ABB Installation Products 69TCT234142PABN 69kV, Transmission Cable Terminator, Base and Top Module, Housing Size 3, Connection…
UPC: 783786393909
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- Class 1 termination for 69kV solid dielectric cables per IEC-840 and IEEE-48
- Accommodates insulation diameters up to 86.4mm (3.400") and conductor sizes from 90mm² to 1700mm² (4/0 to 3500 kcmil)
- Molded EPDM elastomer housing eliminates glaze damage failures; no surface oil/grease required
- 4-hole NEMA connection type with Housing Size 3 configuration for secure bolted interfaces
- Lightweight at 14kg (30.1 lb.) with 45-minute installation time using Elastimold TCJ-ATK-U tool
- Flat braid metallic screen kit for grounding and EMI shielding
- Heat shrink armor kit for moisture ingress protection and strain relief
Specifications
Application | Cable Terminations, 69kV |
Cable Type | Copper Tape Shielded Wire |
Color | Gray |
Conductor Size | 1.153 to 1.220 in |
Connection Type | 4 Hole NEMA |
Earthing | Products Includes Their Own Grounding System |
Material | Aluminum |
Mounting | No Bracket Required |
Mounting Type | No Bracket Required |
Nema Rating | Type 4 |
Number Of Terminals | (1) Single Phase |
Series | 69TCT |
Size | Size 3 |
Special Features | Molded EPDM Elastomer Housing is Durable under Severe Envoronmental Conditions. Lightweight and easy to Handle |
Standard | IEEE 48 and IEC-840 |
Type | Cable Termination |
Voltage Rating | 69 kV |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 1.0000 L |
Package Weight (Metric) | 0.4540 kg |

69TCT23N242PABN
69kV, Transmission Cable Terminator, Base and Top Module, Housing Size 3, Connection Type - None, Connector Type - Copper, Conductor Size Code 42P, Metallic Screen Kit - Flat Braid, Armour Kit - Heat Shrink, No Bracket Required
R2T15M4-N2410
Outdoor, Ranger2 Termination, 15kV, Cable Type Tape Shield/Wire Shield/Unishield, Insulation Range 1.30 to 2.10 inch (33-53mm). Connector Type Copper 2-Hole Spade #2-1250 kcmil. Conductor Size 1000 Compressed/Stranded.
R2T28J4-N2330
Ranger2 Termination for 25/28KV outdoor application, cable insulation diameter 1.30 - 2.10 inches for Concentric Neutral/Jacketed Concentric Neutral Cable, Copper 2-Hole Spade #2-1250 kcmil, Stranded / Compressed 500 kcmil or Compact / Solid 600 kcmil. No Cable Mounting Bracket
R2T15J1-H0300
15 kv, Ranger2 Terminator, OutDoor, Concentric Neutral/Jacketed Concentric Neutral, .64 inch to 1.12 inch Insulation Range, Connector Type - Aluminum 1 hole Spade #2-500 kcmil, Conductor Code 300 - Standard or Compressed 350, Compact or Solid 400.
PCT1-3
15kV, Housing Only, Pre-Molded Cable Termination, 2-Hole Spade Lug, For use with Insulation Diameter Range from .830 inch to 1.180 inch.
PCT2-3
25kV, Housing Only, Pre-Molded Cable Termination, 2-Hole Spade Lug, For use with Insulation Diameter Range from .830 inch to 1.180 inch.
69TCT232231PNAN
69kV, Transmission Cable Termination (TCT). Base and Top Module, Housing Size 3, Connection Type 2 - 2 Hole NEMA, Connector Type - Copper, Conductor Size 31P, Metallic Screen Kit - Not Required, Armour Kit - Jacketing Tape and Mastic, No Bracket Required.
R2T15J1-N0380
Ranger2 Termination for 15KV outdoor application, cable insulation diameter .64 - 1.12 inches for Concentric Neural and Jacketed Concentric Neutral Cable, Aluminum 2 Hole Spade #2-1250 kcmil, Stranded or Compressed 700, Compact or Solid 900.Frequently Asked Questions
What is the nominal voltage of the 69TCT Terminator?
The nominal voltage (Uo/U) for the 69TCT Terminator is 40kV/59kV.
What cable insulation diameters does the 69TCT support?
It supports solid dielectric cables with insulation diameters up to 86.4mm (3.400 in).
What items are included in each 69TCT Terminator kit?
Each kit includes one TCT Terminator, one instruction sheet, one conductive paint package, and two mastic tapes.
What material is the 69TCT Terminator housing made of?
The housing is made of molded EPDM elastomer, which is durable under severe environmental conditions.
Does the 69TCT Terminator require surface oil or grease?
No, its non-tracking polymer and molded EPDM elastomer housing do not require surface oil or grease.
What is the weight of the 69TCT Terminator?
The 69TCT Terminator is lightweight, weighing 14kg (30.1 lb.).
What conductor sizes can the 69TCT Terminator accommodate?
The 69TCT Terminator accommodates conductor sizes from 90mm2 (4/0) to 1700mm2 (3500 kcmil).
What standards does the 69TCT Terminator conform to?
The 69TCT Terminator conforms to both IEC-840 and IEEE-48 standards.
What cable systems is the 69TCT Terminator compatible with?
The 69TCT Terminator provides Class 1 termination for cable systems rated through 69kV class.
What is the BIL rating of the 69TCT Terminator?
