ABB - Installation Products K151SP-C0220 - 15/25kV 200 Amp, Deadbreak Straight Plug, Bails are required, but not included, order separately. Cable Insulation Diameter 0.805 inch to 1.060 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded #2/Solid #1/mmSquared 33.62.

ABB Installation Products K151SP-C0220 15/25kV 200 Amp, Deadbreak Straight Plug, Bails are required, but not included, order…

UPC: 783786503599


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB K151SP-C0220 is a 15/25kV, 200 Amp deadbreak straight plug engineered for reliable medium-voltage cable terminations in industrial and utility applications. This deadbreak connector features a fully shielded, fully submersible molded rubber housing with 100% peroxide-cured EPDM insulation and conductive materials for long-term durability and environmental resistance. The plug accommodates cable insulation diameters from 0.805 inches to 1.060 inches and supports conductor sizes from AWG #2 stranded to #1 solid (33.62 mm²), making it compatible with a wide range of medium-voltage cables. Its aluminum compression lug ensures secure conductor termination, while the provision for ground wire connection enhances safety and system integrity. The K151SP-C0220 meets ANSI/IEEE Standard 386 for 15kV and 25kV voltage classes, offering robust performance with 200 Amp continuous current rating, 95kV BIL impulse withstand, and 10kA symmetrical momentary rating. Designed for use with UD cables featuring concentric neutral and extruded insulation shielding, this plug can also terminate other cable types when paired with the appropriate Elastimold® cable shield adapter. It is intended for mating with Elastimold® products such as the K151T tee splice and K151SR straight receptacle, providing versatile connectivity in medium-voltage distribution systems. Note: Bails are required for proper installation and must be ordered separately.
  • 15/25kV voltage rating with 200 Amp continuous current capacity
  • Accommodates cable insulation diameters from 0.805" to 1.060"
  • Supports AWG #2 stranded or #1 solid conductors (33.62 mm²)
  • Fully shielded, submersible molded rubber housing with EPDM materials
  • Meets ANSI/IEEE Standard 386 for medium-voltage applications

Specifications

Amperage Rating
200 A
Application
Designed to Terminate UD Cable having Concentric Neutral and Extruded instalation shielding
Color
Black
Conductor Range
#2 STR/COMPR AWG , #1 SOL/COMPT AWG
Connection Type
Deadbreak Straight Plug
Current Rating
200 A
Environmental Conditions
Fully Shielded, Fully Submersible
Insulation
True
Length
8.81 IN
Material
Housing - EPDM-Rubber
Material
Aluminum
Series
K151SP
Size
0.805 inch to 1.060 inch
Special Features
Fully shielded, fully submersible molded rubber housing. 100 percent peroxide-cured construction includes insulation and conductive EPDM materials. Provision for ground wire connection. Wide cable range with minimum number of sizes. No Test Point
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Deadbreak Straight Plug
Voltage Rating
15/25 kV
Voltage Rating
15 to 25 kV
Width
2.55 IN
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
Elbow, 600 Amp, Deadbreak, 15/25KV, Cable Insulation Diameter 0.640 inch to 0.820 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded #2/Solid #1/mmSquared 33.62.

655LR-F0220

Elbow, 600 Amp, Deadbreak, 15/25KV, Cable Insulation Diameter 0.640 inch to 0.820 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded #2/Solid #1/mmSquared 33.62.
Single cable clamp 150-300mm2 for power terminal type 5

45000034

Single cable clamp 150-300mm2 for power terminal type 5
15/25kV 200 Amp, Deadbreak Straight Plug, Bails are required, but not included, order separately. Cable Insulation Diameter 0.805 inch to 1.060 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67.

K151SP-C0270

15/25kV 200 Amp, Deadbreak Straight Plug, Bails are required, but not included, order separately. Cable Insulation Diameter 0.805 inch to 1.060 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67.
15/25kV 200 Amp, Deadbreak Straight Receptacle, Bails are required, but not included, order separately. Cable Insulation Diameter 0.805 inch to 1.060 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43.

