ABB - Installation Products K151SP-B2250 - 15/25kV 200 Amp, Deadbreak Straight Plug Cable Insulation Diameter 0.635 inch to 0.905 inch. Copper Compression Lug. Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43.

ABB Installation Products K151SP-B2250 15/25kV 200 Amp, Deadbreak Straight Plug Cable Insulation Diameter 0.635 inch to 0.905…

UPC: 783786492138


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

ABB Installation Products K151SP-B2250 is a 15/25 kV, 200 A deadbreak straight plug designed for medium-voltage cable terminations in industrial and utility applications. This deadbreak connector features a copper compression lug for secure, low-resistance connections on stranded 2/0 AWG or solid 3/0 AWG conductors (67.43 mm²), with compatibility for cable insulation diameters ranging from 0.635 inch to 0.905 inch. The deadbreak design eliminates the need for de-energizing the system during installation or maintenance, reducing downtime and improving operational efficiency. This plug is ideal for use in switchgear, transformers, and other medium-voltage equipment where reliable, maintenance-free terminations are critical. The compression lug ensures long-term mechanical and electrical integrity, even under thermal cycling or vibration conditions. Key applications include: - Medium-voltage cable terminations in industrial facilities - Utility substations and distribution systems - Renewable energy installations (solar/wind farms) - Commercial and institutional power distribution The K151SP-B2250 is part of ABB’s K151SP series, a trusted line of deadbreak connectors known for their durability and compliance with industry standards. With a current rating of 200 A and voltage rating of 15/25 kV, this plug meets the demands of modern power systems requiring safe, efficient, and long-lasting cable terminations.
  • Voltage Rating: 15/25 kV
  • Current Rating: 200 A
  • Cable Insulation Diameter: 0.635 inch to 0.905 inch
  • Conductor Size: 2/0 AWG (stranded) or 3/0 AWG (solid), 67.43 mm²
  • Deadbreak design for safe, live-line installation

Specifications

Amperage Rating
200 A
Application
Designed to Terminate UD Cable having Concentric Neutral and Extruded instalation shielding
Color
Black
Conductor Range
2/0 STR/COMPR AWG , 3/0 SOL/COMPT AWG
Environmental Conditions
Fully Shielded, Fully Submersible
Insulation
True
Length
8.81 in
Length
223.774 mm
Material
Housing - EPDM-Rubber
Special Features
Fully shielded, fully submersible molded rubber housing. 100 percent peroxide-cured construction includes insulation and conductive EPDM materials. Provision for ground wire connection. Wide cable range with minimum number of sizes. No Test Point
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Deadbreak Straight Plug
Voltage Rating
15 to 25 kV
Width
2.55 in
Width
64.77 mm
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Capacitive Test Ports, Large Housing, Cable Insulation Diameter 0.635 inch - 0.905 inch / 16-23mm, Aluminum Conductor size 2/0 AWG Stranded/Compressed, 3/0 AWG Solid/Compact.

168FLR3B0250

Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Capacitive Test Ports, Large Housing, Cable Insulation Diameter 0.635 inch - 0.905 inch / 16-23mm, Aluminum Conductor size 2/0 AWG Stranded/Compressed, 3/0 AWG Solid/Compact.
15kV 200 Amp, Loadbreak Repair Elbow Connector with Test Point, Repair Elbow has extended length contact and elbow housing resulting in a net gain of 3-1/4 inches in length. Bi-Metal Contact. Cable Insulation Diameter 0.665 inch to 0.895 inch. Conductor Size AWG Compressed Stranded #3/Solid #2/mmSquared 26.67.

168ELR-6689-5210

15kV 200 Amp, Loadbreak Repair Elbow Connector with Test Point, Repair Elbow has extended length contact and elbow housing resulting in a net gain of 3-1/4 inches in length. Bi-Metal Contact. Cable Insulation Diameter 0.665 inch to 0.895 inch. Conductor Size AWG Compressed Stranded #3/Solid #2/mmSquared 26.67.
600 Amp, 35KV, Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter, Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 300 /Compacted Solid 350 /mmSquared Compact 150.

