ABB - Installation Products 274RLR-J-5240 - 200 Amp, 25kV, Loadbreak Replacement Elbow Connector with Test Point, Repair Elbow has extended length contact and elbow housing resulting in a net gain of 8-7/8 inches in length. Includes 00400X long Bi-Metal Contact. Cable Insulation Diameter 0.980 inch to 1.180 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.

ABB Installation Products 274RLR-J-5240 200 Amp, 25kV, Loadbreak Replacement Elbow Connector with Test Point, Repair Elbow has…

UPC: 783786455478


Documents & Media
BrochureInstallation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

ABB Installation Products 274RLR-J-5240 is a 200 Amp, 25kV loadbreak replacement elbow connector designed for medium-voltage cable systems requiring safe, reliable loadbreak operations. The extended contact and elbow housing provide an 8-7/8 inch net length gain, improving clearance in tight installations while maintaining full-rated performance. This repair elbow includes a 00400X long Bi-Metal Contact for enhanced conductivity and durability, ensuring consistent electrical performance under load. The integrated test point allows for safe voltage verification without service interruption, critical for maintenance and troubleshooting in utility and industrial substations. Designed for cable insulation diameters between 0.980 inch and 1.180 inch, this elbow connector is ideal for underground distribution systems, pad-mounted transformers, and switchgear applications where loadbreak functionality and extended reach are required. The replacement design simplifies repairs by eliminating the need for full cable replacement, reducing downtime and labor costs. Compliance with industry standards ensures reliable operation in 25kV class systems.
  • 200 Amp, 25kV rated loadbreak replacement elbow connector
  • Extended housing provides 8-7/8 inch net length gain for improved clearance
  • Integrated test point enables safe voltage verification without service interruption
  • Compatible with cable insulation diameters from 0.980 inch to 1.180 inch

Specifications

Amperage Rating
200 A
Application
25kV, 200 Amps
Color
Black
Conductor Range
1/0 STR/COMPR AWG , 2/0 SOL/COMPT AWG
Environmental Conditions
Fully Submersible
Insulation
True
Material
Housing - EPDM-Rubber
Size
Cable Insulation Diameter 0.980 inch to 1.180 inch
Special Features
Replacement Elbow has extended length contact and elbow housing resulting in a net gain of 8-7/8 inches in length. Includes 00400X long Bi-Metal Contact
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Loadbreak Replacement Elbow Connector with Test Point
Voltage Rating
25 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
2.4500 L
Package Weight (Metric)
1.1110 kg
600 Amp, 15/25kV, 600 Series Deadbreak, Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Aluminum Compression Lug. Cable Insulation Diameter 0.850 inch to 1.050 inch. Conductor Size AWG Compressed Stranded 1/0 or Compacted Solid 2/0.

K655LR-H0240

600 Amp, 15/25kV, 600 Series Deadbreak, Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Aluminum Compression Lug. Cable Insulation Diameter 0.850 inch to 1.050 inch. Conductor Size AWG Compressed Stranded 1/0 or Compacted Solid 2/0.
600 Amp, 35KV, Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter, Cable Insulation Diameter 1.090 inch to 1.310 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67. Cold-Shrinkable Jacket Seal Included.

755LR-K0270-S

600 Amp, 35KV, Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter, Cable Insulation Diameter 1.090 inch to 1.310 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67. Cold-Shrinkable Jacket Seal Included.
200 Amp, 15kV, Loadbreak Replacement Elbow Connector with Test Point, Cable Insulation Diameter 0.640 inch to 0.820 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded #3/Solid #2/mmSquared 26.67. 200ECS Jacket Seal Included. Repair Elbow has extended length contact and elbow housing resulting in a net gain of 8-7/8 inches in length. Includes 00400X long Bi-Metal Contact.

