ABB - Installation Products 168RLR-H-5270 - 200 Amp, 15kV, Loadbreak Replacement Elbow Connector with Test Point, Cable Insulation Diameter 0.850 inch to 1.050 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67. Repair Elbow has extended length contact and elbow housing resulting in a net gain of 8-7/8 inches in length. Includes 00400X long Bi-Metal Contact.

ABB Installation Products 168RLR-H-5270 200 Amp, 15kV, Loadbreak Replacement Elbow Connector with Test Point, Cable Insulation…

UPC: 075114336192


Documents & Media
BrochureInstallation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB 168RLR-H-5270 Loadbreak Replacement Elbow Connector is engineered for reliable medium voltage applications, specifically designed to address situations where standard elbows are insufficient due to cable length. This fully rated 15kV, 200 Amp Class connector features a lengthened compression lug and housing, providing an extended length of +10-1/2 inches (266.7 mm) compared to standard units. It also facilitates the conversion of live front equipment to dead front configurations without altering the cable. The 168RLR-H-5270 meets ANSI/IEEE Standard 386, Latest Revision, and is designed for connecting to and operating 15kV Class, 95kV BIL apparatus. Key ratings include 8.3kV Max Phase-to-Ground Operating Voltage, 14.4kV Max Phase-to-Phase, 95kV BIL Impulse Withstand, 34kV AC One Minute Withstand, 53kV DC 15 Minutes Withstand, and 11kV AC Corona Extinction @ 3pC sensitivity. It handles 200 Amp Continuous and Loadbreak current and 10kA Sym for 10 Cycles Momentary & Fault Close. The connector boasts a fully shielded, fully submersible molded rubber housing with 100% peroxide-cured insulation, insert, and jacket. It includes provisions for hot stick operation and ground wire connection, ensuring safe and versatile installation. The design accommodates a wide cable range with a minimal number of cable sizes, specifically designed for cable insulation diameters from 0.850 inches to 1.050 inches (21.59 mm to 26.67 mm), identified by the 'H' code. A non-corrosive capacitive test point is integrated for diagnostic purposes. Each kit includes the elbow connector housing, bi-metal compression lug, probe wrench, probe, lubricant, installation instructions, hose clamp, and a crimp chart. SKU: 168RLR-H-5270. Manufacturer: ABB - Installation Products. UNSPSC Code: 39121421.
  • 15kV, 200A Loadbreak Replacement Elbow Connector with extended length housing and lug (+10-1/2 inches)
  • Designed for repairing short cables, connecting new apparatus, or converting live to dead front
  • Accommodates cable insulation diameters from 0.850 to 1.050 inches (H code)
  • Fully shielded, fully submersible molded rubber housing with 100% peroxide-cured insulation
  • Includes non-corrosive capacitive test point, provisions for hot stick and ground wire connection

Specifications

Amperage Rating
200 A
Application
Designed for connecting to and operating 15kV Class, 95kV BIL apparatus
Color
Black
Conductor Range
4/0 STR/COMPR AWG , 250 kcmil
Connection Type
Compression
Connection Type
Elbow Connector
Current Rating
200 A
Environmental Conditions
Fully Submersible
Insulation
True
Material
Housing - EPDM-Rubber
Material
Bi-Metal Lug, Copper
Material
Bi-Metal
Mounting Type
Loadbreak elbow
Series
168RLR
Series
168RLR-H
Size
Cable Insulation Diameter 0.850 inch to 1.050 inch
Size
Cable Insulation Diameter: 0.850-1.050 inch, Conductor Size: AWG 4/0 /Solid 250 /mm² 126.67
Special Features
Fully shielded, fully submersible molded rubber housing. 100 percent peroxide-cured insulation, insert and jacket. Provision for hot stick operation, Provision for ground wire connection. Wide cable range with minimum number of sizes. Extended Length Housing and Compression Lug - plus 10-1/2 inch (266.7mm). Non-Corrosive Capacitive Test Point
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Loadbreak Replacement Elbow Connector with Test Point
Voltage Rating
15 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
200 Amp, 15kV, Loadbreak Elbow Connector, Cable Insulation Diameter 0.890 inch to 1.220 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67. 200ECS Jacket Seal Included.

162LR-D5270-S

200 Amp, 15kV, Loadbreak Elbow Connector, Cable Insulation Diameter 0.890 inch to 1.220 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67. 200ECS Jacket Seal Included.
25kV, 200 Amps, Loadbreak Elbow, no Sealing Kit, Cable Insulation Diameter 1.090-1.310 inches, (27.69-33.27 mm), Bi-Metal Conductor, Conductor Size 4/0 Stranded/Compressed, 250 Solid/Compact. With Test Point. Kit Contains Elbow Connector Housing, Compression Lug, Probe, Probe Wrench, Lubricant, Installation Instruction Sheet and Crimp Chart. S - Cold Shrinkable Jacket Seal.