K151SR-C0250

15/25kV 200 Amp, Deadbreak Straight Receptacle, Bails are required, but not included, order separately. Cable Insulation Diameter 0.805 inch to 1.060 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43.
200 Amp, 15kV, Loadbreak Direct Test Elbow Connector, Cable Insulation Diameter 0.850 inch to 1.050 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 4/0 or Solid 250 or mmSquared 26.67.

167DLR-H5270

200 Amp, 15kV, Loadbreak Direct Test Elbow Connector, Cable Insulation Diameter 0.850 inch to 1.050 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 4/0 or Solid 250 or mmSquared 26.67.
200 Amp, 15/25kV, Deadbreak Elbow, Straight Plug, Bails are required but not included, order separately. Cable Insulation Diameter 0.805 inch to 1.060 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43.

K151SP-C0250

200 Amp, 15/25kV, Deadbreak Elbow, Straight Plug, Bails are required but not included, order separately. Cable Insulation Diameter 0.805 inch to 1.060 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43.
200 Amp, 15/25kV, Deadbreak Elbow, Straight Receptacle, Bails are required but not included, order separately. Cable Insulation Diameter 0.805 inch to 1.060 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded #1 or Solid 1/0 or mmSquared 42.41.

K151SR-C0230

200 Amp, 15/25kV, Deadbreak Elbow, Straight Receptacle, Bails are required but not included, order separately. Cable Insulation Diameter 0.805 inch to 1.060 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded #1 or Solid 1/0 or mmSquared 42.41.
200 Amp, 15/25kV, Deadbreak Elbow, Straight Plug, Bails are required but not included, order separately. Cable Insulation Diameter 0.805 inch to 1.060 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded #1/Solid 1/0 /mmSquared 42.41.

K151SP-C0230

200 Amp, 15/25kV, Deadbreak Elbow, Straight Plug, Bails are required but not included, order separately. Cable Insulation Diameter 0.805 inch to 1.060 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded #1/Solid 1/0 /mmSquared 42.41.

Frequently Asked Questions

What is the continuous current rating for the K151SP?

The K151SP has a continuous current rating of 200 Amps for both 15kV and 25kV voltage classes.

What are the 25kV operating voltage ratings for the K151SP?

For the 25kV class, the maximum phase-to-ground operating voltage is 15.2kV, and the maximum phase-to-phase is 26.3kV.

What are the 15kV operating voltage ratings for the K151SP?

For the 15kV class, the maximum phase-to-ground operating voltage is 8.3kV, and the maximum phase-to-phase is 14.4kV.

Which Elastimold products are compatible with the K151SP?

The K151SP is designed to mate with the Elastimold K151T tee splice and the K151SR straight receptacle.

What cable insulation diameters are supported by the K151SP?

The K151SP supports cable insulation diameters ranging from .575 inches to 1.220 inches.

What conductor sizes does the K151SP accommodate?

The K151SP accommodates conductor sizes from No. 4 solid through 4/0 stranded.

What types of cables can the K151SP terminate?

It is designed to terminate UD cable with concentric neutral and extruded insulation shielding. It can also terminate other cable types when installed with the proper Elastimold® cable shield adapter.

What are the main features of the K151SP plug?

The K151SP is a 15/25kV, 200 Amp deadbreak straight plug with a fully shielded, submersible molded rubber housing and a provision for ground wire connection. It features 100% peroxide-cured construction.

What conductor sizes does the K151SP accommodate?

The K151SP accommodates conductor sizes from No. 4 solid through 4/0 stranded.

Which Elastimold products are compatible with the K151SP?

The K151SP is designed to mate with the Elastimold K151T tee splice and the K151SR straight receptacle.

How to Install the K151SP Straight Plug

This guide provides step-by-step instructions for preparing cables, crimping the conductor contact, and installing the K151SP Straight Plug onto solid dielectric type cables for 15kV and 25kV class systems.

