Authorized ABB Distributor (Installation Products)
ABB - Installation Products 162LR-A-5220-S - 200 Amp, 15kV, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 0.575 inch to 0.740 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded #2/Solid #1/mmSquared 33.62. 200ECS Jacket Seal Included.

ABB Installation Products 162LR-A-5220-S 200 Amp, 15kV, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter…

UPC: 075114186261


Documents & Media
BrochureInstallation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB 162LR-A-5220-S is a 200 Amp, 15kV loadbreak elbow connector designed for underground residential distribution (URD) systems. This bi-metal compression lug connector accommodates cable insulation diameters from 0.575 inch to 0.740 inch, making it compatible with #2 AWG compressed stranded or #1 AWG solid conductors (33.62 mm² cross-section). The integrated test point allows for safe voltage verification without disconnecting the elbow, reducing outage time during maintenance or fault isolation. The 200ECS jacket seal included provides environmental protection against moisture and contaminants, ensuring long-term reliability in underground applications. This connector meets utility-grade standards for loadbreak operations, allowing for hot-line switching up to 15kV while maintaining dielectric integrity. Typical applications include pad-mounted transformers, switchgear, and underground cable terminations where safe, reliable loadbreak capability is required. The bi-metal construction ensures compatibility between copper and aluminum conductors, preventing galvanic corrosion issues common in mixed-metal systems. Installation requires standard compression tooling for the lug and proper torque application to maintain electrical contact integrity. The catalog number follows ABB’s structured format: 162LR-W5X, where 'W' denotes the insulation diameter range (0.575-0.740 inch) and 'X' represents the compression lug code for #2/#1 AWG conductors. This product is part of ABB’s 15 kV loadbreak elbow connector series, which includes variants with and without test points and jacket seals for flexible system integration.
  • 200 Amp, 15kV rated loadbreak elbow connector for URD systems
  • Bi-metal compression lug compatible with #2 AWG compressed stranded or #1 AWG solid conductors (33.62 mm²)
  • Integrated test point enables safe voltage verification without disconnection
  • Includes 200ECS jacket seal for moisture and contaminant protection
  • Hot-line switching capability up to 15kV with maintained dielectric integrity

Specifications

Amperage Rating
200 A
Application
The 162LR is designed for Connecting to and Operating 15kV Class, 200 Amp Distribution apparatus. It Provides a Convenient Method to Connect/Disconnect Cable and Equipment on Power Distribution Systems
Color
Black
Conductor Range
#2 STR/COMPR AWG , #1 SOL/COMPT AWG
Environmental Conditions
Products are designed and constructed for all applications including Padmount, Subsurface, Vault, Indoor, Outdoor, Direct Sunlight, Direct Buried and Continuously Submerged in Water
Insulation
True
Material
Housing - EPDM-Rubber
Special Features
Fully Shielded, Fully Submersible Molded Rubber Housing, 100 Percent Peroxide-Cured Construction includes Insulation and Conductive EPDM Materials. Provision for Hot Stick Operation. Provision for Ground Wire Connection. Non-Corrosive Capacitive Test Point
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Loadbreak Elbow Connector with Test Point
Voltage Rating
15 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
25kV, 600 Amp, Deadbreak Elbow, No Sealing Kit, without Test Point, Cable Insulation .640-.820 inches, Bi-Metal Lug, Conductor Size AWG Compressed/Stranded #2 or Compacted/Solid #1 or mm2 Compact 35.

K655LR-F5220

25kV, 600 Amp, Deadbreak Elbow, No Sealing Kit, without Test Point, Cable Insulation .640-.820 inches, Bi-Metal Lug, Conductor Size AWG Compressed/Stranded #2 or Compacted/Solid #1 or mm2 Compact 35.
600 Amp, 35kV, 600 Series Deadbreak Elbow (with Insulated Plug, Cap, Stud, Lug and Cable Adapter). Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 450 /Compacted Solid 500/550.

