ABB - Installation Products K151SR-A0240 - 200 Amp, 15/25kV, Deadbreak Elbow, Straight Receptacle, Bails are required but not included, order separately. Cable Insulation Diameter 0.575 inch to 0.740 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 1/0 or Solid 2/0 or mmSquared 53.49.

ABB Installation Products K151SR-A0240 200 Amp, 15/25kV, Deadbreak Elbow, Straight Receptacle, Bails are required but not…

UPC: 783786820986


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB K151SR-A0240 is a 200 Amp, 15/25 kV deadbreak elbow designed for straight receptacle connections in medium voltage power distribution systems. This component is engineered for reliable performance and ease of installation within its specified parameters. The K151SR series elbow is compatible with cable insulation diameters ranging from 0.575 inches to 0.740 inches. It utilizes an aluminum compression lug for secure conductor termination, accommodating AWG compressed stranded conductor sizes of 1/0 or solid conductor sizes of 2/0, equivalent to 53.49 mm². This deadbreak elbow is a critical interface for connecting underground distribution cables to equipment such as transformers, switchgear, and other load-break junctions. Its straight receptacle design facilitates straightforward connections in applications where direct inline coupling is required. Bails are a necessary component for proper installation and operation but are not included with this SKU; they must be ordered separately. Key specifications include: * **Voltage Rating:** 15/25 kV (8.3kV Max Phase-to-Ground for 15kV class, 15.2kV Max Phase-to-Ground for 25kV class) * **Current Rating:** 200 A * **Cable Insulation Diameter Range:** 0.575" - 0.740" * **Conductor Size:** AWG Compressed Stranded 1/0, AWG Solid 2/0, or 53.49 mm² * **Connection Type:** Deadbreak Elbow, Straight Receptacle * **Material:** Aluminum (Lug) * **Housing:** Fully shielded, fully submersible molded rubber housing * **Construction:** 100% peroxide-cured construction includes insulation and conductive EPDM materials * **Ground Connection:** Provision for ground wire connection * **Standards:** Meets ANSI/IEEE Standard 386, Latest Revision * **Manufacturer:** ABB - Installation Products * **SKU:** K151SR-A0240 This product is suitable for utility, industrial, and commercial power distribution networks requiring robust and dependable cable terminations. Ensure proper installation procedures are followed, including the separate ordering and installation of required bails, for optimal safety and performance.
  • 200 Amp, 15/25 kV Deadbreak Straight Receptacle Elbow
  • Accommodates cable insulation diameters from 0.575" to 0.740"
  • Supports AWG compressed stranded 1/0 or solid 2/0 conductor sizes (53.49 mm²)
  • Fully shielded, fully submersible molded rubber housing
  • Aluminum compression lug for secure conductor termination

Specifications

Amperage Rating
200 A
Application
Designed to connect a cable to another cable or apparatus
Color
Black
Conductor Range
1/0 STR/COMPR AWG , 2/0 SOL/COMPT AWG
Connection Type
Deadbreak Elbow, Straight Receptacle
Current Rating
200 A
Environmental Conditions
Fully Shielded, Fully Submersible
Insulation
True
Length
9.54 in
Length
242.316 mm
Material
Aluminum
Material
Housing - EPDM-Rubber
Series
K151SR
Special Features
Fully shielded, fully submersible molded rubber housing. 100 percent peroxide-cured construction includes insulation and conductive EPDM materials. Provision for ground wire connection. Wide cable range with minimum number of sizes. No Test Point
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Deadbreak Straight Receptacle
Voltage Rating
15 to 25 kV
Voltage Rating
15/25 kV
Width
2.74 in
Width
69.596 mm
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
25 kV, 200 Amp, Deadbreak, Elbow Connector with Test Point, Cable Insulation Diameter - .635-.905 inch. Bi-Metal Lug, Conductor Size 240 - 1/0 Stranded/Compressed or 2/0 Compact/Solid. Includes Elbow Connector Housing, Compression Lug, Probe, Probe Wrench, Bail Assembly, Tube of Lubricant, Installation Instructions, Crimp Chart and V.D. Cap-Peroxide.

252LR-B5240

25 kV, 200 Amp, Deadbreak, Elbow Connector with Test Point, Cable Insulation Diameter - .635-.905 inch. Bi-Metal Lug, Conductor Size 240 - 1/0 Stranded/Compressed or 2/0 Compact/Solid. Includes Elbow Connector Housing, Compression Lug, Probe, Probe Wrench, Bail Assembly, Tube of Lubricant, Installation Instructions, Crimp Chart and V.D. Cap-Peroxide.
200 Amp, 15kV, Loadbreak Replacement Elbow Connector without Test Point, Cable Insulation Diameter 1.090 inch to 1.310 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49. Repair Elbow has extended length contact and elbow housing resulting in a net gain of 8-7/8 inches in length. Includes 00400X long Bi-Metal Contact.

