ABB - Installation Products 69TCT23N242PABN - 69kV, Transmission Cable Terminator, Base and Top Module, Housing Size 3, Connection Type - None, Connector Type - Copper, Conductor Size Code 42P, Metallic Screen Kit - Flat Braid, Armour Kit - Heat Shrink, No Bracket Required

ABB Installation Products 69TCT23N242PABN 69kV, Transmission Cable Terminator, Base and Top Module, Housing Size 3, Connection…

UPC: 783786522323


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB 69TCT23N242PABN is a 69kV transmission cable terminator engineered for high-voltage cable termination in substations, switchgear, and transmission line applications. This terminator features a Size 3 housing optimized for conductor size code 42P, ensuring compatibility with standard 69kV systems. The copper connector provides low-resistance electrical continuity, critical for maintaining signal integrity and minimizing power loss in high-voltage circuits. The metallic screen kit includes a flat braid design, delivering effective shielding against electromagnetic interference (EMI) and radio frequency interference (RFI), which is essential for protecting sensitive equipment in industrial environments. The armour kit utilizes heat shrink technology to provide durable mechanical protection and environmental sealing, safeguarding the terminator against moisture, dust, and mechanical stress. No additional bracket is required for installation, simplifying deployment and reducing setup time. The terminator is designed for use with base and top modules, offering a modular approach to cable termination that enhances flexibility and scalability in electrical infrastructure projects. Compatible with standard 69kV systems, this terminator supports efficient and reliable cable termination without the need for specialized mounting hardware, making it a cost-effective solution for high-voltage applications.
  • 69kV rated transmission cable terminator for high-voltage applications
  • Size 3 housing optimized for conductor size code 42P
  • Copper connector ensures low-resistance electrical continuity
  • Flat braid metallic screen kit provides EMI/RFI shielding
  • Heat shrink armour kit offers durable mechanical protection and environmental sealing
  • No additional bracket required for simplified installation
  • Modular base and top module design for flexible deployment
  • Compatible with standard 69kV systems for broad industry application

Specifications

Application
Cable Terminations, 69kV
Cable Type
Copper Tape Shielded Wire
Color
Gray
Conductor Size
1.153 to 1.220 in
Earthing
Products Includes Their Own Grounding System
Material
Copper, Rubber, Heat Shrink
Material
Copper
Mounting
No Bracket Required
Mounting Type
Base and Top Module
Number Of Terminals
(1) Single Phase
Series
69TCT
Size
Size 3
Size
Housing Size 3
Special Features
Molded EPDM Elastomer Housing is Durable under Severe Envoronmental Conditions. Lightweight and easy to Handle
Standard
IEEE 48 and IEC-840
Type
Cable Termination
Voltage Rating
69 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
69kV, Transmission Cable Terminator, Base and Top Module, Housing Size 3, Connection Type 4 - 4 Hole NEMA, Connector Type - Aluminum, Conductor Size Code 42P, Metallic Screen Kit - Flat Braid, Armour Kit - Heat Shrink, No Bracket Required

69TCT234142PABN

69kV, Transmission Cable Terminator, Base and Top Module, Housing Size 3, Connection Type 4 - 4 Hole NEMA, Connector Type - Aluminum, Conductor Size Code 42P, Metallic Screen Kit - Flat Braid, Armour Kit - Heat Shrink, No Bracket Required
69kV, Transmission Cable Terminator, Base and Top Module, Housing Size 3, Connection Type 4 - 4 Hole NEMA, Connector Type - Aluminum, Conductor Size Code 43P, Metallic Screen Kit - 1/0 Bonding Cable 6 foot quantity 1 with split Bolts Quantity 2, Armour Kit - not required, No Bracket Required

69TCT234143PBNN

69kV, Transmission Cable Terminator, Base and Top Module, Housing Size 3, Connection Type 4 - 4 Hole NEMA, Connector Type - Aluminum, Conductor Size Code 43P, Metallic Screen Kit - 1/0 Bonding Cable 6 foot quantity 1 with split Bolts Quantity 2, Armour Kit - not required, No Bracket Required
69kV, Transmission Cable Terminator, Base and Two Top Module, Housing Size 1, Connection Type 2 - 2 Hole NEMA, Connector Type - Copper, Conductor Size Code 33P, Metallic Screen Kit - Flat Braid, Armour Kit - Jacketing Tape and Mastic, No Bracket Required

