ABB - Installation Products K656LR-J0270 - 15/25kV 600 Amp Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter), Aluminum Compression Lug. Cable Insulation Diameter 0.980 inch to 1.180 inch. Conductor Size Compressed/Stranded 4/0 or Compact/Solid 250 or mm2 Compact 125.

ABB Installation Products K656LR-J0270 15/25kV 600 Amp Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud…

UPC: 783786366002


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB K656LR-J0270 is a 15/25kV, 600 Amp Series Deadbreak Elbow with an integrated test point, engineered for reliable medium-voltage cable connections in utility, industrial, and commercial power distribution systems. This fully shielded, dead-front elbow connector provides a secure, submersible solution for terminating medium-voltage power cables with insulation diameters ranging from 0.980 inches to 1.180 inches. The unit supports compressed/stranded 4/0 AWG, compact/solid 250 kcmil, or mm² compact 125 conductors, ensuring compatibility with a wide range of cable types. Designed for de-energized connections and disconnections using standard hand tools, the K656LR-J0270 features a non-corrosive, capacitive test point for safe voltage verification without compromising system integrity. The aluminum compression lug ensures a secure conductor attachment, while the included insulated plug, cap, stud, lug, and cable adapter provide a complete termination solution. This deadbreak elbow meets ANSI/IEEE Standard 386 (latest revision) and is rated for continuous operation at 600 Amps, with a maximum phase-to-ground operating voltage of 8.3kV (15kV class) or 16.2kV (25kV class). It delivers a 95kV BIL impulse withstand (1.2 x 50 microsecond wave) and 34kV AC one-minute withstand for 15kV class applications, ensuring robust performance in demanding environments. The 100% peroxide-cured EPDM construction provides exceptional durability, resistance to environmental stress, and long-term reliability. Ideal for applications requiring fully shielded, dead-front submersible connections, the K656LR-J0270 is suitable for utility substations, industrial power distribution, commercial buildings, and renewable energy systems. Its compact design and ease of installation make it a cost-effective choice for maintaining electrical infrastructure integrity while minimizing downtime.
  • 15/25kV voltage class with 600 Amp continuous rating
  • Integrated non-corrosive capacitive test point for safe voltage verification
  • Supports cable insulation diameters from 0.980" to 1.180"
  • Compatible with 4/0 AWG, 250 kcmil, or 125 mm² compact conductors
  • Fully shielded, dead-front submersible design for reliable performance
  • Meets ANSI/IEEE Standard 386 with 95kV BIL impulse withstand
  • Includes insulated plug, cap, stud, lug, and cable adapter for complete termination

Specifications

Amperage Rating
600 A
Application
15/25kV, 600 Amp Deadbreak Elbow Connection
Color
Blue
Color
Black
Conductor Range
4/0 STR/COMPR AWG , 250 kcmil
Connection Type
Compression Lug
Current Rating
600 A
Environmental Conditions
Fully Submersible
Insulation
True
Length
13 in
Length
330.2 mm
Material
Aluminum
Material
Housing - EPDM-Rubber
Series
Deadbreak Elbow
Size
Cable Insulation Diameter 0.980 inch to 1.180 inch
Special Features
Fully Shielded, Fully Submersible Molded Rubber Housing. 100 percent Peroxide-Cured Construction includes Insulation and Conductive EPDM Materials. Can be Easily Connected or Disconnected using Standard Hand Tools and Equipment in a De-Energized State. Non-Corrosive, Capacitive Test Point
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Deadbreak Elbow Connector with Test Point
Voltage Rating
25 kV
Voltage Rating
15/25 kV
Width
10.36 in
Width
263.144 mm
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
6.5500 L
Package Weight (Metric)
2.9710 kg
600 Amp, 35kV, Stick-Op Connector Kit with Test Point, Insulated Cap and Reducing Tap Plug. Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 4/0 /Compacted Solid 250 /mmSquared Compact 125.