167RLR-K5240

200 Amp, 15kV, Loadbreak Replacement Elbow Connector without Test Point, Cable Insulation Diameter 1.090 inch to 1.310 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49. Repair Elbow has extended length contact and elbow housing resulting in a net gain of 8-7/8 inches in length. Includes 00400X long Bi-Metal Contact.
200 Amp, 15kV, Loadbreak Replacement Elbow Connector with Test Point, Cable Insulation Diameter 1.090 inch to 1.310 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 3/0 /Solid 4/0 /mmSquared 85.01. Repair Elbow has extended length contact and elbow housing resulting in a net gain of 8-7/8 inches in length. Includes 00400X long Bi-Metal Contact.

168RLR-K-5260

200 Amp, 15kV, Loadbreak Replacement Elbow Connector with Test Point, Cable Insulation Diameter 1.090 inch to 1.310 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 3/0 /Solid 4/0 /mmSquared 85.01. Repair Elbow has extended length contact and elbow housing resulting in a net gain of 8-7/8 inches in length. Includes 00400X long Bi-Metal Contact.
200 Amp, 15/25kV, Deadbreak Elbow, Straight Receptacle, Bails are required but not included, order separately. Cable Insulation Diameter 0.805 inch to 1.060 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 3/0 or Solid 4/0 or mmSquared 85.01.

K151SR-C0260

200 Amp, 15/25kV, Deadbreak Elbow, Straight Receptacle, Bails are required but not included, order separately. Cable Insulation Diameter 0.805 inch to 1.060 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 3/0 or Solid 4/0 or mmSquared 85.01.
200 Amp, 15/25kV, Deadbreak Elbow, Straight Receptacle, Bails are required but not included, order separately. Cable Insulation Diameter 0.575 inch to 0.740 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 2/0 or Solid 3/0 or mmSquared 67.43.

K151SR-A0250

200 Amp, 15/25kV, Deadbreak Elbow, Straight Receptacle, Bails are required but not included, order separately. Cable Insulation Diameter 0.575 inch to 0.740 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 2/0 or Solid 3/0 or mmSquared 67.43.
200 Amp, 35kV, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 1.180 inch to 1.465 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67. 200ECS Jacket Seal Included.

376LR-L-5270-S

200 Amp, 35kV, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 1.180 inch to 1.465 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67. 200ECS Jacket Seal Included.
200 Amp, 15kV, Loadbreak Replacement Elbow Connector without Test Point, Cable Insulation Diameter 0.760 inch to 0.950 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded #1/Solid 1/0 /mmSquared 42.41. Repair Elbow has extended length contact and elbow housing resulting in a net gain of 8-7/8 inches in length. Includes 00400X long Bi-Metal Contact. 200ECS Jacket Seal Included.

167RLR-G5230-S

200 Amp, 15kV, Loadbreak Replacement Elbow Connector without Test Point, Cable Insulation Diameter 0.760 inch to 0.950 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded #1/Solid 1/0 /mmSquared 42.41. Repair Elbow has extended length contact and elbow housing resulting in a net gain of 8-7/8 inches in length. Includes 00400X long Bi-Metal Contact. 200ECS Jacket Seal Included.
200 Amp, 15/25kV, Deadbreak Elbow, Straight Plug, Bails are required but not included, order separately. Cable Insulation Diameter 0.805 inch to 1.060 inch. Copper Compression Lug, Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43.

K151SP-C2250

200 Amp, 15/25kV, Deadbreak Elbow, Straight Plug, Bails are required but not included, order separately. Cable Insulation Diameter 0.805 inch to 1.060 inch. Copper Compression Lug, Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43.

Frequently Asked Questions

Are copper compression lugs suitable for all conductors?

Copper compression lugs are suitable for all copper conductors only.

What are the key features of the K151SR?

The K151SR is a 15/25kV, 200 Amp deadbreak straight receptacle with a fully shielded, submersible molded rubber housing. It features 100% peroxide-cured construction and a provision for ground wire connection.

What is the K151SR Straight Receptacle used for?

The K151SR Straight Receptacle connects a cable to another cable or apparatus. It is suitable for use on both 15 and 25kV systems.

