ABB - Installation Products 162LR-A-5220 - 15kV 200 Amp, Loadbreak Elbow Connector with Test Point, .575 inch - .740 Inch Cable Insulation Diameter, #2 Stranded Wire Size, Bi-Metal Compression Lug
More images

ABB Installation Products 162LR-A-5220 15kV 200 Amp, Loadbreak Elbow Connector with Test Point, .575 inch - .740 Inch Cable…

UPC: 075114186216


Documents & Media
BrochureInstallation InstructionsManufacturer Product Website

Contact for Pricing

Minimum Qty: 15

Multiplier: 15

*Contact for lower quantities*

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB 162LR-A-5220 is a 15kV, 200 Amp loadbreak elbow connector engineered for medium-voltage power distribution systems. This connector is designed to accommodate cable insulation diameters ranging from 0.575 inches to 0.740 inches, ensuring compatibility with a variety of medium-voltage cables in utility, industrial, and commercial applications. The built-in test point allows for safe and efficient circuit testing without connector removal, reducing downtime and enhancing operational safety. The bi-metal compression lug supports #2 stranded wire sizes, providing a secure and durable connection with electrical integrity in demanding environments. The connector is part of ABB's 15kV Loadbreak (Enhanced) series, optimized for reliable performance in loadbreak switching applications. Key specifications include a voltage rating of 15kV, current rating of 200 Amps, and compatibility with cable insulation diameters from 0.575" to 0.740". The bi-metal compression lug ensures compatibility with both copper and aluminum conductors, offering versatility in conductor material selection. This product is ideal for applications requiring dependable loadbreak capabilities, such as pad-mounted switchgear, transformers, and underground distribution systems. The ABB 162LR-A-5220 is a critical component for systems where consistent performance and electrical integrity are paramount.
  • 15kV voltage rating with 200 Amp current capacity
  • Accommodates cable insulation diameters from 0.575" to 0.740"
  • Built-in test point for safe circuit testing without connector removal
  • Bi-metal compression lug supports #2 stranded wire sizes
  • Compatible with both copper and aluminum conductors

Specifications

Amperage Rating
200 A
Application
The 162LR is designed for Connecting to and Operating 15kV Class, 200 Amp Distribution apparatus. It Provides a Convenient Method to Connect/Disconnect Cable and Equipment on Power Distribution Systems
Color
Black
Conductor Range
#2 STR/COMPR AWG , #1 SOL/COMPT AWG
Connection Type
Compression Lug
Current Rating
200 A
Environmental Conditions
Products are designed and constructed for all applications including Padmount, Subsurface, Vault, Indoor, Outdoor, Direct Sunlight, Direct Buried and Continuously Submerged in Water
Insulation
True
Material
Bi-Metal
Material
Housing - EPDM-Rubber
Size
0.575"-0.740"
Special Features
Fully Shielded, Fully Submersible Molded Rubber Housing, 100 Percent Peroxide-Cured Construction includes Insulation and Conductive EPDM Materials. Provision for Hot Stick Operation. Provision for Ground Wire Connection. Non-Corrosive Capacitive Test Point
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Loadbreak Elbow Connector with Test Point
Voltage Rating
15 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
2.1200 L
Package Weight (Metric)
0.9620 kg
15-25kV 600 Series Deadbreak Separable Wye Joint Package (3-Way) with Test Point, Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded #2 or Compacted Solid #1.

K656CY-J0220

15-25kV 600 Series Deadbreak Separable Wye Joint Package (3-Way) with Test Point, Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded #2 or Compacted Solid #1.
15kV 200 Amp, Loadbreak Elbow Connector with Test Point, .575 inch - .740 Inch Cable Insulation Diameter, 1/0 Stranded Wire Size, Bi-Metal Compression Lug

162LR-A-5240

15kV 200 Amp, Loadbreak Elbow Connector with Test Point, .575 inch - .740 Inch Cable Insulation Diameter, 1/0 Stranded Wire Size, Bi-Metal Compression Lug
15kV 200 Amp, Loadbreak Elbow Connector with Test Point, .575 inch - .740 Inch Cable Insulation Diameter, #3 Stranded Wire Size, Bi-Metal Compression Lug

162LR-A-5210

15kV 200 Amp, Loadbreak Elbow Connector with Test Point, .575 inch - .740 Inch Cable Insulation Diameter, #3 Stranded Wire Size, Bi-Metal Compression Lug
200 Amp, 15kV, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 0.575 inch to 0.740 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded #2/Solid #1/mmSquared 33.62. 200ECS Jacket Seal Included.

