- 35kV rated deadbreak connector for underground distribution systems
- 600 amp continuous current rating with loadbreak capability
- Accommodates 1000 kcmil compressed or stranded copper conductors
- Cable insulation diameter range: 1.725–1.935 inches
- Aluminum lug with EPDM rubber housing for environmental sealing
Specifications
Amperage Rating | 600 A |
Application | Designed to provide Fully Shielded, Dead-Front Submersible Cable Connections to High-Voltage Apparatus |
Color | Black |
Conductor Range | 1000 kcmil |
Environmental Conditions | Fully Submersible |
Insulation | True |
Material | Housing - EPDM-Rubber |
Size | Cable Insulation Diameter 1.725-1.935 inches |
Special Features | 100 Percent Peroxide-Cured Construction includes Insulation and Conductive EPDM Materials. Can be Easily Connected or Disconnected Using Standard Hand Tools and Equipment in a De-energized State. Optional Accessories allow Visible External Separation, By-Pass, Isolation, Dead-Ending, Grounding, and Testing as well as Adding Taps, Surge Arrestors, and Fault Current Indicators |
Standard | ANSI/IEEE Standard 386 |
Temperature Rating, Maximum | 149 F |
Temperature Rating, Maximum | 65 C |
Temperature Rating, Minimum | -40 F |
Temperature Rating, Minimum | -40 C |
Type | Deadbreak Elbow Connector |
Voltage Rating | 35 kV |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 8.9000 L |
Package Weight (Metric) | 4.0370 kg |

775LR-P5410-S-CS1634
900 Amp, 35kV, 600 Series Elbow with insulated plug, cap, stud, lug and cable adapter. Cable Insulation Diameter 1.725 inch to 1.935 inch. Bi-Metal Compression Lug. Conductor Size kcmil Compressed Stranded 1000. Cold-Shrinkable Jacket Seal Included. Factory lubricated receptacle interface and cable entrance of elbow or bushings extender.
162LR-A-5250
15kV 200 Amp, Loadbreak Elbow Connector with Test Point, .575 inch - .740 Inch Cable Insulation Diameter, 2/0 Stranded Wire Size, Bi-Metal Compression Lug
162LR-A-5230
15kV 200 Amp, Loadbreak Elbow Connector with Test Point, .575 inch - .740 Inch Cable Insulation Diameter, #1 Stranded Wire Size, Bi-Metal Compression Lug
162LR-A-5220
15kV 200 Amp, Loadbreak Elbow Connector with Test Point, .575 inch - .740 Inch Cable Insulation Diameter, #2 Stranded Wire Size, Bi-Metal Compression Lug
162LR-A-5240
15kV 200 Amp, Loadbreak Elbow Connector with Test Point, .575 inch - .740 Inch Cable Insulation Diameter, 1/0 Stranded Wire Size, Bi-Metal Compression Lug
162LR-A-5210
15kV 200 Amp, Loadbreak Elbow Connector with Test Point, .575 inch - .740 Inch Cable Insulation Diameter, #3 Stranded Wire Size, Bi-Metal Compression Lug
162LR-A-5220-S
200 Amp, 15kV, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 0.575 inch to 0.740 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded #2/Solid #1/mmSquared 33.62. 200ECS Jacket Seal Included.Frequently Asked Questions
What is the continuous current rating?
The continuous current rating for the 755LR is 600 Amps.
What standard does the 755LR meet?
The 755LR meets ANSI/IEEE Standard 386, Latest Revision.
What items are included in the 755LR kit?
Each kit contains an elbow connector housing, a copper compression lug, a stud, an insulated plug with cap, lubricant tubes, a cable adapter, and installation instructions.
What are the key electrical ratings of the 755LR?
Key ratings include 21.1kV max phase-to-ground operating voltage, 36.6kV max phase-to-phase, and 600 Amp continuous current. It has a 150kV BIL impulse withstand.
What cable insulation diameters does the 755LR support?
The product supports cable insulation diameters ranging from 0.760 inches to 2.120 inches.
What conductor sizes are compatible with this elbow connector?
It is compatible with conductor sizes from #2 AWG to 1250 kcmil for both aluminum and copper conductors.
What is the maximum voltage rating for the 755LR?
The 755LR is designed for use through 35kV voltage class applications.
What is the primary application of the 755LR?
The 755LR provides fully shielded, dead-front submersible cable connections to high-voltage apparatus.
What is the maximum voltage rating for the 755LR?
The 755LR is designed for use through 35kV voltage class applications.
What is the continuous current rating?
The continuous current rating for the 755LR is 600 Amps.
How to Install 755/775LR Deadbreak Elbow Connectors
This guide provides step-by-step instructions for the safe and proper installation of 755LR and 775LR Deadbreak Elbow Connectors, designed for 35kV class systems to provide fully shielded, fully submersible deadfront cable connections.
