ABB - Installation Products K655DLR-G0240-S - 15/25kV, 600 Amp, Elbow with Direct Test and Sealing Kit. Cable Insulation Diameter - .760-.950 inch, Aluminum Lug, Conductor Size 250 - 1/0 Stranded/Compressed or 2/0 Compact/Solid.

ABB Installation Products K655DLR-G0240-S 15/25kV, 600 Amp, Elbow with Direct Test and Sealing Kit. Cable Insulation Diameter…

UPC: 075114335089


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB K655DLR-G0240-S is a 15/25 kV, 600 Amp deadbreak elbow connector designed for reliable cable terminations. This unit features direct test capabilities, allowing for immediate verification of cable integrity without requiring additional components. The integrated sealing kit ensures a secure and environmentally resistant connection, crucial for maintaining system performance and longevity. Engineered for versatility, the K655DLR series accommodates a cable insulation diameter range of 0.760 to 0.950 inches. The connector is equipped with an aluminum lug, suitable for conductor sizes from 250 kcmil down to 1/0 AWG stranded or compressed, as well as 2/0 AWG compact or solid conductors. This broad compatibility simplifies inventory and installation across various cable types and sizes. Key specifications include: * **Voltage Rating:** 15/25 kV * **Current Rating:** 600 A * **Connection Type:** Deadbreak, Direct Test * **Material:** Aluminum lug * **Cable Insulation Diameter:** 0.760 - 0.950 inches * **Conductor Size Compatibility:** 250 - 1/0 AWG Stranded/Compressed; 2/0 AWG Compact/Solid * **Series:** K655DLR This ABB K655DLR elbow connector, SKU K655DLR-G0240-S, is a critical component for power distribution systems, offering a robust and tested solution for medium-voltage cable terminations. Its design prioritizes ease of installation and dependable electrical performance in utility and industrial applications.
  • 15/25 kV Voltage Rating
  • 600 Amp Current Rating
  • Direct Test Capability
  • Includes Sealing Kit
  • Aluminum Lug for 250-1/0 AWG Conductors

Specifications

Amperage Rating
600 A
Application
15/25kV, 600 Amps, Cable Insulation Diameter - .760-.950 inch
Color
Black
Conductor Range
1/0 STR/COMPR AWG , 2/0 SOL/COMPT AWG
Environmental Conditions
All Weather Conditions, Fully Submersible
Insulation
True
Length
13 in
Length
330.2 mm
Material
Housing - EPDM-Rubber
Special Features
Fully shielded, fully submersible molded rubber housing. 100 Percent peroxide-cured construction includes insulation and conductive EPDM materials. Can be easily connected or disconnected using standard hand tools and equipment in a de-energized state. Optional accessories allow visible external separation, by-pass, isolation, dead-ending, grounding, and testing as well as adding taps, surge arrestors, and fault current indicators. Direct conductor test point equipped elbow
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Deadbreak Direct Test Elbow Connector
Voltage Rating
15 to 25 kV
Width
10.36 in
Width
263.144 mm
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
200 Amp, 15kV, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 0.635 inch to 0.905 inch. Copper Compression Lug. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.

162LR-B-2240

200 Amp, 15kV, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 0.635 inch to 0.905 inch. Copper Compression Lug. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.
15/25kV, 600 Amp, Elbow with Test Point, includes Insulating Plug, Cap, Stud, Lug and Cable Adapter. With Cold Shrinkable Seal with Copper Rod and Constant Force Spring. Cable Insulation Diameter - .760-.950 inch, Bi-Metal Lug, Conductor Size 250 - 2/0 Stranded/Compressed or 3/0 Compact/Solid.

K656LR-G0250-SG2

15/25kV, 600 Amp, Elbow with Test Point, includes Insulating Plug, Cap, Stud, Lug and Cable Adapter. With Cold Shrinkable Seal with Copper Rod and Constant Force Spring. Cable Insulation Diameter - .760-.950 inch, Bi-Metal Lug, Conductor Size 250 - 2/0 Stranded/Compressed or 3/0 Compact/Solid.
200 Amp, 15kV, Loadbreak Replacement Elbow Connector with Test Point, Cable Insulation Diameter 0.850 inch to 1.050 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67. Repair Elbow has extended length contact and elbow housing resulting in a net gain of 8-7/8 inches in length. Includes 00400X long Bi-Metal Contact.