Estimated time: 1h

Tools needed:

Cable cutting tool, Measuring tape or ruler, Wire brush, Crimp tool (refer to crimp chart), Rag

Supplies needed:

K151SP Straight Plug (includes Conductor Contact, Nylon Venting Rod, Lubricant), Approved solvent, Silicone grease, #14 AWG copper wire (customer supplied), Sealing material (for grounding wires), ELASTIMOLD bail (required for mating deadbreak products), Solid dielectric type cable

  1. Ensure Safety and Inspect Components

    Before beginning, ensure all apparatus are de-energized to prevent serious injury or fatality. Inspect all K151SP components for damage, proper rating, and compatibility with mating parts. Confirm all required tools and supplies are at hand and maintain a clean work area throughout the procedure. This product must only be installed by competent personnel trained in high voltage electrical equipment safety practices.

  2. Prepare Cable Jacket and Shield

    For jacketed concentric neutral cable, cut and remove the cable jacket 8 inches from the cable end, ensuring sufficient concentric neutral wires for grounding. For copper tape shield cable, cut and remove the cable jacket 7-1/2 inches from the cable end, then remove the copper tape shield 6-1/2 inches from the cable end. If using an ECS or MA grounding device, refer to its specific instructions for outer jacket cut back.

  3. Prepare Cable Insulation and Conductor

    Remove 7/8 inch to 1 inch of cable insulation and conductive shield, cutting squarely without penciling. For #1 stranded/compressed and #1/0 compressed/solid aluminum cable, remove 1-3/4 inches to 1-7/8 inches. Wire brush bare aluminum conductors immediately and insert them into the crimp barrel, which contains inhibitor.

  4. Crimp the Conductor Socket Terminal

    Crimp the socket terminal onto the bared conductor, holding the crimp barrel firmly against the cable insulation. Refer to the crimp chart provided with the contact. Begin crimping at the crimp line imprinted on the barrel, rotating each successive crimp or indent 90 degrees. Carefully wipe any excess inhibitor from the contact and cable insulation.

  5. Finish Semi-Conductive Shield and Clean Insulation

    Temporarily remove the plastic pin. Remove the semi-conductive shield 7-3/4 inches to 7-13/16 inches back from the end of the socket with a straight, smooth, squared cut, taking care not to cut or nick the insulation. Replace the plastic pin. Pencil the insulation 1/8 inch. Thoroughly clean the outer jacket and insulation with an approved solvent, wiping from the cable end toward the outer jacket, to remove all traces of semi-conducting residue. If using an ECS or MA grounding device, install it now following its instructions.

  6. Lubricate Cable and Slide Collar

    Slide the collar, smaller end first, onto each cable. Keep the cable insulation and plug clean. Apply the supplied lubricant sparingly to the cable as shown in the documentation and to the inside of the housing. DO NOT SUBSTITUTE other lubricants, as they may be harmful to the product or its mating product.

  7. Install Cable into Plug Housing

    Push the prepared cable firmly into the plug housing until the leading edge of the socket contact is flush with the front edge of the plug. Once seated, remove the plastic pin from the socket and discard it.

  8. Connect to Mating Receptacle and Secure

    Lubricate the nose of the K151SP plug with silicone grease. Carefully place the nylon rod into the mating receptacle face until it bottoms (approximately 1-3/4 inches), ensuring the rod is not cut during mating. Insert the plug assembly into the receptacle as far as possible. Pull out and remove the nylon rod. Secure the electrical connection using an ELASTIMOLD bail; refer to the Bailing Instruction Sheet (150TB-4) for proper installation. A bailing arrangement is required when this product is used with any mating Elastimold deadbreak product.

  9. Connect System Ground

    If an ELASTIMOLD grounding device is not being used, connect a length of customer-supplied #14 AWG (or equivalent) copper wire through the grounding tab and twist it tightly. Connect the grounding assembly of the connector to the system ground by merging it with the cable shield of each cable. Seal the grounding wires and connections to prevent corrosion.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.