ABB Installation Products 162LR-A-5230 15kV 200 Amp, Loadbreak Elbow Connector with Test Point, .575 inch - .740 Inch Cable…
UPC: 075114186278
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- 15kV voltage rating for medium-voltage applications
- 200 Amp continuous current rating
- Accommodates cable insulation diameters from .575" to .740"
- Integrated test point for safe circuit testing
- Bi-metal compression lug for versatile conductor connections
Specifications
Amperage Rating | 200 A |
Application | The 162LR is designed for Connecting to and Operating 15kV Class, 200 Amp Distribution apparatus. It Provides a Convenient Method to Connect/Disconnect Cable and Equipment on Power Distribution Systems |
Color | Black |
Conductor Range | #1 STR/COMPR AWG , 1/0 SOL/COMPT AWG |
Connection Type | Loadbreak Elbow Connector with Test Point |
Current Rating | 200 A |
Environmental Conditions | Products are designed and constructed for all applications including Padmount, Subsurface, Vault, Indoor, Outdoor, Direct Sunlight, Direct Buried and Continuously Submerged in Water |
Insulation | True |
Material | Bi-Metal Compression Lug |
Material | Housing - EPDM-Rubber |
Series | 162LR-A |
Special Features | Fully Shielded, Fully Submersible Molded Rubber Housing, 100 Percent Peroxide-Cured Construction includes Insulation and Conductive EPDM Materials. Provision for Hot Stick Operation. Provision for Ground Wire Connection. Non-Corrosive Capacitive Test Point |
Standard | ANSI/IEEE Standard 386 |
Temperature Rating, Maximum | 149 F |
Temperature Rating, Maximum | 65 C |
Temperature Rating, Minimum | -40 F |
Temperature Rating, Minimum | -40 C |
Type | Loadbreak Elbow Connector with Test Point |
Voltage Rating | 15 kV |
Voltage Rating | 15kV |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 1.0000 L |
Package Weight (Metric) | 0.4540 kg |

K656YSR-H0230
600 Amp, 15/25kV, Deadbreak, Straight Receptacle with Test Point, Cable Insulation Diameter .850 inch to 1.050 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded #1 or Compacted Solid 1/0.
162LR-A-5220
15kV 200 Amp, Loadbreak Elbow Connector with Test Point, .575 inch - .740 Inch Cable Insulation Diameter, #2 Stranded Wire Size, Bi-Metal Compression Lug
162LR-A-5240
15kV 200 Amp, Loadbreak Elbow Connector with Test Point, .575 inch - .740 Inch Cable Insulation Diameter, 1/0 Stranded Wire Size, Bi-Metal Compression Lug
162LR-A-5210
15kV 200 Amp, Loadbreak Elbow Connector with Test Point, .575 inch - .740 Inch Cable Insulation Diameter, #3 Stranded Wire Size, Bi-Metal Compression Lug
162LR-A-5220-S
200 Amp, 15kV, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 0.575 inch to 0.740 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded #2/Solid #1/mmSquared 33.62. 200ECS Jacket Seal Included.
755LR-N0320
600 Amp, 35kV, 600 Series Deadbreak Elbow (with Insulated Plug, Cap, Stud, Lug and Cable Adapter). Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 450 /Compacted Solid 500/550.
755LR-M2350
600 Amp, 35kV, 600 Series Deadbreak Elbow (with Insulated Plug, Cap, Stud, Lug and Cable Adapter). Cable Insulation Diameter 1.370 inch to 1.630 inch. Copper Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 600 /Compacted Solid 600.
755LR-M2270
600 Amp, 35kV, 600 Series Deadbreak Elbow (with Insulated Plug, Cap, Stud, Lug and Cable Adapter). Cable Insulation Diameter 1.370 inch to 1.630 inch. Copper Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 4/0 /Compacted Solid 250 /mmSquared Compact 125.Frequently Asked Questions
What is the maximum voltage rating for this elbow connector?
The ABB 162LR-A-5230 loadbreak elbow connector has a maximum voltage rating of 15kV.
What is the current carrying capacity of this connector?
