Authorized ABB Distributor (Installation Products)
ABB - Installation Products K151SR-A0250 - 200 Amp, 15/25kV, Deadbreak Elbow, Straight Receptacle, Bails are required but not included, order separately. Cable Insulation Diameter 0.575 inch to 0.740 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 2/0 or Solid 3/0 or mmSquared 67.43.

ABB Installation Products K151SR-A0250 200 Amp, 15/25kV, Deadbreak Elbow, Straight Receptacle, Bails are required but not…

UPC: 783786977789


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB K151SR-A0250 is a 200 Amp, 15/25kV Deadbreak Elbow Straight Receptacle designed for reliable electrical connections in medium voltage applications. This receptacle is engineered to accept standard deadbreak elbow connectors, facilitating safe and efficient cable termination. It is crucial to note that bails are required for operation and must be ordered separately. The product is compatible with cable insulation diameters ranging from 0.575 inches to 0.740 inches. For conductor sizing, the receptacle accommodates compressed stranded aluminum conductors of 2/0 AWG, solid aluminum conductors of 3/0 AWG, or equivalent mm² sizes of 67.43. The integrated aluminum compression lug ensures a secure and low-resistance connection to the conductor. This component is suitable for use in power distribution systems where deadbreak technology is employed for enhanced safety and operational flexibility. The UNSPSC code for this product is 39121421. Manufacturer: ABB - Installation Products. SKU: K151SR-A0250.
  • 200 Amp, 15/25kV rating for medium voltage applications
  • Straight receptacle design for deadbreak elbow connectors
  • Accommodates cable insulation diameters from 0.575" to 0.740"
  • Supports 2/0 AWG stranded or 3/0 AWG solid aluminum conductors (67.43 mm²)
  • Includes aluminum compression lug for secure conductor termination

Specifications

Amperage Rating
200 A
Application
Designed to connect a cable to another cable or apparatus
Color
Black
Conductor Range
2/0 STR/COMPR AWG , 3/0 SOL/COMPT AWG
Environmental Conditions
Fully Shielded, Fully Submersible
Insulation
True
Length
9.54 in
Length
242.316 mm
Material
Housing - EPDM-Rubber
Special Features
Fully shielded, fully submersible molded rubber housing. 100 percent peroxide-cured construction includes insulation and conductive EPDM materials. Provision for ground wire connection. Wide cable range with minimum number of sizes. No Test Point
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Deadbreak Straight Receptacle
Voltage Rating
15 to 25 kV
Width
2.74 in
Width
69.596 mm
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Capacitive Test Ports, Large Housing, Cable Insulation Diameter 0.635 inch - 0.905 inch / 16-23mm, Aluminum Conductor size 2/0 AWG Stranded/Compressed, 3/0 AWG Solid/Compact.

168FLR3B0250

Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Capacitive Test Ports, Large Housing, Cable Insulation Diameter 0.635 inch - 0.905 inch / 16-23mm, Aluminum Conductor size 2/0 AWG Stranded/Compressed, 3/0 AWG Solid/Compact.
200 Amp, 35kV, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 1.180 inch to 1.465 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67. 200ECS Jacket Seal Included.

376LR-L-5270-S

200 Amp, 35kV, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 1.180 inch to 1.465 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67. 200ECS Jacket Seal Included.
200 Amp, 15kV, Loadbreak Replacement Elbow Connector without Test Point, Cable Insulation Diameter 0.760 inch to 0.950 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded #1/Solid 1/0 /mmSquared 42.41. Repair Elbow has extended length contact and elbow housing resulting in a net gain of 8-7/8 inches in length. Includes 00400X long Bi-Metal Contact. 200ECS Jacket Seal Included.

167RLR-G5230-S

200 Amp, 15kV, Loadbreak Replacement Elbow Connector without Test Point, Cable Insulation Diameter 0.760 inch to 0.950 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded #1/Solid 1/0 /mmSquared 42.41. Repair Elbow has extended length contact and elbow housing resulting in a net gain of 8-7/8 inches in length. Includes 00400X long Bi-Metal Contact. 200ECS Jacket Seal Included.
200 Amp, 15/25kV, Deadbreak Elbow, Straight Plug, Bails are required but not included, order separately. Cable Insulation Diameter 0.805 inch to 1.060 inch. Copper Compression Lug, Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43.

