ABB - Installation Products K465LR-H0310 - 15/25kV, 630 Amps, Deadbreak Elbow without Test Point. Cable Insulation Diameter 0.850-1.050 inches (21.590-26.670mm). Aluminum Compression Lug, Conductor Size 400 Stranded/Compressed or 450 Solid/Compact or 240 mm2. Includes Elbow Connector Housing, Compression Lug, Stud, Insulated Plug with Cap, Tube Lubricant, Cable Adapter, Installation Instructions and Crimp Chart. Exceeds ANSI/IEEE Standard 386 Latest Revision.

ABB Installation Products K465LR-H0310 15/25kV, 630 Amps, Deadbreak Elbow without Test Point. Cable Insulation Diameter…

UPC: 783786399802


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB K465LR-H0310 is a 15/25kV, 630 Amp deadbreak elbow connector engineered for reliable medium-voltage cable terminations in underground distribution systems, pad-mounted transformers, and switchgear. This deadbreak elbow does not include a test point, making it ideal for applications where test access is unnecessary. The connector supports cable insulation diameters from 0.850 to 1.050 inches (21.590–26.670 mm) and accommodates conductor sizes of 400 stranded/compressed, 450 solid/compact, or 240 mm², ensuring compatibility with a wide range of medium-voltage cables. The kit includes all essential components for installation: an elbow connector housing, aluminum compression lug, stud, insulated plug with cap, tube lubricant, cable adapter, installation instructions, and a crimp chart. Designed for fully shielded, dead-front submersible connections, the K465LR-H0310 delivers secure, insulated terminations in harsh environments. The aluminum compression lug ensures strong mechanical and electrical connections, while the insulated plug protects against moisture and contaminants. The included lubricant and adapter streamline installation, reducing downtime and labor costs. This deadbreak elbow is commonly used in underground distribution systems, pad-mounted transformers, switchgear, and other medium-voltage applications where a reliable, insulated termination is critical. Exceeds ANSI/IEEE Standard 386 Latest Revision.
  • 15/25kV voltage class, 630 Amp continuous rating
  • Supports cable insulation diameters 0.850-1.050 inches (21.590-26.670 mm)
  • Accommodates conductor sizes 400 stranded/compressed, 450 solid/compact, or 240 mm²
  • Fully shielded, dead-front submersible design for harsh environments
  • Includes elbow connector housing, aluminum compression lug, stud, insulated plug with cap, tube lubricant, cable adapter, installation instructions, and crimp chart

Specifications

Amperage Rating
630 A
Application
Designed to provide Fully Shielded, Dead-Front Submersible Cable Connections to High-Voltage Apparatus
Color
Black
Conductor Range
400 kcmil , 450 kcmil
Connection
Compression
Connection Type
Compression Lug
Current Rating
630A
Current Rating
630 A
Environmental Conditions
All Weather Conditions
Insulation
True
Length
13 in
Length
330.2 mm
Material
Housing - EPDM-Rubber
Material
EPDM, Aluminum
Material
Aluminum
Material
Aluminum, Poly
Mounting Type
Deadbreak Elbow
Series
K465 Series
Series
K465LR
Size
0.850-1.050 inch (cable insulation diameter)
Size
Cable Insulation Diameter 0.850-1.050 inches (21.590-26.670mm)
Size
0.850-1.050 inches (21.590-26.670mm)
Special Features
Fully shielded, fully submersible molded rubber housing. 100 Percent peroxide-cured construction includes insulation and conductive EPDM materials. Can be easily connected or disconnected using standard hand tools and equipment in a de-energized state. Optional accessories allow visible external separation, by-pass, isolation, dead-ending, grounding, and testing as well as adding taps, surge arrestors, and fault current indicators
Standard
ANSI/IEEE Standard 386/ IEC
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Deadbreak Elbow Connector
Voltage Rating
15/25kV
Voltage Rating
15/25 kV
Voltage Rating
15 to 25 kV
Width
10.36 in
Width
263.144 mm
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
7.2500 L
Package Weight (Metric)
3.2890 kg
600 Amp, 35KV, Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter, Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 400 /Compacted Solid 450 /mmSquared Compact 240.

755LR-J0310

600 Amp, 35KV, Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter, Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 400 /Compacted Solid 450 /mmSquared Compact 240.
900 Amp, 35KV, DeadBreak, Direct Test Elbow with insulated Plug, Cap, Stud, Lug and Cable Adapter, Cable Insulation Diameter 0.980 inch to 1.180 inch. Copper Compression Lug. Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43.

775LR-J2250

900 Amp, 35KV, DeadBreak, Direct Test Elbow with insulated Plug, Cap, Stud, Lug and Cable Adapter, Cable Insulation Diameter 0.980 inch to 1.180 inch. Copper Compression Lug. Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43.
600 Amp, 35KV, DeadBreak, Elbow with Test Point, with Insulated Plug, Cap, Stud, Lug and Cable Adapter, Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 3/0 /Solid 4/0 /mmSquared 85.01.

756LR-L0260

600 Amp, 35KV, DeadBreak, Elbow with Test Point, with Insulated Plug, Cap, Stud, Lug and Cable Adapter, Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 3/0 /Solid 4/0 /mmSquared 85.01.
900 Amp, 35KV, DeadBreak, Elbow with Test Point, with insulated Plug, Cap, Stud, Lug and Cable Adapter, Cable Insulation Diameter 0.980 inch to 1.180 inch. Copper Compression Lug. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.