Estimated time: 2h
Tools needed:
Wire strippers, Utility knife, Measuring tape or ruler, Wire brush (for aluminum conductors), Crimping tool (with appropriate dies), Hotstick, Suitable sensing device for capacitive test points, Torque wrench
Supplies needed:
755LR or 775LR Deadbreak Elbow Connector Kit (includes Elbow, Cable Adapter, Compression Lug, Insulating Plug, Lubricant, Stud Prepack), High voltage cable (compatible with 35kV class systems), Mating apparatus or connector (e.g., bushing, elbow tap plug), Grounding device (e.g., 20MA, 21MA, 600ECS Jacket Cable Seal, or 10TL cable shield adapter, if applicable), Grounding wire (minimum No. 14 AWG Copper), Suitable connector for grounding wire, HV insulated cap(s) or connector(s) (if replacing shipping covers), Vinyl tape (if preparing flat metallic tape shield cable)
- Ensure Safety and Inspect Components
DANGER: De-energize all apparatus in the work area before beginning installation. Do not touch or move energized products. Inspect all parts from the connector kit and mating products for any damage, verify their ratings, and ensure compatibility with the cable and mating parts. Remove any protective shipping covers and replace with appropriate HV insulated caps or connectors before submerging or energizing the circuit. Gather all required tools and maintain cleanliness throughout the procedure.
- Position Cable and Make Initial Cut
Position the cable in its final assembled location, ensuring enough slack is available to allow adequate clearance for removing the elbows. If using concentric neutral cable, unwind the concentric neutral wires. Measure and cut the cable 1-3/4 inches (45mm) from the centerline of the mating product.
- Clean Cable Outer Jacket
Thoroughly clean the outer jacket of the cable for a distance of 24 inches (610mm) from the cut end.
- Prepare Cable According to Type
Follow the specific cable preparation instructions based on your cable type. If using a 20MA or 21MA grounding device or 600ECS Jacket Cable Seal, refer to their respective installation instructions. For UNISHIELD* or LEAD SHEATH cable, refer to the 10TL cable shield adapter instructions. For jacketed and non-jacketed cables, remove the outer jacket (if applicable) and prepare the cable insulation and semi-con shield to the specified dimensions (10-3/8 inches, 11-3/8 inches, and 13-5/8 inches from the mating product centerline for the tape marker, semi-con shield, and cable insulation respectively).
- Install Cable Adapter
Bevel the end of the cable insulation at a 45-degree angle, approximately 1/4 inch (6mm) back. Thoroughly clean and then lubricate the cable insulation, always working toward the semi-con shield. Install the cable adapter, small end first, until it is flush with the edge of the tape marker.
- Prepare Conductor Length
Carefully remove the protruding cable insulation by cutting it even with the end of the cable adapter. WARNING: Do not cut or nick the cable adapter or the conductor. Verify that the length of the exposed conductor is between 4-3/8 inches to 4-3/4 inches (111mm-121mm). If the length is outside this range, redo the assembly.
- Install Compression Lug
For copper conductors, fully insert the conductor into the compression lug. For aluminum conductors, wire brush the conductor immediately before fully inserting it into the compression lug. Measure the 'Check Dimension' before crimping; it should be less than 7 inches (178mm). If not, redo the assembly. Crimp the compression lug following the crimping instructions supplied with the lug. Wipe all excess inhibitor from the compression lug and cable adapter surface after crimping. Verify the distance from the end of the compression lug to the cable adapter after crimping is between 6-7/8 inches to 7-5/8 inches (175mm-194mm). If not, redo the assembly.
- Install Elbow onto Cable Adapter
Lubricate the cable adapter and the inside of the elbow's cable entrance. Install the elbow onto the cable adapter until it cannot advance further. Ensure the cable adapter remains flush with the tape marker; reposition if necessary. Remove the tape marker.
- Prepare Mating Products for Connection
WARNING: DO NOT CONNECT OR DISCONNECT MATING PRODUCTS WHILE ENERGIZED. DO NOT ENERGIZE WHILE DISCONNECTED. Remove any protective caps from both the elbow and the mating part. If the mating part is not equipped with a stud, hand tighten the threaded stud supplied with the elbow into the mating part. Clean and lubricate both the elbow and the mating part with the supplied lubricant, ensuring surfaces remain clean.
- Connect Elbow to Mating Part
Push the elbow onto the mating part, carefully lining up the hole in the compression lug with the stud on the mating part.
- Connect Opposite End of Elbow (if applicable)
If connecting to another mating part on the opposite end of the elbow, clean and lubricate its mating surface. Insert the mating part into the elbow, engage the threads, and hand tighten. Torque the mating part according to the instructions supplied with that specific mating part.
- Install Insulating Plug (if used)
If an insulating plug is used as a mating part, clean and lubricate the inner surface of the voltage detection cap. Place the cap on the elbow and push down firmly until it snaps into place.
- Ground the Cable Shield
Insert one end of a piece of wire, with an ampacity at least equivalent to No. 14 AWG Copper, through the grounding eye and twist to create a small loop. Do not damage the grounding eye. Connect this wire to ground using a suitable connector. The shield of the cable must be grounded; ground it according to the instructions supplied with your grounding device, or through an alternate approved method if no grounding device is used. It is also recommended to waterproof the cable jacket at this point to prevent moisture ingress.
- Perform Voltage Test (Optional but Recommended)
CAUTION: When constructing 600amp L-Kits, ensure each component is tightened to the specified torque per the plug connector instructions. To perform a voltage test, remove the test point cap with a hotstick by peeling it off at an angle, rather than pulling directly. WARNING: The voltage test point is a capacitance device and is not directly connected to the conductor. Do not use conventional voltage measuring equipment. Use a suitable sensing device specifically designed for separable connectors with capacitive test points, following the manufacturer's directions. Contamination, moisture, or dirt around the test point, or using incorrect equipment, can lead to a false 'no voltage' indication. Treat the elbow as energized until a 'no voltage' indication is confirmed by other means to prevent serious or fatal injury. After testing, clean and lubricate the inside surface of the cap with silicone lubricant and replace it on the test point.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.