69TCT312233PAAN

69kV, Transmission Cable Terminator, Base and Two Top Module, Housing Size 1, Connection Type 2 - 2 Hole NEMA, Connector Type - Copper, Conductor Size Code 33P, Metallic Screen Kit - Flat Braid, Armour Kit - Jacketing Tape and Mastic, No Bracket Required
69kV, Transmission Cable Terminator, Base and Top Module, Housing Size 3, Connection Type - None, Connector Type - Copper, Conductor Size Code 46P, Metallic Screen Kit - Flat Braid, Armour Kit - Jacketing Tape and Mastic, No Bracket Required

69TCT23N246PAAN

69kV, Transmission Cable Terminator, Base and Top Module, Housing Size 3, Connection Type - None, Connector Type - Copper, Conductor Size Code 46P, Metallic Screen Kit - Flat Braid, Armour Kit - Jacketing Tape and Mastic, No Bracket Required
69kV, Transmission Cable Terminator, Base and Top Module, Housing Size 3, Connection Type 4 - 4 Hole NEMA, Connector Type - Aluminum, Conductor Size Code 40P, Metallic Screen Kit - Flat Braid, Armour Kit - Jacketing Tape and Mastic, No Bracket Required

69TCT234140PAAN

69kV, Transmission Cable Terminator, Base and Top Module, Housing Size 3, Connection Type 4 - 4 Hole NEMA, Connector Type - Aluminum, Conductor Size Code 40P, Metallic Screen Kit - Flat Braid, Armour Kit - Jacketing Tape and Mastic, No Bracket Required
Ranger2 Termination. Type - Outdoor, 28kV, Cable Type - Tape Shield/Wire Shield/ Unshield, Insulation Range - .84 inch - 1.38 inch, Connector Type - Tinned Aluminum 1-Hole Spade #2-500 kcmil, Conductor Code - 240 -Stranded or Compressed 1/0 Compact or Solid 2/0.

R2T28M2-H0240

Ranger2 Termination. Type - Outdoor, 28kV, Cable Type - Tape Shield/Wire Shield/ Unshield, Insulation Range - .84 inch - 1.38 inch, Connector Type - Tinned Aluminum 1-Hole Spade #2-500 kcmil, Conductor Code - 240 -Stranded or Compressed 1/0 Compact or Solid 2/0.
Indoor Ranger2 Cable Termination. 15kV, Cable Type - Tape Shield/Wire Shield/UniShield. Insulation Range - 1.30 inch - 2.10 inch. Copper 2-Hole Spade #2-1250 kcmil, Conductor 1000 Stranded/Compressed

R2IT15M4-N2410

Indoor Ranger2 Cable Termination. 15kV, Cable Type - Tape Shield/Wire Shield/UniShield. Insulation Range - 1.30 inch - 2.10 inch. Copper 2-Hole Spade #2-1250 kcmil, Conductor 1000 Stranded/Compressed
Ranger2 Termination, Indoor, 15kv, Cable Type - Tape Shield/WireShield/UniShield, Insulation Range - .64 ich - 1.12 inch (16mm-28mm), Connector Type - N2 - Copper 2-Hole Spade #2-1250kcmil, Conductor Sizes 2/0 Stranded/Compressed or 3/0 Compact/Solid, No Cable Mounting Bracket

R2IT15M1N2250

Ranger2 Termination, Indoor, 15kv, Cable Type - Tape Shield/WireShield/UniShield, Insulation Range - .64 ich - 1.12 inch (16mm-28mm), Connector Type - N2 - Copper 2-Hole Spade #2-1250kcmil, Conductor Sizes 2/0 Stranded/Compressed or 3/0 Compact/Solid, No Cable Mounting Bracket

Frequently Asked Questions

What voltage rating does this terminator support?

This terminator is rated for 69kV transmission applications.

What housing size is included with this terminator?

The terminator uses a Size 3 housing as specified in the catalog.

What type of connector does this terminator use?

The terminator includes a copper connector for electrical continuity.

Is a bracket required for installation?

No bracket is required for installation of this terminator.

What conductor size code is compatible with this terminator?

The terminator supports conductor size code 42P.

What type of metallic screen kit is included?

The metallic screen kit uses a flat braid design for shielding.

What type of armour kit is provided?

The armour kit uses heat shrink technology for protection.

How to Install the ELASTIMOLD TCT Outdoor Transmission Cable Termination

This guide provides step-by-step instructions for the safe and proper installation of the ELASTIMOLD TCT outdoor transmission cable termination. It covers cable preparation, component assembly, wiring, and final mounting.