755LR-L0290

600 Amp, 35KV, Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter, Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 300 /Compacted Solid 350 /mmSquared Compact 150.
15/25kV 200 Amp, Deadbreak Straight Receptacle, Bails are required, but not included, order separately. Cable Insulation Diameter 0.805 inch to 1.060 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67.

K151SR-C0270

15/25kV 200 Amp, Deadbreak Straight Receptacle, Bails are required, but not included, order separately. Cable Insulation Diameter 0.805 inch to 1.060 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67.
15kV 200 Amp, Loadbreak Repair Elbow Connector with Test Point, Repair Elbow has extended length contact and elbow housing resulting in a net gain of 3-1/4 inches in length. Bi-Metal Contact. Cable Insulation Diameter 0.665 inch to 0.895 inch. Conductor Size AWG Compressed Stranded #2 or Solid #1 or mmSquared 33.62.

168ELR-6689-5220

15kV 200 Amp, Loadbreak Repair Elbow Connector with Test Point, Repair Elbow has extended length contact and elbow housing resulting in a net gain of 3-1/4 inches in length. Bi-Metal Contact. Cable Insulation Diameter 0.665 inch to 0.895 inch. Conductor Size AWG Compressed Stranded #2 or Solid #1 or mmSquared 33.62.
200 Amp, 15/25kV, Deadbreak Elbow, Straight Plug, Bails are required but not included, order separately. Cable Insulation Diameter 0.635 inch to 0.905 inch. Includes a copper compression lug. Conductor Size AWG Compressed Stranded #2/Solid #1/mmSquared 33.62.

K151SP-B2220

200 Amp, 15/25kV, Deadbreak Elbow, Straight Plug, Bails are required but not included, order separately. Cable Insulation Diameter 0.635 inch to 0.905 inch. Includes a copper compression lug. Conductor Size AWG Compressed Stranded #2/Solid #1/mmSquared 33.62.
15/25kV 200 Amp, Deadbreak Straight Receptacle (All Copper Lug), Bails are required, but not included, order separately. Cable Insulation Diameter 0.635 inch to 0.905 inch. Conductor Size AWG Compressed Stranded #2/Solid #1/mmSquared 33.62.

K151SR-B2220

15/25kV 200 Amp, Deadbreak Straight Receptacle (All Copper Lug), Bails are required, but not included, order separately. Cable Insulation Diameter 0.635 inch to 0.905 inch. Conductor Size AWG Compressed Stranded #2/Solid #1/mmSquared 33.62.
15/25kV 200 Amp, Deadbreak Straight Plug, Bails are required, but not included, order separately. Cable Insulation Diameter 0.805 inch to 1.060 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded #2/Solid #1/mmSquared 33.62.

K151SP-C0220

15/25kV 200 Amp, Deadbreak Straight Plug, Bails are required, but not included, order separately. Cable Insulation Diameter 0.805 inch to 1.060 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded #2/Solid #1/mmSquared 33.62.

Frequently Asked Questions

What are the voltage ratings for the K151SP?

The K151SP is rated for 15kV and 25kV voltage classes. For 15kV, the maximum phase-to-ground operating voltage is 8.3kV; for 25kV, it is 15.2kV.

What types of cables is the K151SP designed for?

It is designed to terminate UD cable with concentric neutral and extruded insulation shielding. It can also terminate other cable types when installed with the proper Elastimold® cable shield adapter.

What Elastimold products are compatible with the K151SP?

The K151SP is designed to mate with the Elastimold K151T tee splice and the K151SR straight receptacle.

What is the continuous current rating for the K151SP?

The continuous current rating for the K151SP is 200 Amps for both 15kV and 25kV voltage classes.

What cable insulation diameters does the K151SP accommodate?

The K151SP accommodates cable insulation diameters ranging from 0.575 inches to 1.220 inches.

What industry standard does the K151SP meet?

The K151SP meets ANSI/IEEE Standard 386, Latest Revision.

What conductor sizes are compatible with the K151SP?