K151SP-C2250

200 Amp, 15/25kV, Deadbreak Elbow, Straight Plug, Bails are required but not included, order separately. Cable Insulation Diameter 0.805 inch to 1.060 inch. Copper Compression Lug, Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43.
200 Amp, 25kV, Loadbreak Repair Elbow Connector with Test Point, Repair Elbow has extended length contact and elbow housing resulting in a net gain of 3-1/4 inches in length. Includes 02509X long Bi-Metal Contact. Cable Insulation Diameter 0.880 inch to 1.100 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43.

274ELR-88110-5250

200 Amp, 25kV, Loadbreak Repair Elbow Connector with Test Point, Repair Elbow has extended length contact and elbow housing resulting in a net gain of 3-1/4 inches in length. Includes 02509X long Bi-Metal Contact. Cable Insulation Diameter 0.880 inch to 1.100 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43.
Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 17.2kV, Fuse Test Port - Two Capactive Test Ports, Large Housing, Cable Insulation Diameter 0.635 inch - 0.905 inch / 16-23mm, Aluminum Conductor size 1/0 AWG Stranded Compressed, 2/0 AWG Solid Compact

274FLR3-B0240

Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 17.2kV, Fuse Test Port - Two Capactive Test Ports, Large Housing, Cable Insulation Diameter 0.635 inch - 0.905 inch / 16-23mm, Aluminum Conductor size 1/0 AWG Stranded Compressed, 2/0 AWG Solid Compact
Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 17.2kV, Fuse Test Port - Two Capactive Test Ports, Large Housing, Cable Insulation Diameter 0.635 inch - 0.905 inch / 16-23mm, Aluminum Conductor size 2/0 AWG Stranded Compressed, 3/0 AWG Solid Compact

274FLR3-B0250

Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 17.2kV, Fuse Test Port - Two Capactive Test Ports, Large Housing, Cable Insulation Diameter 0.635 inch - 0.905 inch / 16-23mm, Aluminum Conductor size 2/0 AWG Stranded Compressed, 3/0 AWG Solid Compact
Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 17.2kV, Fuse Test Port - Two Capactive Test Ports, Large Housing, Cable Insulation Diameter 0.575 inch - 0.740 inch / 15-19mm, Aluminum Conductor size 2 AWG Stranded Compressed, 1 AWG Solid Compact

274FLR3-A0220

Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 17.2kV, Fuse Test Port - Two Capactive Test Ports, Large Housing, Cable Insulation Diameter 0.575 inch - 0.740 inch / 15-19mm, Aluminum Conductor size 2 AWG Stranded Compressed, 1 AWG Solid Compact

Frequently Asked Questions

What voltage systems is the K151SR suitable for?

The K151SR is suitable for use on both 15kV and 25kV systems.

What is the continuous current rating for the K151SR?

The K151SR has a continuous current rating of 200 Amps for both 15kV and 25kV voltage classes.

What is the maximum operating voltage for 25kV class?

For the 25kV voltage class, the maximum phase-to-ground operating voltage is 15.2kV and phase-to-phase is 26.3kV.

What is the maximum operating voltage for 15kV class?

For the 15kV voltage class, the maximum phase-to-ground operating voltage is 8.3kV and phase-to-phase is 14.4kV.

What standard does the K151SR Deadbreak Receptacle meet?

The K151SR Deadbreak Straight Receptacle meets ANSI/IEEE Standard 386, Latest Revision.

When can the K151SR's disconnect feature be used?

The disconnectible feature of the K151SR can be used only when the circuit is de-energized.

What is the maximum operating voltage for 25kV class?

For the 25kV voltage class, the maximum phase-to-ground operating voltage is 15.2kV and phase-to-phase is 26.3kV.

What standard does the K151SR Deadbreak Receptacle meet?

The K151SR Deadbreak Straight Receptacle meets ANSI/IEEE Standard 386, Latest Revision.