755LR-N0320

600 Amp, 35kV, 600 Series Deadbreak Elbow (with Insulated Plug, Cap, Stud, Lug and Cable Adapter). Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 450 /Compacted Solid 500/550.
600 Amp, 35kV, 600 Series Deadbreak Elbow (with Insulated Plug, Cap, Stud, Lug and Cable Adapter). Cable Insulation Diameter 1.370 inch to 1.630 inch. Copper Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 600 /Compacted Solid 600.

755LR-M2350

600 Amp, 35kV, 600 Series Deadbreak Elbow (with Insulated Plug, Cap, Stud, Lug and Cable Adapter). Cable Insulation Diameter 1.370 inch to 1.630 inch. Copper Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 600 /Compacted Solid 600.
600 Amp, 35kV, 600 Series Deadbreak Elbow (with Insulated Plug, Cap, Stud, Lug and Cable Adapter). Cable Insulation Diameter 1.370 inch to 1.630 inch. Copper Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 4/0 /Compacted Solid 250 /mmSquared Compact 125.

755LR-M2270

600 Amp, 35kV, 600 Series Deadbreak Elbow (with Insulated Plug, Cap, Stud, Lug and Cable Adapter). Cable Insulation Diameter 1.370 inch to 1.630 inch. Copper Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 4/0 /Compacted Solid 250 /mmSquared Compact 125.
600 Amp, 35kV, 600 Series Deadbreak Elbow (with Insulated Plug, Cap, Stud, Lug and Cable Adapter). Cable Insulation Diameter 1.370 inch to 1.630 inch. Copper Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 400 /Compacted Solid 450 /mmSquared Compact 240. No Sealing Kit

755LR-M2310

600 Amp, 35kV, 600 Series Deadbreak Elbow (with Insulated Plug, Cap, Stud, Lug and Cable Adapter). Cable Insulation Diameter 1.370 inch to 1.630 inch. Copper Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 400 /Compacted Solid 450 /mmSquared Compact 240. No Sealing Kit
600 Amp, 35kV, 600 Series Deadbreak Elbow (with Insulated Plug, Cap, Stud, Lug and Cable Adapter). Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 700/750 /Compacted Solid 900.

755LR-M0380

600 Amp, 35kV, 600 Series Deadbreak Elbow (with Insulated Plug, Cap, Stud, Lug and Cable Adapter). Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 700/750 /Compacted Solid 900.
600 Amp, 35kV, 600 Series Deadbreak Elbow (with Insulated Plug, Cap, Stud, Lug and Cable Adapter). Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 450 /Solid 500/550.

755LR-M0320

600 Amp, 35kV, 600 Series Deadbreak Elbow (with Insulated Plug, Cap, Stud, Lug and Cable Adapter). Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 450 /Solid 500/550.
200 Amp, 15kV, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 0.575 inch to 0.740 inch. Copper Compression Lug. Conductor Size AWG Compressed Stranded #2/Solid #1/mmSquared 33.62.

162LR-A-2220

200 Amp, 15kV, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 0.575 inch to 0.740 inch. Copper Compression Lug. Conductor Size AWG Compressed Stranded #2/Solid #1/mmSquared 33.62.

Frequently Asked Questions

What is the current rating of the loadbreak elbow?

The Elastimold loadbreak elbow has a current rating of 200 amps.

What voltage ratings are available for the elbow?

The Elastimold 200 amp loadbreak elbow is available in 15 kV and 25 kV series.

Does the elbow have a no-stick interface?

Yes, it features a no-stick interface when used with Elastimold bushings, which has been NEETRAC tested.

What certifications does the Elastimold elbow have?

It has Rural Utilities Service (RUS) acceptance from the U.S. Department of Agriculture (USDA), IEEE 386 compliance, and ANSI certification.

What is the Elastimold 200 amp loadbreak elbow?

It is an enhanced 200 amp loadbreak elbow available in 15 kV and 25 kV series, designed for easier switching.

Does the elbow have a no-stick interface?

Yes, it features a no-stick interface when used with Elastimold bushings, which has been NEETRAC tested.

What is the Elastimold 200 amp loadbreak elbow?

It is an enhanced 200 amp loadbreak elbow available in 15 kV and 25 kV series, designed for easier switching.

What certifications does the Elastimold elbow have?