This loadbreak elbow connector is rated for 200 Amps.
What cable insulation diameters can this connector accommodate?
The connector is designed for cable insulation diameters ranging from .575 inches to .740 inches.
What type of wire size is this connector designed for?
This connector is suitable for #1 stranded wire.
Does this connector have a test point?
Yes, the ABB 162LR-A-5230 features a built-in test point for circuit testing.
What type of lug is included with this connector?
The connector includes a bi-metal compression lug.
How to Install 162LR Loadbreak Elbow Connectors
This guide provides step-by-step instructions for the safe and proper installation of 161LR and 162LR Loadbreak Elbow Connectors, including cable preparation, assembly, grounding, and initial connection to a bushing.
Estimated time: 1h 30m
Tools needed:
Cable cutters, Wire strippers, Wire brush, Crimp tool, Probe wrench, Cleaning cloth, Hotstick
Supplies needed:
162LR Elbow Connector Housing, Compression Lug, Probe, Lubricant (supplied, do not substitute), UD Cable, No. 14 AWG (2.5mm) copper wire, Appropriate neutral connector, Vinyl tape (if using drain wires), Conductive copper tape (if using copper tape shield cable), Cold shrink tube (if using sealing kit)
- Ensure Safety and Inspect Components
Before starting, ensure all apparatus is de-energized. This product must be installed only by competent personnel trained in good safety practices involving high voltage electrical equipment. Inspect all package contents and components for completeness, damage, rating, and proper fit with the cable and mating products. Check the probe threads by hand-threading it into the compression lug; replace any damaged component if resistance is encountered prior to full assembly.
- Prepare the Cable Ends
Train the cable to ensure adequate slack for ease of operation. Depending on the cable type, prepare neutral or drain wires by unwrapping and binding them back, or wrapping with conductive copper tape. Cut the cable squarely at the bushing centerline. Remove the outer jacket (if applicable). Remove 2-1/8 inches (55mm) of the shield and insulation from the cable end, cutting squarely and taking care not to nick the conductor. Remove the insulation shield 6-7/8 inches (175mm) back from the cable end. Bevel the insulation end by a maximum of 1/8 inch (5mm). Thoroughly clean the insulation to remove all traces of dirt or excess inhibitor.
- Install the Compression Lug
Wire brush the bare aluminum conductors immediately after stripping. Install the compression lug, ensuring the contact threaded hole aligns with the bushing bore. Crimp the lug according to the manufacturer's chart packaged with the compression lug, starting at the crimp line mark and rotating 180 degrees for each successive crimp. Carefully wipe any excess inhibitor from the outside of the lug and cable.
- Assemble the Elbow Housing and Probe
Lubricate the cable insulation and the inside of the elbow housing with the supplied lubricant; DO NOT SUBSTITUTE other lubricants as they may be harmful. Keep the insulation clean of dirt and grime. Slide the elbow connector onto the cable using a back-and-forth twisting motion, then wipe off all excess lubricant. Align the elbow with the compression lug's threaded hole. Thread the probe into the lug by hand, taking care not to cross-thread. The probe must turn freely for approximately four turns before becoming snug. Tighten the probe with the supplied wrench until the wrench bends.
- Connect Grounding and Neutral Wires
Insert one end of a separate No. 14 AWG (2.5mm) copper wire or equivalent through the grounding eye on the elbow and twist tightly, being careful not to damage the eye. Twist all neutral wires together and connect them to ground using an appropriate connector, ensuring adequate slack in the wires for elbow operation. If using a cold shrink grounding kit, refer to its specific instructions.
- Connect Elbow to Mating Bushing
CONFIRM THAT THE TRANSFORMER AND ELBOW ARE DE-ENERGIZED before proceeding with this step. Lubricate the receptacle portion of the elbow connector and the mating bushing with the supplied lubricant. Securely fasten a hotstick to the loadbreak connector pulling eye. Insert the probe tip approximately 2 inches (50mm) into the bushing, then immediately push the elbow home with a fast, firm, straight motion to engage the internal lock on the elbow connector and bushing interface. DO NOT OPERATE BY HAND.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.