776LR-J2240

900 Amp, 35KV, DeadBreak, Elbow with Test Point, with insulated Plug, Cap, Stud, Lug and Cable Adapter, Cable Insulation Diameter 0.980 inch to 1.180 inch. Copper Compression Lug. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.
600 Amp, 35KV, DeadBreak, Elbow with Test Point, with Insulated Plug, Cap, Stud, Lug and Cable Adapter, Cable Insulation Diameter 1.725 inch to 1.935 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 900 /Compacted Solid 1000 /mmSquared Compact 500.

756LR-P0400

600 Amp, 35KV, DeadBreak, Elbow with Test Point, with Insulated Plug, Cap, Stud, Lug and Cable Adapter, Cable Insulation Diameter 1.725 inch to 1.935 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 900 /Compacted Solid 1000 /mmSquared Compact 500.
900 Amp, 35KV, DeadBreak, Elbow with Test Point, with insulated Plug, Cap, Stud, Lug and Cable Adapter, Cable Insulation Diameter 1.090 inch to 1.310 inch. Copper Compression Lug. Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43.

776LR-K2250

900 Amp, 35KV, DeadBreak, Elbow with Test Point, with insulated Plug, Cap, Stud, Lug and Cable Adapter, Cable Insulation Diameter 1.090 inch to 1.310 inch. Copper Compression Lug. Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43.
600 Amp, 35KV, DeadBreak, Elbow with Test Point, with Insulated Plug, Cap, Stud, Lug and Cable Adapter, Cable Insulation Diameter 1.900 inch to 2.120 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 1000. Cold-Shrinkable Jacket Seal Included.

756LR-Q0410-S

600 Amp, 35KV, DeadBreak, Elbow with Test Point, with Insulated Plug, Cap, Stud, Lug and Cable Adapter, Cable Insulation Diameter 1.900 inch to 2.120 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 1000. Cold-Shrinkable Jacket Seal Included.
600 Amp, 35KV, DeadBreak, Elbow with Test Point, with Insulated Plug, Cap, Stud, Lug and Cable Adapter, Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 500 /Compacted Solid 600 /mmSquared Compact 250/300. Cold-Shrinkable Jacket Seal Included.

756LR-N0330-S

600 Amp, 35KV, DeadBreak, Elbow with Test Point, with Insulated Plug, Cap, Stud, Lug and Cable Adapter, Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 500 /Compacted Solid 600 /mmSquared Compact 250/300. Cold-Shrinkable Jacket Seal Included.

Frequently Asked Questions

What is the continuous current rating of the K465LR?

The K465LR has a continuous current rating of 630 Amps. It can handle a maximum continuous current of 1250 Amps if the connected equipment is also rated for 1250A.

What is the maximum operating voltage for the K465LR?

The K465LR is rated for a maximum phase-to-ground operating voltage of 16.2kV and a maximum phase-to-phase voltage of 28kV for the 25kV voltage class.

What is the K465LR elbow connector used for?

The K465LR elbow connector provides fully shielded, dead-front submersible cable connections to high-voltage apparatus. It is designed for use through 28kV.

What conductor sizes and materials are compatible with K465LR?

The K465LR is compatible with aluminum and copper conductors ranging from 1/0 to 1250 kcmil.

What cable insulation diameters does the K465LR support?

The K465LR supports cable insulation diameters from .640 inches to 1.935 inches.

What bushing interfaces does the K465LR elbow connector have?

One end of the K465LR conforms to IEC-71 for standard 630 A European Switchgear, while the other end has a standard ANSI 386 Fig 11 bushing interface.

What are the short circuit ratings for the K465LR?

The K465LR has a short circuit rating of > 28 kA RMS symmetrical and > 70 kA peak asymmetrical.

What are the impulse and AC/DC withstand ratings?

The K465LR has a 140kV BIL impulse withstand, 55kV AC one-minute withstand, and 84kV DC 15-minute withstand.

What is the maximum operating voltage for the K465LR?

The K465LR is rated for a maximum phase-to-ground operating voltage of 16.2kV and a maximum phase-to-phase voltage of 28kV for the 25kV voltage class.

What are the short circuit ratings for the K465LR?

The K465LR has a short circuit rating of > 28 kA RMS symmetrical and > 70 kA peak asymmetrical.

How to Identify and Prepare the M16 to 5/8-11 Thread Conversion Stud

This guide details how to identify the M16 and 5/8-11 ends of the double-ended conversion stud for proper application in thread conversion.

Estimated time: 5m

Supplies needed:

M16 to 5/8-11 double-ended conversion stud

  1. Identify the M16 Threaded End

    Locate the M16 threaded end of the stud. This end is clearly marked with an 'M' for easy identification, indicating its metric thread.

  2. Identify the 5/8-11 Threaded End

    Locate the 5/8-11 English threaded end of the stud. This end is opposite the M16 marked end and is designed for 5/8-11 English threads.

  3. Prepare for Thread Conversion

    With both ends of the stud identified, align the appropriate threaded end with the corresponding component to begin the thread conversion process between M16 metric and 5/8-11 English threads.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.