168RLR-H-5270

200 Amp, 15kV, Loadbreak Replacement Elbow Connector with Test Point, Cable Insulation Diameter 0.850 inch to 1.050 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67. Repair Elbow has extended length contact and elbow housing resulting in a net gain of 8-7/8 inches in length. Includes 00400X long Bi-Metal Contact.
25kV, 200 Amps, Loadbreak Elbow, no Sealing Kit, Cable Insulation Diameter 1.090-1.310 inches, (27.69-33.27 mm), Bi-Metal Conductor, Conductor Size 4/0 Stranded/Compressed, 250 Solid/Compact. With Test Point. Kit Contains Elbow Connector Housing, Compression Lug, Probe, Probe Wrench, Lubricant, Installation Instruction Sheet and Crimp Chart. S - Cold Shrinkable Jacket Seal.

262LR-E5270-S

25kV, 200 Amps, Loadbreak Elbow, no Sealing Kit, Cable Insulation Diameter 1.090-1.310 inches, (27.69-33.27 mm), Bi-Metal Conductor, Conductor Size 4/0 Stranded/Compressed, 250 Solid/Compact. With Test Point. Kit Contains Elbow Connector Housing, Compression Lug, Probe, Probe Wrench, Lubricant, Installation Instruction Sheet and Crimp Chart. S - Cold Shrinkable Jacket Seal.
900 Amp, 35kV, 600 Series Elbow with insulated plug, cap, stud, lug and cable adapter. Cable Insulation Diameter 1.090 inch to 1.310 inch. Copper Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 3/0 or Compacted Solid 4/0 or mmSquared Compact 95.

775LR-K2260

900 Amp, 35kV, 600 Series Elbow with insulated plug, cap, stud, lug and cable adapter. Cable Insulation Diameter 1.090 inch to 1.310 inch. Copper Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 3/0 or Compacted Solid 4/0 or mmSquared Compact 95.
200 Amp, 25kV, Loadbreak Replacement Elbow Connector without Test Point, Repair Elbow has extended length contact and elbow housing resulting in a net gain of 8-7/8 inches in length. Includes 00400X long Bi-Metal Contact. Cable Insulation Diameter 0.850 inch to 1.050 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43.

273RLR-H-5250

200 Amp, 25kV, Loadbreak Replacement Elbow Connector without Test Point, Repair Elbow has extended length contact and elbow housing resulting in a net gain of 8-7/8 inches in length. Includes 00400X long Bi-Metal Contact. Cable Insulation Diameter 0.850 inch to 1.050 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43.
200 Amp, 15/25kV, Deadbreak Elbow, Straight Receptacle, Bails are required but not included, order separately. Cable Insulation Diameter 0.890 inch to 1.220 inch. Copper Compression Lug. Conductor Size AWG Compressed Stranded 4/0 or kcmil Solid 250 or mmSquared 126.67.

K151SR-D2270

200 Amp, 15/25kV, Deadbreak Elbow, Straight Receptacle, Bails are required but not included, order separately. Cable Insulation Diameter 0.890 inch to 1.220 inch. Copper Compression Lug. Conductor Size AWG Compressed Stranded 4/0 or kcmil Solid 250 or mmSquared 126.67.
200 Amp, 15/25kV, Deadbreak Elbow, Straight Receptacle, Bails are required but not included, order separately. Cable Insulation Diameter 0.805 inch to 1.060 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded #3 or Solid #2 or mmSquared 26.67.

K151SR-C0210

200 Amp, 15/25kV, Deadbreak Elbow, Straight Receptacle, Bails are required but not included, order separately. Cable Insulation Diameter 0.805 inch to 1.060 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded #3 or Solid #2 or mmSquared 26.67.

Frequently Asked Questions

What is the K655DLR product type?

It is a 15/25kV, 600 Amp Class deadbreak elbow connector that incorporates a direct test system.

What standard does the K655DLR meet?

The K655DLR meets ANSI/IEEE Standard 386, Latest Revision.

What is the BIL for the 28kV voltage class?

For the 28kV voltage class, the Basic Impulse Level (BIL) is 140kV.

What is the BIL for the 15kV voltage class?

For the 15kV voltage class, the Basic Impulse Level (BIL) is 95kV.

What items are included in the K655DLR kit?

The kit includes an elbow connector housing, copper compression lug, stud, insulated plug with cap, lubricant, cable adapter, and installation instructions.

Can the elbow be connected while energized?

No, it can only be connected or disconnected using standard hand tools and equipment in a de-energized state.

What is the momentary current rating?

The momentary current rating for both 15kV and 28kV voltage classes is 25kA Sym for 10 Cycles.

What is the continuous current rating?

The continuous current rating for both 15kV and 28kV voltage classes is 600 Amps.

What are the operating voltages for 28kV class?

For the 28kV class, the maximum phase-to-ground operating voltage is 16.2kV, and phase-to-phase is 28kV.