It has Rural Utilities Service (RUS) acceptance from the U.S. Department of Agriculture (USDA), IEEE 386 compliance, and ANSI certification.

What voltage ratings are available for the elbow?

The Elastimold 200 amp loadbreak elbow is available in 15 kV and 25 kV series.

What is the current rating of the loadbreak elbow?

The Elastimold loadbreak elbow has a current rating of 200 amps.

How to Install 161LR/162LR Loadbreak Elbow Connectors

This guide provides step-by-step instructions for the safe and proper installation of 161LR and 162LR Loadbreak Elbow Connectors, including cable preparation, elbow assembly, grounding, and initial connection to a de-energized bushing.

Estimated time: 1h 30m

Tools needed:

Probe Wrench, Wire brush, Crimp tool, Hotstick, Wire strippers, Cable cutter

Supplies needed:

Elbow Connector Housing, Compression Lug, Probe, Lubricant (Do Not Substitute), Copper wire (No. 14 AWG / 2.5mm), Appropriate neutral wire connector, Cold shrink tube (if using sealing kit), Conductive copper tape (if using G2/G3 kit), Vinyl tape (if using drain wire cable)

  1. Perform Pre-Installation Checks and Safety Review

    Before starting, ensure all apparatus is de-energized. Inspect the package contents for completeness and damage. Verify all components fit properly with the cable and mating products. Check the probe threads by hand-threading into the compression lug; replace if resistance is encountered. Review all safety warnings regarding high voltage equipment and ensure installation is performed by competent personnel.

  2. Prepare the Cable for Termination

    Train the cable to provide adequate slack for operation. Based on your cable type (non-jacketed concentric neutral, jacketed concentric neutral, jacketed with drain wires, or jacketed copper tape shield), follow the specific instructions in the documentation for removing the outer jacket, unwrapping/binding neutral or drain wires, and cutting the cable squarely at the bushing centerline. If using a cold shrink sealing kit, slide the cold shrink tube onto the cable at this stage.

  3. Prepare the Cable End and Install Compression Lug

    Remove 2-1/8 inches (55mm) of shield and insulation from the cable end, ensuring a square cut without nicking the conductor. Wire brush bare aluminum conductors immediately. Install the compression lug, rotating it to spread inhibitor, and align its threaded hole with the bushing bore. Crimp the lug according to the crimp chart, starting at the crimp line mark and rotating 180 degrees for each successive crimp. Carefully wipe off any excess inhibitor.

  4. Final Insulation Preparation

    Remove the insulation shield 6-7/8 inches (175mm) from the compression lug end. Bevel the insulation end a maximum of 1/8 inch (5mm). Thoroughly clean the insulation to remove all traces of dirt or excess inhibitor, ensuring a straight, smooth, and squared surface.

  5. Assemble the Elbow Connector

    Lubricate the cable insulation and the inside of the elbow housing with the supplied lubricant; do not substitute. Slide the elbow connector onto the cable using a back-and-forth twisting motion, then wipe off any excess lubricant. Align the elbow with the compression lug's threaded hole. Thread the probe into the lug by hand, ensuring it turns freely for approximately four turns before becoming snug. Tighten the probe with the wrench until the wrench bends.

  6. Ground the Elbow Connector

    Insert one end of a separate No. 14 AWG (2.5mm) copper wire or equivalent through the grounding eye on the elbow and twist it tightly, taking care not to damage the eye. Twist all neutral wires together and connect them to ground using an appropriate connector, ensuring adequate slack for elbow operation. If using a cold shrink grounding kit, follow its specific instructions.

  7. Connect the Elbow to the Bushing Plug

    CONFIRM THAT THE TRANSFORMER AND ELBOW ARE DE-ENERGIZED before proceeding. Lubricate the receptacle portion of the elbow connector and the mating bushing with the supplied lubricant. Securely fasten a hotstick to the loadbreak connector pulling eye. Insert the probe tip approximately 2 inches (50mm) into the bushing, then immediately push the elbow home with a fast, firm, straight motion, using sufficient force to engage the internal lock. Do not operate by hand.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.