What is the maximum operating voltage for 15kV class?

For the 15kV voltage class, the maximum phase-to-ground operating voltage is 8.3kV and phase-to-phase is 14.4kV.

When can the K151SR's disconnect feature be used?

The disconnectible feature of the K151SR can be used only when the circuit is de-energized.

How to Install the 151SR/K151SR Straight Receptacle

This guide provides step-by-step instructions for the installation, cable preparation, and connection of the Elastimold 151SR/K151SR Straight Receptacle for 15kV or 25kV class systems. Ensure all apparatus is de-energized before starting.

Estimated time: 1h

Tools needed:

Wire strippers/knife, Wire brush, Crimp tool, Approved solvent, Clean rag

Supplies needed:

Conductor Contact (male), Nylon Venting Rod, Lubricant (supplied with kit), Crimp Chart, #14 AWG copper wire (customer supplied), Silicone grease, Sealing material for grounding wires

  1. Prepare for Installation and Safety

    Before beginning, ensure all apparatus is de-energized. Inspect all parts for damage, proper rating, and compatibility with mating products. Gather all required tools and supplies, and maintain cleanliness throughout the procedure. This product should only be installed by competent personnel trained in high voltage electrical equipment safety practices.

  2. Prepare Cable Jacket and Shield

    For jacketed concentric neutral cables, cut and remove the cable jacket 8 inches from the cable end, allowing sufficient neutral wires for grounding. For copper tape shield cables, cut and remove the cable jacket 7 1/2 inches from the cable end, then remove the copper tape shield 6 1/2 inches from the cable end. Refer to specific grounding device instructions if using an ECS or MA device.

  3. Prepare Cable Insulation and Conductor

    Remove 7/8 inch to 1 inch of cable insulation and conductive shield. For #1 stranded/compressed and #1/0 compressed/solid aluminum cable, remove 1 3/4 inches to 1 7/8 inches. Cut the cable squarely; do not pencil the cut. Wire brush bare aluminum conductors immediately before inserting them into the crimp barrel, which contains an inhibitor.

  4. Crimp Conductor Contact

    Crimp the socket terminal onto the bared conductor, ensuring the conductor remains fully seated in the connector. Start the crimps at the crimp line imprinted on the crimp barrel and rotate each successive crimp or indent 90 degrees. If using aluminum cable, carefully wipe any excess inhibitor from the contact and cable insulation.

  5. Prepare Semi-Conductive Shield and Clean Insulation

    Remove the semi-conductive shield to a point 7 9/16 inches to 7 5/8 inches back from the end of the pin with a straight, smooth, 'squared' cut. Do not cut or nick the insulation. Pencil the insulation 1/8 inch. Thoroughly clean the outer jacket and insulation to remove all traces of semi-conducting residue by wiping with a rag wet with an approved solvent, always wiping from the end of the cable toward the outer jacket.

  6. Lubricate Receptacle and Insert Cable

    Remove the protective cap from the straight receptacle, keeping the cable insulation and receptacle clean. Apply the supplied lubricant sparingly to the cable as shown and to the inside of the housing. Do not substitute lubricants. Push the cable into the housing until the base of the pin chamfer is flush with the inside face of the receptacle. If not immediately connecting, replace with an appropriate insulating plug (e.g., K150DP), as the shipping cover is for dirt protection only.

  7. Connect to Mating Plug

    Lubricate the nose of the mating plug with silicone grease. Place the nylon rod into the receptacle face until it bottoms (approximately 1 3/4 inches), ensuring the rod is not cut during mating. Insert the plug assembly into the receptacle as far as possible. Pull out the nylon rod. Secure the electrical connection with the aid of an Elastimold bail. A bailing arrangement is required when this product is used with any mating Elastimold deadbreak product.

  8. Ground the Cable

    If an ELASTIMOLD grounding device is not being used, connect a length of #14 AWG (or equivalent) copper wire (customer supplied) through the grounding tab and twist tightly. Connect the grounding assembly of the connector to the system ground by merging with the cable shield of each cable. Seal the grounding wires and connections to prevent corrosion.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.