What are the operating voltages for 15kV class?

For the 15kV class, the maximum phase-to-ground operating voltage is 8.3kV, and phase-to-phase is 14.4kV.

How to Install K655/K675DLR Direct Test Elbow Connectors

A comprehensive guide for the safe and proper installation of K655/K675DLR Direct Test Elbow Connectors, including cable preparation, lug crimping, and connection to high voltage apparatus.

Estimated time: 1h 30m

Tools needed:

Wire strippers, Wire brush (for aluminum conductors), Crimping tool, Torque wrench, Hotstick tool, Screwdriver

Supplies needed:

K655/K675DLR Elbow, Cable Adapter, Compression Lug, Insulating Plug (optional), Lubricant, Stud Prepack, Vinyl plastic tape (if needed), Tape retainer (if needed), Tape marker (if needed), No. 14 AWG copper grounding wire (or equivalent), Suitable grounding connector, Waterproofing material (recommended), Threaded stud (if mating part not equipped)

  1. De-energize and Position Cable

    DANGER: All apparatus must be de-energized during installation or removal of parts to prevent serious or fatal injury. Position the cable in its final assembled location, ensuring enough slack for elbow removal. If using concentric neutral cable, unwind the neutral wires. Cut the cable 1-3/4” (45mm) from the centerline of the mating product.

  2. Clean and Prepare Cable Jacket and Shield

    Clean the outer surface of the cable for a distance of 24” (610mm) or up to the bent back concentric neutral wires. Remove the outer jacket to 12-3/4” (324mm). Fold back shield wires, or remove flat metallic tape shield to 10-3/4” (273mm) and secure with vinyl plastic tape. For fabric tape shield, remove it and install a tape retainer and tape marker to specified dimensions. For longitudinally corrugated shield, remove it and install a tape marker to 10-3/4” (273mm). For semi-con shield, remove it and install a tape marker to dimensions. Do not cut or nick the cable insulation during this process.

  3. Prepare Cable Insulation and Install Adapter

    Bevel the end of the cable insulation at a 45-degree angle, approximately 1/4” (6mm) back. Thoroughly clean the cable insulation, then lubricate it, always working toward the semi-con shield. Install the cable adapter, small end first, until it is flush with the edge of the tape marker.

  4. Expose Conductor and Install Compression Lug

    Remove any protruding cable insulation by cutting it even with the end of the cable adapter. Do not cut or nick the cable adapter or the conductor. Verify the exposed conductor length is between 4-3/8” (111mm) to 4-11/16” (119mm); otherwise, redo the assembly. For copper conductors, fully insert the conductor into the compression lug. For aluminum conductors, wire brush the conductor immediately before fully inserting it. Crimp the compression lug following the instructions supplied with the lug. Wipe all excess inhibitor from the lug and cable adapter surface after crimping. Verify the distance from the end of the compression lug to the cable adapter is between 6-1/2” to 7-1/4” (165mm – 184mm) after crimping.

  5. Install Elbow

    Lubricate the cable adapter and the inside of the elbow cable entrance. Install the elbow onto the cable adapter until it cannot advance further. Ensure the cable adapter remains flush with the tape marker. If not, reposition the cable adapter. Remove the tape marker.

  6. Connect to Mating Product

    DANGER: DO NOT CONNECT OR DISCONNECT MATING PRODUCTS WHILE ENERGIZED. DO NOT ENERGIZE WHILE DISCONNECTED. Remove protective caps from the elbow and the mating part. If the mating part is not equipped with a stud, hand-tighten the threaded stud supplied with the elbow into it. Clean and lubricate both the elbow and the mating part with the supplied lubricant. Push the elbow onto the mating part, carefully lining up the hole in the compression lug with the stud on the mating part.

  7. Secure Opposite End (if applicable) and Ground Cable Shield

    If connecting another mating part to the opposite end of the elbow, clean and lubricate its inner surface, insert it into the elbow, engage the threads, and hand-tighten. Torque the mating part according to its supplied instructions. Ground the cable shield by inserting one end of a No. 14 AWG copper wire (or equivalent) through the grounding eye, twisting it to form a small loop, and connecting it to ground using a suitable connector. Ground the shield according to the instructions supplied with the grounding device, or by an alternate method if no device is used. It is recommended to waterproof the cable jacket at this point to prevent moisture entry.

  8. Install Insulating Plug (Optional)

    If an insulating plug is used as a mating part, clean and lubricate the inner surface of the voltage detection cap. Place the cap on the elbow and push down hard until it snaps into place. Refer to separate instructions for direct voltage testing.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.