262LR-E5270-S

25kV, 200 Amps, Loadbreak Elbow, no Sealing Kit, Cable Insulation Diameter 1.090-1.310 inches, (27.69-33.27 mm), Bi-Metal Conductor, Conductor Size 4/0 Stranded/Compressed, 250 Solid/Compact. With Test Point. Kit Contains Elbow Connector Housing, Compression Lug, Probe, Probe Wrench, Lubricant, Installation Instruction Sheet and Crimp Chart. S - Cold Shrinkable Jacket Seal.
900 Amp, 35kV, 600 Series Elbow with insulated plug, cap, stud, lug and cable adapter. Cable Insulation Diameter 1.090 inch to 1.310 inch. Copper Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 3/0 or Compacted Solid 4/0 or mmSquared Compact 95.

775LR-K2260

900 Amp, 35kV, 600 Series Elbow with insulated plug, cap, stud, lug and cable adapter. Cable Insulation Diameter 1.090 inch to 1.310 inch. Copper Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 3/0 or Compacted Solid 4/0 or mmSquared Compact 95.
200 Amp, 25kV, Loadbreak Replacement Elbow Connector without Test Point, Repair Elbow has extended length contact and elbow housing resulting in a net gain of 8-7/8 inches in length. Includes 00400X long Bi-Metal Contact. Cable Insulation Diameter 0.850 inch to 1.050 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43.

273RLR-H-5250

200 Amp, 25kV, Loadbreak Replacement Elbow Connector without Test Point, Repair Elbow has extended length contact and elbow housing resulting in a net gain of 8-7/8 inches in length. Includes 00400X long Bi-Metal Contact. Cable Insulation Diameter 0.850 inch to 1.050 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43.
200 Amp, 15/25kV, Deadbreak Elbow, Straight Receptacle, Bails are required but not included, order separately. Cable Insulation Diameter 0.890 inch to 1.220 inch. Copper Compression Lug. Conductor Size AWG Compressed Stranded 4/0 or kcmil Solid 250 or mmSquared 126.67.

K151SR-D2270

200 Amp, 15/25kV, Deadbreak Elbow, Straight Receptacle, Bails are required but not included, order separately. Cable Insulation Diameter 0.890 inch to 1.220 inch. Copper Compression Lug. Conductor Size AWG Compressed Stranded 4/0 or kcmil Solid 250 or mmSquared 126.67.
200 Amp, 15/25kV, Deadbreak Elbow, Straight Receptacle, Bails are required but not included, order separately. Cable Insulation Diameter 0.805 inch to 1.060 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded #3 or Solid #2 or mmSquared 26.67.

K151SR-C0210

200 Amp, 15/25kV, Deadbreak Elbow, Straight Receptacle, Bails are required but not included, order separately. Cable Insulation Diameter 0.805 inch to 1.060 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded #3 or Solid #2 or mmSquared 26.67.
15/25kV 200 Amp, Deadbreak Straight Plug, Bails are required, but not included, order separately. Cable Insulation Diameter 0.635 inch to 0.905 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded #4/Solid #3/mmSquared 21.14.

K151SP-B0200

15/25kV 200 Amp, Deadbreak Straight Plug, Bails are required, but not included, order separately. Cable Insulation Diameter 0.635 inch to 0.905 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded #4/Solid #3/mmSquared 21.14.
15kV 200 Amp, Loadbreak Repair Elbow Connector with Test Point, Repair Elbow has extended length contact and elbow housing resulting in a net gain of 3-1/4 inches in length. Bi-Metal Contact. Cable Insulation Diameter 0.665 inch to 0.895 inch. Conductor Size 2/0 Stranded/Compressed or 3/0 Compact/Solid

168ELR-6689-5250

15kV 200 Amp, Loadbreak Repair Elbow Connector with Test Point, Repair Elbow has extended length contact and elbow housing resulting in a net gain of 3-1/4 inches in length. Bi-Metal Contact. Cable Insulation Diameter 0.665 inch to 0.895 inch. Conductor Size 2/0 Stranded/Compressed or 3/0 Compact/Solid

Frequently Asked Questions

What type of contact is included with the 168RLR?

The 168RLR replacement elbow includes a long bi-metal contact, catalog number 00400X.

Can the 168RLR be used with a jacket seal?

Yes, the 168RLR is also available with a 200ECS jacket seal included, which is highly recommended.

What is the catalog number for the test point cap?

The test point cap for the 168RLR connector has a catalog number of 156-7.

Where is the 168RLR elbow connector manufactured?

The Elastimold 200 A repair and replacement elbows, including the 168RLR, are designed, molded, and tested in Albuquerque, New Mexico, USA.