Estimated time: 2h

Tools needed:

Cable stripping tools, Measuring tape, Hose clamp, Cable cleaner, Wirebrush, Crimping tool, Soldering iron, Heat gun, Sandpaper

Supplies needed:

Heat shrink sleeve, Semi-conductive paint, Vinyl tape marker, Lubricant, Cable clamp, Winch assembly, Adapter plates, Housing clamp, Terminator Base Section, Terminator Module Section, Mastic, Scintillation ring, #12 AWG copper drain wire, Flat braid, Silicone tape, Spade contact, Mounting hardware (customer supplied)

  1. Ensure Safety and Inspect Components

    Before beginning, ensure all apparatus is de-energized. This product must be installed only by competent personnel trained in high voltage safety practices. Inspect all package contents and components for completeness, damage, and proper fit with the cable and mating products. Have all required tools ready and maintain cleanliness.

  2. Prepare the Cable End

    Straighten the cable and position it in its final location, using the spade contact as a guide. Square cut the cable end. Carefully remove the outer jacket material to a distance of 45.5 inches (111.6 cm) to expose the cable shield. Slide the heat shrink sleeve onto the cable.

  3. Remove Shield and Non-Metallic Screen

    Remove the cable shield to a distance of 43.5 inches (110.5 cm) from the cable end. Next, remove the non-metallic screen to a distance of 40 inches (101.5 cm) from the end of the conductor, being careful not to cut or nick the exposed insulation. Chamfer the non-metallic screen edge for a minimum of 1/2 inch (1.5 cm).

  4. Cut and Chamfer Cable Insulation

    Using a hose clamp as a guide, square cut the cable insulation, ensuring not to nick the conductor. Measure from the end of the conductor. Remove the hose clamp. Sand out any nicks or abrasions on the extruded non-metallic screen chamfer and cable insulation. Chamfer the edge of the cable insulation for approximately 3 inches (7.5 cm).

  5. Clean Cable and Apply Semi-Conductive Paint

    Using a cable cleaner, thoroughly clean the cable insulation and extruded non-metallic screen, cleaning towards the outer jacket to prevent contamination. Place a vinyl tape marker on the cable insulation surface. Stir the supplied semi-conductive paint well and apply it to the exposed insulation and a minimum of 1 inch (2.5 cm) of the extruded non-metallic screen. Remove the vinyl tape within 5 to 15 minutes, ensuring a smooth, square paint edge. Allow the paint 60 minutes to dry.

  6. Place Vinyl Tape Marker on Shield

    Place a vinyl tape marker onto the cable's non-metallic shield, 2 inches (5 cm) from the edge of the applied semi-conductive paint.

  7. Assemble Cable Clamp and Winch Assembly

    Assemble the Cable Clamp at least 55 inches (140 cm) back from the conductor and tighten it securely. Place the Winch Assembly in front of the Cable Clamp and attach its stationary hooks. Attach the Adapter Plates to the Housing Clamp using the supplied bolts, then assemble the Housing Clamp around the Terminator Base Section. Extend the steel cables on the Winch Assembly and hook them to the Housing Clamp. Thoroughly lubricate the cable in the specified area with the supplied lubricant.

  8. Install Terminator Sections

    Assemble the Terminator Base Section onto the cable approximately 12 inches from the end. Release tension on the steel cables, then extend them and the Housing Clamp. Position the Terminator Module Section within the Housing Clamp. Continue assembling the mated units until the Terminator Base Section is flush with the tape marker. Remove the Winch Assembly, Housing Clamp, Adapter Plate, and Cable Clamp.

  9. Connect Conductor and Apply Mastic

    Remove the tape marker from the insulation shield. Remove the cut section of insulation to expose the conductor. Wirebrush the conductor and immediately insert it into the spade contact. Crimp the connector according to the enclosed crimping instructions. Remove any excess inhibitor. Apply two layers of mastic: one at the end of the stress cone and one 2 inches (5 cm) back from the end of the cable jacket.

  10. Install Grounding and Complete Sealing

    Install the scintillation ring and the #12 AWG copper drain wire. Solder the flat braid and the #12 drain wire to the shield. Apply a second layer of mastic over the drain wire and another over the flat braid. Slide the heat shrink sleeve up to the grounding eye of the terminator base. Apply heat to the sleeve, starting from the middle and working towards each end, until mastic sealer squeezes out. Connect the flat braid to the system ground. Seal the cable end with mastic tape between the contact and cable insulation. Apply two half-lapped layers of silicone tape covering the crimp connector, mastic tape, and the upper portion of the terminator skirt.

  11. Mount Terminated Cables

    Mount the terminated cables to a supporting structure. Ensure that a sufficient clearance (minimum 4.0 inches / 10 cm) is maintained between the terminator stress cone base and the supporting structure. Adhere to all individual user, local, and national work rules.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.