The K151SP accommodates conductor sizes from No. 4 solid through 4/0 stranded.

What are the voltage ratings for the K151SP?

The K151SP is rated for 15kV and 25kV voltage classes. For 15kV, the maximum phase-to-ground operating voltage is 8.3kV; for 25kV, it is 15.2kV.

What is the continuous current rating for the K151SP?

The continuous current rating for the K151SP is 200 Amps for both 15kV and 25kV voltage classes.

What cable insulation diameters does the K151SP accommodate?

The K151SP accommodates cable insulation diameters ranging from 0.575 inches to 1.220 inches.

How to Install the K151SP Straight Plug

This guide details the installation of the K151SP Straight Plug, covering cable preparation, conductor crimping, and connection to mating Elastimold products for 15kV and 25kV class systems. Ensure all apparatus are de-energized before starting.

Estimated time: 1h 30m

Tools needed:

Cable cutting tool, Wire strippers, Wire brush, Crimping tool, Rag, Approved solvent

Supplies needed:

K151SP Straight Plug, Conductor Contact (female), Nylon Venting Rod, Lubricant (supplied), Cable (solid dielectric type), Mating Elastimold receptacle, ELASTIMOLD bail, Silicone grease, Copper wire (#14 AWG or equivalent), Sealing material, Inhibitor

  1. Prepare Cable Jacket

    De-energize all apparatus. For jacketed concentric neutral cables, cut and remove 8 inches of the cable jacket from the end, ensuring sufficient neutral wires for grounding. For copper tape shield cables, cut and remove 7-1/2 inches of the cable jacket, then remove 6-1/2 inches of the copper tape shield from the cable end. Follow specific instructions for ECS or MA grounding devices if applicable.

  2. Strip Insulation and Clean Conductor

    Remove 7/8 inch to 1 inch of cable insulation and conductive shield, cutting squarely without penciling. For #1 stranded/compressed and #1/0 compressed/solid aluminum cable, remove 1-3/4 inches to 1-7/8 inches. Wire brush bare aluminum conductors immediately and insert them into the crimp barrel containing inhibitor.

  3. Crimp Conductor Contact

    Crimp the socket terminal onto the bared conductor, holding the crimp barrel against the cable insulation. Refer to the crimp chart. Start crimps at the crimp line imprinted on the barrel and rotate each successive crimp 90 degrees. Carefully wipe any excess inhibitor from the contact and cable insulation.

  4. Clean and Pencil Insulation

    Temporarily remove the plastic pin. Remove the semi-conductive shield 7-3/4 inches to 7-13/16 inches back from the end of the socket with a straight, smooth, squared cut; do not cut or nick the insulation. Replace the plastic pin. Pencil the insulation 1/8 inch. Clean the outer jacket and thoroughly clean the insulation with an approved solvent, wiping from the cable end toward the outer jacket. Install an ECS or MA grounding device if applicable.

  5. Lubricate Cable and Plug Housing

    Slide the collar, smaller end first, onto each cable. Keep the cable insulation and plug clean. Apply the supplied lubricant sparingly to the cable as shown and to the inside of the housing. Do not substitute other lubricants, as they may be harmful to the product.

  6. Attach Plug to Cable

    Push the cable into the housing until the leading edge of the socket contact is flush with the front edge of the plug. Remove the plastic pin from the socket and discard it.

  7. Connect to Mating Receptacle

    Lubricate the nose of the plug with silicone grease. Place the nylon rod into the receptacle face until it bottoms (approximately 1-3/4 inches), ensuring the rod is not cut. Insert the plug assembly into the receptacle as far as possible. Pull out the nylon rod. Secure the electrical connection with an ELASTIMOLD bail, referencing the Bailing Instruction Sheet (150TB-4).

  8. Connect System Ground

    If an ELASTIMOLD grounding device is not used, connect a customer-supplied length of #14 AWG (or equivalent) copper wire through the grounding tab and twist tightly. Connect this grounding assembly to the system ground by merging it with the cable shield of each cable. Seal the grounding wires and connections to prevent corrosion.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.