168RLR-F-5210-S

200 Amp, 15kV, Loadbreak Replacement Elbow Connector with Test Point, Cable Insulation Diameter 0.640 inch to 0.820 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded #3/Solid #2/mmSquared 26.67. 200ECS Jacket Seal Included. Repair Elbow has extended length contact and elbow housing resulting in a net gain of 8-7/8 inches in length. Includes 00400X long Bi-Metal Contact.
200 Amp, 15kV, Loadbreak Replacement Elbow Connector with Test Point, Cable Insulation Diameter 0.760 inch to 0.950 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded #1/Solid 1/0 /mmSquared 42.41. 200ECS Jacket Seal Included. Repair Elbow has extended length contact and elbow housing resulting in a net gain of 8-7/8 inches in length. Includes 00400X long Bi-Metal Contact.

168RLR-G-5230-S

200 Amp, 15kV, Loadbreak Replacement Elbow Connector with Test Point, Cable Insulation Diameter 0.760 inch to 0.950 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded #1/Solid 1/0 /mmSquared 42.41. 200ECS Jacket Seal Included. Repair Elbow has extended length contact and elbow housing resulting in a net gain of 8-7/8 inches in length. Includes 00400X long Bi-Metal Contact.
200 Amp, 15kV, Loadbreak Replacement Elbow Connector with Test Point, Cable Insulation Diameter 0.850 inch to 1.050 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67. 200ECS Jacket Seal Included. Repair Elbow has extended length contact and elbow housing resulting in a net gain of 8-7/8 inches in length. Includes 00400X long Bi-Metal Contact.

168RLR-H5270-S

200 Amp, 15kV, Loadbreak Replacement Elbow Connector with Test Point, Cable Insulation Diameter 0.850 inch to 1.050 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67. 200ECS Jacket Seal Included. Repair Elbow has extended length contact and elbow housing resulting in a net gain of 8-7/8 inches in length. Includes 00400X long Bi-Metal Contact.
200 Amp, 15kV, Loadbreak Repair Elbow Connector with Test Point, Cable Insulation Diameter 0.665 inch to 0.895 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded #4/Solid #3/mmSquared 21.14.

168ELR-6689-5200

200 Amp, 15kV, Loadbreak Repair Elbow Connector with Test Point, Cable Insulation Diameter 0.665 inch to 0.895 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded #4/Solid #3/mmSquared 21.14.
200 Amp, 15kV, Loadbreak Replacement Elbow Connector with Test Point, Cable Insulation Diameter 0.760 inch to 0.950 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded #4/Solid #3/mmSquared 21.14. Repair Elbow has extended length contact and elbow housing resulting in a net gain of 8-7/8 inches in length. Includes 00400X long Bi-Metal Contact.

168RLR-G5200

200 Amp, 15kV, Loadbreak Replacement Elbow Connector with Test Point, Cable Insulation Diameter 0.760 inch to 0.950 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded #4/Solid #3/mmSquared 21.14. Repair Elbow has extended length contact and elbow housing resulting in a net gain of 8-7/8 inches in length. Includes 00400X long Bi-Metal Contact.
15/25kV 200 Amp, Deadbreak Straight Receptacle, Bails are required, but not included, order separately. Cable Insulation Diameter 0.575 inch to 0.740 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded #2/Solid #1/mmSquared 33.62.

K151SR-A0220

15/25kV 200 Amp, Deadbreak Straight Receptacle, Bails are required, but not included, order separately. Cable Insulation Diameter 0.575 inch to 0.740 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded #2/Solid #1/mmSquared 33.62.

Frequently Asked Questions

How much length does the repair elbow add?

The repair elbow provides an extended length of 3 1/4 inches compared to a standard elbow.

What voltage classes do these elbows support?

The ABB Elastimold loadbreak repair and replacement elbows are designed for 15 kV and 25 kV applications.

How much length does the replacement elbow add?

The replacement elbow provides an extended length of 8 7/8 inches compared to a standard elbow.

What is the current rating of these elbow connectors?

The Elastimold repair and replacement elbow connectors are rated for 200 amps.

What cable insulation diameter does the 274RLR-J support?

The 274RLR-J replacement elbow supports a cable insulation diameter range of 0.980 inches minimum to 1.180 inches maximum.