162LR-A-5220-S

200 Amp, 15kV, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 0.575 inch to 0.740 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded #2/Solid #1/mmSquared 33.62. 200ECS Jacket Seal Included.
600 Amp, 35kV, 600 Series Deadbreak Elbow (with Insulated Plug, Cap, Stud, Lug and Cable Adapter). Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 450 /Compacted Solid 500/550.

755LR-N0320

600 Amp, 35kV, 600 Series Deadbreak Elbow (with Insulated Plug, Cap, Stud, Lug and Cable Adapter). Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 450 /Compacted Solid 500/550.
600 Amp, 35kV, 600 Series Deadbreak Elbow (with Insulated Plug, Cap, Stud, Lug and Cable Adapter). Cable Insulation Diameter 1.370 inch to 1.630 inch. Copper Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 600 /Compacted Solid 600.

755LR-M2350

600 Amp, 35kV, 600 Series Deadbreak Elbow (with Insulated Plug, Cap, Stud, Lug and Cable Adapter). Cable Insulation Diameter 1.370 inch to 1.630 inch. Copper Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 600 /Compacted Solid 600.
600 Amp, 35kV, 600 Series Deadbreak Elbow (with Insulated Plug, Cap, Stud, Lug and Cable Adapter). Cable Insulation Diameter 1.370 inch to 1.630 inch. Copper Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 4/0 /Compacted Solid 250 /mmSquared Compact 125.

755LR-M2270

600 Amp, 35kV, 600 Series Deadbreak Elbow (with Insulated Plug, Cap, Stud, Lug and Cable Adapter). Cable Insulation Diameter 1.370 inch to 1.630 inch. Copper Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 4/0 /Compacted Solid 250 /mmSquared Compact 125.
600 Amp, 35kV, 600 Series Deadbreak Elbow (with Insulated Plug, Cap, Stud, Lug and Cable Adapter). Cable Insulation Diameter 1.370 inch to 1.630 inch. Copper Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 400 /Compacted Solid 450 /mmSquared Compact 240. No Sealing Kit

755LR-M2310

600 Amp, 35kV, 600 Series Deadbreak Elbow (with Insulated Plug, Cap, Stud, Lug and Cable Adapter). Cable Insulation Diameter 1.370 inch to 1.630 inch. Copper Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 400 /Compacted Solid 450 /mmSquared Compact 240. No Sealing Kit

Frequently Asked Questions

What standards and certifications does the elbow meet?

The enhanced Elastimold loadbreak elbow is IEEE 386 compliant, ANSI certified, and has Rural Utilities Service (RUS) acceptance.

What are the voltage and current ratings for this elbow?

The Elastimold loadbreak elbow is rated for 200 amps and is available for 15 kV and 25 kV systems.

What standards and certifications does the elbow meet?

The enhanced Elastimold loadbreak elbow is IEEE 386 compliant, ANSI certified, and has Rural Utilities Service (RUS) acceptance.

What are the voltage and current ratings for this elbow?

The Elastimold loadbreak elbow is rated for 200 amps and is available for 15 kV and 25 kV systems.

What are the voltage and current ratings for this elbow?

The Elastimold loadbreak elbow is rated for 200 amps and is available for 15 kV and 25 kV systems.

What standards and certifications does the elbow meet?

The enhanced Elastimold loadbreak elbow is IEEE 386 compliant, ANSI certified, and has Rural Utilities Service (RUS) acceptance.

What are the voltage and current ratings for this elbow?

The Elastimold loadbreak elbow is rated for 200 amps and is available for 15 kV and 25 kV systems.

What standards and certifications does the elbow meet?

The enhanced Elastimold loadbreak elbow is IEEE 386 compliant, ANSI certified, and has Rural Utilities Service (RUS) acceptance.