755LRTP-L0270-DRG

600 Amp, 35kV, Stick-Op Connector Kit with Test Point, Insulated Cap and Reducing Tap Plug. Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 4/0 /Compacted Solid 250 /mmSquared Compact 125.
Single cable clamp 150-300mm2 for power terminal type 5

45000034

Single cable clamp 150-300mm2 for power terminal type 5
15/25kV 600 Amp Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter), Aluminum Compression Lug. Cable Insulation Diameter 0.980 inch to 1.180 inch. Conductor Size Compressed/Stranded #1 or Compact/Solid 1/0 or mm2 Compact 50. Cold Shrinkable Seal with Copper Braid and Constant Force Spring Included.

K656LR-J0230-SG3

15/25kV 600 Amp Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter), Aluminum Compression Lug. Cable Insulation Diameter 0.980 inch to 1.180 inch. Conductor Size Compressed/Stranded #1 or Compact/Solid 1/0 or mm2 Compact 50. Cold Shrinkable Seal with Copper Braid and Constant Force Spring Included.
15/25kV 600 Amp Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter), Aluminum Compression Lug. Cable Insulation Diameter 1.090 inch to 1.310 inch. Conductor Size Compressed/Stranded 1/0 or Compact/Solid 2/0.

K656LR-K0240

15/25kV 600 Amp Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter), Aluminum Compression Lug. Cable Insulation Diameter 1.090 inch to 1.310 inch. Conductor Size Compressed/Stranded 1/0 or Compact/Solid 2/0.
Elbow Connector with Test Point, 600 Amp, Dead Break, 15/25 KV, Cable Insulation Diameter 1.180 inch to 1.465 inch. Copper Compression Lug. Conductor Size AWG Compressed/Stranded 500 or Solid 600 or mm2 250/300.

K656LR-L2330

Elbow Connector with Test Point, 600 Amp, Dead Break, 15/25 KV, Cable Insulation Diameter 1.180 inch to 1.465 inch. Copper Compression Lug. Conductor Size AWG Compressed/Stranded 500 or Solid 600 or mm2 250/300.
15/25kV 600 Amp Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter), Aluminum Compression Lug. Cable Insulation Diameter 1.180 inch to 1.465 inch. Conductor Size Compressed/Stranded 300 or Compact/Solid 350 or mm2 Compact 150.

K656LR-L0290

15/25kV 600 Amp Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter), Aluminum Compression Lug. Cable Insulation Diameter 1.180 inch to 1.465 inch. Conductor Size Compressed/Stranded 300 or Compact/Solid 350 or mm2 Compact 150.
15/25kV 600 Amp Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter), Aluminum Compression Lug. Cable Insulation Diameter 0.850 inch to 1.050 inch. Conductor Size Compressed/Stranded 500 or Compact/Solid 600 or mm2 Compact 250/300.

K656LR-H0330

15/25kV 600 Amp Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter), Aluminum Compression Lug. Cable Insulation Diameter 0.850 inch to 1.050 inch. Conductor Size Compressed/Stranded 500 or Compact/Solid 600 or mm2 Compact 250/300.
15/25kV 600 Amp Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter), Aluminum Compression Lug. Cable Insulation Diameter 1.090 inch to 1.310 inch. Conductor Size Compressed/Stranded 3/0 or Compact/Solid 4/0 or mm2 Compact 95.

K656LR-K0260

15/25kV 600 Amp Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter), Aluminum Compression Lug. Cable Insulation Diameter 1.090 inch to 1.310 inch. Conductor Size Compressed/Stranded 3/0 or Compact/Solid 4/0 or mm2 Compact 95.

Frequently Asked Questions

What is the voltage rating for the ABB K656LR-J0270?

The ABB K656LR-J0270 has a voltage rating of 15/25kV.

What is the current rating of this deadbreak elbow?

This deadbreak elbow is rated for 600 Amps.

What cable insulation diameters does this elbow support?

The K656LR-J0270 supports cable insulation diameters from 0.980 inches to 1.180 inches.

What conductor sizes can be used with this elbow?

It supports compressed/stranded 4/0 AWG, compact/solid 250 kcmil, or mm2 compact 125 conductors.

Does the ABB K656LR-J0270 include a test point?