Is the 168RLR connector compliant with industry standards?

Yes, the 168RLR connector is IEEE 386 compliant, ANSI certified, and accepted by the Rural Utilities Service (RUS).

Does the 168RLR connector include a test point?

Yes, the 168RLR is a replacement elbow connector that includes a built-in capacitive test point for checking voltage presence.

How much extra length does the 168RLR provide?

The 168RLR replacement elbow provides a net gain of 8 7/8 inches in length due to its extended-length contact and elbow housing.

What is the current rating of this elbow connector?

The Elastimold repair and replacement elbow connectors, including the 168RLR, are rated for 200 A.

What is the voltage class of the 168RLR connector?

The 168RLR replacement elbow connector is designed for a 15 kV voltage class.

What is the voltage class of the 168RLR connector?

The 168RLR replacement elbow connector is designed for a 15 kV voltage class.

How to Install the 168RLR Loadbreak Replacement Elbow Connector

This guide provides step-by-step instructions for installing the 168RLR Loadbreak Replacement Elbow Connector, converting a livefront termination to deadfront for UD cable. It covers cable preparation, lug installation, elbow assembly, grounding, and initial connection.

Estimated time: 1h 30m

Tools needed:

Probe Wrench, Hotstick, Wire brush, Wire strippers, Crimping tool, Voltage sensing device (for capacitive test points)

Supplies needed:

168RLR Elbow Connector Housing, Compression Lug, Probe, Elastimold Lubricant, Hose Clamp, No. 14 AWG (2.5mm) Copper Wire, Grounding Connector

  1. Remove Existing Livefront Termination

    DANGER: All apparatus must be de-energized during installation or removal of parts. Remove the rubber cap from the existing terminator. Cut off the connector at the top of the terminator. Disconnect the ground lead from the base of the terminator. Finally, remove the terminator housing from the cable.

  2. Prepare the Cable

    Train the cable to be straight and in-line with the bushing centerline. Cut the cable to measure exactly 10-1/2 inches from the bushing centerline. Carefully remove 1-3/8 inches of cable insulation from the end, ensuring a square cut and avoiding any nicks to the conductor.

  3. Install Compression Lug

    Wire brush the bare aluminum conductor immediately after preparation. Install the compression lug onto the conductor, rotating it to spread the inhibitor. Position the compression lug so its contact threaded hole aligns with the bushing bore. Crimp the lug according to the crimp chart provided with the lug, starting at the crimp line mark and rotating 180 degrees for each successive crimp. Carefully wipe any excessive inhibitor from the outside of the lug and cable.

  4. Assemble the Elbow Housing

    Lubricate the cable insulation and the inside of the elbow housing with the supplied Elastimold lubricant; do not substitute. Keep the insulation clean and avoid introducing excess grease into the gap between the lug and the insulation. Slide the elbow connector onto the cable using a back-and-forth twisting motion, then wipe off all excess grease. Align the elbow with the compression lug's threaded hole. Hand-thread the probe into the lug, ensuring it turns freely for approximately four turns before becoming snug. Tighten the probe with the probe wrench until the wrench bends.

  5. Connect Concentric Neutral

    Using a separate No. 14 AWG (2.5mm) copper wire or equivalent, insert one end through the grounding eye on the elbow and twist it tight, taking care not to damage the eye. Twist all neutral wires together and connect them to ground using an appropriate connector, ensuring adequate slack in the wires for elbow operation. Add the supplied hose clamp as shown and tighten it snugly, but do not overtighten.

  6. Connect Elbow to Bushing (De-energized)

    DANGER: Lubricate the receptacle portion of the elbow connector and the mating bushing with the supplied lubricant ONLY IF THE TRANSFORMER AND ELBOW ARE KNOWN TO BE DE-ENERGIZED. Securely fasten a hotstick to the loadbreak connector pulling eye. Place the elbow connector receptacle area over the bushing plug, inserting the elbow male contact into the bushing until the first slight resistance is felt. Immediately push the elbow home with a fast, firm, straight motion to engage the internal lock on the elbow and bushing interface, applying sufficient force.

  7. Perform Voltage Test (168RLR Only)

    For 168RLR models, you can perform a voltage test. Remove the test point cap with a hotstick, peeling it off at an angle rather than pulling directly. WARNING: The voltage test point is a capacitance device and is not directly connected to the conductor. Do not use conventional voltage measuring equipment. Use a suitable sensing device made for capacitive test points, following its manufacturer's directions, to determine if the cable is energized. Contamination, moisture, or incorrect equipment can provide a false 'no voltage' indication. Treat the elbow as energized until the 'no voltage' indication is confirmed by other means to prevent serious or fatal injury. After testing, clean and lubricate the inside surface of the cap with silicone grease and replace it on the test point.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.