How does the elbow reduce life cycle costs?

It is optimized for switching operations, offers lifetime ease of operation and non-stick performance with Elastimold bushings, and has an improved seal system.

How does the enhanced elbow offer increased flexibility?

It offers additional sizes, improved wider cable ranges, and an optional integral jacket seal.

How to Install the 162LR Loadbreak Elbow Connector

This guide provides comprehensive instructions for the safe installation and initial setup of the 162LR Loadbreak Elbow Connector, covering cable preparation, assembly, grounding, and connection to a de-energized bushing.

Estimated time: 1h 30m

Tools needed:

Probe Wrench, Wire brush, Crimp tool, Wire strippers, Utility knife or cable cutting tool, Hotstick, Suitable sensing device

Supplies needed:

Elbow Connector Housing, Compression Lug, Probe, Lubricant (supplied, do not substitute), Copper wire (No. 14 AWG / 2.5mm) or equivalent, Appropriate connector (for neutral wires), Vinyl tape (if applicable for cable type), Cold shrink tube (if using sealing kit), Conductive copper tape (if using sealing kit), HV insulated cap(s) or connector(s)

  1. Ensure De-energized State and Inspect Components

    Before beginning, ensure all apparatus is de-energized. Inspect all parts for damage, proper rating, and compatibility. Check package contents for completeness and verify fit with cable/mating products. Thread probe into compression lug by hand to check for resistance; replace if damaged. Have all required tools at hand and maintain cleanliness.

  2. Prepare Cable for Initial Termination

    Train cable for slack. Cut excess cable squarely at the bushing centerline. Based on your cable type (concentric neutral, jacketed, drain wires, or copper tape shield), follow the document's specific instructions for removing the outer jacket and/or copper tape shield, and for unwrapping/binding neutral/drain wires. If using a sealing kit, slide the cold shrink tube onto the cable loose end first.

  3. Perform Detailed Cable Preparation

    Remove insulation shield and insulation 2-1/8 inches (55mm) from cable end, cutting squarely without nicks. Wire brush aluminum conductors and immediately install the compression lug. Rotate lug to spread inhibitor, aligning threaded hole with bushing bore. Crimp lug per chart, starting at crimp line, rotating 180 degrees each crimp. Wipe excess inhibitor. Remove insulation shield 6-7/8 inches (175mm) back, ensuring a straight, smooth, squared cut. Bevel insulation end max 1/8 inch (5mm). Thoroughly clean insulation.

  4. Assemble the Elbow Connector

    Lubricate cable insulation and inside elbow housing with supplied lubricant; DO NOT SUBSTITUTE. Keep insulation clean. Slide elbow connector onto cable with a twisting motion, then wipe off excess lubricant. Align elbow with compression lug’s threaded hole. Thread probe into lug by hand, ensuring it turns freely for ~4 turns before snugging. Tighten probe with supplied wrench until the wrench bends.

  5. Ground the Elbow and Neutral Wires

    Insert one end of a separate copper wire (No. 14 AWG / 2.5mm) or equivalent through the grounding eye on the elbow. Twist tightly, taking care not to damage the eye. Twist all neutral wires together and connect them to ground using an appropriate connector. Ensure adequate slack in the wires for elbow operation. If using a cold shrink grounding kit, refer to its specific instructions to complete this step.

  6. Connect Elbow to De-energized Bushing

    CONFIRM THAT THE TRANSFORMER AND ELBOW ARE DE-ENERGIZED before proceeding. Lubricate the receptacle portion of the elbow connector and the mating bushing with the supplied lubricant. Securely fasten a hotstick to the loadbreak connector pulling eye. Carefully insert the elbow connector onto the bushing. DO NOT OPERATE BY HAND; use the hotstick for all connections.

  7. Perform Voltage Test (for 162LR with Test Point)

    If your 162LR has a test point, use it to determine if the circuit is energized. Remove the test point cap with a hotstick, peeling at an angle. WARNING: This is a capacitance device, not directly connected to the conductor. Do not use conventional voltage measuring equipment; follow your sensing device's directions. Treat elbow as energized until 'no voltage' is confirmed by other means. After testing, clean cap, lubricate with silicone, and replace.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.