ground and 28kV phase-to-phase.

What conductor sizes can the K656LR handle?

The K656LR can be used with conductor sizes ranging from #2 AWG to 1250 kcmil for both aluminum and copper conductors.

What is the insulation diameter range for the K656LR?

The K656LR is designed for insulation diameters ranging from 0.640 inches to 1.935 inches.

What is the continuous current rating of the K656LR?

The K656LR has a continuous current rating of 600 Amps.

What is the momentary current rating for the K656LR?

The K656LR has a momentary current rating of 25kA Sym for 10 Cycles.

What is the impulse withstand rating for the K656LR?

For the 15kV class, the impulse withstand is 95kV BIL. For the 28kV class, it is 140kV BIL.

What is the corona extinction rating for the K656LR?

For the 15kV class, the corona extinction is 11kV AC at 3pC sensitivity. For the 28kV class, it is 21.5kV AC at 3pC sensitivity.

What standards does the K656LR meet?

The K656LR meets ANSI/IEEE Standard 386, Latest Revision.

Can the K656LR be installed on de-energized equipment?

Yes, the K656LR can be easily connected or disconnected using standard hand tools and equipment in a de-energized state.

What is the purpose of the test point on the K656LR?

The K656LR features a non-corrosive, capacitive test point for testing purposes.

How to Install Elastimold 655/675LR and K655/K675LR Deadbreak Elbow Connectors

This guide provides detailed instructions for the safe installation, cable preparation, and connection of Elastimold 655/675LR and K655/K675LR Deadbreak Elbow Connectors, ensuring proper high voltage apparatus connections.

Estimated time: 1h 30m

Tools needed:

Cable cutting tool, Cable stripping tool, Beveling tool, Wire brush, Crimping tool, Torque wrench, Hotstick, Suitable voltage sensing device

Supplies needed:

Elbow Connector (655/675LR or K655/K675LR series), Cable Adapter, Compression Lug, Insulating Plug (if required), Lubricant (silicone based), Threaded Stud (prepack), No. 14 AWG Copper wire (or equivalent), Suitable ground connector, Waterproofing material, HV insulated caps, Tape marker, Cleaning supplies

  1. Prepare for Installation and Safety Check

    DANGER: All apparatus must be de-energized during installation or removal of parts. Do not touch or move energized products. Ensure installation is performed by competent personnel trained in high voltage electrical equipment. Inspect all parts for damage, proper rating, and compatibility with mating parts. Check package contents for completeness and ensure all components fit properly with the cable and/or mating products.

  2. Prepare the Cable

    Assemble the cable in its final position with enough slack to allow for elbow removal. For concentric neutral cable, unwind the neutral wires. Cut the cable 1-3/4 inches (45mm) from the centerline of the mating product. Clean the outer surface of the cable for a distance of 24 inches (610mm) or up to the bent back concentric neutral wires. Remove the outer jacket (if applicable) and prepare the cable insulation and semi-con shield according to the specific cable type (e.g., non-jacketed, jacketed, unishield, lead sheath, flat metallic tape shield, fabric tape shield, or longitudinally corrugated shield) and any associated grounding device instructions.

  3. Install Cable Adapter and Prepare Conductor

    Bevel the end of the cable insulation at a 45-degree angle, approximately 1/4 inch (6mm) back. Thoroughly clean and then lubricate the cable insulation, always working toward the semi-con shield. Install the cable adapter, small end first, until it is flush with the edge of the tape marker. Remove the protruding cable insulation by cutting it even with the end of the cable adapter. Do not cut or nick the cable adapter or the conductor. The length of the exposed conductor must be between 4-1/4 inches and 4-9/16 inches (108mm-116mm); otherwise, redo the assembly.

  4. Crimp the Compression Lug

    For copper conductors, fully insert the conductor into the compression lug. For aluminum conductors, wire brush the conductor and immediately fully insert it into the compression lug. Measure the 'Check Dimension' before crimping; it should be less than 6-3/8 inches. Crimp the compression lug following the instructions supplied with the lug. Wipe all excess inhibitor from the compression lug and cable adapter surface after crimping. The distance from the end of the compression lug to the cable adapter after crimping must be between 6-3/8 inches to 7-1/8 inches (162mm-181mm); otherwise, redo the assembly.

  5. Install the Elbow

    Lubricate the cable adapter and the inside of the elbow cable entrance with the supplied lubricant. Install the elbow onto the cable adapter until the elbow cannot advance further. Ensure the cable adapter remains flush with the tape marker. If not, reposition the cable adapter. Remove the tape marker.

  6. Connect to Mating Product

    DANGER: DO NOT CONNECT OR DISCONNECT MATING PRODUCTS WHILE ENERGIZED. DO NOT ENERGIZE WHILE DISCONNECTED. Remove any protective caps from the elbow and the mating part. Hand tighten the threaded stud (supplied with the elbow) into the mating part if it is not already equipped with a stud. Clean and lubricate both the elbow and the mating part with the supplied lubricant, ensuring surfaces remain clean. Push the elbow onto the mating part, carefully lining up the hole in the compression lug with the stud on the mating part.

  7. Connect Opposite End (if applicable)

    If connecting to the opposite end of the elbow, clean and lubricate the mating part for that end. Insert the mating part into the elbow, engage the threads, and hand tighten. Torque the mating part according to the instructions supplied with that specific mating part. CAUTION: When constructing 600amp L-Kits, ensure each component is tightened to the specified torque per provided instructions.

  8. Install Insulating Plug and Ground Cable

    If an insulating plug is used as a mating part, clean and lubricate the inner surface of the voltage detection cap and place it on the elbow. Push down hard until the cap snaps into place. Insert one end of a piece of wire with ampacity at least equivalent to No. 14 AWG Copper through the grounding eye and twist to make a small loop, taking care not to damage the eye. Connect this wire to ground using a suitable connector. The shield of the cable must be grounded according to the instructions supplied with the grounding device, or through an alternate method if no device is used. It is also recommended to waterproof the cable jacket at this point to prevent moisture ingress.

  9. Perform Voltage Test

    To establish if the circuit is energized, remove the test point cap with a hotstick, peeling it off at an angle rather than pulling directly. WARNING: The voltage test point is a capacitance device and is NOT directly connected to the conductor. Do not use conventional voltage measuring equipment. Follow the manufacturer’s directions for the specific meter used. Test with a suitable sensing device designed for separable connectors with capacitive test points. Contamination, moisture, dirt, or incorrect equipment can provide a false 'no voltage' indication on an energized elbow. To prevent serious or fatal injury, treat the elbow as energized until the 'no voltage' test point indication is confirmed by other means. After voltage detection, clean and lubricate the inside surface of the cap with silicone lubricant and replace it on the test point.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.