The BIL rating for the 69TCT Terminator is 350 kV (10 positive, 10 negative @ 1.2x50 microsecond wave).
How to Install the ELASTIMOLD TCT Outdoor Transmission Cable Termination
This guide provides step-by-step instructions for the safe and proper installation of the ELASTIMOLD TCT outdoor transmission cable termination, including cable preparation, component assembly, and final sealing.
Estimated time: 2h 30m
Tools needed:
Cable cutting tool, Measuring tape, Hose clamp, Sanding abrasive, Paint brush, Wrench set, Wire brush, Crimping tool, Soldering iron, Heat gun
Supplies needed:
Cable cleaner, Vinyl electrical tape, Semi-conductive paint (supplied), Lubricant (supplied), Mastic (supplied), Solder, Mastic tape, Silicone tape, Spade contact (supplied), Heat shrink sleeve (supplied), Cable Clamp (supplied), Winch Assembly (supplied), Adapter Plates (supplied), Housing Clamp (supplied), Bolts (supplied), Terminator Base Section (supplied), Terminator Module Section (supplied), Scintillation ring (supplied), #12 AWG copper drain wire (supplied), Flat braid (supplied)
- Safety and Initial Cable Preparation
DANGER: All apparatus must be de-energized during installation. Ensure installation is performed by competent personnel trained in high voltage safety. Straighten the cable and place it in its final position using the spade contact as a guide. Square cut the cable end and note the depth of the spade contact hole (X).
- Prepare Cable Jacket and Shield
Carefully remove the outer jacket material to a distance of 45.5 inches (111.6 cm) from the cable end to expose the cable shield. Slide the heat shrink sleeve onto the cable. Remove the cable shield to a distance of 43.5 inches (110.5 cm) from the cable end.
- Prepare Non-Metallic Screen and Insulation
Remove the non-metallic screen to a distance of 40 inches (101.5 cm) from the end of the conductor, being careful not to cut or nick the exposed insulation. Chamfer the non-metallic screen edge for a minimum of 1/2 inch (1.5 cm). Using a hose clamp as a guide, square cut the cable insulation at X+1 inch from the end of the conductor, then remove the hose clamp. Sand out all nicks and abrasions on the extruded non-metallic screen chamfer and cable insulation. Chamfer the edge of the cable insulation for approximately 3 inches (7.5 cm).
- Clean and Paint Cable Insulation
Using cable cleaner, clean the cable insulation and extruded non-metallic screen, cleaning towards the outer jacket to prevent contamination. Place a vinyl tape marker on the cable insulation surface at 39.5 inches (100.5 cm). Stir the supplied semi-conductive paint well and apply it to the exposed insulation and a minimum of 1 inch (2.5 cm) of the extruded non-metallic screen. Remove the vinyl tape within 5 to 15 minutes, ensuring the paint edge is smooth and square. Allow the paint 60 minutes to dry completely.
- Assemble Clamping and Winch Components
Place a vinyl tape marker onto the cable non-metallic shield 2 inches (5 cm) from the edge of the paint. Assemble the Cable Clamp at least 55 inches (140 cm) back from the conductor and tighten it securely. Place the Winch Assembly in front of the Cable Clamp and attach its stationary hooks to the Cable Clamp. Attach the Adapter Plates to the Housing Clamp with the supplied bolts, then assemble the Housing Clamp around the Terminator Base Section. Extend the steel cable(s) on the Winch Assembly until the hooks reach the Housing Clamp, then hook the cables to the Housing Clamp. Thoroughly lubricate the cable in the specified area and direction with the supplied lubricant.
- Install Terminator Sections
Assemble the Terminator Base Section onto the cable approximately 12 inches from the end. Release tension on each steel cable, then extend the steel cables and Housing Clamp. Position the Terminator Module Section in the Housing Clamp. Install the units until they overlap and continue assembling the mated units until the Terminator Base Section is flush with the tape marker. Remove the Winch Assembly, Housing Clamp, Adapter Plate, and Cable Clamp.
- Connect Conductor and Apply Initial Mastic
Remove the tape marker on the insulation shield. Remove the cut section of insulation on the cable to expose the conductor. Wirebrush the conductor thoroughly and immediately insert it into the spade contact. Crimp the connector according to the enclosed crimping instructions. Remove any excess inhibitor where applicable. Apply two layers of mastic: one at the end of the stress cone and one 2 inches (5 cm) back from the end of the cable jacket.
- Install Grounding Components and Final Sealing
Install the scintillation ring and the #12 AWG copper drain wire. Solder the flat braid and the #12 drain wire to the shield. Apply a second layer of mastic over the drain wire, on top of the previously applied mastic around the base of the stress cone. Apply a second layer of mastic over the flat braid, on top of the previously applied mastic on the cable jacket. Slide the heat shrink sleeve up to the grounding eye of the base of the terminator. Apply heat to the sleeve, starting in the middle and working towards each end, until mastic sealer squeezes from the ends. Connect the flat braid to the system ground. Seal the cable end with mastic tape between the contact and cable insulation. Apply two half-lapped layers of silicone tape, covering the crimp connector, mastic tape, and the upper portion of the terminator skirt.
- Mount Terminated Cables
Mount the terminated cables to the supporting structure. Ensure a minimum clearance of 4.0 inches (10 cm) is maintained between the terminator stress cone base and the supporting structure, in accordance with individual user, local, and national work rules.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.