Yes, this deadbreak elbow features an integrated test point with an insulated plug.

How to Install Elastimold Deadbreak Elbow Connectors (655/675LR and K655/K675LR)

This guide provides step-by-step instructions for the safe and proper installation of 600-ampere and 900-ampere Elastimold Deadbreak Elbow Connectors on 15kV and 25kV class systems, including cable preparation, lug crimping, and connection to mating apparatus.

Estimated time: 1h 30m

Tools needed:

Crimping tool, Wire brush, Hotstick, Suitable sensing device, Torque wrench, Wire strippers, Knife or utility blade

Supplies needed:

Elbow connector (655/675LR or K655/K675LR), Cable adapter, Compression lug, Insulating plug (if applicable), Lubricant, Threaded stud prepack, Crimp chart, Wire (at least No. 14 AWG Copper), Suitable connector (for grounding wire), HV insulated cap(s) or connector(s), Tape marker

  1. Perform Initial Safety Checks and De-energize Apparatus

    Ensure all apparatus is de-energized before beginning installation or removal of any parts. Do not touch or move energized products in the work area. Verify package contents are complete and undamaged, and all components fit properly with the cable and/or mating products. Have all required tools at hand and maintain cleanliness throughout the procedure. This product must be installed only by competent personnel trained in high voltage electrical safety practices.

  2. Prepare the Cable for Connection

    Assemble the cable in its final position with enough slack for elbow removal. For concentric neutral cable, unwind the neutral wires. Cut the cable 1-3/4” (45mm) from the centerline of the mating product. Clean the outer surface of the cable for 24” (610mm) or up to the bent back concentric neutral wires. Follow specific cable preparation instructions based on cable type (e.g., outer jacket removal, shield connection).

  3. Install the Cable Adapter

    Bevel the end of the cable insulation at a 45-degree angle, approximately 1/4” (6mm) back. Thoroughly clean and lubricate the cable insulation, working towards the semi-con shield. Install the cable adapter, small end first, until it is flush with the edge of the tape marker.

  4. Prepare the Conductor and Crimp the Lug

    Remove protruding cable insulation even with the cable adapter, avoiding nicks to adapter or conductor. Exposed conductor length must be 4-1/4” to 4-9/16” (108mm-116mm). For copper, fully insert conductor into lug. For aluminum, wire brush and immediately insert. Measure 'Check Dimension' before crimping (must be < 6-3/8”). Crimp lug per instructions. Wipe excess inhibitor. Distance from lug end to cable adapter after crimping must be 6-3/8” to 7-1/8” (162mm-181mm).

  5. Install the Elbow Connector

    Lubricate the cable adapter and the inside of the elbow cable entrance. Install the elbow onto the cable adapter until it cannot advance further. Ensure the cable adapter remains flush with the tape marker; reposition if necessary. Remove the tape marker.

  6. Prepare Mating Products and Connect the Elbow

    Remove protective caps from the elbow and mating part. Hand tighten the threaded stud (if needed) into the mating part. Clean and lubricate both the elbow and mating part. Push the elbow onto the mating part, aligning the compression lug hole with the stud. For the opposite end, clean, lubricate, insert, and hand tighten the mating part. Torque mating part per its instructions. DANGER: Do not connect/disconnect or energize while disconnected.

  7. Install Insulating Plug (If Applicable) and Ground the Cable Shield

    If an insulating plug is used as a mating part, clean and lubricate the inner surface of the voltage detection cap and place it on the elbow, pushing until it snaps into place. Insert one end of a No. 14 AWG Copper wire (or equivalent) through the grounding eye, twist to form a small loop, and connect to ground. Ensure the cable shield is grounded. Waterproof the cable jacket to prevent moisture ingress.

  8. Perform Voltage Test

    Use a hotstick to remove the test point cap by peeling at an angle. WARNING: This is a capacitance device, not directly connected to the conductor. Use a suitable sensing device for capacitive test points; do not use conventional voltage measuring equipment. Treat the elbow as energized until 'no voltage' is confirmed by other means. After testing, clean and lubricate the inside surface of the cap with silicone lubricant and replace it.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.