What cable sizes are compatible with the K151SR?

The K151SR accommodates conductor sizes from No. 4 solid through 4/0 stranded. It also fits cable insulation diameters from .575 in through 1.220 in.

What is the continuous current rating?

The continuous current rating for both 15kV and 25kV voltage classes is 200 Amp.

What are the operating voltages for 15kV class?

For the 15kV voltage class, the maximum phase-to-ground operating voltage is 8.3kV, and the maximum phase-to-phase is 14.4kV.

What are the operating voltages for 25kV class?

For the 25kV voltage class, the maximum phase-to-ground operating voltage is 15.2kV, and the maximum phase-to-phase is 26.3kV.

What standards does the K151SR meet?

The K151SR meets ANSI/IEEE Standard 386, Latest Revision.

What items are included in each K151SR kit?

Each kit contains a straight receptacle housing, a receptacle pin connector, a tube of lubricant, installation instructions, and a crimp chart.

What is the range of cable insulation diameters?

The K151SR accommodates cable insulation diameters from 0.575 in to 1.220 in.

How to Install the Elastimold 151SR/K151SR Straight Receptacle

This guide provides detailed instructions for preparing the cable, installing the conductor contact, and assembling the Elastimold 151SR/K151SR Straight Receptacle. All apparatus must be de-energized during installation, and only competent personnel trained in high voltage safety practices should perform this procedure.

Estimated time: 1h

Tools needed:

Cable cutting tool, Cable stripping tool, Wire brush, Crimping tool with appropriate dies, Rag, Approved solvent

Supplies needed:

Elastimold 151SR/K151SR Straight Receptacle kit, Solid dielectric type cable, Silicone grease, Elastimold bail, #14 AWG copper wire (if no grounding device), Sealing material for grounding wires

  1. Prepare the Cable Jacket

    Cut and remove the cable jacket. For jacketed concentric neutral cables, remove 8 inches. For copper tape shield cables, remove 7 1/2 inches of jacket and 6 1/2 inches of copper tape shield from the cable end. Allow sufficient concentric neutral wires for grounding if required.

  2. Prepare Cable Insulation and Conductive Shield

    Remove 7/8 to 1 inch of cable insulation and conductive shield. For #1 stranded/compressed and #1/0 compressed/solid aluminum cable, remove 1 3/4 to 1 7/8 inches. Cut squarely, do not pencil. Wire brush bare aluminum conductors and immediately insert into the crimp barrel containing inhibitor.

  3. Crimp the Conductor Contact

    Crimp the socket terminal onto the bared conductor, ensuring the conductor remains fully seated. Refer to the crimp chart provided with the contact. Start crimps at the imprinted crimp line and rotate each successive crimp or indent 90 degrees. If using aluminum cable, carefully wipe excess inhibitor from the contact and cable insulation.

  4. Prepare Semi-Conductive Shield and Clean Insulation

    Remove the semi-conductive shield to a point 7 9/16 to 7 5/8 inches back from the end of the pin with a straight, smooth, squared cut, ensuring not to nick the insulation. Pencil the insulation 1/8 inch. Clean the outer jacket and thoroughly clean the insulation with an approved solvent, wiping from the cable end toward the outer jacket to remove all semi-conducting residue.

  5. Lubricate Receptacle and Cable

    Remove the protective cap from the straight receptacle, keeping the cable insulation and receptacle clean. Apply the supplied lubricant sparingly to the cable as shown in the instructions and to the inside of the housing. Do not substitute lubricants, as others may harm the product.

  6. Insert Cable into Receptacle Housing

    Push the prepared cable into the receptacle housing until the base of the pin chamfer is flush with the inside face of the receptacle. If the receptacle is not to be immediately connected, replace it with an Elastimold insulating plug (K150DP) as the shipping cover only offers dirt protection and is not an insulating device.

  7. Ground the Cable

    If an Elastimold grounding device is not used, connect a length of #14 AWG (or equivalent) copper wire (customer supplied) through the grounding tab and twist tightly. Connect this grounding assembly to the system ground by merging it with the cable shield of each cable. Seal all grounding wires and connections to prevent corrosion.

  8. Connect to a Mating Plug

    To connect to a mating plug, first lubricate the nose of the plug with silicone grease. Place the nylon rod into the receptacle face until it bottoms (approximately 1 3/4 inches), ensuring it is not cut. Insert the plug assembly into the receptacle as far as possible, then pull out the nylon rod. Secure the electrical connection with an Elastimold bail.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.