What is the catalog number for the test point cap?

The catalog number for the test point cap used with these elbows is 156-7.

What industry standards do these elbows meet?

The Elastimold 200 A loadbreak elbows are IEEE 386 compliant, ANSI certified, and Rural Utilities Service (RUS) accepted.

What industry standards do these elbows meet?

The Elastimold 200 A loadbreak elbows are IEEE 386 compliant, ANSI certified, and Rural Utilities Service (RUS) accepted.

What cable insulation diameter does the 274RLR-J support?

The 274RLR-J replacement elbow supports a cable insulation diameter range of 0.980 inches minimum to 1.180 inches maximum.

What is the catalog number for the test point cap?

The catalog number for the test point cap used with these elbows is 156-7.

How to Install the 274RLR Loadbreak Replacement Elbow Connector

This guide details the installation of the 274RLR Loadbreak Replacement Elbow Connector, converting a livefront termination to deadfront for UD cable. It covers cable preparation, lug installation, elbow assembly, and neutral connection.

Estimated time: 1h

Tools needed:

Probe Wrench, Wire brush, Hotstick (live-line tool), Suitable capacitive voltage sensing device

Supplies needed:

274RLR Replacement Elbow Connector Housing, Compression Lug, Probe, Lubricant (supplied with kit), Hose Clamp, No. 14 AWG (2.5mm) copper wire, Grounding connector, Silicone grease

  1. De-energize apparatus and remove existing livefront termination

    DANGER: Ensure all apparatus is de-energized during installation or removal. Remove the rubber cap from the terminator, cut off the connector at the top, disconnect the ground lead from the base, and then remove the terminator housing from the cable.

  2. Prepare the cable for termination

    Train the cable to be straight and in-line with the bushing centerline. Cut the cable to measure 10-1/2 inches from the bushing centerline. Carefully remove 1-3/8 inches of cable insulation from the end, ensuring a square cut and avoiding nicks to the conductor. If the insulation shield is greater than 6-1/2 inches, consult an ELASTIMOLD representative.

  3. Install the compression lug

    Wire brush the bare aluminum conductor and immediately install the compression lug. Rotate the lug to spread the inhibitor. Position the compression lug so its contact threaded hole aligns with the bushing bore. Crimp the lug starting at the crimp line mark, rotating 180 degrees for each successive crimp. Carefully wipe off any excessive inhibitor from the lug and cable.

  4. Assemble the elbow connector

    Lubricate the cable insulation and the inside of the elbow housing with the supplied lubricant; do not substitute. Slide the elbow connector onto the cable using a back-and-forth twisting motion, then wipe off all excess grease. Align the elbow with the compression lug's threaded hole. Thread the probe into the lug by hand, ensuring it turns freely for approximately four turns before becoming snug. Tighten with the probe wrench until the wrench bends.

  5. Connect the concentric neutral

    Using a separate No. 14 AWG (2.5mm) copper wire or equivalent, insert one end through the grounding eye on the elbow and twist it tight, taking care not to damage the eye. Twist all neutral wires together and connect them to ground using an appropriate connector, ensuring adequate slack for elbow operation. Add the supplied hose clamp as shown and tighten snugly, but do not overtighten.

  6. Connect the elbow to the bushing plug

    If the transformer and elbow are known to be de-energized, lubricate the receptacle portion of the elbow connector and the mating bushing with the supplied lubricant. Use a full insulated hotstick type live-line tool to connect the elbow to the bushing plug, following loadmake operating instructions. Do not operate by hand.

  7. Perform voltage test (274RLR only)

    For the 274RLR model, remove the test point cap with a hotstick, peeling it off at an angle. WARNING: The voltage test point is a capacitance device; do not use conventional voltage measuring equipment. Use a suitable capacitive voltage sensing device, following its manufacturer's directions, to determine if the cable is energized. Treat the elbow as energized until the 'no voltage' indication is confirmed by other means. After testing, clean and lubricate the inside surface of the cap with silicone grease and replace it tightly on the test point.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.